EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH

CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

Lab ID#: TT75001726


Report: 20PS1726A
Receipt Date: Aug 25, 2020
Test Date: Dec 10, 2020 Report Date: Jan 20, 2021

DUT INFORMATION DUT SPECIFICATIONS

Brand Thermaltake Rated Voltage (Vrms) 100-240

Manufacturer (OEM) Channel Well Technology Rated Current (Arms) 10

Series Smart BM2 Rated Frequency (Hz) 47-63

Model Number SPD-0750MNFABE-1 Rated Power (W) 750

Serial Number PSSPD0750MNFABE1XL000656 Type ATX12V

DUT Notes 140mm Rifle Bearing Fan


Cooling
(TT-1425 DF1402512SEMN)

Semi-Passive Operation ✗

Cable Design Semi Modular

TEST EQUIPMENT

Chroma 63601-5 x4
Chroma 63600-2 x2
Electronic Loads
63640-80-80 x20
63610-80-20 x2

AC Sources Chroma 6530, Keysight AC6804B

Power Analyzers N4L PPA1530 x2

Sound Analyzer Bruel & Kjaer 2270 G4

Microphone Bruel & Kjaer Type 4955-A

Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2

Tachometer UNI-T UT372 x2

Digital Multimeter Keysight U1273AX, Fluke 289, Keithley 2015 - THD

UPS CyberPower OLS3000E 3kVA x2

Transformer 3kVA x2

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 1/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

RESULTS

Temperature Range (°C /°F) 30-32 / 86-89.6 (+-2℃ / +- 3.6℉)

ErP Lot 3/6 Ready ✓

(EU) No 617/2013 Compliance ✓

ALPM (Alternative Low Power Mode) compatible ✓

115V 230V

Average Efficiency 85.921% Average Efficiency 88.238%

Efficiency With 10W (≤500W) or 2% (>500W) 66.029 Average Efficiency 5VSB 79.484%

Average Efficiency 5VSB 80.276% Standby Power Consumption (W) 0.0842092

Standby Power Consumption (W) 0.0405229 Average PF 0.960

Average PF 0.984 Avg Noise Output 35.18 dB(A)

Avg Noise Output 35.56 dB(A) Efficiency Rating (ETA) SILVER

Efficiency Rating (ETA) SILVER Noise Rating (LAMBDA) Standard+

Noise Rating (LAMBDA) Standard+

POWER SPECIFICATIONS

Rail 3.3V 5V 12V 5VSB -12V

Amps 20 20 62.5 2.5 0.3


Max. Power
Watts 120 750 12.5 3.6

Total Max. Power (W) 750

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 2/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

CABLES AND CONNECTORS

Native Cables
Description Cable Count Connector Count (Total) Gauge In Cable Caps

ATX connector 20+4 pin (600mm) 1 1 18AWG No

8 pin EPS12V (660mm) / 4+4 pin EPS12V (150mm) 1 1/1 18AWG No

Modular Cables
6+2 pin PCIe (500mm+150mm) 2 4 18AWG No

SATA (500mm+150mm+150mm) 3 9 18AWG No

4-pin Molex (500mm+150mm+150mm+150mm) / FDD (+150mm) 1 4/1 18-20AWG No

AC Power Cord (1380mm) - C13 coupler 1 1 18AWG -

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 3/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

General Data -
Manufacturer (OEM) CWT

PCB Type Single Sided

Primary Side -
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV, 1x Power Integrations CAP200DG (Discharge IC)

Inrush Protection NTC Thermistor SCK-1R55 (1.5 Ohm)

Bridge Rectifier(s) 1x GBU1506 (600V, 15A @ 100°C)

APFC MOSFETs 2x Great Power GP28S50G (500V, 28A, Rds(on): 0.125Ohm)

APFC Boost Diode 1x ON Semiconductor FFSP0665A (650V, 6A @ 153°C)

Bulk Cap(s) 1x Nichicon (420V, 390uF, 2,000h @ 105°C, GG)

Main Switchers 2x Great Power GP23S60HX

PFC / PWM Combo Controller Champion CM6800TX & Champion CM03X

Primary side: APFC, Double Forward


Topology
Secondary side: Semi - Synchronous Rectification (12V) & DC-DC converters (5V & 3.3V)

Secondary Side -
2x Advanced Power AP6N3R5P (60V, 80A @ 100°C, Rds(on): 3.58mOhm) FETs & 2x PFC PFR40V60CT (60V, 40A @ 100°C)
+12V
SBRs & 1x Sync Power SP6019 Driver IC

DC-DC Converters: 4x Sync Power SPN3006 (30V, 57A @ 100°C, Rds(on): 5.5mOhm)
5V & 3.3V
PWM Controllers: ANPEC APW7159C

Electrolytic: 2x CapXon (2-5,000h @ 105°C, KF), 6x CapXon (2-5,000h @ 105°C, GF), 10x Chengx (2-4,000h @ 105°C, GR), 1x
Filtering Capacitors CapXon (5-10,000h @ 105°C, KH)
Polymer: 2x APAQ

