LenelS2

1212 Pittsford-Victor Road


Pittsford, New York 14534 USA
Tel 866.788.5095 Fax 585.248.9185
www.LenelS2.com

OpenAccess Alliance Program

Factory Certified Product (FCP) Interface Document


(This document does not include all sales related information. Please contact the OAAP
Member’s Sales, VAR, or LenelS2 Sales for additional details.)

OAAP Member Information

IDEMIA
Member Company Name and
2 Place Samuel de Champlain
Address
92400 Courbevoie, France

FCP Contact for LenelS2 Value Added Resellers and


Sales Team
Member Contact Name: Matthew INSLEY
Phone: +44 (0)7972 930 824
Email: matthew.insley@idemia.com
Technical Support Contact ASIA, PACIFIC
• Email: support.bioterminals.in@idemia.com
Technical Support Phone • Phone: +91 8929159665
Technical Support Email
EUROPE, MIDDLE EAST, AFRICA
• Email: support.bioterminals@idemia.com
• Phone: +33 1 30 20 30 40

INDIA
• Email: support.bioterminals.in@idemia.com
• Phone: +91 1800 120 203 020

NORTH AMERICA
• Email: support.bioterminals.us@idemia.com
• Phone: +1 888 940 7477

SOUTH AMERICA
• Email: support.bioterminals.us@idemia.com
• Phone: +1 714 575 2973
Technical Support Hours 24/7

OnGuard Information
OnGuard Version/Build, Firmware OnGuard 8.2 (8.2.524.0)
OnGuard 8.1 (8.1.639.195)
OnGuard API Used for Integration OpenAccess
Accessory Add-On File Name (for N/A
Interfaces Using OpenDevice)
Translator Filename N/A
Translator md5 checksum N/A
Additional OnGuard Files Required N/A

Revision 12.006 (March 2022) 1


OnGuard License Entries Required IPC-094-MRPHO01-B
for the Integration
Maximum Number of Local Readers
Maximum Number of Readers for System Type
Maximum Number of Readers in Enterprise (for Enterprise
systems)

Open Capture Fingerprint (SWG-1407) (Optional – to enroll


biometric templates in OnGuard)

OAAP Product Information


Name: MorphoManager Software
Supporting the following Hardware
Devices :
• VisionPass
• MorphoWave Compact (XP)
• MorphoWave SP
• SIGMA Lite Series
• SIGMA Lite+ Series
• SIGMA Wide Series
• SIGMA Extreme Series
• MSO 330 (enroller)
• MSO1300 (enroller)

Model: VisionPass MD
VisionPass MDPI
VisionPass MDPI-M

MorphoWave Compact MD
Product Being Integrated MorphoWave Compact MDPI
MorphoWave Compact MDPI-M

MorphoWave SP MD
MorphoWave SP MDPI
MorphoWave SP MDPI-M

SIGMA Lite
SIGMA Lite iClass
SIGMA Lite Multi
SIGMA Lite Prox

SIGMA Lite+ iClass


SIGMA Lite+ Multi
SIGMA Lite+ Prox

SIGMA Wide iClass


SIGMA Wide Multi

Revision 12.008 (May 2022) 2


SIGMA Extreme iClass
SIGMA Extreme Multi
SIGMA Extreme Prox

Version/Firmware: MorphoManager version 16.3

All terminals from SIGMA Family


with firmware revision 4.12

MorphoWave Compact and


VisionPass with firmware revision
2.10
List all SDK or other files/applications that you must
Files Required (for Communication install/run for this integration to function with OnGuard.
with OnGuard System):
N/A
Ports Required to be Open for
8080 (OpenAccess port)
Communication with OnGuard
Member License Entries Required N/A
for the Integration
(NA if no Member licenses required)
Web Location for Download of www.morphomanager.com
Proprietary Files

Brief Description of Product Combined with IDEMIA biometric terminals,


MorphoManager provides a seamless, comprehensive
solution for Access Control and Time & Attendance
applications. It offers easy configuration, group-based
settings, centralized management and detailed
reporting.
Business Description of Product Single data source of users between OnGuard and
IDEMIA biometric terminals.

Supported Operating System and Database Information


Operating ☐Windows 7 Enterprise, Pro, Ultimate (64-bit)
System ☐Windows 8.1 Enterprise, Professional (64-bit)
OAAP Product System ☒Windows 10 and IoT Enterprise, Pro (64-bit)
(Supported Operating Systems and ☒Windows 11 and IoT Enterprise, Pro (64-bit)
Databases of OAAP product. Note that all ☒Windows Server 2012 R2 (64-bit)
Operating systems and Databases listed ☒Windows Server 2016 (64-bit)
are not compatible with all versions of ☒Windows Server 2019 (64-bit)
OnGuard. Refer to Compatibility Charts ☒Windows Server 2022 (64-bit)
provided with each version of OnGuard.) ☐Other (Specify):
Database ☐SQL Server 2012 R1 (64-bit)
☐SQL Server 2014 (64 bit)

Revision 12.008 (May 2022) 3


☐SQL Server 2016 (64-bit)
☒SQL Server 2017 (64-bit)
☒SQL Server 2019 (64-bit)
☐Other (Specify):

Functional Features of the Interface


MorphoManager connected to OnGuard will synchronize all
OnGuard Cardholders with active Badges according to
criteria configured in MorphoManager and the BioBridge
OnGuard Connection Configuration. OnGuard Cardholders
that are synchronized may be limited by Badge Type and
Access Level.

