ITEM

DESCRIPTION UNIT QTY


NO

HVAC SYSTEM
1 Package Air Conditioning Unit
Package Air Conditioning Units with refrigerant 410A complete with cooling
coil, volume dampers,pre and bag filters, supply fans, valves, stainless steel
drain pan, concrete base, vibration isolators, supports, flexible connection and
complete with controls and required accessories for proper installation and
operation, all as per specs and drawings.
Ref No. Air Flow [CFM] Capacity Cooling[BTU/H]
1.1 PU-01 8000 330000 No.
2 FANS
2.1 EXHAUST AIR FANS
Installing, connecting, testing and commissioning of in-line exhuast fan with
all accessories, components, devices as per schedules and specifications
complete with earthing, sealant for leakage, labels, connecting with power
cables, power panel and all needed to complete work as per specification &
drawings.
2.1.1 EX.F-01 (Air Flow Rate: 200 CFM) No. 1
2.1.2 EX.F-02 (Air Flow Rate: 150 CFM) No. 4
3 DUCT WORKS
3.1 Duct

Supply, installation connecting, testing and commissioning of galvanized or


black steel or aluminum, or stainless steel materials fabricated, according to
the specifications and drawings including all accessories, complete with-but
3.1.1 not limited to: delivers, stored in good conditions, volume dampers, flexible kg 1,100
connection, splitter linear diffuser boxes, inspection doors, support, hangers,
rods, anchors nuts, bolts, riveting and sealers, sleeves, tags, charts labels,
color code finishing, flow indicator, earthing, see detail drawings.

3.1 Duct Thermal Insulation


Supplying, Installing, and commisioning of thermal insulation for supply and
return air ducts manufactured from fiberglass with aluminum foil to be fixed
by adhesive material, c\w all necessary accessories for proper installation
m2 200
and operation as per drawings and specifications confirming the requirements
of ASHRAE & SMACNA (Insulation 1'' thickness and 24 kg\m3 density for
3.2.1
indoor ducts )
4 AIR DISTRIBUTION
install, connection, balancing and commissioning of grilles, diffusers
complete with-but not limited to straightners, dampers for supply, shutter for
exhuast, plenums, wire mesh, clamps, hangers support and paint and all other
accessories as per specifications and as shown on drawings.
4.1 SUPPLY CEILING DIFFUSER S.C.D.
4.1.1 S.C.D.6"X6" 3
4.1.2 S.C.D.9"X9" 13
4.1.3 S.C.D.12"X12" 12
4.2 RETURN CEILING DIFFUSER R.C.D.
4.2.1 R.A.G.6"X6" 2
4.2.2 R.A.G.9"X9" 13
4.2.3 R.A.G.12"X12" 10
4.3 EXHAUST CEILING DIFFUSER EX.C.D.
4.3.1 EX.A.G.20"X40" 1
Unit Total
Price Amount
L.E L.E

0
0

0
0
0
0

0
0
0