Supervisor IC IN1S429I-DCG

Fan Model Thermaltake TT-1425 (DF1402512SEHN) (140mm, 12V, 0.60A, Sleeve Bearing Fan)

5VSB Circuit -
Standby PWM Controller Power Integrations TNY287PG

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 4/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE


INFO

The PSU`s efficiency under high ambient


temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used

5VSB EFFICIENCY
INFO

This graph depicts the efficiency levels of the 5VSB


rail with 115V and 230V input

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 5/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.045A 0.230 0.034


1 73.248%
5.101V 0.314 115.13V

0.090A 0.459 0.063


2 77.929%
5.100V 0.589 115.13V

0.550A 2.801 0.254


3 82.213%
5.091V 3.407 115.13V

1.000A 5.083 0.329


4 82.090%
5.082V 6.192 115.13V

1.500A 7.608 0.373


5 79.665%
5.071V 9.550 115.12V

2.500A 12.630 0.416


6 77.537%
5.052V 16.289 115.13V

5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.045A 0.230 0.013


1 63.536%
5.102V 0.362 230.21V

0.090A 0.459 0.022


2 71.163%
5.101V 0.645 230.23V

0.550A 2.801 0.111


3 78.879%
5.093V 3.551 230.21V

1.000A 5.084 0.176


4 80.545%
5.084V 6.312 230.21V

1.500A 7.610 0.229


5 80.376%
5.073V 9.468 230.21V

2.500A 12.637 0.293


6 80.424%
5.055V 15.713 230.21V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 6/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

115V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 7/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

EFFICIENCY GRAPH 115V


INFO

This graph depicts the PSU’s efficiency throughout


its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations

NOISE GRAPH 115V


INFO

The PSU’s noise in its entire operational range and


under 30-32 °C (+-2 °C) ambient is depicted in this
graph. The X axis represents the load on the +12V
rail(s) while the Y axis is the load on the minor rails

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 8/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

VAMPIRE POWER -115V


INFO

This graph is generated by the PPA Standby Power


Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 9/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

COMMISSION REGULATION (EU) NO 617/2013 TESTING 115V

DC/AC Fan Speed PSU Noise Temps PF/AC


Test # 12V 5V 3.3V 5VSB Efficiency
(Watts) (RPM) (dB[A]) (In/Out) Volts

4.406A 1.994A 1.998A 0.986A 74.968 34.09°C 0.960


1 85.455% 871 25.0
12.112V 5.017V 3.303V 5.071V 87.728 36.11°C 115.12V

9.849A 2.993A 3.000A 1.186A 150.049 34.63°C 0.976


2 88.567% 873 25.0
12.097V 5.014V 3.300V 5.058V 169.418 37.43°C 115.12V

26.895A 4.994A 5.011A 1.794A 374.650 36.32°C 0.989


5 88.543% 879 24.9
12.052V 5.007V 3.293V 5.020V 423.130 41.76°C 115.11V

55.370A 9.012A 9.056A 2.523A 749.833 39.55°C 0.993


10 82.386% 2125 49.4
11.967V 4.995V 3.280V 4.955V 910.144 50.61°C 115.08V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 10/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

230V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 11/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

EFFICIENCY GRAPH 230V


INFO

This graph depicts the PSU’s efficiency throughout


its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations

NOISE GRAPH 230V


INFO

The PSU’s noise in its entire operational range and


under 30-32 °C (+-2 °C) ambient is depicted in this
graph. The X axis represents the load on the +12V
rail(s) while the Y axis is the load on the minor rails

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 12/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

VAMPIRE POWER -230V


INFO

This graph is generated by the PPA Standby Power


Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 13/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

COMMISSION REGULATION (EU) NO 617/2013 TESTING 230V

DC/AC Fan Speed PSU Noise Temps PF/AC


Test # 12V 5V 3.3V 5VSB Efficiency
(Watts) (RPM) (dB[A]) (In/Out) Volts

4.407A 1.994A 1.996A 0.987A 74.969 34.19°C 0.867


1 86.383% 675 18.2
12.110V 5.017V 3.303V 5.069V 86.787 37.25°C 230.25V

9.852A 2.988A 3.001A 1.187A 150.050 34.71°C 0.934


2 90.160% 678 18.0
12.095V 5.015V 3.300V 5.056V 166.426 38.67°C 230.24V

26.898A 4.993A 5.012A 1.794A 374.633 36.50°C 0.974


5 90.740% 686 18.2
12.050V 5.008V 3.293V 5.019V 412.863 43.47°C 230.24V

55.366A 9.011A 9.057A 2.523A 749.838 39.95°C 0.987


10 85.987% 2128 49.4
11.968V 4.995V 3.280V 4.955V 872.038 51.58°C 230.24V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 14/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Thermaltake Smart BM2 750W

Top side Power specifications label

CERTIFICATIONS 115V

Aristeidis Bitziopoulos
Lab Director

CERTIFICATIONS 230V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 15/14
› The link to the original test results document should be provided in any case

www.cybenetics.com -info@cybenetics.com
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus

You might also like