Use of Particle Induced X-Ray Emission (PIXE), Particle Induced Gamma-Ray Emission (PIGE), Energy Dispersive X-Ray Analysis (EDXRF) For Detecting Trace Elements in Soil Sample

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Volume 9, Issue 4, April – 2024 International Journal of Innovative Science and Research Technology

ISSN No:-2456-2165 https://doi.org/10.38124/ijisrt/IJISRT24APR2232

Use of Particle Induced X-Ray Emission (PIXE),


Particle Induced Gamma–Ray Emission (PIGE),
Energy Dispersive X-Ray Analysis (EDXRF) for
Detecting Trace Elements in Soil Sample
Chandrashekhar Nivrutti Wani. (Sr. Lecturer Physics)
Sanjivani K.B.P. Polytechnic, Kopargaon.

Abstract:- This review paper provides a comprehensive Ion-atom interaction techniques encompass a range of
overview of trace element analysis utilizing ion-atom methodologies, including Particle Induced X-ray Emission
interaction techniques, focusing on the principles, (PIXE), Rutherford Backscattering Spectrometry (RBS), and
applications, and recent advancements in the field. Ion- Ion Beam Analysis (IBA). These techniques exploit the
atom interaction techniques, including Particle Induced X- interaction of accelerated ions with the atoms in a sample to
Ray Emission (PIXE), Particle Induced Gamma–Ray generate characteristic signals that can be used to identify and
Emission (PIGE), Energy Dispersive X-Ray Analysis quantify trace elements. By measuring the energies and
(EDXRF), Rutherford backscattering spectroscopy (RBS), intensities of the emitted particles or X-rays, researchers can
and ion beam analysis (IBA), offer unique capabilities for obtain detailed information about the elemental composition
trace element analysis with high sensitivity and minimal of the sample with high precision and accuracy.
sample preparation requirements.
In recent years, there has been a growing interest in the
The paper begins by discussing the fundamental application of ion-atom interaction techniques for trace
principles underlying ion-atom interaction techniques, element analysis due to their ability to provide quantitative
such as the interaction of energetic ions with matter and data across a wide range of elements and concentrations.
the subsequent detection of emitted X-rays or These techniques offer advantages such as minimal sample
backscattered particles. It explores the various analytical preparation requirements, rapid analysis times, and the ability
parameters that influence the sensitivity, resolution, and to analyze samples in situ without the need for extensive
depth profiling capabilities of these techniques. sample manipulation.

Furthermore, the review highlights the diverse This paper aims to review the latest developments and
applications of ion-atom interaction techniques in fields applications of ion-atom interaction techniques in trace
such as environmental monitoring, forensic science, element analysis. We will explore the principles underlying
biomedical research, and materials science. It showcases these techniques, discuss their advantages and limitations, and
how these techniques have been utilized to address specific showcase their utility through case studies in various fields.
analytical challenges, such as the detection of trace Additionally, we will highlight recent innovations and
contaminants in environmental samples or the emerging trends in the field, such as the integration of ion-
characterization of thin films and semiconductor materials. atom interaction techniques with advanced imaging and
spectroscopic methods.
I. INTRODUCTION
By providing a comprehensive overview of trace element
Trace element analysis plays a crucial role in various analysis using ion-atom interaction techniques, this paper
fields such as environmental science, geology, biology, and seeks to contribute to the broader understanding of analytical
material science. The accurate quantification of trace elements methodologies and their implications for research and
in samples provides valuable insights into processes ranging applications in diverse scientific disciplines.
from environmental pollution to the characterization of
geological formations. Among the various analytical
techniques available for trace element analysis, ion-atom
interaction techniques have emerged as powerful tools due to
their sensitivity, selectivity, and non-destructive nature.

IJISRT24APR2232 www.ijisrt.com 2156


Volume 9, Issue 4, April – 2024 International Journal of Innovative Science and Research Technology
ISSN No:-2456-2165 https://doi.org/10.38124/ijisrt/IJISRT24APR2232

 Objectives
 Investigate the sensitivity and accuracy of ion-atom
interaction techniques, such as particle-induced X-ray
emission (PIXE) and ion beam analysis (IBA), for trace
element detection.
 Assess the applicability of ion-atom interaction techniques
for identifying and quantifying trace elements in various
sample matrices, including environmental, biological, and
geological samples.
 Explore the potential of ion-atom interaction techniques
for elemental mapping and spatial distribution analysis of
trace elements within samples.
 Optimize experimental parameters, such as beam energy,
detection systems, and sample preparation methods, to
enhance the performance of ion-atom interaction
techniques for trace element analysis.
 Compare the capabilities of different ion-atom interaction
techniques, such as PIXE, Rutherford backscattering
spectrometry (RBS), and nuclear reaction analysis (NRA),
for trace element analysis in terms of sensitivity, depth
resolution, and elemental range.
Fig 1: The Ion-Beam Facility Setup at Institute of Physics
II. METHODOLOGY (IOP), Bhubaneswar, India for the PIXE measurements.

