SERVICE BULLETIN

OXYGEN - PASSENGER OXYGEN SYSTEM MASK


IN-LINE FLOW INDICATOR REPLACEMENT

I. Planning Information

A. Effectivity

This Service Bulletin applies to all aircraft that use passenger oxygen mask part numbers 174080-XX,
174085-XX, 174095-XX, 174097-XX, 174098-XX, and 174006-XX that were manufactured on or after
January 1, 2002 and before March 1, 2006. This Service Bulletin applies to spare masks in stores, as
well as those installed on aircraft. The following lists show the effective mask by part number series.

174080 Series

174080-AG 174080-PK 174080-58 174080-98 174080-466


174080-AH 174080-05 174080-59 174080-101 174080-467
174080-AL 174080-1A 174080-60 174080-106 174080-468
174080-AM 174080-1C 174080-61 174080-107 174080-469
174080-AN 174080-1H 174080-62 174080-113 174080-470
174080-AQ 174080-16 174080-63 174080-116 174080-471
174080-BQ 174080-17 174080-64 174080-117 174080-472
174080-BR 174080-26 174080-66 174080-141 174080-473
174080-BS 174080-27 174080-67 174080-142 174080-474
174080-BT 174080-31 174080-68 174080-143 174080-475
174080-BU 174080-37 174080-69 174080-144 174080-476
174080-CC 174080-39 174080-72 174080-145 174080-477
174080-CM 174080-49 174080-73 174080-152 174080-478
174080-CN 174080-50 174080-74 174080-161 174080-479
174080-CO 174080-51 174080-75 174080-162 174080-480
174080-CQ 174080-52 174080-76 174080-163 174080-481
174080-DJ 174080-53 174080-87 174080-164 174080-482
174080-DS 174080-54 174080-93 174080-166 174080-483
174080-OU 174080-55 174080-95 174080-180 174080-484
174080-PB 174080-56 174080-96 174080-184 174080-485
174080-PJ 174080-57 174080-97 174080-193 174080-486

The information disclosed herein was originated by and is the property of B/E Aerospace, Inc., and except for
rights expressly granted to the U.S. Government, B/E Aerospace, Inc. reserves all patent, proprietary, design, use,
manufacturing, and reproduction rights thereto.

06 Sep 2010 174080-35-04


Rev 000 Page 1 of 8
B/E AEROSPACE
Service Bulletin

174085 Series

174085-1B 174085-60 174085-94


174085-1E 174085-73 174085-96
174085-43 174085-74 174085-97
174085-56 174085-76 174085-98
174085-59 174085-87

174095 Series

174095-M1 174095-28 174095-133


174095-M4 174095-29 174095-134
174095-MM 174095-51 174095-135
174095-1E 174095-52 174095-136
174095-10 174095-54 174095-137
174095-11 174095-57 174095-138
174095-13 174095-58 174095-139
174095-14 174095-61 174095-140
174095-15 174095-62 174095-141
174095-16 174095-73 174095-142
174095-17 174095-74 174095-143
174095-18 174095-76 174095-144
174095-19 174095-87 174095-145
174095-20 174095-96 174095-770
174095-21 174095-97 174095-771
174095-22 174095-98 174095-772
174095-23 174095-129 174095-773
174095-25 174095-130 174095-774
174095-26 174095-131 174095-775
174095-27 174095-132 174095-776

174097 Series

174097-29 174097-31
174097-30 174097-40

174098 Series

174098-01 174098-04
174098-02 174098-05
174098-03 174098-06

174006 Series

174006-31
174006-33

B. Reason

Some existing flow indicators are vulnerable to fracturing which causes parts of the indicator to
separate. If this occurs, the oxygen cannot flow to the user of the mask when needed during an
emergency.

