Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles

for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Designation: D1016 − 05 (Reapproved 2015)

Standard Test Method for


Purity of Hydrocarbons from Freezing Points1
This standard is issued under the fixed designation D1016; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.

1. Scope 2. Referenced Documents


1.1 This test method covers the sampling and determination 2.1 ASTM Standards:3
of purity of essentially pure compounds for which the freezing D1015 Test Method for Freezing Points of High-Purity
points for zero impurity and cryoscopic constants are given.2 Hydrocarbons
The compounds to which the test method is applicable are: 3. Summary of Test Method
(Warning—Extremely flammable liquids and liquefied gases.)
3.1 After measurement of the freezing point of the actual
n-butane 1,3-butadiene
isobutane isoprene(2-methyl-1,3-butadiene)
sample, purity can be calculated from the value of the
n-pentane benzene determined freezing point and the values given for the freezing
isopentane toluene (methylbenzene) point for zero impurity and for the applicable cryoscopic
n-hexane ethylbenzene
n-heptane o-xylene (1,2-dimethylbenzene)
constant or constants.4
n-octane m-xylene (1,3-dimethylbenzene) 3.2 For the equilibrium between an infinitesimal amount of
2,2,4-trimethylpentane p-xylene (1,4-dimethylbenzene)
methylcyclohexane styrene (ethenylbenzene) the crystalline phase of the major component and a liquid phase
isobutene of the major component and one or more other components, the
thermodynamic relation between the temperature of equilib-
1.2 The values stated in SI units are to be regarded as the
rium and the composition of the liquid phase is expressed by
standard. The values in parentheses are for information only.
the equation:5
1.3 This standard does not purport to address all of the 21n N 1 5 21n ~ 1 2 N 2 ! 5 A ~ t 2 t f ! @ 11B ~ t 2 t f ! 1… # (1)
f0 f0
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- where:
priate safety and health practices and determine the applica- N1 = mole fraction of the major component,
bility of regulatory limitations prior to use. For specific hazard N2 = (1 − N1) = sum of the mole fractions of all the other
statements, see Sections 1, 6, 8, and 10 – 26. components,
tf = freezing point, in degrees Celsius, of the given sub-
NOTE 1—This test method covers systems in which the impurities form stance (in which the mole fraction of the major
with the major component a substantially ideal or sufficiently dilute component is N1), defined as the temperature at which
solution, and also systems which deviate from the ideal laws, provided
an infinitesimal amount of crystals of the major
that, in the latter case, the lowering of the freezing point as a function of
the concentration is known for each most probable impurity in the given component is in thermodynamic equilibrium with the
substance. liquid phase (see Note 3 of Test Method D1015),
tf0 = freezing point for zero impurity, in degrees Celsius, for
the major component when pure, that is, when N1 = 1
or N2 = 0,

3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
This test method is under the jurisdiction of ASTM Committee D02 on Standards volume information, refer to the standard’s Document Summary page on
Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of the ASTM website.
4
Subcommittee D02.04.0D on Physical and Chemical Methods. For a more complete discussion of this test method, see Glasgow, A. R., Jr.,
Current edition approved April 1, 2015. Published May 2015. Originally Streiff, A. J., and Rossini, F. D., “Determination of the Purity of Hydrocarbons by
approved in 1949. Last previous edition approved in 2010 as D1016 – 05 (2010). Measurement of Freezing Points,” Journal of Research , JRNBA, National Institute
DOI: 10.1520/D1016-05R15. of Standards and Technology, Vol 35, No. 6, 1945, p. 355.
2 5
Numerical constants in this test method were taken from the most recently For details, see Taylor, W. J., and Rossini, F. D., “Theoretical Analysis of
published data appearing in “Tables of Physical and Thermodynamic Properties of Time-Temperature Freezing and Melting Curves as Applied to Hydrocarbons,”
Hydrocarbons and Related Compounds,” or ASTM DS 4A, Physical Constants of Journal of Research, JRNBA, Nat. Bureau Standards, Vol 32, No. 5, 1944, p. 197;
Hydrocarbons C1 to C10, or both, prepared by the American Petroleum Institute, also Lewis, G. N., and Randall, M., “Thermodynamics and the Free Energy of
Research Project 44. Chemical Substances,” 1923, pp. 237, 238, McGraw-Hill Book Co., New York, NY.

Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
1
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)

A = first or main cryoscopic constant, in mole fraction per 6.2.1 Use liquid nitrogen refrigerant only with adequate
degree, and ventilation. If liquid air is used as a refrigerant, it is imperative
B = secondary cryoscopic constant, in mole fraction per that any glass vessel containing hydrocarbon or other combus-
degree. tible compound and immersed in liquid air be protected with a
Neglecting the higher terms not written in the brackets, Eq 1 suitable metal shield. The mixing of a hydrocarbon or other
can be transformed to the equation: combustible compound with liquid air due to the breaking of a
glass container would almost certainly result in a violent
log10 P 5 2.00000 2 ~ A/2.3026! ~ t f 0 2 t f ! @ 11B ~ t f0 2 t f! # (2) explosion. If liquid nitrogen is used as a refrigerant, no
where: hydrocarbon sample should ever be permitted to cool below the
condensation temperature of oxygen (−183 °C at atm). This
P = purity of the given substance in terms of mole percent of
would not be likely to occur in normal operation, but might
the major component.
occur if the apparatus were left unattended for some time.
4. Significance and Use
7. Procedure
4.1 The experimental procedures and physical constants
provided by this test method, when used in conjunction with 7.1 Measure the freezing point as described in Test Method
Test Method D1015, allow the determination of the purity of D1015, using the modifications and constants given in Sections
the material under test. A knowledge of the purity of these 8 – 26 of this test method for the specific compounds being
hydrocarbons is often needed to help control their manufacture examined.
and to determine their suitability for use as reagent chemicals NOTE 2—The estimated uncertainty in the calculated value of the purity
or for conversion to other chemical intermediates or finished as referred to in Sections 8 – 26 is not equivalent to the precision defined
products. in RR:D02-1007.

