Clause Conditions Provision Comments

ND1.2 Number of exits (minimum) All buildings 1


building rise >=3 storey
Class 2 to 8 buildings 2
Effective height>10m
point from which travel in max distance to
ND1.4 Exit travel distances Class 5 or 6 buildings different directions to 2 exits is one of the exit
available <= 40m
Distance from any point on
floor an a point of egress to a
Travel by non-fire- Isolated
ND 1.9 Class 5 or 6 buildings road or open space by way of a Dist < 80m
stairways or ramps.
required non-fire-isolated
stairway or ramp.
Number of persons
ND 1.13 Type of use : Shop (b) all other levels 5m2 per person
accomodated
Open area = [48.2 m2 (L) * 35.8 m2 (w)]-
Total open area as per ND 1.15 requirements 2 waiting room area [ 5.6 m2 (L) * 4.4 m2
1700.92 m
(w)]

Number person = ( total open area/5m2


Total number persons On storey 2 341 persons
per person)
ND 1.6 Dimension of exits Height H>=2m
2m+ 500mm for every 60
persons(or part) in excess of
WIDTH
200 persons if egress involves Total open area = 1700.92 m2
Storey accomodating > 200 3.175 m
a change in floor level by a
persons
stairway or ramp with a
gradient more than 1:12