JKR E-Tender | SD210723

BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E1 - SITE PREPARATION, EARTHWORKS &


OTHER TEMPORARY WORKS (ALL PROVISIONAL)

NOTES TO TENDERER :-

The Contractor shall inspect the site before


submitting his tender to acquaint and ascertain for
himself the nature and extent of the Works and site
conditions which may affect the contract work as no
extra payment consequent upon lack of knowledge
will be considered.

The Contractor shall make preliminary and final survey of


the works and provide survey results and as-built plans
to the Engineer/S.O., the requirement of which had been
outlined in the Preliminaries section of this document.

It is tenderer's responsibility to satisfy himself that the


information given herein for the Site Clearance and
Earthworks are adequate and correct. The tenderer is
deemed to have visited the site to ascertain the extent of
the Site Clearance and Earthworks involved and obtain
other further information as no claims will be entertained
on ground of inadequate or incorrect information given
herein.

The Contractor's attention is drawn to the fact that they


are required to fully comply with latest relevant
Environmental Act. In which "open burning' is not
permitted within the site and proximity of the region.
Therefore, the rates inserted herein shall include for
transportation of surplus materials away from the Site.

Where excavation is to be carried out on area of


unsuitable materials, due preparation shall be maintained
and provided so as to avoid sunken or damage to the
Contractor's machineries and all costs thereto shall be
accordingly allowed and Client in any way shall not be
responsible of such losses incurred by the Contractor
arising of lack of knowledge on the soil and site
conditions.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723
MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection -

E/ 1/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E1 - SITE PREPARATION, EARTHWORKS &


OTHER TEMPORARY WORKS (ALL PROVISIONAL)
(CONT'd)

NOTES TO TENDERER :- (CONT'd)

The Contractor shall inspect the site before


submitting his tender to acquaint and ascertain for
himself the nature and extent of the Works and site
conditions which may affect the contract work as no
extra payment consequent upon lack of knowledge
will be considered. (CONT'd)

The filling quantities are measured based on


consolidated and compacted volume and as such, the
quantities of earth and granular materials brought to the
Site shall not reflect the actual quantities of the Bills of
Quantities. The Contractor shall therefore to allow for all
factors of consolidation and compaction shrinkage
whatsoever the filling materials and pricing shall include
all factors thereof.

SITE CLEARANCE

A Clear the site where directed by the S.O within the Ha 2.20 5,000.00 11,000.00
boundaries of trees irrespective of tree girth, vegetations,
crops, loose vegetation matter and rubbish including
grubbing up stumps and tree roots and removing off site

EARTHWORKS

B Imported Earthfilling with suitable and approved material m3 46,574 31.00 1,443,794.00
as specified in making up level including spread, grade
and compact to construct platforms, slopes,
embankments and bunds etc. to the required levels and
gradients (measured nett overall)

C Excavate/cut in bulk all unsuitable materials (except rock) m3 21,791 8.00 174,328.00
to formation levels for building platforms, road and slope
formations including load and cart away from site to
contractor's own dumping area (measured nett overall).

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 1,629,122.00

E/ 1/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E1 - SITE PREPARATION, EARTHWORKS &


OTHER TEMPORARY WORKS (ALL PROVISIONAL)
(CONT'd)

EARTHWORKS (CONT'd)

A Imported sand filling with suitable and approved material m3 21,791 40.00 871,640.00
as specified in making up level including spread, grade
and compact to construct platforms, slopes,
embankments and bunds etc. to the required levels and
gradients (measured nett overall)

SURCHAGE

B Placed and compact suitable imported earthfill as m3 10,896 10.00 108,960.00


surcharge to embankment and removed surplus
surcharge material from site after 10.8 month all to
Engineer's approval.

Testing

C Provide equipment, manpower and all necessary item to nos 5 250.00 1,250.00
run the Field Density Test (FDT) to determine number of
rolling passes in relation to the loose depth to archive
desired compaction and approved by the S.O.

D Provide equipment, manpower and all necessary item to nos 5 500.00 2,500.00
run the in-situ CBR test in the location to be determine by
the S.O.

Settlement Plate and marker

E Allow for settlement plate to engineer's approval and no 10 300.00 3,000.00


specification as per drawing

F Allow for settlement marker to engineer's approval and no 20 300.00 6,000.00


specification as per drawing

TURFING

G Closed turfing as specified to specified to surface of soil m2 3,520 8.50 29,920.00


with approved quality cow grass including one layer of
50mm thick vegetable soil complete with all necessary
watering, rolling, weeding and tending until firmly
established

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 1,023,270.00

E/ 1/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E1 - SITE PREPARATION, EARTHWORKS &


OTHER TEMPORARY WORKS (ALL PROVISIONAL)
(CONT'd)

OTHER TEMPORARY WORKS

Temporary Earth Drain

A Temporary earth drain, 600mm wide (bottom) with m 484 40.00 19,360.00
1200mm wide (top) X 300mm deep earth drain complete
with and including excavation, transporting excavated
materials, forming and ramming slopes and base of earth
drain, diversion channel, discharge to sediment basin,
periodical desilting, repairing and maintenance to the
satisfaction of the S.O. remove temporary works and
make good to platform levels upon completion of the
works as per Engineer's drawing no.
PWW/21227/INF/EW/LAY/01,
PWW/21227/INF/EW/DET/05.

Check Dam

B Temporary check dam, 1200mm long x 600mm wide no 7 111.00 777.00


(bottom) with 1500mm wide (top) X 450mm deep earth
drain complete with check dam 50mm size aggregate for
filtration including excavation works, transporting
excavated materials, periodical desilting, repairing and
maintenance to the satisfaction of the S.O. remove
temporary works and make good to platform levels upon
completion of the works as per Engineer's drawing no.
PWW/21227/INF/EW/LAY/01,
PWW/21227/INF/EW/DET/05.

Culvert

C Temporary culvert overall size 600mm diameter no 37 450.00 16,650.00


complete with excavation works, reinforced concrete
base, reinforcement, formwork with and including
periodical desilting, repairing and remove temporary
works and make good to platform levels upon completion
of the works as per Engineer's drawing.
PWW/21227/INF/EW/LAY/01.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 36,787.00

E/ 1/4
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E1 - SITE PREPARATION, EARTHWORKS &


OTHER TEMPORARY WORKS (ALL PROVISIONAL)
(CONT'd)

Silt Trap

A Temporary silt trap overall size 30.0m x 30.0m complete no 1 20,000.00 20,000.00
with excavation works, ramming slope and base, 230mm
thick rubber pitching, 900mm diameter pipe culvert,
primary outlet, secondary outlet, periodical desilting,
repairing and remove temporary works and make good
to platform levels upon completion of the works as per
Engineer's drawing. PWW/21227/INF/EW/LAY/01,
PWW/21227/INF/EW/DET/04.

Silt Fence

B Temporary silt fence 1500mm high constructed of 1.50m m 636 20.00 12,720.00
start pickets at 3.0m centres, self supporting geotextile
complete with 150mmx 100mm trench with compacted
backfill on rock set into surface concrete with and
including all necessary work as per Engineer's drawing
no. PWW/21227/INF/EW/LAY/01,
PWW/21227/INF/EW/DET/05.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 32,720.00

E/ 1/5
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E1 - SITE PREPARATION, EARTHWORKS &


OTHER TEMPORARY WORKS (ALL PROVISIONAL)
(CONT'd)

Wash Through

A Temporary wash trough overall size 10500mm x no 1 15,000.00 15,000.00


6000mm wide comprising of wash through sizes
6000mm x 5100mm wide and platform sizes 4500mm x
6000mm constructed with 100mm thick reinforced
concrete slab, 100mm thick hardcore, 40mm thick
screed, 1 layer wire mesh A6, 100mm thick rubber
pitching, 230mm half round drain, heavy duty mild steel
grating, 25mm diameter high tensile steel bars at 75mm
centres embedded 13mm into concrete slab and welded
to wire mesh, 150mm diameter PVC outlet pipe, 200mm
thick reinforced concrete slab with 1 layer BRC A6,
100mm thick hardcore and 40mm thick screed for
platform and all necessary formwork, excavation, forming
and ramming slopes, maintenance during construction,
removal of temporary works and make good to platform
levels after completion all as per Engineer's drawing no.
WW/21227/INF/EW/LAY/01,
PWW/21227/INF/EW/DET/04.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 15,000.00

E/ 1/6
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E1 - SITE PREPARATION, EARTHWORKS &


OTHER TEMPORARY WORKS (ALL PROVISIONAL)
(CONT'd)

COLLECTION PAGE

PAGE E/1/1 -

PAGE E/1/2 1,629,122.00

PAGE E/1/3 1,023,270.00

PAGE E/1/4 36,787.00

PAGE E/1/5 32,720.00

PAGE E/1/6 15,000.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 2,736,899.00

E/1/7
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E2 - ROADWORKS, CARPARKS &


HARDSTANDING (ALL PROVISIONAL)

ROADWORKS AND CARPARKS

A Excavate oversite for road formation average depth m2 4,794 5.00 23,970.00
550mm deep, commencing from platform level, get out,
part return, fill in and ram and deposit and spread in
making up level where directed and remainder, load and
cart away from site.

B Grade to road formation level to gradient and cross falls m2 4,794 2.00 9,588.00
and roll with 8 tonne roller

C 100mm thick granular sub-base of hard clean sand m2 4,794 5.00 23,970.00
spread and levelled and well rolled and compacted to fall
and chamber with 8 tonne roller toreceive crusher run

D 250mm Thick (consolidated) crusher run base course m2 4,794 25.00 119,850.00
laid in two layers of 150mm thick per layer with all
interstices filled with graded granite including well
consolidating, watering and blinding surface and rolling
with 8 ton roller

E Approved bituminous prime coat as specified to road and m2 4,794 2.00 9,588.00
carparks spread at rate 8 yard super per gallon

F 60mm Thick asphaltic premix binder course (AC28) as m2 4,794 36.00 172,584.00
specified spread on finished surfaces to receive premix
surfacing (measured separately).

G Approved bituminous tack coat as specified to road and m2 4,794 2.00 9,588.00
carparks spread at rate 10 yard super per gallon

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

H 40mm Thick (consolidated) premix as specified wearing m2 4,794 25.00 119,850.00


course rolled with 8 tonne roller.

J Allow for testing as specified in conjunction with L.S 10,000.00 10,000.00


roadworks

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 498,988.00

E/ 2/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E2 - ROADWORKS, CARPARKS &


HARDSTANDING (ALL PROVISIONAL) (CONT'd)

Road Kerb

A Construct and complete 600mm long x 100mm wide m 1,110 40.00 44,400.00
(extreme size) x 250mm high (extreme size) road kerb
with complete with concrete work, formworks, finished
fair on exposed surfaces, bedded jointed and pointed in
cement mortar including all necessary excavation,
painting, opening with 100mm diameter UPVC scupper
drain at 3000mm centres to Engineer's approval and as
per drawing no. PWWW/21227/INF/RD/DET/03.

Road Marking

Prepare and apply 2mm thick of thermoplastic road


paint on premix road and/or pavement to form :-

B 150mm Wide edge line m 767 6.00 4,602.00

C 100mm Wide parking line m 984 4.00 3,936.00

D 300mm Wide stop line m 17 12.00 204.00

E 1375mm Wide (extreme) single directional arrow sign for no 6 150.00 900.00
straight traffic overall length 5000mm.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

F 3000mm Wide (extreme) straight and corner directional no 5 150.00 750.00


arrow sign overall length 5000mm

G 1870mm Wide (extreme) corner directional arrow sign no 7 80.00 560.00


overall length 2500mm

H "OKU" sign marking no 2 150.00 300.00

J "EV" sign marking no 4 150.00 600.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 56,252.00

E/ 2/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E2 - ROADWORKS, CARPARKS &


HARDSTANDING (ALL PROVISIONAL) (CONT'd)

Road Signage

Supply and install the following road signboard


made of reflectorised sticker high intensity in
accordance to jabatan kerja raya (JKR)'s standard
including all excavation, post, footing and painting
works for post complete with other associated
accessories (CONT'd)

A Parking "P" sign (G1.4) no 7 600.00 4,200.00

B No entry sign (RP 8a) no 1 600.00 600.00

TRAFFIC MANAGEMENT PLAN

Note:
Traffic Management Plan and the associated work shall
be in accordance with the latest version of Specification
for Road Works

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Traffic management plan shall be deemed to include


emergency response plan and the associated works.

Item temporary road furniture shall be deemed to include


the supply, installation, mainternance and removal upon
completion

The supply of temporary road furniture shall be deemed


to include base preparation, cost of materials, fabrication,
and fixing including posts, struts, bolts and nuts, base,
storage, and transportation.

Installation of temporary road furniture shall be deemed


to include cost for multiple shifting within the contractual
boundaries and its vicinities that is affected by the traffic
management plan.