5. Apparatus 8. n-Butane6 (Warning—Extremely flammable liquefied


gas under pressure. Vapor reduces oxygen available for
5.1 Sampling Apparatus, as shown in Fig. 1, for withdraw-
breathing.)
ing liquefied gases (for example, 1,3-butadiene) from pressure
storage cylinders. 8.1 Determine the freezing point from freezing curves, with
the cage stirrer, with a cooling bath of liquid nitrogen (or liquid
5.2 Distilling Apparatus, as shown in Fig. 2, for removing
air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the
small amounts of polymer from low-boiling compounds (for
liquid near the freezing point, and with crystallization induced
example, 1,3-butadiene) by simple distillation at atmospheric
immediately below the freezing point by means of a cold rod.
pressure.
8.2 The method of obtaining the samples shall be as
5.3 Distilling Apparatus, as shown in Fig. 3, for removing
follows: Assemble the apparatus for obtaining the sample as
small amounts of polymer from compounds with boiling points
shown in Fig. 1, but with no lubricant on the ground-glass
near room temperature (for example, isoprene) by distillation
joints and with the valve at the bottom of the cylinder, so that
at atmospheric pressure.
sampling is from the liquid phase. Attach to C an absorption
5.4 Vacuum Distilling Apparatus and Transfer Trap, as tube containing anhydrous calcium sulfate or other suitable
shown in Fig. 4, for removing dissolved air and large amounts desiccant (except magnesium perchlorate) so that water is not
of polymer from a compound (for example, 1,3-butadiene or introduced into the system (Note 3). Fill the flask F with the
styrene), by repeated freezing and evacuation, followed by carbon dioxide refrigerant to within about 51 mm (2 in.) of the
distillation of the compound in vacuum in a closed system. top. After about 20 min or 30 min, when the system will have
6. Materials cooled sufficiently, remove the absorption tube and begin the
collection of liquid n-butane by opening the valve K and
6.1 Carbon Dioxide Refrigerant—Solid carbon dioxide in a adjusting the needle valve J so that the sample is collected at
suitable liquid. (Warning—Extremely cold (−78.5 °C). Liber- a rate of 1 mL to 2 mL (liquid)/min in the condensing tube E.
ates heavy gas which can cause suffocation. Contact with skin
causes burns or freezing, or both. Vapors can react violently NOTE 3—However, if some water does condense with the hydrocarbon,
the freezing point will not be affected significantly because of the
with hot magnesium or aluminum alloys.) Acetone is recom- extremely low solubility of water in the hydrocarbon at the freezing point
mended. (Warning—Extremely flammable. Harmful if in- of the latter.
haled. High concentrations can cause unconsciousness or 8.3 Assemble the freezing point apparatus. Place the cool-
death. Contact can cause skin irritation and dermatitis. Use ing bath in position around the freezing tube (O in Fig. 1 of
refrigerant bath only with adequate ventilation!) Test Method D1015), letting the temperature as read on the
6.2 Liquid Nitrogen or Liquid Air—(Warning—Extremely platinum thermometer reach about −80 °C when all the sample
cold. Liberates gas which can cause suffocation. Contact with has been collected.
skin causes burns or freezing, or both. Vapors can react
violently with hot magnesium or aluminum alloys.) For use as 6
For further details, see Glasgow , A. R., Jr., et al. “Determination of Purity by
a refrigerant. If obtainable, liquid nitrogen is preferable be- Measurement of Freezing Points of Compounds Involved in the Production of
cause of its safety. Synthetic Rubber,” Analytical Chemistry, ANCHA, Vol 20, 1948, p. 410.

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
2
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)

A—Three-way T stopcock, borosilicate glass (similar to Corning Pyrex No. 7420).


B—Connection to vacuum for purging and for evacuating system CDEGHI.
C—Capillary tube for venting, to which drying tube is also connected.
D—Joint, standard taper, 12/30, borosilicate glass.
E—Condensing tube, borosilicate glass.
F—Dewar flask, 1 qt size, borosilicate glass (similar to American Thermos Bottle Co. No. 8645).
G—Tubing, borosilicate glass, 10 mm in outside diameter, with spherical ground-glass joints, 18/7.
H—Tubing, silicate glass, 10 mm in outside diameter, with spherical ground-glass joints, 18/7.
I—Metal connection, brass spherical male joint at one end fitting to connection to needle valve at other end.
J—Needle valve, brass.
K—Valve on cylinder containing hydrocarbon material.
L—Standard cylinder containing hydrocarbon material.
M—Fitting to connect needle valve J to valve K on cylinder.

FIG. 1 Apparatus for Obtaining Sample

8.4 When 50 mL of liquid (temperature about −80 °C) has 8.5 When the temperature of the platinum thermometer is
been collected in the condensing tube, close the valve K (Fig. near −80 °C, remove the condensing tube (E in Fig. 1) from the
1) and allow the liquid which has collected at I to warm and Dewar flask. Wrap a cloth around the upper portion of the
transfer to the condensing tube (Note 4). Replace the attaching condensing tube (for ease of handling and for preventing the
tubes G and D on the condensing tube by caps. The liquid refrigerating liquid from contaminating the sample on
sample is now ready for introduction into the freezing tube (O pouring), and after removing the caps on the condensing tube,
in Fig. 1 of Test Method D1015). raise the stopper holding the platinum thermometer, and pour
NOTE 4—In case the original sample contained water, there will remain the sample through the tapered male outlet of the condensing
at I some water that may be discarded after the hydrocarbon portion has tube into the freezing tube (O in Fig. 1 of Test Method D1015).
been collected as outlined above. Quickly replace the stopper holding the platinum thermometer,

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
3
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)

C—Dewar vessel, 1 qt capacity, borosilicate glass.


D—Clamp.
E—Distilling tube, borosilicate glass, 25 mm in outside diameter.
F—Standard-taper ground-glass joint, 24/40 borosilicate glass. A—Standard-taper, ground-glass joint, 24/40, borosilicate glass
G—Tubing, 10 mm in outside diameter, borosilicate glass. B—Distilling flask, round bottom, 200-mL capacity, borosilicate glass.
H, H'—Spherical ground-glass joints, 18/7, borosilicate glass. C—Tubing, 10 mm in outside diameter, borosilicate glass.
I—Tubing, 6 mm in outside diameter, borosilicate glass. D, D'—Spherical ground-glass joints, 18/7, borosilicate glass.
J—Receiver, 35 mm in outside diameter, 150 mm in length, borosilicate glass. E—Dewar flask, 1 qt capacity, borosilicate glass.
F—Receiver, same as J in Fig. 2.
FIG. 2 Simple Distilling Apparatus for Normally Gaseous Sub-
FIG. 3 Simple Distilling Apparatus for Normally Liquid Sub-
stances
stances
and start the stirrer, with dry air flowing into the upper portion
of the freezing tube through M (Fig. 1 of Test Method D1015).
8.6 Because the material is normally gaseous at room 9. Isobutane6 (Warning—Extremely flammable gas under
temperature, care should be taken in disposing of the sample pressure. Vapor reduces oxygen available for breathing.)
safely. 9.1 Determine the freezing point from freezing curves with
8.7 For n-butane, the freezing point for zero impurity, in air the cage stirrer, with a cooling bath of liquid nitrogen (or liquid
at 1 atm, is as follows: air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the
t f 0 5 2138.362 °C60.025 °C (3)
liquid near the freezing point, and with crystallization induced
immediately below the freezing point by means of a cold rod.
and the cryoscopic constants are:
9.2 Obtain the samples as follows: Assemble the apparatus
A 5 0.03085 mole fraction/°C and (4) for obtaining the sample as shown in Fig. 1, but with no
B 5 0.0048 mole fraction/°C. (5) lubricant on the ground-glass joints and with the valve at the
8.8 The cryoscopic constants given in 8.7 are applicable to bottom of the cylinder, so that sampling is from the liquid
samples of n-butane having a purity of about 95 mole % or phase. Attach to C an absorption tube containing anhydrous
better, with no one impurity present in an amount that exceeds calcium sulfate or other suitable desiccant (except magnesium
its eutectic composition with the major component. perchlorate) so that water is not introduced into the system
(Note 3). Fill the flask F with the carbon dioxide refrigerant to
8.9 The estimated uncertainty in the calculated value of the within about 51 mm (2 in.) of the top. After about 20 min or
purity is as follows, in mole %: 30 min, when the system will have cooled sufficiently, remove
Calculated Purity, Uncertainty, plus or the absorption tube and begin the collection of liquid isobutane
mole % minus, mole %
Over 99.5 0.08
by opening the valve K and adjusting the needle valve J so that
99.0 to 99.5 0.09 the sample is collected at a rate of 1 mL to 2 mL (liquid)/min
98 to 99 0.10 in the condensing tube E.
97 to 98 0.12
96 to 97 0.15 9.3 Assemble the freezing point apparatus. Place the cool-
95 to 96 0.20 ing bath in position around the freezing tube (O in Fig. 1 of

