The Controller tracks various error conditions which may occur on the connected Injectors
and displays warning notifications as appropriate. Common error conditions are described
in the following paragraphs.
Note: Commands cannot be initiated on the affected Slave Injector(s) when the Controller
indicates that communication has been lost.
his condition may be due to loss of power to the affected Slave Injector, disconnection of
the daisy-chain communication cable to that Injector, or by an internal hardware fault in the
unit.
Note: The error message indicating loss of communications with the Master Injector is also
displayed in this case.
If this error occurs check the integrity of the USB cable connection between the Controller
and the Master Injector.
This condition can be caused by a short circuit in the wiring to the radio, connection of
inappropriate equipment (e.g. plugging a 29V radio into a 56V injector), or by an internal
fault in the radio itself.
When a fault condition is detected on an ODU port, the port is immediately shut down
and the port status is displayed as TRIPPED.
After 15 seconds the Controller attempts to re-enable the port. If the fault condition is
resolved then the port is enabled automatically and port status changes from TRIPPED
to ON.
If another fault condition is detected within two minutes of the previous trip event, or if the
previous fault is still present, the port is again shut down and the status reverts to
TRIPPED. As before, the Controller will attempt to re-enable the port after 15 seconds.
If more than three faults are detected consecutively at intervals of less than two minutes,
the port will shut down and the status will change to TRIPPED as above, but the
Controller will wait for a full two minutes before attempting to reset the port again.
After the two minute waiting period is up, the port is reset and all internal counters and
timers are cleared. The process above is then repeated for any further error conditions
which may occur.
Note: The above description applies to version 00.21 Injector firmware. Versions 00.14 and
earlier differ in that the ODU ports are not automatically reset by the Controller. Instead the
operator must manually reset tripped ports by clicking the port status button for the affected
port after resolving the physical error condition.