Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Project: T7

China Harbour Engineering Company Nigeria Ltd Ref No.: N/A


Rev No.: N/A
NOISE MONITORING FORM Page: 1 of 3

Name of Project: JETTY-3 Construction Site Number: AREA F


Date: 12/01/2024

DISTANC
E FROM
S/N LOCATION TIME MEASURED SOURCE THE REMARKS
VALUE SOURCE
(M)
DURING THE PILING OPERATION

OFFSHORE MAIN PILE 178 Z-7 BARGE


PILING /
1 PILING AREA 4:22PM 100.4dB GENERATOR 5M PILING OPERATION
PILING/
2 CRANE AREA 4:26PM 105.9dB CRANE SOUND 15M PILING OPERATION

3 SEASHORE 4:28PM 95.5dB PILING 22M PILING OPERATION


AREA

4 SHIP MIDLE 4:28PM 89.7dB PILING/ 30M PILING OPERATION


ACTIVITY
PILING
5 WASTE 4:29PM 87.6dB PILING/ 54M OPERATION
STORAGE ACTIVITY
AREA

6 RESTING AREA 4:30PM 85.0dB PILING 56M PILLING ACTIVITY


ACTIVITY

7 MUSTER 4:30PM 88.8dB PILING/ 60 M PILLING/GENER


POINT NOISE FROM ATOR SOUND
GENERATOR
AFTER THE PILING OPERATION

1 PILING AREA 4:50PM 79.9dB NO PILLING 5M CRANE SOUND

LIFTING
2 CRANE AREA 4:52PM 80.5dB NO 15M OPERATION/ CRANE
PILLING SOUND
/CRANE
SOUND

3 SHORESIDE 4:53PM 78.8dB NO PILLING 22M LIFTING


AREA OPERATION

30M WELDING WORKS


4 SHIP MIDDLE 4:53PM 77.4dB NO PILLIG ON PROGRESS
AREA
MAINTANACE AND
5 WASTE 4:54PM 79.0dB NO PILING 54M REPAIRING/MACHIN
STORAGE E SOUND
AREA

6 RESTING AREA 4:54PM 76.6dB NO PILING 56M BACKGROUND SOUND


Project: T7
China Harbour Engineering Company Nigeria Ltd Ref No.: N/A
Rev No.: N/A
NOISE MONITORING FORM Page: 2 of 3

7 MUSTER 4:55PM 79.3dB NO PILING 60M LIFTING OPERATION


POINT AREA

Tested by: AMADI PRINCE Verified by: SHEKHAR GOLLA

Signature Signature

Noise Levels in Places of Work and the Allowable Period for Exposition
1. The noise level in a workplace must not exceed 85 decibels for an exposure of 8 hours a day 5 days a week and a one
time exposure must not exceed 115 decibels.
2. Noise should be measured at different distances from the sources starting within 1 m of the sources & then increasing the
distance by 10 m intervals or so.
3. The distance at which the noise level falls below the TLV i.e, 85 dba should be demarcated & Signs / Barriers should be
placed to indicate that hearing protection is required beyond that point

Z-7 BARGE AND MARKED PLACE (NOISE TESTING AREA)

1. During the Noise Test


MMO AND NOISE MONITORING PHOTO

You might also like