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
4
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)

A, A'—Standard-taper ground-glass joints, 14/35 borosilicate glass. G and G'—Ceramic (or glass) fiber pad.
B—Tubing, 27 mm in outside diameter, borosilicate glass. H, H', H9—Stopcock, ground for high vacuum, borosilicate glass.
C, C'—Clamp. I—Spherical ground-glass joint, 18/7, borosilicate glass.
D— Brass cylinder, 273 mm (103⁄4 in.) in length, 28.6 mm (11⁄8 in.) in inside J—Condensing tube, used as trap (see E in Fig. 1).
diameter; for precautions in use of liquid nitrogen and liquid air, see R in K—Connection to vacuum system.
legend to Fig. 1 of Test Method D1015 and Notes 2 and 3 of Test Method L, L'—Stopcock, ground for high vacuum, borosilicate glass.
D1015. M—Standard-taper ground-glass joint, 24/40 borosilicate glass.
D'— Brass cylinder, 254 mm (10 in.) in length, 47.6 mm (17⁄8 in.) in inside diameter, N—Receiver withdrawal, 36 mm in outside diameter, borosilicate glass.
(see D above). O—Dewar flask, 0.0005 m3 (1 pt) capacity, borosilicate glass.
E—Original sample. P—Connection to vacuum.
E'—Distilled sample. Q—Funnel with extension, 4 mm in inside diameter, borosilicate glass.
F, F'—Dewar flask, 0.0009 m3 (1 qt) capacity, borosilicate glass. R—Connection to drying tube, borosilicate glass.

FIG. 4 Apparatus for Simple Vacuum Distillation

Test Method D1015), letting the temperature as read on the 9.7 For isobutane, the freezing point for zero impurity, in air
platinum thermometer reach about −80 °C when all the sample at 1 atm, is:
has been collected. t f 0 5 2159.605 °C60.025 °C (6)
9.4 When 50 mL of liquid (temperature about −80 °C) has
been collected in the condensing tube, close the valve K (Fig. and the cryoscopic constants are:
1) and allow the liquid which had collected at I to warm and A 5 0.04234 mole fraction/°C and (7)
transfer to the condensing tube (Note 4). Replace the attaching B 5 0.0057 mole fraction/°C. (8)
tubes, G and D , on the condensing tube by caps. The liquid
sample is now ready for introduction into the freezing tube (O 9.8 The cryoscopic constants given in 9.7 are applicable to
in Fig. 1 of Test Method D1015). samples of isobutane having a purity of about 95 mole % or
better, with no one impurity present in an amount that exceeds
9.5 When the temperature of the platinum thermometer is its eutectic composition with the major component.
near −80 °C, remove the condensing tube (E in Fig. 1) from the
Dewar flask. Wrap a cloth around the upper portion of the 9.9 The estimated uncertainty in the calculated value of the
condensing tube (for ease of handling and for preventing the purity is as follows, in mole %:
refrigerating liquid from contaminating the sample on Calculated Purity, Uncertainty, plus or
mole % minus, mole %
pouring), and after removing the caps on the condensing tube, Over 99.5 0.10
raise the stopper holding the platinum thermometer, and pour 99.0 to 99.5 0.11
the sample through the tapered male outlet of the condensing 98 to 99 0.12
97 to 98 0.14
tube into the freezing tube (O in Fig. 1 of Test Method D1015). 96 to 97 0.16
Quickly replace the stopper holding the platinum thermometer 95 to 96 0.20
and start the stirrer, with dry air flowing into the upper portion
of the freezing tube through M (Fig. 1 of Test Method D1015). 10. n-Pentane (Warning —Extremely flammable liquid.
9.6 Because of the fact that the material is normally gaseous Harmful if inhaled. Vapors can cause flash fire.)
at room temperature, care should be taken in disposing of the 10.1 Determine the freezing point from freezing curves with
sample safely. the cage stirrer, with a cooling bath of liquid nitrogen (or liquid

