Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SUC

GAS TRANSFER PIPELINE FROM SUC TO LUC/GAS


UNDER GROUND PIPE (DAMAGED OR REMOVED)
PAVED ROAD , WIDTH 7.0 M ,WIDTH 7.0 M
ELECTRIC LINE/1 FROM SUC TO LUC /GAS
ELECTRIC LINE/2 FROM SUC TO LUC /GAS

N
GAS TRANSFER PIPELINE FROM SUC TO LUC/GAS

UNDER GROUND PIPE (DAMAGED OR REMOVED)

PAVED ROAD , WIDTH 7.0 M

ELECTRIC LINE FOM SUC


SUC TO
TO LUC
LUC /GAS

ELECTRIC LINE FOM SUC TO LUC /GAS

10+000
5+000

6+000

7+000

8+000

9+000
LUC/GAS

KEY PLAN (NOT TO SCALE)

ELEVATION
METRESABOVE M.SL

C:\Users\Dell\Desktop\IRAQ MAP\WSCCAY9J4N9CA5TMO0QCA7QVDH4CAYJUWEOCAFQEX2FCAIBHMDLCAKLN6BFCAEUECSCCASOQEPBCA3CFYXYCA2K32FLCAHAVDCWCAGS9SD1CAUHHG1XCA5XGZ5GCAQM398RCAUVCLGRCA2M5QB1CAOF3Q1X.jpg

50
40
30
20
KILOMETRES
SUBA AND LUHAIS OIL FIELDS
SURVEY REFERENCE ( EXISTING MARKER )

PARTIAL DISTANCES (M) 5000

10+000
5+000
5+056

5+181

5+306

5+431

5+556

5+681

5+806

5+931

6+056

6+181

6+306

6+431

6+556

6+681

6+806

6+931

7+056

7+181

7+306

7+431

7+556

7+681

7+806

7+931

8+056

8+181

8+306

8+431

8+531

8+681

8+806

8+931

9+056

9+181

9+306

9+431

9+556

9+681

9+806

9+931
PROGRESSIVE DISTANCES REFERRED TO PIPLINE
STARTING POINT AT

DISTANCE BETWEEN CENTER LINE OF


ELECTRIC LINE DISTANCE BETWEEN LINE AND ANOTHER IS 30.0 M
34.52
34.76

35.19

35.29

35.52

35.70

35.97

36.11

36.27

36.45

36.73

36.94

37.21

37.60

37.89

38.12

38.24

38.44

38.78

39.13

39.47

39.81

40.11

40.33

40.47

40.88

41.13

41.36

41.78

42.10

42.39

42.85

43.35

43.56

43.99

44.41

44.74

45.10

45.47

45.70

45.96
46.03
GROUND ELEVATIONS

PIPE LINE BOTTOM ELEVATIONS

DIRECTION CHANGES ( DEGREES )

SOIL NATURE POORLY GRADED SAND WITH SILT AND WITH SALTS
GROUND FEATURE DESERT AREA
PIPE LINE DIA ( ) X THICKNESS mm LENGTH M

FITTING & SPECIAL PARTS

SOIL RESISTIVITY IN OHM-METRS

CATHODIC PROTECTION

PIPE LINE MARKERS

PIPE LINE PROTECTION

ANCILLARY WORKS

LEGEND SOC
CLIENT:.........................
NOTE
SL 01 SL 02 SL 03 SL 04 SL 05 SUBA AND LUHAIS OIL FIELDS
PROJECT :...........................................
PIPELINE MARKER
- ALL COORDINATES WAS TAKEN BY WGS 84 CATHODIC PROTECTION TEST POINT SEE TEST POINTS SCHEDULE ( -EK-) BASSRA
BAGHDAD IRAQ SITE :..................................
CATHODIC PROTECTION STATION SEE CATHODIC PROTECTION KEY DIAGRAM ( - EK - )
- MINIMUM DISTANCE BETWEEN ELECTRIC LINE AND PIPELINE IS 15M LEAN CNOCRETE WEIGHTING
SCOP STATE COMPANY FOR OIL PROJECTS
PROPOSED P/L SL 06
DOCUMENT TITLE :
O/G P/L ROUTE MAP AND PROFILE FOR ELECTRIC LINE/1 (33kV)
ERTH ROAD FROM SUC TO LUC/GAS FROM DIST. KM 5+000 TO KM 10+000
PAVED ROAD , WIDTH 7.0 M 7.0 M
ELECT.LINE DRAWN ENG. THIA ENG. ARRAF SCALE H:1/ 10 000
1000
DATE: FEB, 2011
KM SURVEYED
V:1/
CANAL ENG. HADI ENG. OMER
PROJECT No. 2084
CHECKED DR.MAHDI
APPROVED DRW. No. 00-00-10- SL 02
SCOP
APPROVED REV.No : B SHEET.No : 2/6

You might also like