06 Sep 2010 174080-35-04


Rev 000 Page 2 of 8
B/E AEROSPACE
Service Bulletin
C. Description

This Service Bulletin describes the mandatory replacement of flow indicator part number 118023-02
with the improved flow indicator part number 118023-12. The improved flow indicator can be identified
by the green marking (refer to Figure 1).

The operator may purchase a replacement mask with the improved flow indicator installed as an
alternative to performing the modification covered by this Service Bulletin.

Figure 1
Flow Indicators

D. Compliance

Performance of this Service Bulletin is mandatory.

E. Approval

This Service Bulletin has been reviewed by the FAA.

F. Manpower

Assuming access has been obtained to the unit, the following is an estimate to accomplish the
modification:

Verification: .6 min.
Disassembly: .3 min.
Assembly: 1.2 min.
Testing: .4 min.
Cleaning: .5 min.

Total Modification: 3.0 min.

G. Material - Price and Availability

(1) Modification requires the following:

Quantity Part Number Name


1 118023-12 Flow Indicator

06 Sep 2010 174080-35-04


Rev 000 Page 3 of 8
B/E AEROSPACE
Service Bulletin
(2) Material may be obtained from:

B/E Aerospace, Inc.


Commercial Aircraft Products Group
10800 Pflumm Road
Lenexa, KS 66215
TEL: (913) 338-9800
FAX: (913) 469-8419

(3) Delivery determined upon request.

H. Tooling - Price and Availability

Tubing Stretcher Tool part number 997300-00, available from B/E Aerospace, Lenexa, KS (refer to
Figure 2).

I. Weight and Balance

This modification will not affect the weight or balance.

J. Electrical Load Data

This modification will not affect electrical load data.

K. Other Publications Affected

Part Number CMM Number Dated


174080-XX 35-20-96 2003/06/12
174085-XX 35-24-02 2010/06/25
174095-1X 35-24-03 2009/12/01
174095-77X 35-11-19 2010/01/08
174095-XX and 174097-XX 35-24-04 2000/11/01

II. Accomplishment Instructions

A. Verification

(1) Make sure the part number shown on the mask data label appears in one of the lists of effective
part numbers. If the part number is not listed, no further action is required (refer to Figure 3 for
location of data label).

(2) Make sure the date of manufacture shown on the mask data label is on or after January 1, 2002
and before March 1, 2006. If the date is outside this range, no further action is required (refer to
Figure 3 for location of data label).

(3) Make sure the marking, "FLOW", on the flow indicator is in black and the letter "W" does not appear
on the right side of the mask data label (approximate location is shown in Figure 3). In the event the
marking on the flow indicator is in green and the letter "W" is on the right side of the data label, flow
indicator replacement has already been implemented. No further action is required.

06 Sep 2010 174080-35-04


Rev 000 Page 4 of 8
B/E AEROSPACE
Service Bulletin
B. Disassembly (refer to Figure 3)

WARNING: THE USE OF OIL AND OTHER PETROLEUM BASE LUBRICANTS ON OXYGEN
EQUIPMENT WILL CREATE A DANGEROUS FIRE HAZARD.

CAUTION: THE WORK AREA MUST BE CLEAN AND FREE OF HYDROCARBON RESIDUE, OIL,
OR OTHER PETROLEUM BASE LUBRICANTS.

CAUTION: ALL INSTRUMENTS, TOOLS, FIXTURES, TEST EQUIPMENT, AND OTHER


MATERIALS WHICH COME INTO CONTACT EITHER DIRECTLY OR INDIRECTLY
WITH THE UNIT OR ITS PARTS SHOULD BE CLEAN AND FREE OF HYDROCARBON
RESIDUE, OIL, OR OTHER PETROLEUM BASE LUBRICANTS.

WARNING: BE CAREFUL TO CUT OFF ONLY A MINIMUM AMOUNT OF TUBING (1, 4). CUT OFF
NO MORE THAN TWO INCHES OF TUBING FROM BOTH TUBES (1, 4) TOGETHER.

