Generic type and use of construction Thermal break made of cellular glass for masonry walls
product:
1. This European Technical Approval is issued by SGS INTRON Certificatie B.V. in accordance with:
Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and
1
2. SGS INTRON Certificatie B.V. is authorised to check whether the provisions of this European Technical Approval
are met. Checking may take place in the manufacturing plants. Nevertheless, the responsibility for the conformity of
the products to the European Technical Approval and for their fitness for intended use remains with the holder of
the European Technical Approval.
3. This European Technical Approval is not to be transferred to other manufacturers or agents of manufacturers other
than those indicated on page 1, or manufacturing plants other than those laid down in the context of this European
Technical Approval.
4. This European Technical Approval may be withdrawn by SGS INTRON Certificatie B.V. in particular pursuant to
information by the Commission according to Article 5.1 of the Council Directive 89/106/EEC.
5. Reproduction of this European Technical Approval including transmission by electronic means shall be in full.
However, partial reproduction can be made with the written consent of SGS INTRON Certificatie B.V. In this case
partial reproduction has to be designated as such. Texts and drawings of advertising brochures shall not contradict
or misuse the European Technical Approval.
6. The European Technical Approval is issued by the approval body in its official language. This version corresponds
fully to the version circulated within EOTA. Translations into other languages have to be designated as such.
1
Official Journal of the European Communities nº L 40, 11.2.1989, p.12
2
Official Journal of the European Communities nº L 220, 30.8.1993, p.1
3
Official Journal of the European Union nº L 284, 31-10-2003, p.25
4
Official Journal of the European Communities nº L 17, 20.1.1994, p.34
Page 3 of 14 pages – European Technical Approval PERINSUL® S - ETA-13/0004
Thermal break made of cellular glass, with a bitumen/PE-liner, for masonry walls, called PERINSUL® S
The thermal break made of cellular glass, called PERINSUL® S, is designed to be incorporated in masonry walls. The
masonry walls with the thermal break shall assure the stability in accordance with the EN 1996-01 and the energy
performances to prevent heat losses and mould growth/surface condensation.
The use categories in accordance with EOTA TR 034 are IA3 and S/W 3: ”products which are completely covered with
tight products capable of avoiding any kind of migration of dangerous substances to indoor air, soil and water”.
Both in regard to design and installation, the use of the thermal break units is subject to the standards and regulations in
force at the place of use. For possible uses of PERINSUL® S see Annex 1.
The provisions, assessment methods and the verification included or referred to in this ETA have been written based
upon the intended working life of the thermal break, called PERINSUL® S, for the intended use of 50 years provided that
the conditions laid down in sections 4 and 5 for packaging / transport / storage / installation / use / maintenance / repair
are met. The indications given on the working life cannot be interpreted as a guarantee given by the producer, but are to
be regarded only as a means for choosing the right products in relation to the expected economically reasonable working
life of the works.
2.1 General
This ETA is issued for thermal break made of cellular glass, called PERINSUL® S, on the basis of the information
deposited at SGS INTRON Certificatie B.V.
In general:
Within this ETA, following the procedure described in the EN 1996-1-1, following masonry units and mortar
types have been tested:
Masonry units fb General fm
N/mm2 Purpose N/mm2
(MPa) Mortar (MPa)
Calcium Silicate units; Group 1 1) 12 M5 5
Clay units; Group 1 – solid clay bricks without any holes 15 M5 5
Clay units; Group 2 1) 17.5 M5 5
1) Hole patterns of the masonry units, used at the tests: see annex 3.
Page 4 of 14 pages – European Technical Approval PERINSUL® S - ETA-13/0004
The information given below is only valid for brick types which are at least equivalent to the tested types. For
the use, the design and the installation of the thermal break, the design values of the mechanical strength shall
further consider local specifications in force at the place of use.
The characteristic compressive strength of masonry fk with the thermal break included is given in the
table below:
Values of fk for PERINSUL®S with compressive strength fb,tb = 1.8 N/mm² (MPa)
Masonry units fb General fm fk
N/mm2 Purpose N/mm2 N/mm2
(MPa) Mortar (MPa) (MPa)
Calcium Silicate units; Group 1 1) 12 M5 5 1.2
Clay units; Group 1 15 M5 5 0.9
Clay units; Group 2 1) 17.5 M5 10 0.9
1) The values of the compressive strength of masonry fk only apply for units at least equivalent to the tested units, see annex 3.
where:
- fb,tb is the normalized mean compressive strength of the thermal break units, in the direction
of the applied action effect according to EN 771-1, in N/mm2.
- fb is the normalised mean compressive strength of masonry units, in the direction of the applied action effect
according EN 772-1, in N/mm2
- fm is the compressive strength of the mortar according EN 1015-11, in N/mm2
- fk is the characteristic compressive strength of the masonry with the thermal break included according to
EN 1052-1 in N/mm2. The values are only valid for short term loading, as for the design value for the long-term
compressive strength of PERINSUL®S units see 2.2.4.4.
The chemical constitution and composition of the "thermal break made of cellular glass for masonry
walls" and/or constituents of the product is deposited at the Approval Body which will maintain strict
rules of confidentiality.
Further a written declaration is deposited at the Approval Body stating whether or not and in which
concentration "thermal break made of cellular glass for masonry walls" and/or constituents of the
product contains substances which have to be classified as dangerous according to Directive
67/548/EEC and Regulation (EC) No 1272/2008 and listed in the "Indicative list on dangerous
substances" of the EGDS - taking into account the installation conditions of the construction product
and the release scenarios resulting from there.