Temporary road furniture shall be deemed to include cost


for the inspection, immediate repair and replacement of
any damaged, missing or stolen items throughout the
duration of the construction, and removal upon
completion.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 4,800.00

E/ 2/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E2 - ROADWORKS, CARPARKS &


HARDSTANDING (ALL PROVISIONAL) (CONT'd)

TRAFFIC MANAGEMENT PLAN (Cont'd)

A Preparation of traffic management plan. Rate to include Item 10,000.00


the cost of any survey required, literature, references,
consultation and the product of the documents. It shall
also include the cost for the engagement of qualified
traffic engineer required for carrying out the respective
study, traffic management report, road safety audit report
and the preparation the said plan including traffic
management team and temporary road furniture and
other associated works; all as per S.O approval.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 10,000.00

E/ 2/4
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E2 - ROADWORKS, CARPARKS &


HARDSTANDING (ALL PROVISIONAL) (CONT'd)

COLLECTION PAGE

PAGE E/2/1 498,988.00

PAGE E/2/2 56,252.00

PAGE E/2/3 4,800.00

PAGE E/2/4 10,000.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 570,040.00

E/2/5
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL)

THE FOLLOWING IN 600MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN TYPE
D1

Excavate trench for drainage commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

A 740mm width drain, maximum depth not exceeding m3 241 5.00 1,205.00
1.00m deep

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

B 300mm Thick under precast U-drain m2 332 30.00 9,960.00

Lean concrete Grade 15 as specified :

C Under drain, not exceeding 100mm thick m3 17 325.00 5,525.00

Brickwork in cement and sand brick in cement and


sand (1:6) mortar with an approved plasticiser as
specified and reinforced with and including brick
reinforcement at every fourth course.

D 225mm thick wall m2 42 90.00 3,780.00

Cement and sand (1:6) with an approved plasticier


plastering finished with straight- edge wood float as
specified

E 20mm Thick to internal surfaces of wall, sides and top of m2 139 18.00 2,502.00
wall.

__________________________ - - -
F 600mm wide x 300mm high precast concrete U-drain m 448 115.00 51,520.00
channel laid to fall embedded on crusher run (measure
separately)

(End of 600mm Wide (Internal) Precast Concrete U-Drain -


(Type D1))

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 74,492.00

E/ 3/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN 600MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN WITH
COVER SLAB TYPE D1a

Excavate trench for drainage commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

A 740mm width drain, maximum depth not exceeding m3 107 5.00 535.00
1.00m deep

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

B 300mm Thick under precast U-drain m2 125 30.00 3,750.00

Lean concrete Grade 15 as specified :

C Under drain, not exceeding 100mm thick m3 6 325.00 1,950.00

Brickwork in cement and sand brick in cement and


sand (1:6) mortar with an approved plasticiser as
specified and reinforced with and including brick
reinforcement at every fourth course.

D 225mm thick wall m2 50 90.00 4,500.00

Cement and sand (1:6) with an approved plasticier


plastering finished with straight- edge wood float as
specified

E 20mm Thick to internal surfaces of wall, sides and top of m2 112 18.00 2,016.00
wall.

Reinforced vibrated precast concrete Grade 30 as


described including all moulds, hoisting and setting
in cement mortar (1:3) :-

F 600mm long x 740mm wide x 125mm thick drain cover no 283 82.00 23,206.00
finished fair on exposed surfaces and reinforced with and
including reinforcement bar of 10mm diameter at 100mm
centre high tensile, 6mm diameter at 200mm centre mild
steel complete with concrete work, rendering, formworks
and all necessary works.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 35,957.00

E/ 3/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN 600MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN WITH
COVER SLAB TYPE D1a (CONT'd)

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

A 600mm wide x 300mm high precast concrete U-drain m 169 125.00 21,125.00
channel laid to fall embedded on crusher run (measure
separately)

(End of 600mm Wide (Internal) Precast Concrete U-Drain


With Cover Slab (Type D1a))

THE FOLLOWING IN 600MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN WITH
COVER SLAB TYPE D2

Excavate trench for drainage commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

B 740mm width drain, maximum depth not exceeding m3 88 5.00 440.00


1.00m deep

C 740mm width drain, maximum depth not exceeding m3 62 10.00 620.00


2.00m deep

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

D 300mm Thick under precast U-drain m2 157 30.00 4,710.00

Lean concrete Grade 15 as specified :

E Under drain, not exceeding 100mm thick m3 8 325.00 2,600.00

Brickwork in cement and sand brick in cement and


sand (1:6) mortar with an approved plasticiser as
specified and reinforced with and including brick
reinforcement at every fourth course.

F 225mm thick wall m2 15 90.00 1,350.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 30,845.00

E/ 3/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

THE FOLLOWING IN 600MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN WITH
COVER SLAB TYPE D2 (CONT'd)

Cement and sand (1:6) with an approved plasticier


plastering finished with straight- edge wood float as
specified

A 20mm Thick to internal surfaces of wall, sides and top of m2 48 18.00 864.00
wall.

Reinforced vibrated precast concrete Grade 30 as


described including all moulds, hoisting and setting
in cement mortar (1:3) :-

B 600mm long x 740mm wide x 125mm thick drain cover no 354 82.00 29,028.00
finished fair on exposed surfaces and reinforced with and
including reinforcement bar of 10mm diameter at 100mm
centre high tensile, 6mm diameter at 200mm centre mild
steel complete with concrete work, rendering, formworks
and all necessary works.

______________

C 600mm wide x 600mm high precast concrete U-drain m 212 170.00 36,040.00
channel laid to fall embedded on crusher run (measure
separately)

(End of 600mm Wide (Internal) Precast Concrete U-Drain


With Cover Slab (Type D2)

THE FOLLOWING IN 900MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN WITH
COVER SLAB TYPE D3

Excavate trench for drainage commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

D 1060mm width drain, maximum depth not exceeding m3 9 5.00 45.00


1.00m deep

E 1060mm width drain, maximum depth not exceeding m3 12 10.00 120.00


2.00m deep

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 66,097.00

E/ 3/4
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN 900MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN WITH
COVER SLAB TYPE D3 (CONT'd)

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

A 300mm Thick under precast U-drain m2 28 36.00 1,008.00

Lean concrete Grade 15 as specified :

B Under drain, not exceeding 100mm thick m3 1 325.00 325.00

Reinforced vibrated precast concrete Grade 30 as


described including all moulds, hoisting and setting
in cement mortar (1:3) :-

C 600mm long x 1060mm wide x 125mm thick drain cover no 44 113.00 4,972.00
finished fair on exposed surfaces and reinforced with and
including reinforcement bar of 10mm diameter at 100mm
centre high tensile, 6mm diameter at 200mm centre mild
steel complete with concrete work, rendering, formworks
and all necessary works.

______________

D 900mm wide x 900mm high precast concrete U-drain m 26 210.00 5,460.00


channel laid to fall embedded on crusher run (measure
separately)

(End of 900mm Wide (Internal) Precast Concrete U-Drain


With Cover Slab (Type D3)
THE FOLLOWING IN 600MM WIDE (INTERNAL
DIMENSION) CASCADE DRAIN

Excavate trench for drainage commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

E 740mm width drain, maximum depth not exceeding m3 6 5.00 30.00


1.00m

Lean concrete Grade 15 as specified :

F Under base not exceeding 100mm thick m3 1 325.00 325.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 12,120.00

E/ 3/5
BILL E : EXTERNAL WORKS

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN 600MM WIDE (INTERNAL


DIMENSION) CASCADE DRAIN (CONT'd)

Vibrated reinforced concrete Grade 30 as specified :

A In base, 300mm - 500mm thick m3 2 433.00 866.00

Layer of steel fabric reinforcement as described well


lapped at joints (measured nett-no allowance made
for laps)

In base

B Single layer BRC ref no. A6 (weighing not less than 2.61 m2 8 12.00 96.00
kg/m2)

Sawn formwork as specified :

C To edges and faces of base, not exceeding 250mm high m 14 11.25 157.50

Brickwork in cement sand bricks in cement and sand


(1:6) mortar with an approved plasticiser as specified
and reinforced with and including brick
reinforcement at every fourth course.

D 230mm thick brickwall m2 7 90.00 630.00

Cement and sand (1:3) finished with steel trowell,


trowelled hard and smooth as specified :

E 20mm thick rendering trowelled smooth to top and sides m2 10 18.00 180.00
of brickwall including forming splay at junction of drain

__________________________

F 300mm diameter precast half round glazed ware drain m 7 23.00 161.00
channel laid to fall embedded on concrete base

(End of 600mm wide Cascade Drain)

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 2,090.50

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

E/ 3/6
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING 600MM x 300MM PRECAST BOX


CULVERT (TYPE C1)

Excavate trench for pipe culvert commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

A For 740mm wide box culvert, maximum depth not m3 36 5.00 180.00
exceeding 1.00m deep

B For 740mm wide box culvert, maximum depth not m3 6 10.00 60.00
exceeding 2.00m deep

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

C 300mm Thick under precast box culvert m2 60 36.00 2,160.00

Lean concrete Grade 15 as specified :

D Under box culvert not exceeding 100mm thick m3 3 325.00 975.00

Precast Concrete Box Culvert

E 600mm x 300mm Class 'Z' box culvert complete with m 81 270.00 21,870.00
precast concrete lid and jointed with cement mortar and
laid in trench

(End of 600mm x 300mm Precast Box Culvert (Type C1))

THE FOLLOWING 600MM x 600MM PRECAST BOX


CULVERT (TYPE C2)

Excavate trench for pipe culvert commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

F For 740mm wide box culvert, maximum depth not m3 27 5.00 135.00
exceeding 1.00m deep

G For 740mm wide box culvert, maximum depth not m3 26 10.00 260.00
exceeding 2.00m deep

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 25,640.00

E/ 3/7
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING 600MM x 600MM PRECAST BOX


CULVERT (TYPE C2) (CONT'd)

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

A 300mm Thick under precast box culvert m2 53 36.00 1,908.00

Lean concrete Grade 15 as specified :

B Under box culvert not exceeding 100mm thick m3 3 325.00 975.00

Precast Concrete Box Culvert

C 600mm x 600mm Class 'Z' box culvert complete with m 72 300.00 21,600.00
precast concrete lid and jointed with cement mortar and
laid in trench

(End of 600mm x 600mm Precast Box Culvert (Type C2))

THE FOLLOWING 900MM x 900MM PRECAST BOX


CULVERT (TYPE C3)

Excavate trench for pipe culvert commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

D For 1060mm wide box culvert, maximum depth not m3 15 5.00 75.00
exceeding 1.00m deep

E For 1060mm wide box culvert, maximum depth not m3 108 10.00 1,080.00
exceeding 2.00m deep

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

F 300mm Thick under precast box culvert m2 95 36.00 3,420.00

Lean concrete Grade 15 as specified :

G Under box culvert not exceeding 100mm thick m3 5 325.00 1,625.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 30,683.00

E/ 3/8
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING 900MM x 900MM PRECAST BOX


CULVERT (TYPE C3) (CONT'd)

Precast Concrete Box Culvert


A 900mm x 900mm Class 'Z' box culvert complete with m 90 370.00 33,300.00
precast concrete lid and jointed with cement mortar and
laid in trench

(End of 900mm x 900mm Precast Box Culvert (Type C3))

THE FOLLOWING IN NOS. 34 BRICK SUMP


INTERNAL PLAN SIZE 900MM X 900MM (TYPE S1)

Excavate, get out, part return, fill in and ram and


deposit and spread in making up level where
directed within the site and remainder load and cart
away from site.

