Foundation Plan 1 Roof Beams Plan 3 Roof Fraiming Plan 5: FTB FTB FTB FTB RB-1 RB-1 RB-1 RB-1

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5

1 2 3 4 5 1 2 3 4 5
1.00 3.10 1.00 3.10 1.00 3.10 1.00 3.10 1.00

0.36 0.64 3.10 0.50 0.50 3.10 0.50 0.50 3.10 0.50 0.50 3.74 0.64 0.36
0.36

A A
RB-1 RB-1 RB-1 RB-1 A
1.00
0.64

FTB FTB FTB FTB 2"X3" C-PURLINS


C1-F1 C1-F1 C1-F1 C1-F1 C1-F1 SPACED @800MM

2.79
RB-1
RB-1

RB-1
RB-1
2.79

RB-1
1.75

1.75

FTB
FTB
FTB

FTB

FTB

TRUSSES

TRUSSES

TRUSSES

TRUSSES

TRUSSES
0.50 0.50

B B B
C1-F1

C1-F1

C1-F1

C1-F1

C1-F1
1.00

2.75
FTB

FTB

RB-1

RB-1

RB-1
1.75

1.75

2.75
FTB

FTB

FTB

RB-1

RB-1
FTB FTB RB-1 RB-1 RB-1 RB-1
C
0.64

FTB FTB
1.00

C C
0.36

C1-F1 C1-F1 C1-F1 C1-F1 C1-F1 0.10 4.14 4.10 4.10 4.14 0.10 4.14 4.10 4.10 4.14
0.10 0.10

125MM THK CONCRETE SLAB-ON-FILL (SOG)W/ 10MM DIAMETER RSB


SPACED @ 400MM O.C. ON 50MM THK WELL-COMPACTED GRAVEL
BEDDING ON WELL-COMPACTED SUB-GRADE (WITH A MINIMUM OF
95% OF THE MAXIMUM OPTIMUM MOISTURE CONTENT).

FOUNDATION PLAN ROOF BEAMS PLAN ROOF FRAIMING PLAN


1 1 : 100
3 1 : 100 5 1 : 100

6-12MM VERT. BARS W/


TOP BAR TOP BAR
10MM LAT. TIES SP @
CONTINOUS BARS @ RIGHT SUPPORT
3-50MM, 3-100MM AND L @ LEFT SUPPORT 2 - 2" x 2" x 1/4" THK ANGLE BAR 1- 2" x 2" x 1/4" THK ANGLE BAR
REST @ 200 O.C BW
TOP & BOTTOM CHORD VERTICAL & DIAGONAL BRACE

6-12MM

0.76
VERT. BARS
W/ 10MM
L/4 L/4

0.25
16MM STEEL BARS LAT. TIES SP
MATTING B.W. @ 3-50MM, BOTTOM BAR
3-100MM
@ MIDSPAN
W

AND REST @
200 O.C BW
0.49 0.57 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70

BOTTOM BAR BOTTOM BAR


@ LEFT SUPPORT L @ RIGHT SUPPORT
6.66

PLAN
SECTION
CLEAR SPAN
STEEL TRUSS DETAIL
COLUMN & FTG DETAIL TYPICAL BEAM DETAILS 6 1 : 40
2 1 : 25
4 1 : 30

SCHEDULE OF REINFORCED FOOTING


DIMENSION (MM) SCHEDULE OF REINFORCED CONCRETE BEAM 4'' THK CHB W/
10MM VERT. AND
0.10
0.15
MARK H - DEPTH REINFORCEMENT BARS HOR. BARS SP. @
6O AND EVERY
LENGTH WIDTH THICKNESS THIRD LAYER
MARK @ RIGHT SUPPORT @ RIGHT SUPPORT @ RIGHT SUPPORT STIRRUPS REMARKS

0.20 0.20 0.20 1OMM RSB

0.41
F1 1000 1000 300 1200 6 PCS - 12MM REBAR USE 10MM DIA. 25MM THK
TOP BARS TOP BARS TOP BARS LATERAL TIES SPCED @ PLASTERING
2 PCS - 12MM DIA. 4 PCS - 12MM DIA.
RB-1 4 PCS - 12MM DIA. REBAR 1- 50MM, 2 - 100MM, ROOF BEAM
0.30
0.30

REBAR
0.30

REBAR
BOTTOM BARS BOTTOM BARS 3 - 150MM, AND REST

0.30
BOTTOM BARS 2 PCS - 12MM DIA.
4 PCS - 12MM DIA.
2 PCS - 12MM DIA. REBAR
REBAR REBAR 200MM OC
@150MM THK CHB WALL
SCHEDULE OF REINFORCED COLUMN 0.20 0.20 0.20
USE 10MM DIA.
0.30 WF-1
TOP BARS TOP BARS TOP BARS
CROSS SECTION 2 PCS - 12MM DIA. REBAR 4 PCS - 12MM DIA. 2 PCS - 12MM DIA. REBARLATERAL TIES SPCED @ TIE BEAM
NO. OF SETS
0.30

FTB
0.30

0.30

LATERAL TIES REBAR 1- 50MM, 2 - 100MM,


MARK REINFORCEMENT BARS BOTTOM BARS BOTTOM BARS BOTTOM BARS
LENGTH WIDTH 4 PCS - 12MM DIA. 2 PCS - 12MM DIA. 4 PCS - 12MM DIA. REBAR3 - 150MM, AND REST
REBAR REBAR 200MM OC
TYP. WALL FTG. DETAILS
6 PCS - 12 MM
USE 10MM DIA. LATERAL TIES
SPCED @ 1- 50MM, 2 - 100MM, 3 -
7 1 : 25
C1 280 280 @VERTICAL BARS 15
SETS 150MM, AND REST 200MM OC

ARCHITECT: CIVIL ENGINEER: RA 9266 ART.5 SEC.33 OWNER: PROJECT TITLE: NO. REVISION: CKD BY: DATE SHEET NO.:
OWNER OF PLANS SPECIFICATIONS AND
PROPOSED 4 UNIT RESIDENTIAL
JASPER RYAN S. GONZALES
OTHER CONTRACT DOCUMENTS
Drawing and specifications and other documents duly signed,
MRS. MA. JULIETA C. FLOJO APARTMENT S-1
stamped, or sealed, as an instruments of services are the intelectual
property of the architect whether the object which they are made is
PRC NO: PTR: PRC NO: PTR: executed or not it shall be unlawfull for any person to duplicate or DESIGNED BY: CADD BY: LOCATION :
4 6
make copy of sealed documents for use in the repetition od and for
PLACE : DATE: PLACE : DATE: other projects or buildings, whether executed partly or whole, BERNABE III - BRGY. BINARITAN
without the written consent of architect or author of said documents.
TIN NO. : TIN NO. : MORONG, BATAAN

You might also like