> EASYLINK ISO 9001/13485/14001/45001

Basic Fully Auto Biochemistry Analyzer

Advantage

1.Standard mixing programme for excellent mixing results

2.54 reagent positions, 27 sample positions

3.The user-friendly software interface is simple and easy to operate

4.Automatic sample dilution (decrease, increase, normal)

5.Automatic reaction result checking and alarm, automatic calibration result checking and alarm logging

6.Quality control applies to westbound, LT charts, cumulative

7.A dedicated sampling probe equipped with a sensitive liquid sensor for timely reagent and sample residue feedback.

Specification
Model
Model BA-120I
Sample 27 positions for sample
Reagent 54 positions for reagent
Volume 27 bottles with volume of 8ml
27 bottles with volume of 20ml
Function Liquid level detection
Collision protection
High pressure water flush interior the probe
Carry-over <0.1%
Shipping size(W×D×H)(mm) 730x440x480
N.W./G.W. (kg) 28/33
> EASYLINK ISO 9001/13485/14001/45001

Versatility Fully Auto Biochemistry Analyzer

Advantage

1.Provide a variety of print formats, and you can freely select the
format and content

2.Dedicated user management password, reasonable allocation of


user operating privileges

3.Can save measurement data and back up automatically

4.Test speed 180T/H (without ISE)

5.30 sample positions and 60 reagent positions

6.Automatic probe cleaning, liquid level detection, collision protection

7.Accurate measurements are fast and accurate analyses of various


biochemical parameters.

8.Different biochemical parameters, including blood, urine and other


body fluids, can be analyzed. Specification

Model BA-200
Specification
Reagent bottle Reagent bottles with volume of 15ml, 20ml, 30ml, 50ml, 60ml, 70ml can be used, the dead volume is less than
Model BA-200 1ml

Working mode Discrete/random access Mixing bar Independent mixing bar, special material, surface treatment using Teflon, not hanging liquid, thoroughly clean

Test speed Test speed 180T/H (without ISE) before and after mixing to prevent cross contamination

Test principle Absorbance photometry, Turbidimetry Reagent/sample Handing

End-point, Fixed-time, Kinetic, Single/Dual reagent chemistries, monochromatic/bichromatic linear/non-linear Reagent/sample tray 60 positions for reagents and 30 positions for samples in refrigerated compartment (4~16℃)

Methodology multi-point calibration Reagent volume 20-500μl, step by 1μl

The longest reaction time 15 minutes Sample volume 2~100μl, step by 0.1μl

Minimum reaction volume 150μl Reagent/Sample probe Liquid level detection, collision protection and inventory checking

Cuvettes material Plastics (quartz glass can be selected), 81 cuvettes have the function of automatically deducting reagent and Probe cleaning Automatic washing for both interior and exterior Carry-over < 0.1%

sample blanks Calibration and quality control

Linear range of absorbance 0-3.8Abs Quality control type Real time quality control, daily quality control, day to day quality control

Halogen light source using time ≥ 2000 hours Quality control charts L-J, Cumulative, Twin Plot

Wavelength 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm The quality control rules Arbitrarily formulated by default to Westguard multiple rules

Refrigeration system Water medium uniform refrigeration technology The calibration type linear and nonlinear. Logit-4P, Logit-5P, Spline, exponent, polynomial, factor method

Reagent storehouse temperature 4-16℃ Calibration Automatically check the calibration curve and select the best calibration type of the fitting degree automatically

Reaction temperature 37±0.2℃ Operating System

Temperature fluctuation ±0.1℃ English operating system Windows2000, windows XP, windows7, windows8, windows10

Shipping size(W×D×H)(mm) 930x730x780 Report printing Make print format and content freely, provide several common formats

N.W./G.W. (kg) 65/110 User management Special user management password, rational distribution of user operation permissions

Sampling and mixing system Interface RS-232 standard interface, support for intranet, remote print report

Sample capacity 2-30μl, 0.1μl increasing Databases Optional various databases, autosave, automatic backup, save all kinds of data permanently

Sample probe Sharing with the reagent probe, the inner and outer walls are highly polished, with the function of liquid level Real-time monitoring of sample tray, reagents tray, reacting tray; Real-time display of reaction temperature,

detection, tracking and collision protection, sample probe matching special cleaning liquid, prevent cross reagent allowance, reaction curve, calibration curve and quality control chart

contamination Check and judge reaction endpoint, reaction linear interval, substrate exhaustion, reagent blank absorbance,

Reagent capacity 20-300μl, 0.1μl increasing etc.