B Excavate pit for 1350mm x 1350mm brick sump m3 44 5.00 220.00


maximum depth not exceeding 1.00m deep

Vibrated reinforced concrete Grade 15 as specified:

C In base m3 9 325.00 2,925.00

Vibrated reinforced concrete Grade 30 as specified:

D In capping m3 8 325.00 2,600.00

Layer of steel fabric reinforcement as described well


lapped at joints (measured nett-no allowance made
for laps)

In base

E Single layer BRC ref no. A10 (weighing not less than m2 62 28.00 1,736.00
6.16 kg/m2)

Mild steel bar reinforcement to MS 146 as described


in :

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

In capping

F 6mm Diameter, as links kg 64 4.10 262.40

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 41,043.40

E/ 3/9
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN NOS. 34 BRICK SUMP


INTERNAL PLAN SIZE 900MM X 900MM (TYPE S1)
(CONT'd)

High tensile steel bar reinforcement to MS 146 as


described in :

In capping

A 10mm Diameter kg 109 4.10 446.90

Sawn Formwork as described:-

B To edges and faces of base not exceeding 250mm high m 184 11.25 2,070.00

C To edges and faces of capping not exceeding 250mm m 306 11.25 3,442.50
high

D EXTRA OVER for forming 50 x 75mm rebate m 122 8.00 976.00

Brickwork in cement and sand brick in cement and


sand (1:3) mortar with an approved plasticiser as
specified and reinforced with including brick
reinforcement at every fourth course:-

E 225mm thick brickwall m2 75 90.00 6,750.00

Cement and sand (1:3) with and approved plasticiser


plastering finished with straight-edge wood float as
specified :

F 20mm Thick to internal surfaces and top of wall m2 144 18.00 2,592.00

Mild steel grating as described :-

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

G Mild steel grating cover overall sizes 1050mm x 1050mm no 34 1,500.00 51,000.00
wide comprising of 40mm x 4mm thick mild steel flat bar
all around infill with 40mm x 4mm thick mild steel flat bar
at 32mm centres, 9mm thick galvanised as hinges all
welded together with and including painting on exposed
surface with one coat red oxide primer undercoat and
two finishing coats external quality gloss paint and
placing in position all as per approved by the S.O.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 67,277.40

E/ 3/10
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN NOS. 34 BRICK SUMP


INTERNAL PLAN SIZE 900MM X 900MM (TYPE S1)
(CONT'd)

Mild steel grating as described :- (CONT'd)

A Mild steel rubbish screen overall sizes 1050 x 900mm no 1 900.00 900.00
(average) high constructed of 50mm x 50mm x 4mm
thick mild steel angle frame, 10mm diameter mild steel
bar at 75mm centres all welded together and bolted to
sump wall with and including 8 nos of 12mm diameter
mild steel bolts, painting on exposed surface with one
coat red oxide primer undercoat and two finishing coats
external quality gloss paint and placing in position all as
per drawing no. PWW/21227/INF/RD/DET/02 and
approved by the S.O.

(End of 900mm x 900mm (Internal Dimension) Brick


Sump (Type S1))
THE FOLLOWING IN NOS. 6 BRICK SUMP INTERNAL
PLAN SIZE 1200MM X 1200MM (TYPE S2)

Excavate, get out, part return, fill in and ram and


deposit and spread in making up level where
directed within the site and remainder load and cart
away from site.

B Excavate pit for 1650mm x 1650mm brick sump m3 20 5.00 100.00


maximum depth not exceeding 1.00m deep

Vibrated reinforced concrete Grade 15 as specified:

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

C In base m3 2 325.00 650.00

Vibrated reinforced concrete Grade 30 as specified:

D In capping m3 2 325.00 650.00

Layer of steel fabric reinforcement as described well


lapped at joints (measured nett-no allowance made
for laps)

In base

E Single layer BRC ref no. A10 (weighing not less than m2 16 28.00 448.00
6.16 kg/m2)

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 2,748.00

E/ 3/11
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN NOS. 6 BRICK SUMP INTERNAL


PLAN SIZE 1200MM X 1200MM (TYPE S2) (CONT'd)

Mild steel bar reinforcement to MS 146 as described


in :

In capping

A 6mm Diameter, as links kg 13 4.10 53.30

High tensile steel bar reinforcement to MS 146 as


described in :

In capping

B 10mm Diameter kg 24 4.10 98.40

Sawn Formwork as described:-

C To edges and faces of base not exceeding 250mm high m 40 11.25 450.00

D To edges and faces of capping not exceeding 250mm m 68 11.25 765.00


high

E EXTRA OVER for forming 50 x 75mm rebate m 29 8.00 232.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Brickwork in cement and sand brick in cement and


sand (1:3) mortar with an approved plasticiser as
specified and reinforced with including brick
reinforcement at every fourth course:-

F 225mm thick brickwall m2 30 90.00 2,700.00

Cement and sand (1:3) with and approved plasticiser


plastering finished with straight-edge wood float as
specified :

G 20mm Thick to internal surfaces and top of wall m2 50 18.00 900.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 5,198.70

E/ 3/12
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

THE FOLLOWING IN NOS. 6 BRICK SUMP INTERNAL


PLAN SIZE 1200MM X 1200MM (TYPE S2) (CONT'd)

Mild steel grating as described :-

A Mild steel grating cover overall sizes 1350mm x 1350mm no 6 1,900.00 11,400.00
wide comprising of 40mm x 4mm thick mild steel flat bar
all around infill with 40mm x 4mm thick mild steel flat bar
at 32mm centres, 9mm thick galvanised as hinges all
welded together with and including painting on exposed
surface with one coat red oxide primer undercoat and
two finishing coats external quality gloss paint and
placing in position all as per approved by the S.O.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

B Mild steel rubbish screen overall sizes 1350 x 1090mm no 2 1,100.00 2,200.00
(average) high constructed of 50mm x 50mm x 4mm
thick mild steel angle frame, 10mm diameter mild steel
bar at 75mm centres all welded together and bolted to
sump wall with and including 8 nos of 12mm diameter
mild steel bolts, painting on exposed surface with one
coat red oxide primer undercoat and two finishing coats
external quality gloss paint and placing in position all as
per drawing no. PWW/21227/INF/RD/DET/02 and
approved by the S.O.

(End of 1200mm x 1200mm (Internal Dimension) Brick


Sump (Type S2))

WING WALL

C Construct and complete wing wall overall size 7,425mm x no 1 2,575.00 2,575.00
230mm wide x 900mm high constructed of 200mm thick
crusher run, 50mm thick lean concrete, 200 thick
reinforced concrete base with double layer BRC A8,
plastering with and including excavation works and all
necessary to engineer approval and drawing no.
PWW/21227/INF/RD/DE/01 & 05.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 16,175.00

E/ 3/13
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

DETENTION POND

A Construct and complete on side detention pond 30.0m x no 1 36,320.00 36,320.00


30.0m high constructed of reinforced concrete wingwall,
300mm diameter X 15.0m length pipe culvert, 600mm
diameter x 15.0m length pipe culvert, discharge sump
overall size 1200mm x 1200mm (internal dimension),
with and including excavation, slopes, turfing and all
necessary works as per drawing
no.PWW/21227/INF/RD/DET/05

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 36,320.00

E/ 3/14
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL


PROVISIONAL) (CONT'd)

COLLECTION PAGE

PAGE E/3/1 74,492.00

PAGE E/3/2 35,957.00

PAGE E/3/3 30,845.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

PAGE E/3/4 66,097.00

PAGE E/3/5 12,120.00

PAGE E/3/6 2,090.50

PAGE E/3/7 25,640.00

PAGE E/3/8 30,683.00

PAGE E/3/9 41,043.40

PAGE E/3/10 67,277.40

PAGE E/3/11 2,748.00

PAGE E/3/12 5,198.70

PAGE E/3/13 16,175.00

PAGE E/3/14 36,320.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 446,687.00

E/3/15
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL)

WATER RETICULATION

Excavate trench for large pipe commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

A To receive 160mm diameter pipe (incoming) not m 234 5.00 1,170.00


exceeding 2.00m

B To receive 160mm diameter pipe (hydrant) not m 346 5.00 1,730.00


exceeding 2.00m

C To receive 160mm diameter pipe (domestic) not m 468 5.00 2,340.00


exceeding 2.00m

Pipe Jacking

D Supply of labour, material and equipment for 180mm m 24 1,000.00 24,000.00


diameter (O.D) HDPE pipe PN16 as pipe casing for pipe
jacking works including all excavation planking and
strutting, pumping water, jointing and fixing all necessary
fitting and accessories, precast chamber, backfill with
approved material and cart away surplus excavated
material all as per specialist specification and
recommendation and approved by Local Authority.

Supply and lay the following in HDPE pipe (PN 16)


and fitting with electrofusion jointing as specification
:-

E 160mm Diameter (O.D) pipe (incoming) laid and jointed m 234 120.00 28,080.00
in trench

F 160mm Diameter (O.D) pipe (hydrant) laid and jointed in m 346 120.00 41,520.00
trench

G 160mm Diameter (O.D) pipe (domestic) laid and jointed m 468 120.00 56,160.00
in trench

H 160mm Diameter x 90 degree bend no 12 150.00 1,800.00

J 160mm Diameter x 45 degree bend no 22 150.00 3,300.00

K 160mm x 160mm x 160mm Diameter tee no 5 180.00 900.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 161,000.00

E/ 4/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Supply and lay the following in HDPE pipe (PN 16)


and fitting with electrofusion jointing as specification
:- (CONT'd)

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

A Selected fine sand backfill as specified spread and m3 1,284 40.00 51,360.00
levelled in trench

Concrete grade 25 as specified:-

B Thrust block as specified for pipe overall size 455mm x no 96 46.00 4,416.00
550mm x 200mm high and including all necessary
formwork and excavation

C Thrust block as specified for horizontal bend 90 degree no 12 175.00 2,100.00


overall size 1150mm x 760mm x 300mm high (extreme
size) and including all necessary formwork and
excavation

D Thrust block as specified for horizontal bend 45 degree no 22 135.00 2,970.00


overall size 850mm x 760mm x 300mm high (extreme
size) and including all necessary formwork and
excavation

E Thrust block as specified for horizontal tee overall size no 5 31.00 155.00
450mm x 350mm x 190mm high (extreme size) and
including all necessary formwork and excavation

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 61,001.00

E/ 4/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Pillar Hydrant

A 100mm Diameter (internal dimension) pillar hydrant with no 5 3,500.00 17,500.00


2 NOS x 65mm diameter outlet with cap and chain,
painted with yellow illuminous paint as specified
(measured flat overall), complete with 300mm x 300mm x
450mm thick concrete block (1:3:6 mix ) and including
500mm x 500mm x 500mm thick concrete trust block
(1:3:6 mix), 100mm diameter sluice valve, short piece
with double flanged jointing to pillar hydrant and 90
degree duckfoot medium bend, complete with precast
concrete chamber measuring 380mm x 430mm x 900mm
deep (internal dimension), sand filling, covered with
380mm x 430mm mild steel cover and mild steel frame,
100mm diameter pipe tapping from pipe line with
including all necessary excavation, formwork, backfilling
and cart away surplus excavated material including all
connection to water main pipe line all as per drawings
no. PWW/21227/INF/WR/DET/02

Sluice Valve

B 160mm Diameter cast iron sluice valve with 2 nos no 7 3,500.00 24,500.00
160mm diameter sluice valve, 1 nos altitude valve, 2 nos
plain ended straight pipe, 1 nos flange adaptor, 1 no
sluice valve complete with brick manhole constructed of
lean concrete, vibrated reinforced concrete base,
reinforcement, brickwall, reinforced concrete precast slab
cover with and including all necessary concrete
excavation, formwork, backfilling and cart away surplus
excavated material including all connection to incoming
pipe line and all accessories to complete the works in
accordance to AKSB requirements and drawing no.
PWW/21227/INF/ST/LP/02.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 42,000.00

E/ 4/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Bulk Meter

A Bulk meter complete with stand pipe, bend, Off-take tee no 2 5,000.00 10,000.00
sizes 150mm x 150mm x 50mm, kinetic air valve,
concentric taper, combination meter, butterfly valve worm
gear trpe 150mm diameter, 2 nos concrete achor block
grade 25 including all necessary welded collar,
excavation, formwork, backfilling and cart away surplus
excavated materials including all connection to main
pipeline and liason with AKSB as per drawing no.
PWW/21227/INF/WR/DET/03.

'S' Bend

B 'S' bend 6000mm long comprising of 160mm diameter no 4 5,000.00 20,000.00


mild steel pipe and 4 nos x 45 degree medium bend, 2
nos of short piece, unsheathed pipe, 100mm diameter x
6mm thick mild steel high tension bolt with plate sizes
100mm x 100mm x 3mm thick saddle strap, 50mm
diameter double orifice air valve , 2 nos 500mm long
steel flange/plain ended pipe complete with conrete blok,
2 nos of stub end and slip on flange with including all
necessary associated fittings, excavation and backfilling
all in accordance with AKSB requirement and drawing
no. PWW/21227/INF/WR/DET/02.

Marker Post

C Pipe marker post overall size 125mm x 125mm x no 14 100.00 1,400.00


1000mm high complete with countersunk number plate
and symbol all to required and approved by AKSB and
buried 450mm deep at all designated location including
all necessary excavation, disposal and reinforcement all
as per drawing no. PWW/21227/INF/WR/DET/03.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 31,400.00

E/ 4/4
BILL E : EXTERNAL WORKS

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Marker Post

A Sluice valve marker post overall size 125mm x 125mm x no 7 100.00 700.00
1000mm high complete with countersunk number plate
and symbol all to required and approved by AKSB and
buried 450mm deep at all designated location including
all necessary excavation, disposal and reinforcement all
as per drawing no. PWW/21227/INF/WR/DET/03.

Testing

B On completion of the installation of the water supply item 1 5,000.00 5,000.00


pipelines, test all pipings, fittings, hydrants, etc. for water
tightness, make good all defects and leave everything in
perfect working order to the entire satisfaction of the
Architect / S.O. and Local Authorities

C Allow for flushing and disinfecting the tested pipelines item 1 5,000.00 5,000.00
with chlorine bearing water to the satisfaction of the
Architect / S.O. and Local Authorities

D Allow for connection to existing 150mm diameter AKSB item 1 5,000.00 5,000.00
pipe.