OnGuard Cardholders that have existing fingerprint biometric


templates captured may have those templates synchronized
to MorphoManager during synchronization. (INCITS 378 or
PK_COMP templates only). Cardholders can also be enrolled
using IDEMIA terminals.
Customers should expect the
interface to allow them to: IDEMIA terminals can be wired to OnGuard Reader
Interfaces (Wiegand or OSDP) and are configured as readers
in OnGuard.

Updates to OnGuard Cardholders (name changes), Badge


status changes, and Access Level assignments are received
and applied by MorphoManager automatically.

Events can be sent to OnGuard Alarm Monitoring to indicate


failed biometric verification at the IDEMIA terminals. (This is
an optional configuration.)

Limitations for this product integration can be found here

Revision 12.008 (May 2022) 4


Segmentation
If Segmentation is not fully implemented, document what is not supported in the Limitations section of this document.

☐ Segment options have no effect on the interface’s functionality.

☒ Works on all Segmented Systems – Segmentation is not fully implemented.


See Limitations Section for details.

☐ Segmentation is fully supported

Revision 12.008 (May 2022) 5


OpenAccess
List all calls, instances, and methods used by the integration

authentication (Add, Delete)


get_session
get_cardholders (includes Badge, Lnl_AccessLevelAssignment)
get_version
keepalive
business_event_subscription (Add, Modify, Delete)

Lnl_BadgeType
Lnl_AccessLevel
If this is an OpenAccess get instances
Lnl_MultimediaObject
integration, list all the Lnl_AccessLevelAssignment
API calls used by the
integration. add instances

modify instances

delete instances

execute_method Lnl_IncomingEvent SendIncomingEvent

segmentation data
classes/methods
supported

Are OnGuard ☒ YES ☐ NO


Cardholder/Badge fields Cardholder – Last Name
required by the
Badge Status = Active
integration?

If yes, list the required


fields.

Does the integration ☐ YES ☒ NO


require the creation of
Custom Fields on the
Cardholder Form?

Setup and User Documents


BioBridge Quick Start Guide - OnGuard (OpenAccess)

MorphoManager User Manual

Revision 12.008 (May 2022) 6


System/Integration Topology

Limitations/Notes
ID Severity Summary
DE145181 Must Fix The MorphoManager integration with OnGuard will attempt to
Before Next authenticate three times per second if authentication fails due to a
Certification missing/expired license or invalid username/password. When the
failure to authenticate requires user intervention to correct an
integration must not attempt authentication with high frequency
nor continue indefinitely.

DE145138 Acceptable When configuring the integration to communicate with the OnGuard
Limitation API (OpenAccess) the OnGuard Directory ID must be entered in
the BioBridge System Configuration screen rather than selecting
the desired directory from a drop down list. Using a web browser,
the directory names and ID's can be retrieved by entering this URL:
https://<FQDN_of_Server>/api/access/onguard/openaccess/directo
ries?version=1.0.

DE145143 Acceptable There is no indication in OnGuard when the MorphoManager server


Limitation is not communicating with OnGuard due to network disconnect
or service/server restart.

Revision 12.008 (May 2022) 7


DE145144 Acceptable Removing and restoring the Idemia readers to the network, results
Limitation in no alarm or status change shown in OnGuard Alarm Monitoring.

DE145149 Acceptable OnGuard Badge PIN is not synchronized by the MorphoManager


Limitation integration.

DE145150 Acceptable MorphManager does not support a Cardholder having multiple


Limitation active badges. In cases where a Cardholder does have multiple
active badges, MorphoManager will synchronize the first badge
issued.

DE145189 Acceptable The OnGuard Access Levels containing the Morpho readers must
Limitation be linked to a Distribution Group in MorphoManager. The
Distribution Group should contain the same devices that are in
the OnGuard Access Level, but this is not required. The mapping of
Access Level to Distribution Group in MorphoManager is a manual
process.

DE145198 Acceptable When an Idemia Terminal (Reader) that is wired as a Wiegand


Limitation reader is removed from the OnGuard Access Level but not
removed from the MorphoManager Distribution Group, the terminal
will still verify a Cardholder's biometric template and display Access
Granted, however the panel will deny access with an Invalid Access
Level. Terminals that are wired using OSDP will receive feedback
from the panel and display Denied Access.

DE145191 Acceptable When a single OnGuard Badge Type is configured in the


Limitation MorphoManager BioBridge settings, only Cardholders that have
active Badges of that Badge Type will be synchronized to
MorphoManager.

DE145192 Acceptable The MorphoManager integration does not automatically create a


Limitation Logical Source or Logical Device for each Idemia terminal. The
Logical Source and Logical Devices must be manually created in
OnGuard System Administration.

DE145188 Note Synchronization of existing biometric templates from OnGuard was


not tested.

DE145232 Acceptable The MorphoManager integration does not explicitly support


Limitation OnGuard segmentation but will work with a segmented OnGuard
system. It is recommended that the OnGuard User Account used
by MorphoManager be an All Segments User .