(1) Cut the supply tube (4) loose from the flow indicator (2).

(2) Cut the flow indicator (2) loose from the mask bag assembly tube (1).

NOTE: Cut each tube (1, 4) square so that the end is flat and perpendicular to the axis of the tube
(1, 4).

C. Assembly (refer to Figure 3 unless otherwise stated)

WARNING: THE USE OF OIL AND OTHER PETROLEUM BASE LUBRICANTS ON OXYGEN
EQUIPMENT WILL CREATE A DANGEROUS FIRE HAZARD.

CAUTION: THE WORK AREA MUST BE CLEAN AND FREE OF HYDROCARBON RESIDUE, OIL,
OR OTHER PETROLEUM BASE LUBRICANTS.

CAUTION: ALL INSTRUMENTS, TOOLS, FIXTURES, TEST EQUIPMENT, AND OTHER


MATERIALS WHICH COME INTO CONTACT EITHER DIRECTLY OR INDIRECTLY
WITH THE UNIT OR ITS PARTS SHOULD BE CLEAN AND FREE OF HYDROCARBON
RESIDUE, OIL, OR OTHER PETROLEUM BASE LUBRICANTS.

WARNING: THE NEW FLOW INDICATOR (3) MUST BE INSTALLED SO THAT THE FLOW
DIRECTION IS FROM THE SUPPLY TUBE (4) TOWARD THE MASK BAG
ASSEMBLY TUBE (1). THE ARROW ON THE FLOW INDICATOR (3) SHOULD POINT
TOWARDS THE BAG. IF THE NEW FLOW INDICATOR (3) IS INSTALLED
BACKWARDS, THE FLOW INDICATOR WILL NOT SHOW WHEN OXYGEN FLOWS
TO THE MASK.

CAUTION: THE SUPPLY TUBE (4) AND THE MASK BAG ASSEMBLY TUBE (1) ENDS SHOULD
ALWAYS BE FULLY INSTALLED ON THE FLOW INDICATOR (3) UP TO THE
SHOULDER OF THE FLOW INDICATOR.

CAUTION: THE TUBING STRETCHER TOOL PART NUMBER 997300-00 MUST BE SECURED
TO A BENCH TOP BEFORE USE (REFER TO FIGURE 2).

(1) Use the Tubing Stretcher Tool part number 997300-00 (refer to Figure 2) to expand the inside
diameter of the end of the mask bag assembly tube (1).

06 Sep 2010 174080-35-04


Rev 000 Page 5 of 8
B/E AEROSPACE
Service Bulletin
CAUTION: DO NOT MAKE THE INSIDE DIAMETER OF THE MASK BAG ASSEMBLY TUBE (1)
LARGER THAN THE DIAMETER NEEDED TO PUT THE TUBE OVER THE OUTSIDE
OF THE FITTING OF THE NEW FLOW INDICATOR (3). DO NOT MAKE THE INSIDE
DIAMETER OF THE MASK BAG ASSEMBLY TUBE (1) SO LARGE THAT THE TUBE
SPLITS OR DISCOLORATION OF THE TUBE OCCURS.

(2) Attach the prepared end of the mask bag assembly tube (1) to the clear window end of the flow
indicator (3). Slide the tubing on the open end of the flow indicator (3) until the mask bag assembly
tube (1) end meets the shoulder of the flow indicator (3).

CAUTION: WHILE PUTTING THE TUBE (1) ON THE FLOW INDICATOR (3), DO NOT USE TOO
MUCH FORCE THAT MAY DAMAGE THE FLOW INDICATOR (3).

NOTE: Momentarily dipping the tube (1) end into denatured alcohol or isopropyl alcohol
(commercially available) will make it easier to slide the tube (1) on the flow indicator (3).

(3) Use the Tubing Stretcher Tool part number 997300-00 (refer to Figure 2) to expand the inside
diameter of the end of the supply tube (4).