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
5
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the 11.4 The cryoscopic constants given in 11.3 are applicable
liquid near the freezing point, and with crystallization induced to samples of isopentane having a purity of about 95 mole % or
immediately below the freezing point by means of a cold rod. better, with the usual impurities and with no one impurity
present in an amount which exceeds the composition of the
10.2 To obtain the sample, cool the container and n-pentane
eutectic with the major component.
to near 0 °C and transfer a sample of about 60 mL (liquid at the
given temperature) to a graduated cylinder which has been kept 11.5 The estimated uncertainty in the calculated value of the
refrigerated slightly below 0 °C. The sample is now ready for purity is as follows, in mole %:
introduction into the freezing tube, which should be precooled Calculated Purity, Uncertainty, plus or
to near −80 °C. mole % minus, mole %
Over 99.5 0.07
10.3 For n-pentane, the freezing point for zero impurity, in 99.0 to 99.5 0.08
air at 1 atm, is as follows: 98 to 99 0.09
97 to 98 0.10
t f 0 5 2129.730 °C60.015 °C (9) 96 to 97 0.12
95 to 96 0.14
and the cryoscopic constants are:
12. n-Hexane (Warning—Extremely flammable. Harmful if
A 5 0.04906 mole fraction/°C and (10)
inhaled. Can produce nerve cell damage. Vapors can
B 5 0.0042 mole fraction/°C. (11) cause flash fire.)
10.4 The cryoscopic constants given in 10.3 are applicable 12.1 Determine the freezing point from freezing curves with
to samples of n-pentane having a purity of about 95 mole % or the cage stirrer, with a cooling bath of liquid nitrogen (or liquid
better, with the usual impurities and with no one impurity air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the
present in an amount that exceeds the composition of its liquid near the freezing point and with crystallization induced
eutectic with the major component. immediately below the freezing point by means of a cold rod.
10.5 The estimated uncertainty in the calculated value of the 12.2 Obtain a sample of 50 mL (measured at room tempera-
purity is as follows, in mole %: ture) directly from its original container by means of a pipet or
Calculated Purity, Uncertainty, plus or by pouring into a graduated cylinder.
mole % minus, mole %
Over 99.5 0.07 12.3 For n-hexane, the freezing point for zero impurity, in
99.0 to 99.5 0.08
98 to 99 0.09 air at 1 atm, is as follows:
97 to 98 0.10 t f 0 5 295.322 °C60.010 °C (15)
96 to 97 0.12
95 to 96 0.14
and the cryoscopic constants are:
11. Isopentane (Warning—Extremely flammable liquid. A 5 0.04956 mole fraction/°C and (16)
Harmful if inhaled. Vapors can cause flash fire.) B 5 0.0039 mole fraction/°C. (17)
11.1 Determine the freezing point from melting curves with 12.4 The cryoscopic constants given in 12.3 are applicable
the double helix stirrer, with a cooling bath of liquid nitrogen to samples of n-hexane having a purity of about 95 mole % or
(or liquid air) to obtain the slurry of crystals and liquid, and a better, with the usual impurities and with no one impurity
warming bath of carbon dioxide refrigerant, with a cooling rate present in an amount that exceeds the composition of its
of 0.3 °C ⁄min to 0.8 °C ⁄min for the liquid near the freezing eutectic with the major component.
point and with crystallization induced immediately below the
freezing point, by seeding with crystals. (Crystallization may 12.5 The estimated uncertainty in the calculated value of the
also be induced with a cold rod, but the recovery from purity is as follows, in mole %:
undercooling will not be as rapid.) Calculated Purity, Uncertainty, plus or
mole % minus, mole %
11.2 To obtain a sample, cool the container and isopentane Over 99.5 0.05
to near 0 °C and transfer a sample of about 65 mL (liquid at the 99.0 to 99.5 0.06
98 to 99 0.07
given temperature) to a graduated cylinder which has been kept 97 to 98 0.08
refrigerated slightly below 0 °C. The sample is now ready for 96 to 97 0.10
introduction into the freezing tube which should be precooled 95 to 96 0.12

to near −80 °C.


13. n-Heptane (Warning —Flammable. Harmful if
11.3 For isopentane, the freezing point for zero impurity, in inhaled.)
air at 1 atm, is as follows:
13.1 Determining the freezing point from freezing curves
t f 0 5 2159.905 °C60.015 °C (12) with the cage stirrer, with a cooling bath of liquid nitrogen (or
and the cryoscopic constants are: liquid air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for
the liquid near the freezing point, and with crystallization
A 5 0.04829 mole fraction/°C and (13) induced immediately below the freezing point by means of a
B 5 0.0058 mole fraction/°C. (14) cold rod.

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
6
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
13.2 Obtain a sample of 50 mL (measured at room tempera- 15. 2,2,4-Trimethylpentane (Warning—Extremely
ture) directly from its original container by means of a pipet or flammable. Harmful if inhaled. Vapors can cause flash
by pouring into a graduated cylinder. fire.)
13.3 For n-heptane, the freezing point for zero impurity, in 15.1 For samples having a purity greater than about 99.5
air at 1 atm, is: mole %, determine the freezing point from melting curves with
t f 0 5 290.581 °C60.010 °C (18)
the cage stirrer, with a cooling bath of liquid nitrogen (or liquid
air), and a warming bath of solid carbon dioxide refrigerant,
and the cryoscopic constants are: with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the liquid
A 5 0.05065 mole fraction/°C and (19)
near the freezing point and with crystallization induced imme-
diately below the freezing point by means of a cold rod.
B 5 0.0033 mole fraction/°C. (20)
15.2 For samples having a purity less than about 99.5
13.4 The cryoscopic constants given in 13.3 are applicable mole %, determine the freezing point from freezing curves
to samples of n-heptane having a purity of about 95 mole % or with the cage stirrer, with a cooling bath of liquid nitrogen (or
better, with the usual impurities and with no one impurity liquid air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for
present in an amount that exceeds the composition of its the liquid near the freezing point, and with crystallization
eutectic with the major component. induced immediately below the freezing point by means of a
13.5 The estimated uncertainty in the calculated value of the cold rod.
purity is as follows, in mole %: 15.3 Obtain a sample of 50 mL (measured at room tempera-
Calculated Purity, Uncertainty, plus or minus, ture) directly from its original container by means of pipet or
mole % mole % by pouring into a graduated cylinder.
Over 99.5 0.05
99.0 to 99.5 0.06 15.4 For 2,2,4-trimethylpentane, the freezing point for zero
98 to 99 0.07
97 to 98 0.08
impurity, in air at 1 atm, is as follows:
96 to 97 0.10 t f 0 5 2107.373 °C60.010 °C (24)
95 to 96 0.12
and the cryoscopic constants are:
14. n-Octane (Warning —Flammable. Harmful if inhaled.)
A 5 0.04032 mole fraction/°C and (25)
14.1 Determine the freezing point from freezing curves with B 5 0.0043 mole fraction/°C. (26)
the cage stirrer, with a cooling bath of carbon dioxide refrig-
erant at a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the 15.5 The cryoscopic constants given in 15.4 are applicable
liquid near the freezing point, and with crystallization induced to samples of 2,2,4-trimethylpentane having a purity of about
immediately below the freezing point by means of a cold rod. 95 mole % or better, with the usual impurities and with no one
impurity present in an amount that exceeds the composition of
14.2 Obtain a sample of 50 mL (measured at room tempera- its eutectic with the major component.
ture) directly from its original container by means of a pipet or
by pouring into a graduated cylinder. 15.6 The estimated uncertainty in the calculated value of the
purity is as follows, in mole %:
14.3 For n-octane the freezing point for zero impurity, in air Calculated Purity, Uncertainty, plus or
at 1 atm, is as follows: mole % minus, mole %
Over 99.5 0.05
t f 0 5 256.764 °C60.010 °C (21) 99.0 to 99.5 0.06
98 to 99 0.07
and the cryoscopic constants are: 97 to 98 0.08
96 to 97 0.10
A 5 0.05329 mole fraction/°C and (22) 95 to 96 0.12
B 5 0.0031 mole fraction/°C. (23)
16. Methylcyclohexane (Warning—Flammable. Harmful if
14.4 The cryoscopic constants given in 14.3 are applicable inhaled.)
to samples of n-octane having a purity of about 95 mole % or
better, with the usual impurities and with no impurity present 16.1 Determine the freezing point from melting curves with
in an amount that exceeds the composition of its eutectic with the double helix stirrer, with a cooling bath of liquid nitrogen
the major component. (or liquid air) to obtain the slurry of crystals and liquid, and a
warming bath of carbon dioxide refrigerant, with a cooling rate
14.5 The estimated uncertainty in the calculated value of the of 0.3 °C ⁄min to 0.8 °C ⁄min for the liquid near the freezing
purity is as follows, in mole %: point and with crystallization induced immediately below the
Calculated Purity, Uncertainty, plus or minus, freezing point by seeding with crystals. (Crystallization may
mole % mole %
Over 99.5 0.05
also be induced with a cold rod, but the recovery from
99.0 to 99.5 0.06 undercooling will not be as rapid.)
98 to 99 0.07
97 to 98 0.08 16.2 Obtain a sample of 60 mL (measured at room tempera-
96 to 97 0.10 ture) directly from the original container by pouring into a
95 to 96 0.12 graduated cylinder.

