Switching and protection of main and auxiliary electric circuits for locomotives, trains and EMUs running on 15 kVAC or/and 25 kVAC
networks.
Main features
• Compact multi-functional switch including: AC circuit-breaker, earthing switch (option) and surge arrester (option) on a single support
of 940 mm x 430 mm.
AC circuit-breaker
• Suitable for 15 kVAC and/or 25 kVAC networks
• Conventional free air thermal current: 1000 A
• Rated impulse withstand voltage (1.2 / 50 µs): Uimp = 125 kV or 170 kV
• Indoor or outdoor installation
• Vertical or horizontal mounting
• External creepage distances > 1000 mm
• Vacuum interrupter
• Electric operation (closing and holding)
• High safety thanks to the automatic opening through spring release in case of interruption of
supply voltage (no need of stored auxiliary electrical energy)
• High mechanical durability: > 250’000 operations
• Low height: 563 mm (for Uimp = 125 kV) above the roof and 140 mm below the roof
• Low weight: < 100 kg for the AC circuit-breaker
• Usable in various ranges of ambient temperature from -40 °C to +70 °C (-50 °C to +70 °C in option)
• Reference standards: IEC60077-1 /-2 /-4, IEC61373, EN50121-3-2, NF F16-101 /-102
2
Data for product selection
Symbol Unit 15 kV 25 kV
MAIN HIGH VOLTAGE CIRCUIT
AC circuit-breaker
Rated operational voltage Ue [VAC] 17’250 (1) 27’500 (1)
Rated insulation voltage Ui [VAC] 27’500 (1) 27’500 (1)
Rated operational current Ie [A] 1’000 1’000
Conventional free air thermal current (2) Ith [A] 1’000 1’000
Rated operational frequency f [Hz] 16.7 50, 60
Operational category C3 C3
Peak short-circuit making current IMC [kA] 63 50
Rated short-circuit breaking current / % value of the DC component [kA]/% 25/50 20/50
Peak and rated short-time withstand current (1 s) Îcw/Icw [kA]/[kA] 63/25 63/25
Short-time withstand currents 100 ms Icw 40 40
Rated power-frequency withstand voltage (50 Hz, 1 mn) U50 [kVrms] 75 75
Rated impulse withstand voltage (1.2/50 µs) Uimp [kV] 125 125/170
(1) For higher values, please contact Sécheron.
(2) At Tamb = +40 °C and tested with high voltage connections according to standard IEC/EN 60943.
Earthing switch
Peak and rated short-time withstand current Îcw/Icw/t [kA]/[kA]/[s] 63/25/1 63/25/1
LOW VOLTAGE AUXILIARY CIRCUIT
Control circuit
AC circuit-breaker
Nominal voltage (power supply and control order) Un [VDC] 24 to 110
Range of voltage (power supply and control order) [0.7 - 1.25] Un
Maximum power (loading and holding) (3) (4) Pmax [W] 100
Nominal holding power (4) Ph [W] 35
Opening power [W] 0
Mechanical opening time (4) To [ms] 50
Mechanical closing time (4) Tc [ms] 65
Earthing switch (optional electric operation)
Nominal voltage Un [VDC] 24, 32, 36, 48/50, 72, 110
Operating power (4) [W] 125
Commutation time (4) [s] 3
(3) Loading time < 12 seconds.
(4) At Un and Tamb = + 20 °C.
Auxiliary contacts
Type of contacts (5) Potential free
Rated voltage [VDC] 24 to 110
Conventional thermal current Ith [A] 10
Switching categories according to EN60947 (silver contacts) - AC-15 230 VAC 1.0 A
- DC-13 110 VDC 0.5 A
Minimum let-through current at 24 VDC (6) [mA] 10 (silver contacts) or
4 I < 10 (gold contacts)
(5) Refer to page 6.
(6) For a dry and clean environment.