CAUTION: DO NOT MAKE THE INSIDE DIAMETER OF THE SUPPLY TUBE (4) LARGER THAN
THE DIAMETER NEEDED TO PUT THE TUBE OVER THE OUTSIDE OF THE
FITTING OF THE NEW FLOW INDICATOR (3). DO NOT MAKE THE INSIDE
DIAMETER OF THE SUPPLY TUBE (4) SO LARGE THAT THE TUBE SPLITS OR
DISCOLORATION OF THE TUBE OCCURS.

(4) Attach the prepared end of the supply tube (4) on the end of the flow indicator (3) having the green
marking. Slide the tubing on the open end of the flow indicator (3) until the supply tube (4) end meets
the shoulder of the flow indicator (3).

CAUTION: WHILE PUTTING THE TUBE (4) ON THE FLOW INDICATOR (3), DO NOT USE TOO
MUCH FORCE THAT MAY DAMAGE THE FLOW INDICATOR (3).

NOTE: Momentarily dipping the tube (4) end into denatured alcohol or isopropyl alcohol
(commercially available) will make it easier to slide the tube (4) on the flow indicator (3).

(5) After the tubes (1, 4) have contracted around the flow indicator (3), make sure the tubes (1, 4) are
tight on the flow indicator (3).

(6) Once the new flow indicator (3) is installed in the assembly, write on the data label on the bag
assembly with permanent ink. Write the letter “W” on the right side of the data label approximately
as shown in Figure 3.

06 Sep 2010 174080-35-04


Rev 000 Page 6 of 8
B/E AEROSPACE
Service Bulletin

Figure 2
Tubing Stretcher Tool PN 997300-00

Figure 3
Passenger Oxygen Mask

06 Sep 2010 174080-35-04


Rev 000 Page 7 of 8
B/E AEROSPACE
Service Bulletin
D. Testing (refer to Figure 3)

WARNING: IF THE NEW FLOW INDICATOR (3) IS INSTALLED BACKWARDS, THE FLOW
INDICATOR WILL NOT SHOW WHEN OXYGEN FLOWS TO THE MASK.

(1) Look for the directional arrow that has been stamped on the side of the flow indicator (3) body. The
flow directional arrow must point toward the oxygen mask bag assembly.

(2) Make sure the directional arrow and markings are in green, showing that the replacement has been
implemented.

(3) Make sure the letter "W" is on the right side of the data label (approximate location is shown in
Figure 3), showing that the replacement has been implemented.

E. Cleaning

WARNING: THE USE OF OIL AND OTHER PETROLEUM BASE LUBRICANTS ON OXYGEN
EQUIPMENT WILL CREATE A DANGEROUS FIRE HAZARD.

CAUTION: THE WORK AREA MUST BE CLEAN AND FREE OF HYDROCARBON RESIDUE, OIL,
OR OTHER PETROLEUM BASE LUBRICANTS.

CAUTION: DO NOT LET DENATURED ALCOHOL TOUCH THE MASK BAG AS IT MAY REMOVE
INK ON THE BAG.

(1) Use a clean lint-free cloth moistened with denatured alcohol to lightly wipe down the mask cup and
tubing. Do not allow cleaning solution to enter tube or reservoir bag.

(2) Denatured alcohol can be used to remove stains or contamination.

(3) Allow the mask assembly to fully dry after cleaning.

III. Material Information


Table 1
Materials List

FIG. ITEM INSTRUCTIONS/


NO. NO. NEW PART NO. QTY DESCRIPTION OLD PART NO. DISPOSITION

2,3 1 MASK BAG ASSY VARIES REUSE


TUBING
1,3 2 1 FLOW INDICATOR 118023-02 DISCARD
1,3 3 118023-12 1 FLOW INDICATOR NEW
2,3 4 SUPPLY TUBING VARIES REUSE

06 Sep 2010 174080-35-04