ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR ENGINEER :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
TO BE USED FOR THE
1 SOLID CONCRETE BLOCKS SHEVY RETAINING WALL
COMPANY CONSTRUCTION
CONTRACTOR ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
TO BE USED FOR THE
1 SOLID CONCRETE BLOCKS GOMZIAN RETAINING WALL
COMPANY CONSTRUCTION
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Steel iron cover (Circular R: 0.3m ) Manhole cover 1
2 Steel iron cover (Rectangular internal dim: 0.75x0.4) Streets grates 1
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 concrete pipe =40cm R25(st.0-157) 1
2 = R27(st.83-199),R31(st.0-95) 1
3 = R30(st.47-147),R7a(st.41-157) 1
4 = R32(st.48-199),R39(st.31-100) 1
5 = R12(st.83-280) 1
7 = R33(st.48-95),R34(st.0-95),R36(st.30-95) 1
8 = R10(st.0-159),R23(st.30-95) 2 (Retest)
9 = R37(st.0-95),R26(st.0-100) 2 (Retest)
I certify that the above submitted items have been reviewed in
REMARKS BY SUPERVISOR ENGINEER : detail and are correct and in strict compliance with the contract
Drawings and specifications except as other wise stated.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Sewerage design for zone A,B,E Full design and details for sewerage for zone A,B,E
2
3
4
5
7
8
9
I certify that the above submitted items have been reviewed in
REMARKS BY SUPERVISOR ENGINEER : detail and are correct and in strict compliance with the contract
Drawings and specifications except as other wise stated.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Steel Bar Turkish 10mm, Required grade=420 3
2 Steel Bar Turkish 12mm, Required grade=420 3
3 Steel Bar Turkish 16mm, Required grade=420 3
4
5
7
8
9
I certify that the above submitted items have been reviewed in
REMARKS BY SUPERVISOR ENGINEER : detail and are correct and in strict compliance with the contract
Drawings and specifications except as other wise stated.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Steel iron cover (Circular R: 0.3m ) HOGER Manhole cover 1
2 Steel iron cover (Rectangular internal dim: 0.75x0.4) FACTORY Streets grates 1
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing for a typical cross section for the road
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Sewerage works-manholes
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Sewerage works-manholes
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details temporary pipe line profile for the
neighbour sewerage pipe
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Water stoper sample 1 hydrpholic strip 1
2 Water stoper sample 2 pvc sheet 1
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details R102 Sewerage Profile
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Sewerage Works-Manhole
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Zone-E, R53 sewerage profile
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Zone-E, R52 sewerage profile
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details R1 Box-culvert pirofile rev.#2
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details for Korean Village Water Supply Redesign
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Zone-E, R56,R71 sewerage profile
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Zone-E, R54 sewerage profile
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-E, R52,R74,R75,R76,
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Product data sheet for Sika Mono Top-612 Polymer Modified Repair Mortar
2 Cementitious Based Steel
Product data sheet for Sika Mono Top-610
Reinforcement Primer
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-E, R83
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-E, R61,R66,R88,R89,R93
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-E, R85
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-E, R82
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Concrete Pipes D=90 Zone-E 1
2 Concrete Pipes D=75 4
3 Concrete Pipes D=60 6
4 Concrete Pipes D=100 Zone A 2
5 Concrete Pipes D=75 1
6 Concrete Pipes D=60 2
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-A R100
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-E R81
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile
Zone E Profile
R55,R57,R58,R59,R60,R62,R63,R64
,R65,R67,R68,R69,R70,R72,R73,R7
7,R78
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Concrete Pipes D=75 S&H R75,R7 2
2 Concrete Pipes D=60 S&H R93,R85 1
3 Concrete Pipes D=40 S&H R53,R56,R62,R60,R61 3
4 Concrete Pipes D=60 S&H R53,R88 2
5 Concrete Pipes D=60 S&H R89 2
6
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Concrete Pipes D=75 S&H R100 3
2 Concrete Pipes D=60 S&H R100 2
3 Concrete Pipes D=60 S&H R53,R76 6
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R131
Box-culvert 1.2x1.5 internal dim.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone E Profile R84, R86, R90
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone E Profile R95,R96,R97
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone E Profile R94,R74
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and Design
Manholes for sewer pipes 90,100,120
cm dia. Internal dim. 1.5x1.2m
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Concrete Pipes D=40 S&H
R77,R76,R65,R63,R69,R72,R71,R73 8
,R70,R74,R81,R82,R85,R94,R67
2 Concrete Pipes D=60 S&H R85,R82 4
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 SOLID CONCRETE BLOCKS
To be used for sewerage manholes
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details for Korean Village Water Supply Redesign
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details (Rev. 1) R102 Sewerage Profile
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Concrete Pipes D=40 S&H R102,R101 2
2 Concrete Pipes D=75 S&H R101 3
3 Concrete Pipes D=100 S&H R101 1
4 Concrete Pipes D=60 S&H R131 3
5 Concrete Pipes D=75 S&H R131 3
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Standard specification for steel fiber reinforced sewer pipes For manufacturing steel fiber
reinforced concrete pipes
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone A Profile
R105,R106,R108,R109,R110,
R111,R112,R114,R115,R116
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details for sewerage profile,Zone E, R93,94,97 Chang the places for manholes and
inlets
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details for sewerage profile,Zone E, Chang the places for manholes and
R74,R27,R91,R90,R88,R86 inlets
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Chang the places for manholes and
Drawings and details for sewerage profile,Zone E, R86
inlets Rev.#2
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Sewerage plan zone A,E
Drawings and details for sewerage
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Chang the places for manholes and
Drawings and details for sewerage profile,Zone E, R3
inlets
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Chang the places for manholes and
Drawings and details for sewerage profile,Zone F, R29
inlets
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Chang the places for manholes and
Drawings and details for sewerage profile,Zone E, R78
inlets
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details for sewerage profile,Zone (Round About), Profile for the box-culvret
for Box-Culvert between R1-R131
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R132
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R135,R137
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile
R132A,R133,R138,R139
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile
R140,R141,R142,R143,R144,R145,R
146,R147,R148,R149
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile
R150,R151,R152,R153,R154,
R155,R156,R157,R158
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Septic-Tank Manhole ordinary
proposal
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details Sewerage plan zone B,F
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 CHROO Group Subcontractor for water ditribution
(Company profile was sent by letter Ref. No. network
14001/MLP/NT/15/021)
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Water suply works (Pipes) OHM (Germany) prd.st: SDR 17-PN 10, Quality:100%
PE100+RC, PAS 1075 TYPE 1
2 (Fittings) UNIDELTA (Italy)
3
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 DEN Co. Subcontractor for Electrical works
(Company profile was sent by letter Ref. No.