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
7
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
16.3 For methylcyclohexane, the freezing point for zero 17.5 When the temperature of the platinum thermometer is
impurity, in air at 1 atm, is as follows: near −80 °C, remove the condensing tube (E in Fig. 1) from the
t f 0 5 2126.596 °C60.015 °C (27) Dewar flask. Wrap a cloth around the upper portion of the
condensing tube (for ease of handling and for preventing the
and the cryoscopic constants are: refrigerating liquid from contaminating the sample on
A 5 0.03779 mole fraction/°C and (28) pouring), and after removing the caps on the condensing tube,
raise the stopper holding the platinum thermometer, and pour
A 5 0.0032 mole fraction/°C. (29)
the sample through the tapered male outlet of the condensing
16.4 The cryoscopic constants given in 16.3 are applicable tube into the freezing tube (O in Fig. 1 of Test Method D1015).
to samples of methylcyclohexane having a purity of about 95 Quickly replace the stopper holding the platinum thermometer
mole % or better, with the usual impurities and with no one and start the stirrer, with dry air flowing into the upper portion
impurity present in an amount that exceeds the composition of of the freezing tube through M (Fig. 1 of Test Method D1015).
the eutectic with the major component.
17.6 Because of the fact that the material is normally
16.5 The estimated uncertainty in the calculated value of the gaseous at room temperature, care should be taken in disposing
purity is as follows, in mole %: of the sample safely.
Calculated Purity, Uncertainty, plus or
mole % minus, mole %
17.7 For isobutene, the freezing point for zero impurity, in
Over 99.5 0.05 air at 1 atm, is as follows:
99.0 to 99.5 0.06
98 to 99 0.07 t f 0 5 2140.337 °C60.020 °C (30)
97 to 98 0.08
96 to 97 0.10 and the cryoscopic constants are:
95 to 96 0.12
A 5 0.04044 mole fraction/°C and (31)
6 B 5 0.005 mole fraction/°C. (32)
17. Isobutene (Warning—Extremely flammable liquefied
gas under pressure. Vapor reduces oxygen available for 17.8 The cryoscopic constants given in 17.7 are applicable
breathing.) to samples of isobutene having a purity of about 95 mole % or
17.1 Determine the freezing point from freezing curves, better, with no one impurity present in an amount that exceeds
with the cage stirrer, with a cooling bath of liquid nitrogen (or its eutectic composition with the major component.
liquid air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for 17.9 The estimated uncertainty in the calculated value of the
the liquid near the freezing point, and with crystallization purity is as follows, in mole %:
induced immediately below the freezing point by means of a Calculated Purity, Uncertainty, plus or
cold rod. mole % minus, mole %
Over 99.5 0.08
17.2 Obtain the samples as follows: Assemble the apparatus 99.0 to 99.5 0.09
for obtaining the sample as shown in Fig. 1, but with no 98 to 99 0.10
97 to 98 0.12
lubricant on the ground-glass joints and with the valve at the 96 to 97 0.15
bottom of the cylinder, so that sampling is from the liquid 95 to 96 0.20
phase. Attach to C an absorption tube containing anhydrous
calcium sulfate or other suitable desiccant (except magnesium 18. 1,3-Butadiene6 (Warning—Extremely flammable
perchlorate) so that water is not introduced into the system liquefied gas under pressure. May form explosive
(Note 3). Fill the flask F with the carbon dioxide refrigerant to peroxides upon exposure to air. Harmful if inhaled.
within about 51 mm (2 in.) of the top. After about 20 min or Irritating to eyes, skin, and mucous membranes.)
30 min, when the system will have cooled sufficiently, remove 18.1 Determine the freezing point from freezing curves with
the absorption tube and begin the collection of liquid isobutene the cage stirrer, with a cooling bath of liquid nitrogen (or liquid
by opening the valve K and adjusting the needle valve J so that air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the
the sample is collected at a rate of 1 mL to 2 mL (liquid)/min liquid near the freezing point and with crystallization induced
in the condensing tube E. immediately below the freezing point by means of a cold rod.
17.3 Assemble the freezing point apparatus. Place the cool- 18.2 Obtain the samples as follows: Assemble the apparatus
ing bath in position around the freezing tube (O in Fig. 1 of for obtaining the sample as shown in Fig. 1, but with no
Test Method D1015), letting the temperature as read on the lubricant on the ground-glass joints and with the valve at the
platinum thermometer reach about −80 °C when all the sample bottom of the cylinder, so that sampling is from the liquid
has been collected. phase. Attach to C an absorption tube containing anhydrous
17.4 When 50 mL of liquid (temperature about −80 °C) has calcium sulfate or other suitable desiccant (except magnesium
been collected in the condensing tube, close the valve K (Fig. perchlorate) so that water is not introduced into the system
1) and allow the liquid which has collected at I to warm and (Note 3). Fill the flask F with the carbon dioxide refrigerant to
transfer to the condensing tube (Note 4). Replace the attaching within about 51 mm (2 in.) of the top. After about 20 min or
tubes G and D on the condensing tube by caps. The liquid 30 min, when the system will have cooled sufficiently, remove
sample is now ready for introduction into the freezing tube (O the absorption tube and begin the collection of liquid 1,3-
in Fig. 1 of Test Method D1015). butadiene by opening the valve K and adjusting the needle

