ELECTRICAL NOTES

1. ALL ELECTRICAL WORKS HEREIN SHALL BE EXECUTED IN


ACCORDANCE WITH THE PROVISION OF THE LATEST EDITION
OF PHILIPPINE ELECTRICAL CODE (PEC).

2. ALL ELECTRICAL WORKS HEREIN INCLUDED SHALL BE


1 2 3 4 5 EXECUTED BY EXPERIENCED MEN UNDER SUPERVISION OF
FULL TIME LICENSED ELECTRICAL ENGINEER. WORKS SHALL
BE NEATLY PLACED, SECURELY AND PROPERLY FINISHED.
3. ALL CONDUIT SHALL BE PROTECTED AGAINST DAMAGES BY
THE ENTRANCE OF WATER AND FOREIGN MATTER DURING
CONSTRUCTION. ALL ENDS ON CONDUITS SHALL BE PLUGGED
TO EXCLUDE MOISTURE AND DUST IMMEDIATELY AFTER
CONDUIT ARE PLACED. ALL CONDUIT END SHALL HAVE END
BUSHING FOR PROTECTION.
PROPERTY LINE/ PERIMETER FENCE
4. MOUNTING HEIGHT OF DEVICES SHALL BE AS APPROVED BY
PROJECT MANAGEMENT REPRESENTATIVE AND/OR AS
FOLLOWS: .
2 . 0 0 M R E A R S E T B A C K PANEL BOARD - 1800MM ABOVE FINISHED FLOOR LEVEL OF
PANEL (ACTUAL SITE CONDITION MUST PREVAIL)
WALL SWITCHES - 1370mm ABOVE FINISHED FLOOR
A 1 FS
1 A LEVEL TO CENTER OF DEVICES
FS FS POWER OUTLET - 300MM ABOVE FINISHED FLOOR LEVEL

1
TP FS TO CENTER OF BOX

1
TP TP FS TP
5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED
OTHERWISE.
FS
LEGEND OF SYMBOLS

2
FS FILE SERVER
FS
FS FS

2
FS TP TP TELECOM PANEL

1
2
2 2
2 - GANG LAN OUTLET
B 1
B 1
1 - GANG LAN OUTLET

TELEPHONE OUTLET
1

FUTURE EXTENSION OF THE WALKWAY


ACCESS TO THE RENTABLE BUILDING
XXX
2 2 CIRCUIT HOMERUN

FS TP FS
08 07 06 05 04 03 02 01
TP
UP FS
FS FS

1
TP TP

1
1
09 10 11 12 13 14 15 16 17 18

C C
P W D
RAMP
CANOPY LINE
3

UP

1 2 3 4 5

TWO-STOREY OFFICE BUILDING


EL-01 GROUND FLOOR AUXILIARY LAYOUT
028 01 SCALE 1:125MTS

PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE OWNER REV. DESCRIPTION DATE DESIGNED BY : JVDZ SHEET CONTENTS
IMPORTANT:

HOOD- EPC THIS DRAWING AND ITS CONTENT ARE THE


INTELLECTUAL PROPERTY OF HOOD-EPC
HOOD PARK DEVELOPMENT PROJECT
00 ISSUED FOR BIDDING 05-04-2024 DRAWN BY : JVDZ
AU ILIARY LAYOUT PLAN
CORPORATION CORPORATION. ALL RIGHTS RESERVED.
UNAUTHORIZED USE, REPRODUCTION, OR A PROPOSED 2-STOREY
HOOD CENTRAL PARK CHECKED BY : DCT/RJE
GROUND FLOOR
DELIVERING PROJECTS WITH CERTAINTY DISTRIBUTION IS STRICTLY PROHIBITED PROPERTY CORPORATION APPROVED BY : DCT
WITHOUT PRIOR CONSENT FROM ELECTRICAL ENGINEER OFFICE BUILDING
2/F Wanda Place, Diversion Road, Balagtas, Batangas City, 4200, Philippines HOOD-EPC CORPORATION AND MAY DATE ISSUED : 05-04-2024
PRC Reg. : : BRGY. PALSAHINGIN, SAN PASCUAL BATANGAS
☎ : (043) 727-5568 • ✉ : info@hood-epc.com • : https://hood-epc.com RESULT IN LEGAL ACTION. IAPOA No.:
PTR
DATE :
SIZE COST CODE NO. DOCUMENT TYPE DISCIPLINE CODE DRAWING NO. SHEET NO. REVISION NO.

TIN : PLACE :
CLIENT REPRESENTATIVE DATE REVISED : A3 9004 07 EL 165 01 OF 02 00