Professional Documents
Culture Documents
Interface Idemia MorphoManager OG81-82 OCT2023
Interface Idemia MorphoManager OG81-82 OCT2023
IDEMIA
Member Company Name and
2 Place Samuel de Champlain
Address
92400 Courbevoie, France
INDIA
• Email: support.bioterminals.in@idemia.com
• Phone: +91 1800 120 203 020
NORTH AMERICA
• Email: support.bioterminals.us@idemia.com
• Phone: +1 888 940 7477
SOUTH AMERICA
• Email: support.bioterminals.us@idemia.com
• Phone: +1 714 575 2973
Technical Support Hours 24/7
OnGuard Information
OnGuard Version/Build, Firmware OnGuard 8.2 (8.2.524.0)
OnGuard 8.1 (8.1.639.195)
OnGuard API Used for Integration OpenAccess
Accessory Add-On File Name (for N/A
Interfaces Using OpenDevice)
Translator Filename N/A
Translator md5 checksum N/A
Additional OnGuard Files Required N/A
Model: VisionPass MD
VisionPass MDPI
VisionPass MDPI-M
MorphoWave Compact MD
Product Being Integrated MorphoWave Compact MDPI
MorphoWave Compact MDPI-M
MorphoWave SP MD
MorphoWave SP MDPI
MorphoWave SP MDPI-M
SIGMA Lite
SIGMA Lite iClass
SIGMA Lite Multi
SIGMA Lite Prox
Lnl_BadgeType
Lnl_AccessLevel
If this is an OpenAccess get instances
Lnl_MultimediaObject
integration, list all the Lnl_AccessLevelAssignment
API calls used by the
integration. add instances
modify instances
delete instances
segmentation data
classes/methods
supported
Limitations/Notes
ID Severity Summary
DE145181 Must Fix The MorphoManager integration with OnGuard will attempt to
Before Next authenticate three times per second if authentication fails due to a
Certification missing/expired license or invalid username/password. When the
failure to authenticate requires user intervention to correct an
integration must not attempt authentication with high frequency
nor continue indefinitely.
DE145138 Acceptable When configuring the integration to communicate with the OnGuard
Limitation API (OpenAccess) the OnGuard Directory ID must be entered in
the BioBridge System Configuration screen rather than selecting
the desired directory from a drop down list. Using a web browser,
the directory names and ID's can be retrieved by entering this URL:
https://<FQDN_of_Server>/api/access/onguard/openaccess/directo
ries?version=1.0.
DE145189 Acceptable The OnGuard Access Levels containing the Morpho readers must
Limitation be linked to a Distribution Group in MorphoManager. The
Distribution Group should contain the same devices that are in
the OnGuard Access Level, but this is not required. The mapping of
Access Level to Distribution Group in MorphoManager is a manual
process.