SUCTION TANK

Work Below Lowest Floor Finish

Excavate surface to reduce level from formation level

E Average 400mm deep m3 10 5.00 50.00

Hardcore consisting of hard dry broken brick or


stone as described spread levelled, well
consolidated, watered and blinded with sand
topping, well rolled in and finished.

F 300mm Thick under ground slab m2 25 30.00 750.00

Lean concrete C12/15 as specified :

G Under slab not exceeding 100mm thick m3 1 325.00 325.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 16,825.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

E/ 4/5
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Vibrated reinforced waterproof concrete Grade 35 as


specified :

A In suction tank slab exceeding 300mm thick m3 8 433.00 3,464.00

B EXTRA OVER for forming thickening to underside of raft m 20 50.00 1,000.00


foundations for an additional depth of 200mm and an
average width of 300mm including all necessary
excavation, sawn formwork, sand blinding and hand
packing hardcore to slope on one side

High tensile steel bar reinforcement to MS 146 as


described in :

In suction tank slab

C 16mm Diameter as stirrup kg 402 4.10 1,648.20

D 16mm Diameter kg 1,327 4.10 5,440.70

Sawn formwork as specified:-

E To edges and faces of suction tank slab, 250mmm - m 20 17.00 340.00


500mm high

Cement and sand (1:4) protective screed to receive


water proofing membrance

F 32mm Thick paving to surfaces of suction tank slab m2 25 18.00 450.00

Prepare and apply an approved cementitious


waterproofing slurry and protective coating in
cement base material composed of two (2)
component polymer modified waterproof slurry
coating as described trowelled smooth all in
accordance to the manufacturer's specification:

G To surfaces of suction tank slab m2 25 40.00 1,000.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 13,342.90

E/ 4/6
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

A Supply and install cylinder tank overall size 3700mm item 1 12,000.00 12,000.00
diameter x 2900mm high x 5000 gallon with and
including all necessary work to engineer approval.

ELEVATED WATER TANK

Work Below Lowest Floor Finish

Excavate surface to reduce level from formation level

B Average 300mm deep m3 9 5.00 45.00

Excavate from reduce level get out, part return, fill in


and ram and deposit and spread in making up level
where directed within the site including preparing
slope and remainder load and cart away from site.

C Excavate pit for pile caps not exceeding 2.00m deep m3 5 15.00 75.00

D Excavate trench for ground beam not exceeding 0.25m m3 1 5.00 5.00
deep

Anti termite treatment againts subterranean termite


using termitticide chemical soil treatment after laying
of hardcore and prior to concreting and approved by
ministry of health including providing two (2) years
written guarantee

E Approved spray anti termiticide with 0.5% EC at 5 litre m2 77 2.50 192.50


per square metre or approved equivalent per
impregnation of soil surfaces as specified to underside of
the pile cap, ground slab, apron slab, ground beam, slab
and other structures as directed by the S.O's approval

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

F 150mm Thick under ground slab m2 18 18.00 324.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 12,641.50

E/ 4/7
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Layer of 0.25mm thick polythene sheet moisture


buried laid on lean concrete (measured separately)
with 300mm (minimum) laps at joints (measured nett-
no allowance made for laps)

A Under ground slab m2 18 3.00 54.00

Lean concrete C12/15 as specified :

B Under pile caps not exceeding 100mm thick m3 1 325.00 325.00

C Under ground beams not exceeding 100mm thick m3 1 325.00 325.00

D Under ground slab not exceeding 100mm thick m3 1 325.00 325.00

E Under apron slab not exceeding 100mm thick m3 1 325.00 325.00

Vibrated reinforced concrete C32/40 as specified :

F In pile caps m3 3 433.00 1,299.00

G In column stumps m3 1 433.00 433.00

H In ground beams m3 2 433.00 866.00

J In ground slab, 150mm - 300mm m3 2 433.00 866.00

K In apron slab laid to slope, 150mm - 300mm m3 1 433.00 433.00

L EXTRA OVER for forming thickening to underside of m 26 15.00 390.00


apron for an additional depth of 150mm and an average
width of 180mm including all necessary excavation, sawn
formwork, sand blinding and handpacking hardcore to
slope on one side

Layer of steel fabric reinforcement as described well


lapped at joints (measured nett-no allowance made
for laps) :

In ground slab

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

M Single layer BRC ref no. A6 (weighing not less than 2.61 m2 18 12.00 216.00
kg/m2)

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 5,857.00

E/ 4/8
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Layer of steel fabric reinforcement as described well


lapped at joints (measured nett-no allowance made
for laps) : (CONT'd)

In apron slab

A Single layer BRC ref no. A6 (weighing not less than 2.61 m2 18 12.00 216.00
kg/m2)

Mild steel bar reinforcement to MS 146 as described


in :

In column stump (Provisional)

B 10mm Diameter as link kg 34 4.10 139.40

In apron

C 10mm Diameter as starter bar kg 23 4.10 94.30

High tensile steel bar reinforcement to MS 146 as


described in :

In pile caps

D 12mm Diameter, as ties kg 73 4.10 299.30

E 16mm Diameter kg 180 4.10 738.00

In column stumps

F 25mm Diameter kg 510 4.10 2,091.00

In ground beams

G 10mm Diameter as stirrup kg 59 4.10 241.90

H 12mm Diameter kg 112 4.10 459.20

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Sawn formwork as specified:-

J To sides of pile caps, 500mm - 1.00m high m 17 33.00 561.00

K To sides of column stumps (Provisional) m2 6 45.00 270.00

L To edges and faces of ground beam, 250mm - 500m m 33 17.00 561.00


high

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 5,671.10

E/ 4/9
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Perimeter Drain

225mm Precast concrete (Grade 20-20mm) as


specified half round precast concrete drain with
minimun 20mm thick sides and bottom, cast in
suitable lengths, finished fair on exposed surfaces,
bedded, jointed and pointed in cement mortar (1:3),
on and including 525mm x 225mm thick mass
concrete (Grade 15-25mm) as specified bed, 115mm
thick brickwall on both sides, rendered on exposed
surfaces with 20mm thick cement and sand (1:6)
trowelled finish, including all necessary excavation,
formwork,junctions and ends including disposal of
surplus excavated material.

A Average 300mm deep m 27 45.00 1,215.00

Frame

Vibrated reinforced concrete C32/40 as specified :

B In columns m3 8 433.00 3,464.00

C In beams m3 10 433.00 4,330.00

High tensile steel bar reinforcement to MS 146 as


described in :

In column

D 10mm Diameter, as link kg 255 4.10 1,045.50

E 20mm Diameter kg 253 4.10 1,037.30

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

F 25mm Diameter kg 2,219 4.10 9,097.90

In beams

G 10mm Diameter as stirrup kg 348 4.10 1,426.80

H 12mm Diameter kg 529 4.10 2,168.90

J 20mm Diameter kg 104 4.10 426.40

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 24,211.80

E/ 4/10
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Frame (CONT'd)

High tensile steel bar reinforcement to MS 146 as


described in : (CONT'd)

In beams (CONT'd)

A 25mm Diameter kg 226 4.10 926.60

Sawn formwork as specified :

B To sides of column m2 73 45.00 3,285.00

C To sides and soffit of beams m2 90 45.00 4,050.00

Upper Floor

Vibrated reinforced concrete C32/40 as specified :

D In suspended slab, 150mm - 300mm thick m3 10 433.00 4,330.00

High tensile steel bar reinforcement to MS 146 as


described in :

In suspended platform slab

E 16mm Diameter as bar kg 1,042 4.10 4,272.20

Sawn formwork as specified :

F To soffit of suspended slab m2 34 45.00 1,530.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

G To edges of slab not exceeding 250mm high m 18 11.30 203.40

Cement and sand (1:4) protective screed to receive


water proofing membrance

H 32mm Thick paving to surfaces of suspended slab m2 41 20.00 820.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 19,417.20

E/ 4/11
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Prepare and apply an approved cementitious


waterproofing slurry and protective coating in
cement base material composed of two (2)
component polymer modified waterproof slurry
coating as described trowelled smooth all in
accordance to the manufacturer's specification:

A To surfaces of suspended slab m2 41 45.00 1,845.00

Balustrades and Handrail

Galvanised iron all welded and bolted together and


finished with one coat red oxide primer and two
coats approved gloss point

B 38mm Diameter galvanised iron pipe as baluster, 900mm m 13 35.00 455.00


high at 1500mm centre to centre

C 32mm Diameter galvanised iron pipe as handrail m 19 38.00 722.00

D 32mm Diameter galvanised iron pipe as intermediate rail m 19 38.00 722.00

Mild steel as described

E 150mm x 150mm x 10mm thick mild steel plate no 14 12.00 168.00

F 12mm Diameter rawl bolt, 150mm long no 56 2.00 112.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Staircase

Vibrated reinforced concrete C32/40 as specified :

G In staircase m3 4 433.00 1,732.00

H In beam m3 2 433.00 866.00

J In landing slab, 100mm - 150mm thick m3 1 433.00 433.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 7,055.00

E/ 4/12
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

High tensile steel bar reinforcement to MS 146 as


described in :

In staircase and landing slab

A 10mm Diameter as bar kg 228 4.10 934.80

In beam

B 10mm Diameter as stirrup kg 68 4.10 278.80

C 20mm Diameter as bar kg 524 4.10 2,148.40

Sawn formwork as specified :

D To sloping soffit of staircase m2 18 45.00 810.00

E To soffit of landing slab m2 11 45.00 495.00

F To edges of slab not exceeding 250mm high m 22 11.30 248.60

G To sides and soffit of beam m2 21 45.00 945.00

H To sides of raking open string of staircase 400mm m 36 27.00 972.00


(extreme) width, including cutting to profile of treads and
risers.

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

J To undercut riser 188mm high m 63 8.00 504.00

Cement and sand (1:6) with steel trowel as


specified :-

K 20mm Thick finished to landing slab m2 11 22.00 242.00

L 20mm Thick finished to undercut riser, 188mm high m 63 4.00 252.00

M 20mm Thick finished to treads, 237mm wide m 60 5.00 300.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 8,130.60

E/ 4/13
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

FINISHES
Cement and sand (1:6) with an approved plasticiser
plastering finished with straight- edge wood float as
specified :- (CONT'd)

A 20mm Thick, plastering to columns, beams, soffit of m2 215 22.00 4,730.00


staircase and soffit of suspended slab.

Prepare and apply one coat primer sealer and two


coats exterior acrylic resisting weathershield

B To smooth surfaces of soffit of to columns, beams and m2 215 10.00 2,150.00


soffit landing slab.

C To smooth surfaces of sides and soffit of beam m2 21 10.00 210.00

D To smooth surfaces of soffit of landing slab m2 11 10.00 110.00

E To smooth surfaces of sides of raking open string of m 63 6.00 378.00


stairs, 600mm (extreme) wide and including working
around tread and riser profile

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Balustrades and Handrail

Galvanised iron all welded and bolted together and


finished with one coat red oxide primer and two
coats approved gloss point

F 38mm Diameter galvanised iron pipe as baluster, 900mm m 31 35.00 1,085.00


high at 1500mm centre to centre

G 32mm Diameter galvanised iron pipe as handrail m 47 38.00 1,786.00

H 32mm Diameter galvanised iron pipe as intermediate rail m 47 38.00 1,786.00

Mild steel as described

J 80mm x 80mm x 6mm thick mild steel plate no 26 3.00 78.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 12,313.00

E/ 4/14
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Mild steel as described (CONT'd)

A 150mm x 150mm x 10mm thick mild steel plate no 8 12.00 96.00

B 12mm Diameter rawl bolt, 150mm long no 32 2.00 64.00

C 6mm Diameter anchor bar, 200mm long no 26 0.80 20.80

Plumbing

D Supply and install 100mm diameter mild steel with m 37 211.00 7,807.00
cement lining pipe complete with puddle collar, socket,
bend, valve, anchor block with and including excavation
work and all necessary work to engineer approval and
drawing no. PWW/21227/INF/EWT/LP/01

Elevated Water Storage Tank

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

E To supply and install one unit of 10,000 gallons Fibre- no 1 28,000.00 28,000.00
reinforced polymer (FRP) tank, with overall size
4,000mm diameter x 3,610mm high. The tanks comes
complete with internal stainless steel cat ladder, external
aluminium cat ladder complete with platform and all
necessary works and fittings with 10 years
manufacturer's warranty to engineer approval.

PUMP HOUSE

Work Below Lower Floor Finish

Note: All excavation are measured from formation


level, unless otherwise stated.