 Sample Collection:
The soil samples will be collected from the top soil,i.e.,
10 - 15 cm depth,which is usually contaminated, to study the
anthropogenic sources of pollutants. Different distances like
100m, 500 m, 1000 m and 2000 m from the industry are
planned for the sample collection. The collected soil samples
will be grinded manually. It will be passed throughfine mesh
screen and stored in polythene bag at dry place till the testing.

 Sample Preparation:
Air-dry the samples to remove moisture, and grind them
to a fine powder to ensure homogeneity. Store the prepared
samples in clean, labeled containers to avoid contamination.

 Instrumentation Setup:
Select an appropriate ion-atom interaction technique such
as Particle-Induced X-ray Emission (PIXE) or Proton-Induced
Gamma-ray Emission (PIGE). Ensure the instrumentation is
calibrated using standard reference materials with known
elemental compositions.
Fig 2: The PIGE Setup at Bhabha Atomic Research Centre
(BARC), Mumbai, India
[(a) Liquid Nitrogen Container of HPGe Detector, (b)
HPGe Detector, (c) View Port, (d) Vacuum Gauge, (e)
Blank Off and (f) Turbomolecular Pump]

IJISRT24APR2232 www.ijisrt.com 2157


Volume 9, Issue 4, April – 2024 International Journal of Innovative Science and Research Technology
ISSN No:-2456-2165 https://doi.org/10.38124/ijisrt/IJISRT24APR2232

 Sample Analysis: sample handling can affect the results and interpretation of
Load the prepared soil samples onto sample holders data.
compatible with the chosen technique. Place the sample  Matrix Effects: Soil samples often contain complex
holders in the sample chamber of the instrument, ensuring matrices with varying compositions, which can pose
proper alignment. Initiate the analysis by irradiating the challenges for elemental analysis using ion beams. Matrix
samples with a beam of ions (e.g., protons or ions of heavier effects such as interferences and background signals may
elements) generated by an accelerator. Monitor the emitted X- arise, leading to inaccuracies in quantification. Careful
rays or gamma rays resulting from ion-atom interactions calibration and correction methods are necessary to
within the sample. Capture the emitted signals using mitigate these effects.
appropriate detectors such as semiconductor detectors or
scintillation detectors. Record the energy spectra and IV. POTENTIAL APPLICATIONS:
intensities of the detected X-rays or gamma rays for each
element of interest.  Environmental Monitoring: Ion-atom interaction
techniques can be employed for environmental monitoring
 Data Processing and Analysis: of trace elements in soil, helping to assess contamination
Use dedicated software packages or algorithms to levels, identify sources of pollution, and evaluate
process the acquired spectra and determine the elemental remediation efforts. These techniques play a crucial role in
compositions of the soil samples. Apply appropriate studying the impact of human activities on soil quality and
corrections for background noise, sample matrix effects, and ecosystem health.
instrument response. Quantify the concentrations of trace  Agricultural Research: Understanding the distribution of
elements in the soil samples based on the intensities of the essential nutrients and potentially harmful elements in soil
detected signals and calibration curves obtained from standard is essential for optimizing agricultural practices and
reference materials. ensuring food safety. Ion-atom interaction techniques can
provide valuable insights into the availability and mobility
 Quality Control: of nutrients and contaminants in soil, contributing to
Implement quality control measures by analyzing sustainable agriculture and soil management strategies.
duplicate samples, blanks, and certified reference materials  Geological Studies: Beyond soil analysis, ion-atom
alongside the test samples. Monitor instrument performance interaction techniques have applications in geological
regularly through standardization and recalibration procedures. studies for characterizing rock samples, mineral
Document all analytical procedures, instrument settings, and exploration, and understanding geological processes. By
calibration details for traceability and reproducibility. analyzing trace elements in soil and sedimentary layers,
researchers can reconstruct past environmental conditions
 Data Interpretation and Reporting: and geological events.
Interpret the analytical results in the context of
environmental or agronomic considerations. Compare the V. CONCLUSION
obtained elemental concentrations with regulatory guidelines
or baseline values to assess soil quality and potential In conclusion, the utilization of ion-atom interaction
environmental risks. Prepare a comprehensive report techniques for trace element analysis in soil has demonstrated
summarizing the analytical methodology, results, significant potential and value in various fields of study.
interpretations, and any relevant recommendations. Through the employment of techniques such as proton-
induced X-ray emission (PIXE), Rutherford backscattering
 Safety Considerations: spectrometry (RBS), and nuclear reaction analysis (NRA),
Adhere to all safety protocols and guidelines for handling researchers have been able to delve into the elemental
ionizing radiation sources and hazardous materials. Ensure composition of soil samples with remarkable precision and
proper shielding and containment measures are in place to sensitivity. These techniques provide invaluable insights into
minimize radiation exposure risks to operators and the soil composition, contamination patterns, nutrient availability,
environment. and geological processes, thereby contributing to our
understanding of soil quality, ecosystem health, and geological
III. CHALLENGES history. Ion-atom interaction techniques offer powerful tools
for trace element analysis in soil, with broad implications for
 Sample Preparation: Despite the non-destructive nature of environmental science, agriculture, and geology. As we
ion-atom interaction techniques, sample preparation continue to explore and innovate in this field, the insights
remains a critical step. Soil samples need to be properly gained from these techniques will undoubtedly play a crucial
collected, homogenized, and prepared to ensure accurate role in addressing pressing global challenges and ensuring the
analysis. Contamination from external sources during health and resilience of our planet's soil ecosystems.