Reagent probe Sharing with the sample probe Language English, Chinese

1 2
> EASYLINK ISO 9001/13485/14001/45001

High Throughput Auto Biochemistry Analyzer

Advantage

1.300 tests per hour continuously.

2.120 sample positions and 80 reagent positions.

3.8-wavelength inverted optics.

4.Real-time quality control and automatic checking of calibration


curves and automatic selection of optimal type.

5.QC charts LJ, cumulative, dual charts.

6.Free to set the print format and content, and automatic saving, Specification
automatic backup, and permanent preservation of various types of
data.
Model BA-300
7.RS-232 standard interface, support for intranet, remote printing Reagent bottle Reagent bottles with volume of 15ml, 20ml, 30ml, 50ml, 60ml and 70ml can be used, and the dead volume is
reports. less than 1ml
Mixing bar Double mixing bar, S and R2 independent mixing bar to reduce cross contamination. The mixing bar is made of
special material, surface treatment using Teflon, not hanging liquid, thoroughly clean before and after mixing to

Specification prevent cross contamination


Reagent Handing
Model BA-300 Reagent tray 80 positions in refrigerated compartment(4~16℃)
Working mode Discrete/random access Reagent volume R1: 150~300 μL, R2: 20~150 μL
Test speed Test speed 300T/H (without ISE) Reagent probe Liquid level detection, collision protection and inventory check
Test principle Absorbance photometry, Turbidimetry Probe cleaning Interior and exterior automatic probe washing
Methodology End-point, Fixed-time, Kinetic, Single/Dual reagent chemistries, monochromatic/bichromatic Linear/non-linear Sample Handing
multi-point calibration Sample tray 120 positions for sample primary or secondary tubes and sample cups
The longest reaction time 15 minutes Sample volume 2~100μl, step by 0.1μl
Minimum reaction volume 150μl Sample probe Liquid level detection, clot detection and collision protection
Cuvettes material Plastics (quartz glass can be selected), 81 cuvettes have the function of automatically deducting reagent and Probe cleaning Interior and exterior automatic probe washing carry-over<0.05%
sample blanks Calibration and quality control
Linear range of absorbance 0-3.8Abs Quality control type Real time quality control, daily quality control, day to day quality control
Halogen light source using time ≥ 2000 hours Quality control charts L-J, Cumulative, Twin Plot
Wavelength 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm The quality control rules Arbitrarily formulated by default to Westguard multiple rules
Refrigeration system Water medium uniform refrigeration technology The calibration type linear and nonlinear. Logit-4P, Logit-5P, Spline, exponent, polynomial, factor method
Reagent storehouse temperature 4-16℃ Calibration Automatically check the calibration curve and select the best calibration type of the fitting degree automatically
Reaction temperature 37±0.2℃ Operating System
Temperature fluctuation ±0.1℃ English operating system Windows2000, windows XP, windows7, windows8, windows10
Shipping size(W×D×H)(mm) 1000x800x795 Report printing Make print format and content freely, provide several common formats
N.W./G.W. (kg) 89/135 User management Special user management password, rational distribution of user operation permissions
Sampling and mixing system Interface RS-232 standard interface, support for intranet, remote print report
Sample capacity 2-30μl, 0.1μl increasing Databases Optional various databases, autosave, automatic backup, save all kinds of data permanently
Sample probe The inner and outer walls are highly polished, with the function of liquid level detection, tracking and collision Real-time monitoring of sample tray, reagents tray, reacting tray;Real-time display of reaction temperature,
protection, sample probe matching special cleaning liquid, prevent cross contamination reagent allowance, reaction curve, calibration curve and quality control chart
Reagent capacity 2-300μl, 0.1μl increasing Check and judge reaction endpoint, reaction linear interval, substrate exhaustion, reagent blank absorbance,
Reagent probe The inner and outer walls are highly polished, with the function of liquid level detection, tracking and collision etc.
protection Language English, Chinese

1 2

You might also like