Excavate surface to reduce level from formation level

F Average 450mm deep m3 25 5.00 125.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 36,112.80

E/ 4/15
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

PUMP HOUSE (CONT'd)

Anti termite treatment againts subterranean termite


using termitticide chemical soil treatment after laying
of hardcore and prior to concreting and approved by
ministry of health including providing two (2) years
written guarantee

A Approved spray anti termiticide with 0.5% EC at 5 litre m2 36 2.50 90.00


per square metre or approved equivalent per
impregnation of soil surfaces as specified to underside of
the raft foundation and apron slab and other structures
as directed by the S.O's approval

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Hardcore consisting of hard dry broken brick or


stone as described spread levelled, well
consolidated, watered and blinded with sand
topping, well rolled in and finished.

B 150mm Thick under raft foundations m2 18 12.00 216.00

C 150mm Thick under apron slabs m2 18 12.00 216.00

________________________
D Selected sand backfill as specified spread and levelled m3 11 40.00 440.00
as described

E Supply and lay high strength woven geotextile to m2 36 5.00 180.00


manufacturer instruction as spesified

Layer of 0.25mm thick polythene sheet moisture


buried laid on lean concrete (measured separately)
with 300mm (minimum) laps at joints (measured nett-
no allowance made for laps)

F Under raft foundation m2 18 5.00 90.00

G Under apron slab m2 18 5.00 90.00

Lean concrete C12/15 as specified :

H Under raft foundation, not exceeding 100mm thick m3 1 325.00 325.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 1,647.00

E/ 4/16
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

PUMP HOUSE (CONT'd)

Lean concrete C12/15 as specified : (CONT'd)

A Under apron slab, not exceeding 100mm thick m3 1 325.00 325.00

Vibrated reinforced concrete C32/40 as specified :

B In raft foundation, 150mm - 300mm m3 4 433.00 1,732.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

C EXTRA OVER for forming thickening to underside of raft m 17 5.00 85.00


foundations for an additional depth of 300mm and an
average width of 400mm including all necessary
excavation, sawn formwork, sand blinding and hand
packing hardcore to slope on one side

D In apron slab laid to slope not exceeding 100mm m3 2 433.00 866.00

High tensile steel bar reinforcement to MS 146 as


described in :

In raft foundation

E 10mm Diameter kg 176 4.10 721.60

In thickening

F 10mm Diameter kg 60 4.10 246.00

G 16mm Diameter kg 63 4.10 258.30

H 25mm Diameter kg 142 4.10 582.20

In apron slab

J 10mm Diameter kg 228 4.10 934.80

Sawn formwork as specified :-

K To edges and faces of raft foundation, 250mm-500mm m 17 45.00 765.00


high

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 6,515.90

E/ 4/17
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

RAMP

Vibrated reinforced concrete C32/40 as specified :

A In ramp slab laid to slope, 100mm - 150mm m3 1 433.00 433.00

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

High tensile steel bar reinforcement to MS 146 as


described in :

In ramp slab

B 10mm Diameter kg 18 4.10 73.80

Sawn formwork as specified :-

C To sides of ramp m2 1 40.00 40.00

Cement and sand (1:3) finish with steel trowel as


specified :

D 20mm thick paving to ramp slab including forming 10mm m2 2 18.00 36.00
half round groove line at 50mm centres

PERIMETER DRAIN

Note: All excavation are measured from formation


level, unless otherwise stated.

Excavate from reduce level get out, part return, fill in


and ram and deposit and spread in making up level
where directed within the site including preparing
slope and remainder load and cart away from site.

E Excavate trench for perimeter drain maximum depth not m3 8 5.00 40.00
exceeding 1.00mm deep

Hardcore consisting of hard dry broken brick or


stone as described spread levelled, well
consolidated, watered and blinded with sand
topping, well rolled in and finished.

F 150mm Thick under perimeter drain m2 16 12.00 192.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 814.80

E/ 4/18
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

PERIMETER DRAIN (CONT'd)

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

A Selected sand backfill as specified spread and levelled m3 5 40.00 200.00


as described

B Supply and lay high strength woven geotextile to m2 16 3.00 48.00


manufacturer instruction as spesified

Lean concrete C12/15 as specified :

C Under perimeter drain, not exceeding 100mm thick m3 1 325.00 325.00

Vibrated reinforced concrete C32/40 as specified :

D In perimeter drain wall, 150mm - 300mm m3 3 433.00 1,299.00

E In perimeter drain slab, 150mm - 300mm m3 2 433.00 866.00

High tensile steel bar reinforcement to MS 146 as


described in :

In perimeter drain wall and slab

F 10mm Diameter kg 364 4.10 1,492.40

Sawn formwork as specified :-

G To edges and faces of perimeter drain wall, 250mm- m 101 17.00 1,717.00
500mm high

Cement and sand (1:6) with an approved plasticier


plastering finished with straight- edge wood float as
specified

H 20mm Thick to internal surfaces of wall, sides and top of m2 26 20.00 520.00
concrete wall.

__________________________
J 280mm wide x 140mm high precast concrete half round m 25 22.00 550.00
drain laid to fall embedded on concrete slab (measure
separately)

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 7,017.40

E/ 4/19
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

05/08/2024 - 07:05:06
JKR E-Tender | SD210723

Frame

Vibrated reinforced concrete C32/40 as specified :

A In columns m3 1 433.00 433.00

B In stiffeners (Provisional) m3 1 433.00 433.00

C In roof beams m3 1 433.00 433.00

Mild steel bar reinforcement to MS 146 as described


in :

In columns

D 10mm Diameter as link kg 61 4.10 250.10

High tensile steel bar reinforcement to MS 146 as


described in :

In column

E 16mm Diameter kg 24 4.10 98.40

In stiffeners (Provisional)

F 10mm Diameter, as started bar kg 5 4.10 20.50

G 10mm Diameter, as links kg 22 4.10 90.20

H 12mm Diameter kg 26 4.10 106.60

In roof beams

J 10mm Diameter as stirrups kg 54 4.10 221.40

K 12mm Diameter kg 31 4.10 127.10

L 16mm Diameter kg 56 4.10 229.60

Sawn formwork as specified :-

M To sides of column m2 17 45.00 765.00

N To sides of stiffeners (Provisional) m2 4 45.00 180.00

P To sides and soffit of roof beams m2 18 45.00 810.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 4,197.90

E/ 4/20
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Roof

PREFABRICATED COLD FORMED STEEL ROOF


TRUSS SYSTEM

Notes:

Notwithstanding the Standard Method Measurement


2nd edition, this item is measured in Square Metre
(M2)

Steel roof trusses components shall be


manufactured and assembled only by truss
fabricators accredited by system provider.

The design, supply, delivery and erection of the


trusses shall be in accordance with JKR Standard
Specifications for Prefabricated Cold Formed Steel
Roof Trusses.

The Contractor is to submit together with his Tender


shop drawing duly endorsed by a Professional
Engineer and all other documentation as mentioned
in the JKR Standard Specifications for Prefabricated
Cold Formed Steel Roof Trusses.

The Contractor is to seek the S.O's approval prior to


any work on the roof structure.

(End of Notes)

Design, fabricate, supply, deliver, erect and install


complete in position prefabricated cold formed steel
roof trusses as described and providing ten (10)
years warranty :-

A Roof trusses system including hoisting and fixing into m2 42 92.00 3,864.00
position 3.60m high from ground level

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 3,864.00

E/ 4/21
BILL E : EXTERNAL WORKS

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

ROOF COVERING

An approved concrete roof tiles laid to pitch roof on


Prefabricated Cold Formed Steel Roof Trusses all in
accordance with the manufacturer's instruction
(measured nett-no allowance made for laps)

A Roof covering laid to 25 degree pitch m2 40 40.00 1,600.00

B Hip tile to match roof covering bedded, jointed and m 19 25.00 475.00
pointed in cement mortar grouting

C 4 way apex to match roof covering bedded, jointed and no 1 40.00 40.00
pointed in cement mortar grouting

Insulation work as specified :

D 50mm Thick x 60kg/m3 rockwool insulation laid on m2 40 8.00 320.00


aluminium foil (measured separately) all in accordance
with manufacturer's instruction (measured nett-no
allowance made for laps)

E One layer of an approved galvanized wire mesh m2 40 6.00 240.00


BRC3316 laid securely to c-purlin and pulled out end to
end (measured nett-no allowance made for laps)

Sisalation as specified :

F Double sided aluminium foil sisalation as described laid m2 40 10.00 400.00


strictly in accordance with manufacturer's instruction or
and well lapped at joints (measured nett-no allowance
made for laps).

Wrot pressure treated S.G.1 & S.G.2 timber as


described :

G 200mm x 20mm Thick fascia board m 24 25.00 600.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 3,675.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

E/ 4/22
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Knot, prime, stop and paint one undercoat and two


finishing coats to gloss enamel paint with Eco
Labelling Certificate from SIRIM as specified on
woodworks:

A General surfaces of fascia board m2 11 10.00 110.00

External Wall

Brickwork in cement and sand bricks in cement


mortar (1:3) as specified and reinforced with and
including brick reinforcement at every fourth course.

B 110mm thick wall m2 37 40.00 1,480.00

Bituminous sheet damp proof course as specified


(measured nett-no allowance made for laps)

C 110mm wide m 10 2.50 25.00

Bonding ties as specified

D 6mm Diameter mild steel wall bonding ties, 450mm long no 48 1.00 48.00
at 600mm centres, one end cast into concrete and the
other end built into joints of brickwall as work proceeds.

Door

Reinforced vibrated precast concrete Grade 20 as


described including all moulds, hoisting and setting
in cement mortar (1:3) :-

E 125mm x 200mm lintol reinforced with and including 4 m 3 12.00 36.00


nos. 12mm diameter high tensile steel bar and 10mm
diameter high tensile as stirrups at 175mm centre.

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 1,699.00

E/ 4/23
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Door (CONT'd)

Supply and fix natural anodised aluminium frame


light duty 1.0mm thick roller shutters manually
operated complete with lighting gears, roller drums,
slides guides and all accessories including building
in or cutting and pinning lugs, bedding and pointing
guides in cement mortar (1:3) all in accordance with
the manufacturer's instructions

A Roller shutter to suit opening size 2800mm x 3000mm no 1 2,520.00 2,520.00


high (Type RS1)

Window

Reinforced vibrated precast concrete Grade 20 as


described including all moulds, hoisting and setting
in cement mortar (1:3) :-

B 125mm x 200mm lintol reinforced with and including 4 m 2 12.00 24.00


nos. 12mm diameter high tensile steel bar and 10mm
diameter high tensile as stirrups at 175mm centre.

Supply and install 0.80mm thick white powder coated


aluminium frame casement window and fixed glass
panel with and including approval glass (measured
separately) and glazing gasket complete with all
requisite silicone sealant fillets, casement friction
stay, fasteners and fixing lugs all in accordance to
manufacturer's details and S.O approval.

C Top hung window overall size 1800mm x 450mm high no 1 119.00 119.00
comprising of 3 nos top hung size 600mm x 450mm high

Internal Finishes

Floor

Cement and sand (1:3) rendering, trowelled hard and


smooth as specified:

D 25mm thick paving m2 16 18.00 288.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 2,951.00

E/ 4/24
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Wall

Cement and sand (1:6) with an approved plasticiser


plastering finished with steel trowelled smooth as
specified :-

A 20mm Thick, plastering to walls, columns and beams. m2 47 22.00 1,034.00

Prepare and apply one coat of primer and two coats


of emulsion paint with washable/anti-bacteria and
Eco Labelling Certificate from SIRIM as specified
(EMP) :

B To surfaces of plastered walls, columns and beams. m2 37 8.00 296.00

Ceiling

Gypsum board (GB) :

C An approved 9mm Thick gypsum board ceiling as m2 15 50.00 750.00


specified set out symetrically and fixing to and including
framing and suspension system complete with all
necessary accessories and manufacturer's instruction
and S.O approval.(GB)

Prepare and apply one coat of primer and two coats


of emulsion paint with washable/anti-bacteria and
Eco Labelling Certificate from SIRIM as specified
(EMP) :

D Finish to gypsum board m2 15 8.00 120.00

External Finishes

Floor

Cement and sand (1:3) rendering, trowelled hard and


smooth as specified:

E 25mm thick paving to apron slab m2 19 18.00 342.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 2,542.00

E/ 4/25
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

Wall

Cement and sand (1:6) with an approved plasticiser


plastering finished with straight- edge wood float as
specified :-

A 20mm Thick, plastering to walls, columns and beams. m2 53 22.00 1,166.00

Prepare and apply one coat of primer sealer and two


coats of exterior acrylic resisting weathershield paint
with Eco Labelling certificate from SIRIM as specified
and providing eight (8) years warranty :

B To surfaces of plastered walls, columns and beams. m2 53 10.00 530.00

Ceiling

Gypsum board (GB) :

C An approved 9mm Thick gypsum board ceiling as m2 19 50.00 950.00


specified set out symetrically and fixing to and including
framing and suspension system complete with all
necessary accessories and manufacturer's instruction
and S.O approval.(GB)

Prepare and apply one coat of primer sealer and two


coats of exterior acrylic resisting weathershield paint
with Eco Labelling certificate from SIRIM as specified
and providing eight (8) years warranty :