Low voltage interface
Type of connection (7)
- AC VCB with or without manual earthing switch 1 Connector: Harting 51 P
- AC VCB with electric earthing switch 2 Connectors: Harting 51 P + Harting 24 DD
(7)
Refer to page 7 for mobile connector information.
Insulation
Rated power-frequency withstand voltage (50 Hz, 1 mn) U50 [kVrms] 1.5
OPERATING CONDITIONS
Installation Indoor or outdoor
Altitude [m] < 1400
Working ambient temperature Tamb [°C] -40 to +70 / -50 to +70
Humidity Class 5K2
Pollution degree PD4
Minimum mechanical durability N [Cycles] 250’000
3
Main dimensions
Dimensions without tolerances are indicative. All dimensions are in mm. Weight:
The maximum allowed flatness deviation of the support frame is 0.5 mm. Refer to the table below
HV and earth connections: M12 screws.
AC circuit-breaker 15 kVAC and 25 kVAC
Uimp [kV]
HV 125 170
241
15 kV 25kV 25 kV
HV A (mm) 563 563 578
A
15
Frame level
140
320
420 420
64 32 880
101
114
420 420
>430
430
385
330
388
385
Roof opening and frame dimensions
150
105
65 110
22.5
Weight:
Electric version (option) Manual version (standard) AC circuit-breaker + 13 kg (manual version)
AC circuit-breaker + 21 kg (electric version)
HV
HV
530
139
142
320
220*
50* 151
253
852 150* 380*
4
AC circuit-breaker 25 kVAC (Uimp=170 kV) and earthing switch
Weight:
AC circuit-breaker + 14 kg (manual version)
AC circuit-breaker + 22 kg (electric version)
Electric version (option) Manual version (standard)
HV
HV
540
140
165
142 320
220*
50* 844 150*
380*
122 47
* Space needed to remove the cover and to operate the optional earthing switch.
430
5
AC circuit-breaker and surge arrester selection
Overhead line 15 or 25 kVAC For a safe and efficient protection of the vehicle’s high voltage
AC circuits against ligthning and switching overvoltages, Sécheron
VCB recommends to use two surge arresters SA1 and SA2 in the
high voltage circuit of the vehicle. In order to protect efficiently
SA2 ES SA1 the AC circuit-breaker, the distance between each surge
arrester and the AC circuit-breaker must not exceed 15 meters.
MACS standard configuration (4a+4b – switch PF), with optional additional auxiliary switches (4a+4b – switch PF) and optional manual
earthing switch (2a+2b – switch PF).
c9 Ra
Rb c4 c5 c6 c15
c14
ES
I J
B : Battery power supply
O : Control order
R : Ready switch (MACS ready to close)
ES : Earthing switch c16 c10 c11 c17
: Optional auxiliary contacts
a b c
6
Designation code for ordering
LV mobile connector for AC circuit-breaker (separately ordered item)
SG325249R00521
Case 7
Harting Harting
ES 2a + 2b PF 2 12 M25
HAN® 24 DD HAN® 24 DD
SG325249R00520
Harting Han® Modular 51 pins connector is made of 3 Harting HAN® DDD17 modules (each module supplied with 17 pins).
The above references are given for mobile connectors considering that all the auxiliary contacts are wired, with an external wire diameter
of 2.8 mm for a copper section of 2.5mm² and 2.3 mm for a copper section of 1.5 mm². If the conditions are different from these, the
above references may change. In such case please inform Sécheron accordingly.
7
Designation code information
• Be sure to establish the designation code from our latest version of the brochure by downloading it from our website
“www.secheron.com”.
• Be careful to write down the complete alphanumerical designation code with 11 characters when placing your order.
• For technical reasons some variants and options indicated in the designation code might not be combined.
Example of customer’s choice: M 2 A 1 A E A B Z Z 1
Line: 10 11 12 13 14 15 16 17 18 19 20
Designation code (options are subject to additional costs) - Order form
- Additional LV mobile connector for the electric earthing switch: SG325249R00521 SG325249R00520