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
8
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
valve J so that the sample is collected at a rate of 1 mL to 2 mL platinum thermometer and start the stirrer, with dry air flowing
(liquid)/min in the condensing tube E. into the upper portion of the freezing tube through M (Fig. 1 of
Test Method D1015).
18.3 Assemble the freezing point apparatus. Place the cool-
ing bath in position around the freezing tube (O in Fig. 1 of 18.7 Because of the fact that the material is normally
Test Method D1015), letting the temperature as read on the gaseous at room temperature, care should be taken in disposing
platinum thermometer reach about −80 °C when all the sample of the sample safely.
has been collected. 18.8 For 1,3-butadiene, the freezing point for zero impurity,
in air at 1 atm, is
18.4 When 50 mL of liquid (temperature about −80 °C) has
been collected in the condensing tube, close the valve K (Fig. t f 0 5 2108.902 °C60.010 °C (33)
1) and allow the liquid, which has collected at I, to warm and and the cryoscopic constants are:
transfer to the condensing tube (Note 4). Replace the attaching
tubes G and D on the condensing tube by caps. The liquid A 5 0.03560 mole fraction/°C and (34)
sample is now ready for introduction into the freezing tube ( O B 5 0.0053 mole fraction/°C. (35)
in Fig. 1 of Test Method D1015). 18.9 The cryoscopic constants given in 18.8 are applicable
18.5 In some cases, it will be desirable to remove the dimer, to samples of 1,3-butadiene having a purity of about 95 mole %
other C8 hydrocarbons, and higher polymer from the sample of or better, with no one impurity present in an amount that
1,3-butadiene before determining the purity. For this removal, exceeds its eutectic composition with the major component.
the procedure is as follows: Assemble the apparatus shown in 18.10 The estimated uncertainty in the calculated value of
Fig. 2 with a small amount (10 ppm to 100 ppm) of tertiary the purity is as follows, in mole %:
butyl catechol or other suitable inhibitor placed in the bottom Calculated Purity, Uncertainty, plus or
of the distilling tube E, with no lubricant on the ground-glass mole % minus, mole %
Over 99.5 0.05
joints. It is also desirable to place at the bottom of the flask a 99.0 to 99.5 0.06
piece of carborundum or other suitable material to prevent 98 to 99 0.07
bumping. Make a connection to the atmosphere through an 97 to 98 0.08
96 to 97 0.09
absorption tube (as previously described in this section) at H' 95 to 96 0.10
so that entering air is freed of carbon dioxide and water. Place
a bath containing carbon dioxide refrigerant around the distill- 19. Isoprene (2-Methyl-1,3-Butadiene)6 (Warning—
ing tube E, and also around the receiver J so that the small Extremely flammable liquefied gas under pressure. Vapor
entrance and exit tubes of J are covered with at least 5 cm of reduces oxygen available for breathing.)
the bath. After about 20 min to 30 min, when the system will 19.1 For samples having a purity greater than about 98
have precooled sufficiently, disconnect the connection to the mole %, determine the freezing point from melting curves,
atmosphere at H', remove the cap F, and introduce the liquid with the double helical stirrer, with a cooling bath of liquid
butadiene (temperature near −80 °C) by pouring through a nitrogen (or liquid air), and a warming bath of carbon dioxide
precooled funnel (such as Q in Fig. 4 which may be cooled refrigerant, with the jacket of the freezing tube open to the high
without contamination by liquid air or liquid nitrogen) into the vacuum system during the entire melting part of the curve, with
distilling tube. Grease the cap F and replace immediately after a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the liquid near
the introduction of the sample. Then distill the material by the freezing point and with crystallization induced immediately
removing the bath from the distilling tube and allowing it to below the freezing point by means of a cold rod.
warm in contact with the air of the room. Distillation is 19.2 For samples having a purity less than about 98 mole %,
complete when the distilling tube has warmed to room tem- determine the freezing point from freezing curves, with either
perature. Disconnect the receiver with the bath around it, cap it the aluminum cage stirrer or the double helical stirrer, with a
at H and H', and transfer 50 mL (liquid at about −80 °C) of the cooling bath of liquid nitrogen (or liquid air), with a cooling
liquid butadiene to the freezing tube by pouring through I in a rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the liquid near the
manner similar to that described for a sample collected in the freezing point and with crystallization induced immediately
condensing tube. below the freezing point by means of a cold rod.
18.6 When the temperature of the platinum thermometer is 19.3 The method of obtaining the sample is as follows:
near −80 °C, remove the condensing tube (E in Fig. 1) or the When the material is in a cylinder, assemble the apparatus
receiver (J in Fig. 2) from the Dewar. Wrap a cloth around the shown in Fig. 1, with a suitable lubricant on the ground-glass
upper portion of the condensing tube or receiver (for ease of joints, and with the valve below the body of the cylinder so that
handling and for preventing the refrigerating liquid from the sample is obtained from the liquid phase. Evacuate the
contaminating the sample on pouring), and after removing the system by connecting, through heavy-walled tubing, the open-
caps on the condensing tube or receiver, raise the stopper ing B to a vacuum line. After evacuation, close the stopcock A
holding the platinum thermometer, and pour the sample to the outlets B and C, and collect the sample of isoprene
through the tapered male outlet of the condensing tube or the (55 mL, liquid, at about −80 °C) in the refrigerated condensing
exit tube I of the receiver into the freezing tube (O in Fig. 1 of tube E, in which was previously placed a small amount (about
Test Method D1015). Quickly replace the stopper holding the 10 ppm to 100 ppm) of tertiary butyl catechol or other suitable