D Finish to gypsum board m2 19 10.00 190.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 2,836.00

E/ 4/26
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E4 - WATER RETICULATION, SUCTION


TANK AND ELEVATED WATER TANK (ALL
PROVISIONAL) (CONT'd)

COLLECTION PAGE

PAGE E/4/1 161,000.00

PAGE E/4/2 61,001.00

PAGE E/4/3 42,000.00

PAGE E/4/4 31,400.00

PAGE E/4/5 16,825.00

PAGE E/4/6 13,342.90

PAGE E/4/7 12,641.50

PAGE E/4/8 5,857.00

PAGE E/4/9 5,671.10

PAGE E/4/10 24,211.80

PAGE E/4/11 19,417.20

PAGE E/4/12 7,055.00

PAGE E/4/13 8,130.60

PAGE E/4/14 12,313.00

PAGE E/4/15 36,112.80

PAGE E/4/16 1,647.00

PAGE E/4/17 6,515.90

PAGE E/4/18 814.80

PAGE E/4/19 7,017.40

PAGE E/4/20 4,197.90

PAGE E/4/21 3,864.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

PAGE E/4/22 3,675.00

PAGE E/4/23 1,699.00

PAGE E/4/24 2,951.00

PAGE E/4/25 2,542.00

PAGE E/4/26 2,836.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 494,738.90

E/4/27
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E5 - SEWERAGE RETICULATION AND


SEWERAGE TREATMENT SYSTEM (ALL
PROVISIONAL)

SEWERAGE RETICULATION

Excavate trench for pipe commencing from ground


level, get out part return, filling and ram and remove
surplus excavated material form site

A Trench for 225mm diameter pipe, 525mm wide not m 203 15.00 3,045.00
exceeding 2.00m depth

B Trench for 225mm diameter pipe, 525mm wide not m 136 20.00 2,720.00
exceeding 4.00m depth

C Trench for 150mm diameter pipe, 450mm wide not m 56 5.00 280.00
exceeding 1.00m depth

D Trench for 150mm diameter pipe, 450mm wide not m 246 15.00 3,690.00
exceeding 2.00m depth

Vitrified Clay Pipes as specified and including all


necessary fitting

E 225mm Diameter pipe in spigot and socket rubber ring m 339 130.00 44,070.00
joint and laid to fall in trench.

F 150mm Diameter pipe in spigot and socket rubber ring m 302 100.00 30,200.00
joint and laid to fall in trench.

___________________

G An approved crusher run compacted as specified m3 58 120.00 6,960.00


bedding to Engineer's approval

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 90,965.00

E/ 5/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E5 - SEWERAGE RETICULATION AND


SEWERAGE TREATMENT SYSTEM (ALL
PROVISIONAL) (CONT'd)

PRECAST CONCRETE MANHOLE

The Following In Nos. 13 Precast Concrete Manholes

An approved precast concrete manhole system


comprising precast concrete chamber ring, make-up
ring, heavy duty duck iron frame and cover, cast in-
situ concrete surround with 150mm thick Grade 25P
mass concrete all round and laid on cast in-situ
chamber ring, 400mm thick base concrete Grade 25P
reinforced with reinforcement bar on 50mm thick
cementitious blinding and including 225mm diameter
half round VCP, socket piece, bend, concrete
benching, corrugated stainless steel steps iron at
300mm centres vertically, 20mm thick high alumina
cement mortar with two (2) layer of coal tar epoxy
complete with all necessary work with including all
necessary formwork, excavation, strutting of
excavated pit, with sheet piles (if necessary)
backfilling etc. all shown in relevant drawings.

A 1200mm Internal diameter exceeding 1.00m and not no 2 2,500.00 5,000.00


exceeding 1.50m deep to invert (Type A)

B 1200mm Internal diameter exceeding 1.00m and not no 1 2,500.00 2,500.00


exceeding 1.50m deep to invert (Type B)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

C 1200mm Internal diameter exceeding 1.50m and not no 1 3,500.00 3,500.00


exceeding 2.00m deep to invert (Type B)

D 1200mm Internal diameter exceeding 1.50m and not no 2 3,500.00 7,000.00


exceeding 2.00m deep to invert (Type C)

E 1200mm Internal diameter exceeding 1.50m and not no 2 3,500.00 7,000.00


exceeding 2.00m deep to invert (Type D)

F 1200mm Internal diameter exceeding 2.00m and not no 2 4,000.00 8,000.00


exceeding 2.50m deep to invert (Type C)

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 33,000.00

E/ 5/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E5 - SEWERAGE RETICULATION AND


SEWERAGE TREATMENT SYSTEM (ALL
PROVISIONAL) (CONT'd)

An approved precast concrete manhole system


comprising precast concrete chamber ring, make-up
ring, heavy duty duck iron frame and cover, cast in-
situ concrete surround with 150mm thick Grade 25P
mass concrete all round and laid on cast in-situ
chamber ring, 400mm thick base concrete Grade 25P
reinforced with reinforcement bar on 50mm thick
cementitious blinding and including 225mm diameter
half round VCP, socket piece, bend, concrete
benching, corrugated stainless steel steps iron at
300mm centres vertically, 20mm thick high alumina
cement mortar with two (2) layer of coal tar epoxy
complete with all necessary work with including all
necessary formwork, excavation, strutting of
excavated pit, with sheet piles (if necessary)
backfilling etc. all shown in relevant drawings.
(CONT'd)

A 1200mm Internal diameter exceeding 2.00m and not no 1 4,000.00 4,000.00


exceeding 2.50m deep to invert (Type E)

B 1200mm Internal diameter exceeding 2.50m and not no 1 5,000.00 5,000.00


exceeding 3.00m deep to invert (Type D)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

C 1200mm Internal diameter exceeding 2.50m and not no 1 5,500.00 5,500.00


exceeding 3.00m deep to invert (Type E)

____________________

D 840mm x 840mm Approved heavy duty manhole cover no 13 800.00 10,400.00


with `KUMBAHAN' embossed logo at centre including
bedding frame in cement and sand (1:3) and sealing
cover with grease and painting with two coats of
bituminious paint all as per drawing no.
PWW/21227/INF/SW/DET/02

(End Of 13 Nos. Precast Concrete Manhole)

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 24,900.00

E/ 5/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E5 - SEWERAGE RETICULATION AND


SEWERAGE TREATMENT SYSTEM (ALL
PROVISIONAL) (CONT'd)

600MM X 600MM (INTERNAL PLAN) INSPECTION


CHAMBER

Excavate from formation level get out, part return, fill


in and ram and deposit and spread in making up
level where directed within the site including
preparing slope and remainder load and cart away
from site.

A Excavate pit for 1050mm x 1050mm inspection chamber m3 15 5.00 75.00


maximum depth not exceeding 1.00m deep

B Excavate pit for 1050mm x 1050mm inspection chamber m3 38 10.00 380.00


maximum depth not exceeding 2.00m deep

Mass concrete Grade 20 as specified :

C In base m3 5 350.00 1,750.00

D In haunching m3 2 350.00 700.00

E In coping m3 5 350.00 1,750.00

Sawn formwork as specified :

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

F To edges and faces of base, not exceeding 250mm high m 126 17.00 2,142.00

G To sides of coping, not exceeding 250mm high m 198 11.00 2,178.00

H EXTRA OVER for forming 25mm x 50mm rebate m 72 5.00 360.00

Brickwork in cement and sand bricks in cement and


sand (1:6) mortar with an approved plasticiser as
specified and reinforced with and including brick
reinforcement at every fourth course.

J 225mm thick wall m2 78 90.00 7,020.00

High alumina cement and sand (1:3) with an


approved plasticiser as specified:-

K 20mm Thick to internal surfaces of wall, sides and top of m2 168 18.00 3,024.00
coping.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 19,379.00

E/ 5/4
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E5 - SEWERAGE RETICULATION AND


SEWERAGE TREATMENT SYSTEM (ALL
PROVISIONAL) (CONT'd)

600MM X 600MM (INTERNAL PLAN) INSPECTION


CHAMBER (CONT'd)

A 13mm thick x 650mm x 650mm cast iron cover complete no 30 400.00 12,000.00
with all necessary work and placing in position all as per
drawing and S.O approval

SMALL SEWERAGE TREATMENT SYSTEM

B Supply and install Small Sewerage Treatment System no 1 50,000.00 50,000.00


(SSTS) Model AN 100EA2 - 100PE complete with inlet
chamber, pump sump, secondary screen chamber,
grit/grease chamber, distribution chamber, primary
sedimentation tank, aeration tank, secondary
sedimentation tank, flow measument chamber, air pump
house piping with and including all necessary excavation,
concrete work, hoisting, placing with all necessary fitting
and accessories and other related works to manufacture
detail and instruction and engineers drawing no.
PWW/21227/INF/SW/DET/08 & 09.

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

Testing

C Test the whole of the sewerage reticulation system in the item 10,000.00
presence of the S.O. with CCTV monitoring for the length
of 30m long or the longest manhole to mahole and
testing with water or the other approved means before
trenches are filled in, make good any defects, re-test
again on completion and leave the whole in perfect
working order to the entire satisfaction on the Engineer /
S.O.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 72,000.00

E/ 5/5
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E5 - SEWERAGE RETICULATION AND


SEWERAGE TREATMENT SYSTEM (ALL
PROVISIONAL) (CONT'd)

COLLECTION PAGE

PAGE E/5/1 90,965.00

PAGE E/5/2 33,000.00

PAGE E/5/3 24,900.00

PAGE E/5/4 19,379.00

PAGE E/5/5 72,000.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 240,244.00

E/5/6
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E6 - FENCING & GATE (ALL PROVISIONAL)

MAIN FENCING AND GATE

Main Entrance Gate

Work Below Lowest Floor Finish

Excavate from reduce level get out, part return, fill in


and ram and deposit and spread in making up level
where directed within the site including preparing
slope and remainder load and cart away from site.

A Excavate pit for pad footing maximum depth not m3 8 10.00 80.00
exceeding 2.00mm deep (Provisional)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

B Excavate trench for ground beam maximum depth not m3 1 5.00 5.00
exceeding 1.00mm deep

Lean concrete C12/15 as specified :

C Under pad footing, not exceeding 100mm thick m3 1 325.00 325.00

D Under ground beam, not exceeding 100mm thick m3 1 325.00 325.00

Vibrated reinforced concrete C32/40 as specified :

E In pad footing m3 3 433.00 1,299.00

F In columns stumps (Provisional) m3 2 433.00 866.00

G In ground beam m3 3 433.00 1,299.00

High tensile steel bar reinforcement to MS 146 as


described in :

In pad footing

H 12mm Diameter kg 198 4.10 811.80

In column stumps (Provisional)

J 10mm Diameter, as links kg 92 4.10 377.20

K 12mm Diameter kg 94 4.10 385.40

In ground beam

L 10mm Diameter, as stirrups kg 87 4.10 356.70

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 6,130.10

E/ 6/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E6 - FENCING &GATE (ALL PROVISIONAL)


(CONT'd)

In ground beam (CONT'd)

A 12mm Diameter kg 94 4.10 385.40

Sawn formwork as specified :-

B To edges and faces of pad footing, not exceeding m 34 11.00 374.00


250mm high

C To sides of column stumps (Provisional) m2 15 45.00 675.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

D To edges and faces of ground beam, 250mm - 500mm m 44 17.00 748.00


high

Frame

Vibrated reinforced concrete C32/40 as specified :

E In columns m3 3 433.00 1,299.00

High tensile steel bar reinforcement to MS 146 as


described in :

In columns

F 10mm Diameter, as links kg 162 4.10 664.20

G 12mm Diameter kg 130 4.10 533.00

Sawn formwork as specified :-

H To sides of column m2 28 45.00 1,260.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 5,938.60

E/ 6/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E6 - FENCING & GATE (ALL PROVISIONAL)


(CONT'd)

Wall

Reinforced vibrated precast concrete Grade 20 as


described including all moulds, hoisting and setting
in cement mortar (1:3) :- (CONT'd)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

A 50mm wide x 50mm thick precast coping with pattern m 49 25.00 1,225.00
finished fair on exposed surfaces and reinforced with and
including 4 nos 10 mm diameter high tensile steel bar
and 6mm diameter mild as stirrup at 200mm centre. (To
Archway)

Brickwork in cement sand bricks in cement mortar


(1:3) as specified and reinforced with and including
brick reinforcement at every fourth course.

B 110mm thick wall m2 15 45.00 675.00

Bonding ties as specified

C 6mm Diameter mild steel wall bonding ties, 450mm long no 24 1.00 24.00
at 600mm centres, one end cast into concrete and the
other end built into joints of brickwall as work proceeds.