IJISRT24APR2232 www.ijisrt.com 2158


Volume 9, Issue 4, April – 2024 International Journal of Innovative Science and Research Technology
ISSN No:-2456-2165 https://doi.org/10.38124/ijisrt/IJISRT24APR2232

REFERENCES

[1]. United States Environmental Protection Agency,


Environmental Technology Verification Report, Field
Portable X-Ray Fluorescence Analyser, HNU Systems
SEFA-P, Office of Research and Development,
EPA/600/R-97/144 (1998).
[2]. P. D. Pérez, T. P. R. Cabello], J. C. Trincavelli, and S.
Suárez, “L shell X-ray production cross sections for Sr
and Mo by proton impact” Radiation Physics and
Chemistry, 154, 21 (2019).
[3]. J. Zhao, S. Bai, Z. An, J. Zhu, W. Tan, and M. Liu,
“Measuring the total L-Shell X-Ray production cross
sections of Te element using 6–30 keV electron impact”
Radiation Physics and Chemistry, 171, 108722 (2020).
[4]. S. A. Johansson and J. L. Campbell, “A Novel Technique
for Elemental Analysis”, Wiley, New York (1988).
[5]. Abdousalam, A.G., “Effect of heavy metals on soil
microbial processesandpopulation”, J. Biolog. Sci. 2, 9-
14 (2010).
[6]. Mohammad Muqtada Ali Khan, Ali Danish Khan,
Rashid Umar, HabibahLateh, “Study of trace elements in
groundwater of Western Uttar Pradesh, India”, Scientific
Research and Essays, 520 (20), 3175-3182 (2010).
[7]. Johansson S.A.E. and Campbell J.L. “PIXE Data
Acquisition”, Nucl. Inst. And Meth, 849, 179 (1988).
[8]. Mumtaz Oswal, Harneet Bedi, M Hajivaliei, Ashok
Kumar, KP Singh, “Trace elements of soil samples from
mining area” Nuclear Instruments and Methods in
Physics Research Section B: Beam Interactions with
Materials and Atoms, 268, 11-12, 2138-2140 (2010).
[9]. C. Boni, A. Caridi, E. Cereda, and G. B. Marcazzan,
Nuclear Instruments and Methods in Physics Research
Section B: Beam Interactions with Materials and
Atoms,45,352 (1990).
[10]. J. L. Campbell, N. I. Boyd, N. Grassi, P. Bonnick, and J.
A. Maxwell, Nuclear Instruments and Methods in
Physics Research Section B: Beam Interactions with
Materials and Atoms 268, 3356 (2010).

IJISRT24APR2232 www.ijisrt.com 2159

You might also like