Professional Documents
Culture Documents
Lycoming SL L171 - General Aspects Fo Spectometric Oil Analysis
Lycoming SL L171 - General Aspects Fo Spectometric Oil Analysis
As the use of
spectrometric lubricating oil analysis cessively high´•concentrations of the metal of which it
has become morewidespread in the field of general is made willbe deposited in the oil and this wear can
aviation, the problems of methods, procedures, ~sched- increase over a periodof time untilpremature failure
ules and interpretation of data have become prevalent. results. By analyzing the oil spectrochemtcally for
This service letter is an attempt´•to clarify the subject this metalcontent, the increasing concentrations can
and to define how lubricating oil analysis can be used be detected and corrective action taken.
as another tool in the maintenance sf modern recipro-
ORIGINAL
Page i of 3
Manufactve~s Association
As Received By
ATP
Service Letter No. L171
cause of new parts mating together. After about 25 2. Figure 3 illustrates how spectrometric oil analy-
hours of operating time the metal content decreases sis can aidin the prevention of a major failure. At
rapidly to a level that essentially remains constant 900 hours, the wear rate for copper content in this
unless abnormalwear occurs due to dirt in the induc- engine increased from 10 PPM to 50 PPM, indica-
tion system or for other causes. Abnormal wear will ting serious bearing wear. Subsequent inspection
be quickly ’indicated by a "break" in the curve also proved this to be the case and a major failure was
shown in Figure 1. It should be emphasized that this prevented.
"break" in the normal wear rate does notnecessarily
mean that failure is imminent; but it does mean that It should be noted in Figure 3 that the metallic con-
an investigation (filters checked, bore-scope examin- tent of the various elements in the lube oil sampled at
ation, compression pressure check, etc. should be each check point are plotted against a "normal-wear-
undertaken to determine the cause for abnormal wear rate" expected for these elements.
as illustrated by the following examples:
NOTE CAUTION
Avco Lycoming claims no responsibility These values are published as a guide and
for engines remaining in service or re- liiay may not be directly applicable to
or
moved from service solely on the basis of all engines or laboratories providing this
a spectrometric oil analysis report, service.
Figure 3. Typical Spectrometric Oil Analysis d. If the sample is taken when the oil is drained,
let half the oil run out, then take the sample by
Showing Serious Bearing Wear (Cu)
holding the sample bottle in the oil stream.
at 900 Hours ORIGINAL
Page 2 of 3 As Received By
ATP
Service Letter No. L171
e. If desired, the sample maybe taken from the last oilchange, date sampled, and oil levelat sam-
oil filler tubeby means a rubber’ bulb and- a
of pling time. Also, indicate if cylinders are chrome
suction hose. If this method is used be sure the plated at overhaul; describe any major repair or
hose and bulb are cleaned with petroleum sol- top overhaul.
vent before and after the sample is taken and
that the solvent has evaporated. NOTE
3. There are certain items of information that must Avco Lycoming does not recommend any
accompany the oil sample which are as follows: particular company to provide spectrome-
Engine model number, engine serial number, air- tric oilanalysis service for aircraft main-
craft manufacturer, aircraft model, aircraft regis- tenance. However, at the present time
tration number, total hours on engine, hours since only those companies affiliated with the
overhaul, brand of fuel, octane rating of fuel, brand Spectrometric Oil Analysis Laboratory
of oil, viscosity of oil; type of oil- straight mineral, Association (SOALA) are conSidered to be
or ashless dispersant; oilconsumption, hours since adequately qualified.
Page 3 of 3