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
9
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
inhibitor. The sample as thus collected will contain the bulk of condensing tube E (Fig. 1), which serves as a trap, and also
any dimer present in the original material. The sample, replace the carbon dioxide refrigerant around the distilling tube
including substantially all of the dimer, is now ready for E (Fig. 4) with liquid nitrogen or liquid air. After the isoprene
introduction into the freezing tube, which should be precooled has solidified, evacuate the system by opening H and H' to the
to near −100 °C. When the isoprene is contained in capped vacuum system. Close the stopcocks H and H' and remove the
bottles or sealed ampoules, cool the container and isoprene to bath from E to allow the material to melt and release dissolved
near 0 °C and transfer a sample of about 65 mL (liquid at the air. Crystallize the material again and evacuate the system as
given temperature) to a graduated cylinder which has been kept before. Repeat the process again, if necessary, to remove
refrigerated slightly below 0 °C. The sample, including such substantially all the air. (If any hydrocarbon has been caught in
amount of dimer and higher polymer as was originally present, the trap J, it should be distilled back into the tube E, with the
is now ready for introduction into the freezing tube, which stopcock H open and H' closed.) Distill the material into E' by
should be precooled to near −100 °C. placing carbon dioxide refrigerant around the receiver and a
19.4 In most cases, it will be desirable to remove the dimer water-ice bath around E (after the latter has warmed to near
and higher polymer from the sample of isoprene before 0 °C). Halt the distillation when the transfer of material into the
determining the purity. For this removal, the procedure is as receiver has substantially halted, by admitting air (freed of
follows: Assemble the apparatus shown in Fig. 3 with no water and carbon dioxide) into the system through RH" H'H.
lubricant on the ground-glass joints D and D'. Place a small Remove the sample from the receiving tube E with the
amount of tertiary butyl catechol or other suitable inhibitor withdrawal receiver N. Evacuate the system LMNL, with L'
(about 10 ppm to 100 ppm) in the receiver F and a larger open and L closed, through P and then close the stopcock L'.
amount (about 100 ppm to 1000 ppm) in the distilling flask B. Surround the receiver N' by carbon dioxide refrigerant. Re-
It is also desirable to place at the bottom of the flask B a piece move the material by inserting the inlet tube at L into the
of carborundum or other suitable material to prevent bumping. receiver and then opening the stopcock L. This procedure
Place a cooling bath of water-ice around the distilling flask B avoids loss by evaporation. Then introduce the material into
and a bath containing carbon dioxide refrigerant around the the freezing tube, previously precooled to near −100 °C, by
receiver F. Make a connection to the atmosphere at D' through pouring through the tapered joint at M. For the procedure for
which the air is first freed of carbon dioxide and water, using introducing the sample into the tube, see 18.6 on 1,3-butadiene.
a tube containing Ascarite and anhydrous calcium sulfate or 19.6 For isoprene (2-methyl-1,3-butadiene), the freezing
other suitable desiccant. Introduce the sample (at 0 °C) into the point for zero impurity, in air at 1 atm, is:
flask B, place the cap A in position with a suitable lubricant t f 0 5 2145.964 °C60.020 °C (36)
between the grindings, and remove the connection to the
atmosphere at D'. Place a water bath (at 40 °C to 50 °C) around and the cryoscopic constants are:
the flask B and distill the material into F. Stop the distillation A 5 0.0330 mole fraction/°C and (37)
when a small residue remains in B with the water bath at 50 °C.
Detach the receiver F at D and cap at D and D' with the bath B 5 0.0030 mole fraction/°C. (38)
containing carbon dioxide refrigerant still surrounding it. 19.7 The cryoscopic constants given in 19.6 are applicable
Remove the sample, with the upper portion of the container to samples of isoprene having a purity of about 95 mole % or
wrapped with a cloth (for ease of handling and for preventing better, with no one impurity present in an amount that exceeds
the refrigerating liquid from contaminating the sample on the eutectic composition with the major component.
pouring), from the flask E, remove the caps and introduce the
sample into the freezing tube, previously precooled to near 19.8 The estimated uncertainty in the calculated value of the
−100 °C, by pouring through D'. For the procedure for intro- purity is as follows, in mole %:
ducing the sample into the tube, see 18.6 on 1,3-butadiene. Calculated Purity, Uncertainty, plus or
mole % minus, mole %
19.5 If the sample contains a very large amount of dimer Over 99.5 0.08
99.0 to 99.5 0.10
and polymer, then the simple preceding procedure outlined will 98 to 99 0.12
not suffice because the required distilling temperature will be 97 to 98 0.15
too high, and a more complicated procedure is used, as follows: 96 to 97 0.20
95 to 96 0.25
Assemble the apparatus shown in Fig. 4, with inhibitor placed
in the distilling tube and receiver (plus some carborundum in
20. Benzene (Warning—Poison. Carcinogen. Harmful or
the distilling tube to prevent bumping) as previously described
fatal if swallowed. Extremely flammable. Vapors can
in 19.4, and with all the ground joints except that at A
cause flash fire. Vapor harmful, can be absorbed through
lubricated. Place a cooling bath of carbon dioxide refrigerant
skin.)
around the distilling tube E. Permit air, freed of carbon dioxide
and water, to enter the system through RH" H'H in order to 20.1 Determine the freezing point from freezing curves with
compensate for the change in volume. When the sample is the cage stirrer, with a cooling bath of carbon dioxide
cooled, remove the cap A and introduce the sample through the refrigerant, with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for
funnel Q, which has been precooled with liquid air or liquid the liquid near the freezing point and with crystallization
nitrogen. Then lubricate the cap A and close the stopcocks H, induced immediately below the freezing point by means of a
H', and H". Place liquid air or liquid nitrogen around the cold rod.

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
10
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
20.2 Obtain a sample of 50 mL (measured at room tempera- Calculated Purity, Uncertainty, plus or
ture) directly from the original container by means of a pipet or mole % minus, mole %
Over 99.5 0.03
by pouring into a graduated cylinder. Then filter the sample 99.0 to 99.5 0.04
directly into the freezing point tube (O in Fig. 1 of Test Method 98 to 99 0.05
D1015), through silica gel to remove water. See 9.3, and Fig. 97 to 98 0.06
96 to 97 0.08
5 of Test Method D1015. 95 to 96 0.10
20.3 For benzene, the freezing point for zero impurity, in air
22. Ethylbenzene (Warning—Flammable. Vapor harmful.)
at 1 atm, is:
22.1 Determine the freezing point from melting curves with
t f 0 5 5.531 °C60.010 °C (39)
the cage stirrer, with a cooling bath of liquid nitrogen (or liquid
and the cryoscopic constants are: air) to obtain the slurry of crystals and liquid, and a warming
bath of carbon dioxide refrigerant, with a cooling rate of
A 5 0.01523 mole fraction/°C and (40)
0.3 °C ⁄min to 0.8 °C ⁄min for the liquid near the freezing point,
B 5 0.0032 mole fraction/°C. (41) and with crystallization induced immediately below the freez-
20.4 The cryoscopic constants given in 20.3 are applicable ing point by seeding with crystals. (Crystallization may also be
to samples of benzene having a purity of about 95 mole % or induced with a cold rod, but the recovery from undercooling
better, with the usual impurities and with no one impurity will not be as rapid.)
present in an amount that exceeds the composition of its 22.2 Obtain a sample of 50 mL (measured at room tempera-
eutectic with the major component. ture) directly from its original container by means of a pipet or
20.5 The estimated uncertainty in the calculated value of the by pouring into a graduated cylinder.
purity is as follows, in mole %: 22.3 For ethylbenzene, the freezing point for zero impurity,
Calculated Purity, Uncertainty, plus or in air at 1 atm, is:
mole % minus, mole %
Over 99.5 0.02 t f 0 5 294.949 °C60.015 °C (45)
99.0 to 99.5 0.03
98 to 99 0.04 and the cryoscopic constants are:
97 to 98 0.05
96 to 97 0.06 A 5 0.03471 mole fraction/°C and (46)
95 to 96 0.08 B 5 0.0029 mole fraction/°C. (47)

21. Toluene (Warning—Flammable. Vapor harmful.) 22.4 The cryoscopic constants given in 22.3 are applicable
to samples of ethylbenzene having a purity of about 95 mole %
21.1 Determine the freezing point from freezing curves with or better, with the usual impurities and with no one impurity
the cage stirrer, with a cooling bath of liquid nitrogen (or liquid present in an amount that exceeds the composition of its
air), with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the eutectic with the major component.
liquid near the freezing point, and with crystallization induced
immediately below the freezing point by means of a cold rod. 22.5 The estimated uncertainty in the calculated value of the
purity is as follows, in mole %:
21.2 A sample of 50 mL (measured at room temperature) is Calculated Purity, Uncertainty, plus or
obtained directly from its original container by means of a mole % minus, mole %
pipet or by pouring into a graduated cylinder. Over 99.5 0.05
99.0 to 99.5 0.06
21.3 For toluene, the freezing point for zero impurity, in air 98 to 99 0.08
97 to 98 0.10
at 1 atm, is: 96 to 97 0.12
t f 0 5 294.965 °C60.012 °C (42) 95 to 96 0.14

and the cryoscopic constants are: 23. o-Xylene (Warning—Flammable. Vapor harmful.)
A 5 0.02508 mole fraction/°C and (43) 23.1 The freezing point is determined from freezing curves
with the cage stirrer, with a cooling bath of carbon dioxide
B 5 0.0019 mole fraction/°C. (44)
refrigerant, with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for
21.4 The cryoscopic constants given in 21.3 are applicable the liquid near the freezing point, and with crystallization
to samples of toluene having a purity of about 95 mole % or induced immediately below the freezing point by seeding with
better, with the usual impurities and with no one impurity crystals. (Crystallization may also be induced with a cold rod,
present in an amount that exceeds the composition of its but the recovery from undercooling will not be as rapid.)
eutectic with the major component. 23.2 A sample of 50 mL (measured at room temperature) is
21.5 The estimated uncertainty in the calculated value of the obtained directly from its original container by means of a
purity is as follows, in mole %: pipet or by pouring into a graduated cylinder.