2.2.6 Energy economy and heat retention (Regulatory characteristic 6 of the product).
A number of default values of thermal linear transmittance, determined according to EN ISO 10211/
EN ISO 14683, are given in Annex 2.
2.2.7.5 Geometry
For geometry (length, width, thickness, squareness, flatness) PERINSUL® S the declared values and
tolerances are given in table 2:
Characteristic Test method Declared value Tolerance
2.2.7.6 Density
Density of the units, determined according to EN 1602 is 165 kg/m³ (±15%)
Method of verification:
Thickness to be determined by use of digital callipers (accuracy of 0,01 mm) in combination with a microscope.
Thickness measurement to be performed on the upper- and lower side of the unit in the area of the edges
(distance to edge 0.5 cm) as well as in the middle of the unit, on three different places.
3.2 Responsibilities
3.2.1 Tasks of the manufacturer
The manufacturer may only use initial / raw / constituent materials stated in the technical documentation of this European
Technical Approval.
The factory production control shall be in accordance with the “Control plan” relating to the European Technical Approval
ETA- 13/0004 issued on13th of May 2013which is part of the technical documentation of this European Technical
Approval. The control plan is laid down in the context of the factory production control system operated by the
manufacturer and deposited with SGS INTRON Certificatie B.V.
The results of the factory production control shall be recorded and evaluated in accordance with the provisions of the
control plan.
The certification of the factory production control by an approved Certification Body is based on the results of:
- Initial inspection of the factory production control.
- Continuous surveillance, assessment and approval of factory production control.
The approved certification body involved by the manufacturer shall issue an EC certificate of conformity of the factory
production control sating the conformity with the provisions of this European technical Approval.
Page 9 of 14 pages – European Technical Approval PERINSUL® S - ETA-13/0004
3.3 CE Marking
CE marking5 shall be affixed on the packaging of the PERINSUL® S. The letters“CE” shall be followed by the
identification number of the approved certification body, where relevant, and be accompanied by the following additional
information:
- Name and address of the producer (legal entity responsible for the manufacturer)
- The last two digits of the year in which the CE marking was affixed,
- Number of the EC certificate for the factory production control (system 2+),
- Number of European Technical Approval (ETA),
- Characteristics, performances, etc. of the product:
- Fire reaction class (EN 13501-1)
- Thermal conductivity/resistance (λD W/mK & RD m2K/W)
- Compressive strength of the block (EN772-1) – mean value fb ≥…. N/mm²
- Creep-long term (EN1606) CC ≥…. N/mm²
Both in regard to design and installation, the use of the thermal break units is subject to the standards and regulations in
force at the place of use
4 Assumptions under which the fitness for the product for the intended use was
favourably assessed
4.1 Manufacturing
The European Technical Approval is issued for the product on the basis of agreed data / information, deposited with SGS
INTRON Certificatie B.V., which identifies the product that has been assessed and judged. Changes to the product or
production process, which could result in this deposited data / information being incorrect, should be notified to SGS
INTRON Certificatie B.V. before changes are introduced. SGS INTRON Certificatie B.V. will decide whether or not such
changes affect the approval and consequently the validity of the CE marking on the basis of the approval and if so
whether further assessment or alterations to the approval, shall be necessary.
4.2 Installation
The PERINSUL®-thermal break blocks are packed in boxes, transported and stored on pallets so that no damages shall
occur..
The positioning of the PERINSUL® thermal break shall respect the installation requirements of the manufacturer and be
in conformity with the state of the art of building masonry walls. Also all masonry dilatation joints and other constructive
joints shall be respected. In the design and the calculation of the ultimate stresses, the Eurocode 6 (EN 1996-1-1) in local
design requirements shall be respected.
5
Remark:
- Notes on the CE marking are stated in Guidance Paper D of the European Commission "CE marking under the
Construction Products Directive", Brussels May 2004.
Page 10 of 14 pages – European Technical Approval PERINSUL® S - ETA-13/0004
The PERINSUL® blocks are horizontally positioned one against the other in the mortar and slightly and gently knocked
with a trowel until the mortar on all slides is flowing out and a perfect adhesion is reached.
Knocking or banging with the sharp edges of the trowel or other objects shall be avoided. The vertical joints in between
the PERINSUL® are closely positioned without mortar in between. As with all masonry, direct exposure to frost should be
avoided.
For the position at the bottom of the masonry wall:
Upon the positioned PERINSUL® blocks the first layer of bricks are fully placed into the mortar and shall be installed in
such a way that the loads are reparted over the surface. spread over
For the position under windows and sills:
So as to prevent punctual loads, in between the PERINSUL® blocks and the window a reparation (eg fibre ciment board)
is to foreseen. Sills on the insulation blocks are placed in a full mortar bed.
As the PERINSUL®-thermal break layer is integrated into the masonry, no extra attention as for maintenance or repair is
necessary. Within the disposal and discharge treatment to thermal breaks can be considered on basis of the same
waste/reuse procedures as for the masonry elements.
Example detail
Legend
1. Concrete Floor
2. Watertightness slab
3. “PERINSUL”-thermal break
4. Thermal floor insulation
(eg FOAMGLAS® slabs/boards)
5. Masonry
6. Screed
7. Masonry
8. Façade-insulated plinth or
Perimeter-insulation
9. Thermal insulated cavity, ETICS,
vêtures or ventilated façade finishing
Annex 2 European Technical Approval PERINSUL® S - ETA-13/0004
Page 12 of 14 pages
Thermal resistance