SalvageSale Asset Audit, Inventory & Testing Report

Asset Description ARISTA 7808 CH SERIES SYSTEM


Asset Serial Number HNN23156219
Asset Model Number DCS-7808

Activity Date & Time Performed Resource Initials


Received asset November ‘23 JS
Started required picture listing November 6th JS
Completed testing November 7th JS
Completed component level inventory November 8 th
JS
Posted all related information to the tracking spreadsheet November 10th RC

Standard Parts Summary


Component Level Inventory
Qty Component Description
1 ARISTA DCS-7808 16RU Chassis (leans left to right)
2 7800-SUP1A Supervisor Cards
6 7808R3-FM FABRIC MODULE (FM) Fan modules
6 7800R3-48 CQ-LC - not reinstalled into system because of damage
8 PWR-D1-3041-AC-BLUE Power Supplies (1 damaged handle)

Software Summary: N/A

Material and Misc Summary: 16 x AC Power cords

Diagnostic Summary: After connecting a console cable to the supervisor in slot 1 and adding power I was
Please document diagnostic steps able to obtain the boot sequence of the system (see boot sequence,doc)
taken as well as diagnostic tools The system reports as having no startup config found.
used to access asset: I was able to log into the system as admin (no password required) and perform the
following commands on the system and installed components.

NOTE: The fan module in slot 6 does not report as installed. It was moved to slot 3
(serial number 619) to show that it works and that slot 6 could be the issue. The
evidence of this can be found on the show inventory 2.doc.
NOTE: The Line Cards do not show as being installed in the system. They do not
have any lights on the units to show they are working when the system is powered
on.

NOTE: the 8 x PSU’s do not report in the show inventory command, but they are all
installed, and they do all work. The PSUs were removed and replaced in various
slots to prove this.

Cosmetic Summary: The pallet box has a hole in the top of it.
Please document cosmetic The pallet box corner staples have come apart.
condition of asset. There is a large black scuff mark on the side of the pallet box.
Include exterior and interior
summary: One the same side there are a couple of dent marks in the box.
The chassis is badly damaged. It leans from left to right.
Everything installed in the chassis is also twisted from left to right.
The system powers on successfully.
There are 2 PSU blanks stuck at the wrong angle and cannot be removed.

Title: SalvageSale Asset Audit, Inventory & Testing Report | File Name: SalvageSale Asset Audit Denver.doc | Author: Jonathan Stopp

Page 1 | Date: 11/14/2023


SalvageSale Asset Audit, Inventory & Testing Report

PWR-D1-3041-AC-BLUE
The PSU in slot 3 is damaged. It can be removed and replaced. The remaining
PSUs are undamaged. They can be removed and replaced with out issue.

7808R3-FM (removed and reinstalled after the 7800R3-48 CQ-LC were


removed)
All 6 x 7808R3-FM were removed without issue despite the chassis damage. The
fan modules all have twisted connectors. (see photo named fan modules).

7800R3-48 CQ-LC x 6: (removed from system but NOT REINSTALLED)


Serial Number SGD22483998 is twisted/warped. It leans from left to right. Half of
the connector pins are stuck inside the chassis still; they are no longer connected to
the 7800R3-48 CQ-LC line card. (they have been carefully removed from the
chassis).

Serial Number SGD2326037K is twisted/warped. This includes the connector pins in


the rear of the board. One of the connector pins shows clear signs of being broken.

Serial Number SGD22443069 is twisted/warped. This includes the connector pins in


the rear of the board. One of the connector pins shows clear signs of being broken.

Serial Number SGD22443069 is twisted/warped. This includes the connector pins in


the rear of the board. One of the middle connectors shows more physical damage
and breaking away from the system board than the rest do. One of the end
connectors shows signs it is splitting into two and will fail like 3 of the connectors
have on Serial SGD22483998.

Serial Number SGD2322021B is twisted/warped. This includes the connector pins in


the rear of the board. Two of the connectors are breaking apart from the system
board.

Serial Number GD23220218 is twisted/warped. This includes the connector pins in


the rear of the board.

Serial Number SGD22443022 is twisted/warped. This includes the connector pins in


the rear of the board. This module has a damaged frame under one of the
connectors. One of the connector pins has split into two. Half of the broken
connector remained connected inside the chassis once the line card was removed.

7800-SUP1A
These units are undamaged. They can be removed without issue
Receiving & Storage Description: Covenco Inc, Denver, 80239
Packaging, Weights 1 x pallet @ 750lbs
& Descriptions 51 x 24 x 38 (H) inches
Country of Manufacture USA