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
11
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
23.3 For o-xylene, the freezing point for zero impurity, in refrigerant, with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for
air at 1 atm, is: the liquid near the freezing point, and with crystallization
t f 0 5 225.167 °C60.005 °C (48) induced immediately below the freezing point, by seeding with
crystals. (Crystallization may also be induced with a cold rod,
and the cryoscopic constants are: but the recovery from undercooling will not be as rapid.)
A 5 0.02659 mole fraction/°C and (49) 25.2 Obtain a sample of 50 mL (measured at room tempera-
B 5 0.0030 mole fraction/°C. (50) ture) directly from the original container by means of a pipet or
23.4 The cryoscopic constants given in 23.3 are applicable by pouring into a graduated cylinder. The sample is then
to samples of o-xylene having a purity of about 95 mole % or filtered directly into the freezing point tube, (O in Fig. 1 of Test
better, with the usual impurities and with no one impurity Method D1015), through silica gel to remove water. See 9.3
present in an amount that exceeds the composition of its and Fig. 5 of Test Method D1015.
eutectic with the major component. 25.3 For p-xylene, the freezing point for zero impurity, in
23.5 The estimated uncertainty in the calculated value of the air at 1 atm, is:
purity is as follows, in mole %: t f 0 5 13.258 °C60.012 °C (54)
Calculated Purity, Uncertainty, plus or
mole % minus, mole %
and the cryoscopic constants are:
Over 99.5 0.02 A 5 0.02509 mole fraction/°C and (55)
99.0 to 99.5 0.03
98 to 99 0.04 B 5 0.0028 mole fraction/°C. (56)
97 to 98 0.05
96 to 97 0.06 25.4 The cryoscopic constants given in 25.3 are applicable
95 to 96 0.08 to samples of p-xylene having a purity of about 95 mole % or
24. m-Xylene (Warning —Flammable. Vapor harmful.) better, with the usual impurities and with no one impurity
present in an amount that exceeds the composition of its
24.1 Determine the freezing point from freezing curves with eutectic with the major component.
the cage stirrer, with a cooling bath of solid carbon dioxide
refrigerant, with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for 25.5 The estimated uncertainty in the calculated value of the
the liquid near the freezing point, and with crystallization purity is as follows, in mole %:
induced immediately below the freezing point by seeding with Calculated Purity, Uncertainty, plus or
crystals. (Crystallization may also be induced with a cold rod, mole % minus, mole %
Over 99.5 0.03
but the recovery from undercooling will not be as rapid.) 99.0 to 99.5 0.04
98 to 99 0.05
24.2 Obtain a sample of 50 mL (measured at room tempera- 97 to 98 0.06
ture) directly from its original container by means of a pipet or 96 to 97 0.08
by pouring into a graduated cylinder. 95 to 96 0.10

24.3 For m-xylene, the freezing point for zero impurity, in


26. Styrene (Ethenylbenzene)6 (Warning—Flammable.
air at 1 atm, is:
Vapor harmful.)
t f 0 5 247.844 °C60.020 °C (51)
26.1 Determine the freezing point from freezing curves with
and the cryoscopic constants are: the cage stirrer, with cooling bath of carbon dioxide refrigerant,
A 5 0.02741 mole fraction/°C and (52)
with a cooling rate of 0.3 °C ⁄min to 0.8 °C ⁄min for the liquid
near the freezing point, and with crystallization induced
B 5 0.0027 mole fraction/°C. (53) immediately below the freezing point by means of a cold rod.
24.4 The cryoscopic constants given in 24.3 are applicable 26.2 Obtain a sample of 50 mL (measured at room tempera-
to samples of m-xylene having a purity of about 95 mole % or ture) directly from the original container by means of a pipet or
better, with the usual impurities and with no one impurity by pouring into a graduated cylinder.
present in an amount that exceeds the composition of its
eutectic with the major component. 26.3 If the previous treatment or storage condition of
material was such that dimerization or polymerization may
24.5 The estimated uncertainty in the calculated value of the
have occurred, the dimer or polymer should be removed by a
purity is as follows, in mole %:
simple vacuum distillation (Fig. 4), using the same procedure
Calculated Purity, Uncertainty, plus or as described under isoprene (see 19.5) except that carbon
mole % minus, mole %
Over 99.5 0.05 dioxide refrigerant is used to refrigerate the receiver and the
99.0 to 99.5 0.06 sample is distilled at room temperature.
98 to 99 0.07
97 to 98 0.08 26.4 For styrene, the freezing point for zero impurity, in air
96 to 97 0.10 at 1 atm, is:
95 to 96 0.12
t f 0 5 230.610 °C60.008 °C (57)
25. p-Xylene (Warning —Flammable. Vapor harmful.)
25.1 Determine the freezing point from freezing curves with and the cryoscopic constants are:
the cage stirrer, with a cooling bath of carbon dioxide A 5 0.02365 mole fraction/°C and (58)

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
12
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.
D1016 − 05 (2015)
B 5 0.0044 mole fraction/°C. (59) 27. Precision and Bias
26.5 The cryoscopic constants given in 26.4 are applicable 27.1 Precision—The precision for this test method is gov-
to samples of styrene having a purity of not less than about 95 erned by the precision of Test Method D1015. Test Method
mole %, with the usual impurities and with no one impurity D1015 must be used for the freezing point determinations in
present in an amount that exceeds the composition of its this test method.
eutectic with the main component.
26.6 The estimated uncertainty in the calculated value of the 27.2 Bias—The bias for this test method is governed by the
purity is as follows, in mole %: bias of Test Method D1015. Test Method D1015 must be used
for the freezing point determinations in this test method.
Calculated Purity, Uncertainty, plus or
mole % minus, mole %
Over 99.5 0.04 28. Keywords
99.0 to 99.5 0.05
98 to 99 0.06 28.1 crystallization; freeze point; LPG; pure hydrocarbons;
97 to 98 0.07
96 to 97 0.08
purity
95 to 96 0.09

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.

This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/

Copyright by ASTM Int'l (all rights reserved); Fri Apr 5 05:44:28 EDT 2019
13
Downloaded/printed by
Fitri Muhamady (NULL) pursuant to License Agreement. No further reproductions authorized.

You might also like