14001/MLP/NT/15/022)
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details (Profile) Redesign for the Levels of zone C
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile
for R100 - Zone-A Redesign (gullies and manholes)
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R134,R170,R162
R165
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R163
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details (Profile) Redesign for the Levels of zone D
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Retaining wall foundation Details for foundation of retaining
wall ( up to 1.1m wall height)
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 As per attached According to the attached technical
Electrical Material to be used for Electrical Network Installation
forms data.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R168,R169.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R171
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Proposal for Insitue Cast Gully Drwaings and details
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 SAND To be used for water supply pipes
installation
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Proposal for precast Manhall for Water Supply Valves Drwaings and details
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Water Pipe Warning Tape To be used over water supply
network pipes
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Implementation Schedule for the Electricity network Work Plan for Korean Village
2 Personal CV overhead electric network
3 Method statement.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details (Profile) Redesign for the Levels of zone C
Rev #2
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 SOLID CONCRETE BLOCKS To be used for sewerage manhole
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Proposal for precast Manhall for Water Supply Valves Drwaings and details
Rev. #2
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details Cross-section water supply pipe
arrangement in 2m walkway
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details Cross-section Water and Electric
supply arrangement in 2m walkway
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Electrical Materials for testing
Testing electrical matrials
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone B Profile R136
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details (Profile) Redesign for the Levels of zone D
Rev.#2
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details Cross-section water supply pipe
arrangement walkway
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and details Side-wall Cross-section for zone F
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1
PE-Pipes φ 90mm
PE-Pipes φ 110mm
PE-Pipes φ 160mm Gerodur PE-Pipes for Water Supply Network
PE-Pipes φ 180mm
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Concrete curing compound Curing compound to be used for
curing the kerb
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 BOQ for the Electrical Network Revised Bill of quantities
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and Details (Profile) R160,R176,R177,R180
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Change to design profile R27
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing and Details( profile ) R174, R175
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Change to design profile R38
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Work Schedule Program Work Schedule Program and S-curve
for infrastructure works up to 20th of
June 2015
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Road Profile (Re-design) Re-design for the roads R227,
R249,R388, R384,R381, R315, R301
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and Details for (Water works / Water tanks / Water Water Tanks 1417 m3
pumps) Water Tank Details (Inlets and
output structures)
Pumping station Details
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Water supply pipes (Lab testing) pipe dia. 160 mm
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 BOQ for the Water Network Bill of quantities
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Green Area connections Material Testing
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Water Supply Network - Lab Testing Results 160mm Diameter Rc Pipe test
results
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Progress Report & S-Curve Progress Report & S-Curve
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawing amendments Amendments to R1 road crossings
design
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Type A material Progress Report & S-Curve
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone E Profile R51, T12
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Design Submission (Elevated Water Tanks) Design Submission Documents
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-A, R101, R104
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Drawings and details ,sewerage profile Zone-B, R133b, R181
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Road profile Zone-B, R133a, R181
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Water Supply Network, "D90" Zone-B, R133, R181, R131
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :
ITEM
NAME OF ITEM MANUFACTURED DESCRIPTIONS No.
NO.
1 Water tank for Zones E & F Structural Calculations P,1-9
R.C. water tank BOQ P,10-11
P,12-40
Water supply network design
Structural drawings P,41-43
Pump room design P,44
Fencing P,45
Water tank Drawings P,46-50
Pumping station details P,51
Elavated water tank P,52-61
I certify that the above submitted items have been reviewed in
REMARKS BY SUPERVISOR ENGINEER : detail and are correct and in strict compliance with the contract
Drawings and specifications except as other wise stated.
CONTRACTOR'S ENGINEER :
RESIDENT ENGINEER COMMENTS :