Wall finishes

Cement and sand (1:6) with an approved plasticiser


plastering finished with straight- edge wood float as
specified :-

D 20mm Thick, plastering to walls and columns. m2 58 22.00 1,276.00

Prepare and apply one coat of primer sealer and two


coats of exterior acrylic resisting weathershield paint
with Eco Labelling certificate from SIRIM as specified
and providing eight (8) years warranty :

E To surfaces of plastered walls, columns and beams. m2 58 10.00 580.00

F To surfaces of 50mm x 50mm thick precast concrete m 49 5.00 245.00


coping

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 4,025.00

E/ 6/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E6 - FENCING & GATE (ALL PROVISIONAL)


(CONT'd)

Mild steel as described :-

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

A Construct and complete mild steel balustrade overall size no 2 1,000.00 2,000.00
1550mm x 1200mm high constructed of 5mm thick mild
steel hollow section with islamic pattern all welded
together and fix to column, painting with and including all
necessary work as per drawing no.
KN/ALA/646/07/2021/30, PWW/21227/MEG/RC/LP/01.

B Construct and complete mild steel gate overall size no 2 7,000.00 14,000.00
6000mm x 1800mm high constructed of 100mm x 50mm
x 5mm thick mild steel rectangular hollow section as
framing with islamic pattern all welded together and fix to
column, painting with and including all necessary work as
per drawing no. KN/ALA/646/07/2021/30,
PWW/21227/MEG/RC/LP/01.

C Construct and complete 1500mm high security fencing m 597 230.00 137,310.00
constructed of fencing, panel, post, with and including
excavation, reinforced concrete, reinforcement,
formwork, fixing and all necessary work to architect
approval.

FENCING AND GATE AT SEWERAGE TREAMENT


PLANT
D PVC coated chain link fencing overall high 1900mm high, no 61 120.00 7,320.00
comprising of 63.5mm x mesh B/65mm B/11G gauge
PVC coated chain link including three strand fixed to
angle post, 75mm x 75mm x 5mm thick angle post
embedded concrete stump, 50mm diameter x 5.75 kg/m
circular hollow section strut, mass concrete stump sizes
300mm x 300mm x 760mm deep (1:3:6 aggregate),
mass concrete kerb sizes 100mm x 150mm (1:3:6
aggregate) complete with all requisite cutting, jointing,
welding, fixing bolts, pins and selected painting including
all necessary works, excavation, formwoks and disposal
of surplus excavated materials as per drawing no.
PWW/21227/INF/SW/DET/09.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 160,630.00

E/ 6/4
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E6 - FENCING & GATE (ALL


PROVISIONAL) (CONT'd)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

FENCING AND GATE AT SEWERAGE TREAMENT


PLANT (CONT'd)

A PVC coated chain link gate overall size 4000mm x no 1 4,500.00 4,500.00
1900mm high, comprising of 63.5mm x mesh B/65mm
B/11G gauge PVC coated chain link including three
strand fixed to gate framing sizes 75mm x x 5.75kg/m
circular hollow section, infill with 4 nos of 60mm diameter
x 5.55 kg/m circular hollow section inner framing, 25mm
diameter mild steel slide bar with clasp and heavy duty
lock, 25mm diameter x 300mm long barrel bolt, two nos
of 115mm plate x 5.75 kg/m circular hollow section gate
post bedded in grade 20 mass concrete stump sizes
450mm x 450mm x 750mm deep complete with all
requisite cutting, jointing, welding, fixing bolts, pins and
selected painting including all necessary works,
excavation, formwoks and disposal of surplus excavated
materialsas per drawing no.
PWW/21227/INF/SW/DET/09.

ELEVATED WATER TANK FENCING AND GATE

B BRC wire mesh panel fencing 2100mm high, comprising m 68 300.00 20,400.00
of 6mm diameter BRC wire mesh fence panel, U- clip at
650mm cemtre with bolt and nut, top and bottom roll
weld fence panel, 150mm x 150mm reinforced concrete
post with mild steel reinforcement bar 4 nos x 10mm
diameter as main bar, 6mm diameter links at 100mm
centres embedded in concrete base sizes 400mm x
400mm x 600mm depth, 150mm x 200mm concrete kerb
complete with all requisite cutting, jointing, welding, fixing
bolts, pins and including all necessary works, excavation,
formwoks and disposal of surplus excavated materials as
per drawing no. PWW/21227/INF/EWT/LP/04.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 24,900.00

E/ 6/5
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

BILL NO. E6 - FENCING & GATE (ALL PROVISIONAL)


(CONT'd)

ELEVATED WATER TANK FENCING AND GATE


(CONT'd)

A BRC wire mesh gate overall size 4000mm x 2100mm no 1 5,000.00 5,000.00
high, comprising of 6mm diameter BRC wire mesh fence
panel, U- clip at 650mm cemtre with bolt and nut, top and
bottom roll weld fence panel, 2 nos of 150mm x 150mm
reinforced concrete post with mild steel reinforcement bar
4 nos x 10mm diameter as main bar, 6mm diameter links
at 100mm centres embedded in concrete base sizes
400mm x 400mm x 600mm depth, 150mm x 200mm
concrete kerb, lockset, hinges complete with all requisite
cutting, jointing, welding, fixing bolts, pins and including
all necessary works, excavation, formwoks and disposal
of surplus excavated materials as per drawing no.
PWW/21227/INF/EWT/LP/04.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 5,000.00

E/ 6/6
BILL E : EXTERNAL WORKS

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

Item Description Unit Qty Rate Amount

BILL NO. E6 - FENCING & GATE (ALL PROVISIONAL)


(CONT'd)

COLLECTION PAGE

PAGE E/6/1 6,130.10

PAGE E/6/2 5,938.60

PAGE E/6/3 4,025.00

PAGE E/6/4 160,630.00

PAGE E/6/5 24,900.00

PAGE E/6/6 5,000.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 206,623.70

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

E/6/7
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E7 - COVERED WALKWAY (ALL


PROVISIONAL)

Work Below Lowest Floor Finish

Note: All excavation are measured from formation


level, unless otherwise stated.

Excavate surface to reduce level from formation level

A Average 650mm deep m3 135 5.00 675.00

Anti termite treatment againts subterranean termite


using termitticide chemical soil treatment after laying
of hardcore and prior to concreting and approved by
ministry of health including providing two (2) years
written guarantee

B Approved spray anti termiticide with 0.5% EC at 5 litre m2 95 2.50 237.50


per square metre or approved equivalent per
impregnation of soil surfaces as specified to underside of
the raft foundation and other structures as directed by
the S.O's approval

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

C 150mm Thick under raft foundations m2 95 12.00 1,140.00

________________________ - - -
D Selected sand backfill as specified spread and levelled m3 28 35.00 980.00
as described

Lean concrete C12/15 as specified :

E Under raft foundation, not exceeding 100mm thick m3 5 325.00 1,625.00

Vibrated reinforced concrete C32/40 as specified :

F In raft foundation, 100mm - 150mm m3 14 433.00 6,062.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 10,719.50

E/ 7/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E7 - COVERED WALKWAY (ALL


PROVISIONAL) (CONT'd)

Vibrated reinforced concrete C32/40 as specified :


(CONT'd)

A EXTRA OVER for forming thickening to underside of raft m 78 50.00 3,900.00


foundations for an additional depth of 300mm and an
average width of 400mm including all necessary
excavation, sawn formwork, sand blinding and hand
packing hardcore to slope on one side

B EXTRA OVER for forming thickening to underside of raft m 16 50.00 800.00


foundations for an additional depth of 300mm and an
average width of 500mm including all necessary
excavation, sawn formwork, sand blinding and hand
packing hardcore to slope on one side

High tensile steel bar reinforcement to MS 146 as


described in :

In raft foundation

C 10mm Diameter kg 978 4.10 4,009.80

In thickening

D 10mm Diameter kg 302 4.10 1,238.20

E 16mm Diameter kg 344 4.10 1,410.40

F 25mm Diameter kg 840 4.10 3,444.00

Sawn formwork as specified :-

G To edges and faces of raft foundation, not exceeding m 90 11.00 990.00


250mm high

Frame

Mild steel as described :-

H 100mm x 100mm x 4mm thick x 11.84kg/m rectangular kg 1,175 10.00 11,750.00


hollow section as column

J 100mm x 50mm x 3mm thick x 6.66kg/m rectangular kg 736 10.00 7,360.00


hollow section as roof beam

K 220mm x 220mm x 10mm thick mild steel plate no 32 200.00 6,400.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 41,302.40

E/ 7/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E7 - COVERED WALKWAY (ALL


PROVISIONAL) (CONT'd)

Frame (CONT'd)

A M20 x 200mm long anchor bolt complete with head no 128 15.00 1,920.00
including drilling through mild steel plate

B Prepare and apply one coat alkyd-based rust preventing tonne 2 1,100.00 2,200.00
primer undercoat and two finishing coats of 'Quick Drying
Micaceous Iron Oxide F353 - Line to structural steel

ROOF

PREFABRICATED COLD FORMED STEEL ROOF


TRUSS SYSTEM

Notes:
Notwithstanding the Standard Method Measurement 2nd
edition, this item is measured in Square Metre (M2)

Steel roof trusses components shall be manufactured


and assembled only by truss fabricators accredited by
system provider.
The design, supply, delivery and erection of the trusses
shall be in accordance with JKR Standard Specifications
for Prefabricated Cold Formed Steel Roof Trusses.

The Contractor is to submit together with his Tender


shop drawing duly endorsed by a Professional Engineer
and all other documentation as mentioned in the JKR
Standard Specifications for Prefabricated Cold Formed
Steel Roof Trusses.
The Contractor is to seek the S.O's approval prior to any
work on the roof structure.
(End of Notes)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 4,120.00

E/ 7/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E7 - COVERED WALKWAY (ALL


PROVISIONAL) (CONT'd)

ROOF (CONT'd)

Design, fabricate, supply, deliver, erect and install


complete in position prefabricated cold formed steel
roof trusses as described and providing ten (10)
years warranty :-

A Roof trusses system including hoisting and fixing into m2 177 100.00 17,700.00
position 3.10m high from ground level

Roof Covering

An approved concrete roof tiles laid to pitch roof on


Prefabricated Cold Formed Steel Roof Trusses all in
accordance with the manufacturer's instruction
(measured nett-no allowance made for laps)

B Roof covering laid to 25 degree pitch m2 177 40.00 7,080.00

C Ridge tile to match roof covering bedded, jointed and m 43 30.00 1,290.00
pointed in cement mortar grouting

D 3 way apex to match roof covering bedded, jointed and no 1 35.00 35.00
pointed in cement mortar grouting

E 4 way apex to match roof covering bedded, jointed and no 1 45.00 45.00
pointed in cement mortar grouting

Wrot pressure treated S.G.1 & S.G.2 timber as


described :

F 200mm x 20mm Thick fascia board m 83 35.00 2,905.00

G 200mm x 20mm Thick barge board m 20 35.00 700.00

Knot, prime, stop and paint one undercoat and two


finishing coats of gloss enamel paint with Eco
Labelling Certificate from SIRIM as specified on
woodworks and providing eight (8) years warranty :-

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

H To surfaces of fascia board m2 36 10.00 360.00

J To surfaces of barge board m2 9 10.00 90.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 30,205.00

E/ 7/4
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E7 - COVERED WALKWAY (ALL


PROVISIONAL) (CONT'd)

Rain Water Down Pipe

Unplasticiser polynvinyl chloride (UPVC) rainwater


down pipes to B.S 3505 class 'C' and fitting including
jointing with solvent cement in accordance with the
manufacturer's instruction

A 150mm wide UPVC gutter complete with bracket at m 83 50.00 4,150.00


600mm centres, accessories and fix to fascia board to
Architect's approval

B 100mm Diameter UPVC rainwater down pipe fixed to m 41 35.00 1,435.00


column and wall

C EXTRA FOR 90 degree bend no 12 20.00 240.00

D EXTRA FOR 45 degree bend no 24 20.00 480.00

E EXTRA FOR 100mm diameter dome shape grating. no 12 50.00 600.00

F 1o0mm Diameter UPVC rainwater down pipe laid under m 13 35.00 455.00
apron slab

Floor Finishes

Cement and sand (1:3) rendering, trowelled hard and


smooth as specified:

G 25mm thick paving m2 95 18.00 1,710.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 9,070.00

E/ 7/5
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E7 - COVERED WALKWAY (ALL


PROVISIONAL) (CONT'd)

COLLECTION PAGE

PAGE E/7/1 10,719.50

PAGE E/7/2 41,302.40

PAGE E/7/3 4,120.00

PAGE E/7/4 30,205.00

PAGE E/7/5 9,070.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 95,416.90

E/7/6
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E8 - FLAG POST (ALL PROVISIONAL)

FLAG POST

Excavate, get out, part return, fill in and ram and


deposit and spread in making up level where
directed within the site and remainder load and cart
away from site

A Excavate pit for flag post base maximum depth not m3 1 6.00 6.00
exceeding 1.00m deep

Mass concrete Grade 20 as specified :

B In pad footing m3 1 350.00 350.00

C In slab m3 1 350.00 350.00

Sawn Formwork as specified :-

D To edges and faces of pad footing, 500mm - 1.00m high m 5 28.00 140.00

E To edge and faces of concrete not exceeding 250mm m 8 7.00 56.00


high

Supply and fix 300mm x 300mm approved polished


homogeneous tiles with colour and pattern and
approved by the S.O, bedded and jointed in cement
mortar (1:3) as specified on and including 20mm
thick cement and sand as specified screed and
pointed with matching coloured cement:-

F Finish to slab m2 4 75.00 300.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

G Finish to drop 50mm m 8 4.00 32.00

Stainless steel pipe as specified :-

H 75mm Diameter x 3.00m long stainless steel post no 9 2,000.00 18,000.00


complete with and including 6mm diameter stainless
steel dowel welded to post, 6mm thick x 300mm diameter
stainless steel base plate , 4 nos of R19mm diameter
bolt and nut drilled through concrete footing all as per
drawing no. KN/ALA/646/07/2021/33.

J 50mm Diameter x 3.0m long stainless steel post with and no 9 1,000.00 9,000.00
including all necessary accessories all as per drawing no.
KN/ALA/646/07/2021/33.

K Extra for 75mm - 50mm reducing piece no 3 65.00 195.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 28,429.00

E/ 8/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E8 - FLAG POST (ALL PROVISIONAL)


(CONT'd)

FLAG POST (CONT'd)

A Supply and fix 6mm diameter 'nylon' rope m 10 6.50 65.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 65.00

E/ 8/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E8 - FLAG POST (ALL PROVISIONAL)


(CONT'd)

COLLECTION PAGE

PAGE E/8/1 28,429.00

PAGE E/8/2 65.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Summary 28,494.00

E/8/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E9 - RAINWATER HARVESTING SYSTEM


(ALL PROVISIONAL)

RAIN WATER HARVESTING SYSTEM

A Construct and complete rainwater harvesting system no 1 10,000.00 10,000.00


constructed of reinforced concrete base, storage tank
1,200/265 gallon capacity, first flush diverter, filter, piping
with and including all necessary excavation, concrete
work, formwork, reinforcement and necessary fittings as
per engineer's approval and drawing no.
PWW/21227/INF/MJ/RD/DET/16.

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 10,000.00

E/ 9/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E9 - RAINWATER HARVESTING SYSTEM


(ALL PROVISIONAL) (cont'd)

COLLECTION PAGE

PAGE E/9/1 10,000.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 10,000.00

E/9/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL


PROVISIONAL)

ACCELERATION AND DECELERATION (AC/DC)

New Road

A Excavate oversite for road formation average depth m2 2,305 5.00 11,525.00
760mm deep, commencing from platform level, get out,
part return, fill in and ram and deposit and spread in
making up level where directed and remainder, load and
cart away from site.

B Grade to road formation level to gradient and cross falls m2 2,305 2.00 4,610.00
and roll with 8 tonne roller

C 150mm thick granular sub-base of hard clean sand m2 2,305 7.50 17,287.50
spread and levelled and well rolled and compacted to fall
and chamber with 8 tonne roller toreceive crusher run

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

D 300mm Thick (consolidated) crusher run base course m2 2,305 30.00 69,150.00
laid in two layers of 100mm thick per layer with all
interstices filled with graded granite including well
consolidating, watering and blinding surface and rolling
with 8 ton roller

E Approved bituminous prime coat as specified to road and m2 1,809 2.00 3,618.00
carparks spread at rate 8 yard super per gallon

F 60mm Thick asphaltic premix binder course (AC28) as m2 1,809 36.00 65,124.00
specified spread on finished surfaces to receive premix
surfacing (measured separately).

G Approved bituminous tack coat as specified to road and m2 1,809 2.00 3,618.00
carparks spread at rate 10 yard super per gallon

H 50mm Thick (consolidated) premix as specified wearing m2 1,809 31.00 56,079.00


course (AC14) rolled with 8 tonne roller.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 231,011.50

E/ 10/1
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL


PROVISIONAL) (CONT'd)

Road Resurface (CONT'd)

A Scrap off existing road premix by means of mechanical m2 3,686 20.00 73,720.00
scrapper with and including grubbing out asphaltic
concrete binder course and asphaltic concrete wearing
course to a total thickness of 40mm thick to receive new
premix surfacing and remove from site

B Approved bituminous tack coat as specified to road and m2 3,686 2.00 7,372.00
carparks spread at rate 10 yard super per gallon

C 50mm Thick (consolidated) premix as specified wearing m2 3,686 31.00 114,266.00


course (AC 14) rolled with 8 tonne roller.

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

_________________

D Allow for testing as specified in conjunction with L.S 5,000.00


roadworks

Road Marking

Prepare and apply 2mm thick of thermoplastic road


paint on premix road and/or pavement to form :-

E 100mm Wide continuity line (Type 1) m 183 4.00 732.00

F 100mm Wide centre line (Type 4) m 147 4.00 588.00

G 150mm Wide edge line (Type 6) m 1,400 6.00 8,400.00

H 200mm Wide give-way line (type 2) m 194 8.00 1,552.00

J 300mm Wide stop line (Type 7) m 10 12.00 120.00

K 100mm Wide double line (Type 10) m 166 8.00 1,328.00

L 825mm Wide (extreme) single directional arrow sign for no 17 500.00 8,500.00
straight traffic overall length 3000mm.

M 1945m Wide (extreme) straight and corner directional no 2 700.00 1,400.00


arrow sign overall length 3000mm

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 222,978.00

E/ 10/2
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL


PROVISIONAL) (CONT'd)

Road Marking (CONT'd)

Prepare and apply 2mm thick of thermoplastic road


paint on premix road and/or pavement to form :-
(CONT'd)

A 1120mm Wide (extreme) branch directional arrow sign no 1 700.00 700.00


overall length 3000mm

B 1120mm Wide (extreme) corner directional arrow sign no 9 500.00 4,500.00


overall length 1500mm

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

C 300mm wide chevron hatching at 600mm centres m2 396 40.00 15,840.00

D 300mm wide island hatching at 600mm centres m2 106 40.00 4,240.00

E Rumble strip line m 88 15.00 1,320.00

Delineators

F Raised Reflective Pavement Markers as per specification no 138 50.00 6,900.00

Road Signage

Supply and install the following road signboard


made of reflectorised sticker high intensity in
accordance to jabatan kerja raya (JKR)'s standard
including all excavation, post, footing and painting
works for post complete with other associated
accessories

G 'BERHENTI' sign (RP.1) no 1 500.00 500.00

H Road junction on the left sign (WD 27c) no 1 500.00 500.00

J Road junction on the right sign (WD 27b) no 1 500.00 500.00

K 'AWAS' sign (WD 17) no 2 500.00 1,000.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 36,000.00

E/ 10/3
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL


PROVISIONAL) (CONT'd)

Road Signage (CONT'd)

A Remove and relocate existing electric pole with and nos 7 5,000.00 35,000.00
including cabling and store to area to be determine by
S.O including load and cart away all debris from site to
Contractor's own dumping and making good all works
disturbed.

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

SURFACE WATER DRAINAGE

THE FOLLOWING IN 600MM WIDE (INTERNAL


DIMENSION) PRECAST CONCRETE U-DRAIN WITH
COVER SLAB TYPE D2

Excavate trench for drainage commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site.

B 740mm width drain, maximum depth not exceeding m3 52 5.00 260.00


1.00m deep

C 740mm width drain, maximum depth not exceeding m3 235 10.00 2,350.00
2.00m deep

Hardcore consisting of crusher run as described


spread levelled, well consolidated, watered and
blinded with sand topping, well rolled in and
finished.

D 300mm Thick under precast U-drain m2 243 30.00 7,290.00

Lean concrete Grade 15 as specified :

E Under drain, not exceeding 100mm thick m3 12 325.00 3,900.00

Brickwork in cement and sand brick in cement and


sand (1:6) mortar with an approved plasticiser as
specified and reinforced with and including brick
reinforcement at every fourth course.

F 225mm thick wall m2 268 90.00 24,120.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 72,920.00

E/ 10/4
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL


PROVISIONAL) (CONT'd)

Cement and sand (1:6) with an approved plasticier


plastering finished with straight- edge wood float as
specified (CONT'd)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

A 20mm Thick to internal surfaces of wall, sides and top of m2 383 22.00 8,426.00
wall.

Reinforced vibrated precast concrete Grade 30 as


described including all moulds, hoisting and setting
in cement mortar (1:3) :-

B 600mm long x 740mm wide x 125mm thick drain cover no 549 82.00 45,018.00
finished fair on exposed surfaces and reinforced with and
including reinforcement bar of 10mm diameter at 100mm
centre high tensile, 6mm diameter at 200mm centre mild
steel complete with concrete work, rendering, formworks
and all necessary works.

___________________________
C 600mm wide x 600mm high precast concrete U-drain m 329 170.00 55,930.00
channel laid to fall embedded on crusher run (measure
separately)

(End of 600mm Wide (Internal) Precast Concrete U-Drain


With Cover Slab (Type D2)
WING WALL

D Construct and complete wing wall overall size 7,425mm x no 1 2,575.00 2,575.00
230mm wide x 900mm high constructed of 200mm thick
crusher run, 50mm thick lean concrete, 200 thick
reinforced concrete base with double layer BRC A8,
plastering with and including excavation works and all
necessary to engineer approval and drawing no.
PWW/21227/INF/RD/DE/01 & 05.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 111,949.00

E/ 10/5
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL


PROVISIONAL) (CONT'd)

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

WATER RETICULATION

Excavate trench for large pipe commencing from


platform level, get out part return, filling and ram and
remove surplus excavated material from site

A To receive 180mm diameter pipe (incoming) not m 400 5.00 2,000.00


exceeding 2.00m

Supply and lay the following in HDPE pipe (PN 16)


and fitting with electrofusion jointing as specification
:-

B 180mm Diameter (O.D) pipe (incoming) laid and jointed m 400 140.00 56,000.00
in trench

________________
C Selected fine sand backfill as specified spread and m3 467 40.00 18,680.00
levelled in trench

Concrete grade 25 as specified:-

D Thrust block as specified for pipe overall size 455mm x no 34 46.00 1,564.00
550mm x 200mm high and including all necessary
formwork and excavation

Testing

E On completion of the installation of the water supply item 1 3,500.00 3,500.00


pipelines, test all pipings, fittings, hydrants, etc. for water
tightness, make good all defects and leave everything in
perfect working order to the entire satisfaction of the
Architect / S.O. and Local Authorities

F Allow for flushing and disinfecting the tested pipelines item 1 3,000.00 3,000.00
with chlorine bearing water to the satisfaction of the
Architect / S.O. and Local Authorities

G Allow for connection to existing 150mm diameter AKSB item 2 3,000.00 6,000.00
pipe.

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 90,744.00

E/ 10/6
BILL E : EXTERNAL WORKS

Item Description Unit Qty Rate Amount

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL


PROVISIONAL) (CONT'd)

COLLECTION PAGE

PAGE E/10/1 231,011.50

PAGE E/10/2 222,978.00

PAGE E/10/3 36,000.00

PAGE E/10/4 72,920.00

PAGE E/10/5 111,949.00

PAGE E/10/6 90,744.00

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Collection 765,602.50

E/10/7
BILL E : EXTERNAL WORKS

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

Item Description Page Amount

SUMMARY

BILL NO. E1 - SITE PREPARATION, EARTHWORKS & OTHER E/1/7 2,736,899.00


TEMPORARY WORKS (ALL PROVISIONAL)

BILL NO. E2 - ROADWORKS, CARPARKS & HARDSTANDING (ALL E/2/5 570,040.00


PROVISIONAL)

BILL NO. E3 - SURFACES WATER DRAINAGE (ALL PROVISIONAL) E/3/15 446,687.00

BILL NO. E4 - WATER RETICULATION, SUCTION TANK AND ELEVATED E/4/27 494,738.90
WATER TANK (ALL PROVISIONAL)

BILL NO. E5 - SEWERAGE RETICULATION AND SEWERAGE E/5/6 240,244.00


TREATMENT SYSTEM (ALL PROVISIONAL)

BILL NO. E6 - FENCING & GATE (ALL PROVISIONAL) E/6/7 206,623.70

BILL NO. E7 - COVERED WALKWAY (ALL PROVISIONAL) E/7/6 95,416.90

BILL NO. E8 - FLAG POST (ALL PROVISIONAL) E/8/3 28,494.00

BILL NO. E9 - RAINWATER HARVESTING SYSTEM (ALL PROVISIONAL) E/9/2 10,000.00

BILL NO. E10 - WORK OUTSIDE BOUNDRY (ALL PROVISIONAL) E/10/7 765,602.50

MAKMAL VETERINAR ZON TIMUR UTARA, CHEKLI KELANTAN To Ringkasan Tender 5,594,746.00

05/08/2024 - 07:05:07
JKR E-Tender | SD210723

E/SUM/1

05/08/2024 - 07:05:07

You might also like