Professional Documents
Culture Documents
Abid Grid
Abid Grid
Abid Grid
PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System
PVsyst TRIAL
FSE Building - Bangladesh
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: Grid Connected ET201052_Abid
Variant: New simulation variant
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
Project summary
Geographical Site Situation Project settings
FSE Building Latitude 22.50 °N Albedo 0.20
Bangladesh Longitude 91.72 °E
Altitude 9m
Time zone UTC+6
Weather data
FSE Building
Meteonorm 8.1 (1991-2012), Sat=100% - Synthetic
System summary
PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters Battery pack
Nb. of modules 20 units Nb. of units 1 unit Storage strategy: Self-consumption
Pnom total 5.00 kWp Pnom total 5.00 kWac Nb. of units 1 unit
Pnom ratio 1.000 Voltage 50 V
Capacity 268 Ah
Results summary
PVsyst TRIAL
Produced Energy
Used Energy
6586.00 kWh/year
843.35 kWh/year
Table of contents
2
3
Detailed User's needs 5
Main results 6
Loss diagram 7
Predef. graphs 8
Single-line diagram 9
PVsyst TRIAL
PVsyst TRIAL
05/05/24 PVsyst Evaluation mode Page 2/9
Project: Grid Connected ET201052_Abid
Variant: New simulation variant
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 24 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PVsyst TRIAL
Storage
Kind
Charging strategy
Self-consumption
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model TSP 250 Model HIS 48V 5.0
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 250 Wp Unit Nom. Power 5.00 kWac
Number of PV modules 20 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 5.00 kWp Total power 5.0 kWac
PVsyst TRIAL
Modules 2 string x 10 In series Operating voltage 150-425 V
At operating cond. (50°C) Max. power (=>25°C) 5.50 kWac
Pmpp 4486 Wp Pnom ratio (DC:AC) 1.00
U mpp 276 V No power sharing between MPPTs
I mpp 16 A
Battery Storage
Battery
Manufacturer Generic
PVsyst TRIAL
Model Powerwall2
Battery pack Battery Pack Characteristics
Nb. of units 1 Unit Voltage 50 V
Discharging min. SOC 20.0 % Nominal Capacity 268 Ah (C10)
Stored energy 10.9 kWh Temperature Fixed 20 °C
Battery input charger
Model Generic
Max. charg. power 3.2 kWdc
Max./Euro effic. 97.0/95.0 %
Battery to Grid inverter
Model Generic
Max. disch. power 3.2 kWac
Max./Euro effic. 97.0/95.0 %
PVsyst TRIAL
05/05/24 PVsyst Evaluation mode Page 3/9
Project: Grid Connected ET201052_Abid
Variant: New simulation variant
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
Array losses
Thermal Loss factor DC wiring losses LID - Light Induced Degradation
Module temperature according to irradiance Global array res. 284 mΩ Loss Fraction 1.0 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
05/05/24 PVsyst Evaluation mode Page 4/9
Project: Grid Connected ET201052_Abid
Variant: New simulation variant
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
PVsyst TRIAL
Lamps (LED or fluo)
TV / PC / Mobile
Winter (Dec-Feb)
Nb.
6
1
Power
W
10/lamp
75/app
Use
Hour/day
6.0
6.0
Energy
Wh/day
360
450
Lamps (LED or fluo)
TV / PC / Mobile
Spring (Mar-May)
Nb.
6
1
Power
W
10/lamp
75/app
Use
Hour/day
5.0
4.0
Energy
Wh/day
300
300
Domestic appliances 1 200/app 4.0 800 Domestic appliances 1 200/app 4.0 800
Fridge / Deep-freeze 1 24 799 Fridge / Deep-freeze 1 24 799
Stand-by consumers 24.0 144 Stand-by consumers 24.0 144
Total daily energy 2553 Total daily energy 2343
Hourly distribution
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
05/05/24 PVsyst Evaluation mode Page 5/9
Project: Grid Connected ET201052_Abid
Variant: New simulation variant
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
Main results
System Production
Produced Energy 6586.00 kWh/year Specific production 1317 kWh/kWp/year
Used Energy 843.35 kWh/year Perf. Ratio PR 77.02 %
Solar Fraction SF 100.00 %
Battery aging (State of Wear)
Cycles SOW 92.5 %
Static SOW 90.0 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
114.7
120.9
156.5
164.0
DiffHor
kWh/m²
56.60
58.77
80.52
90.38
T_Amb
°C
21.09
23.97
26.89
28.44
GlobInc
kWh/m²
143.5
141.6
168.6
162.2
GlobEff
kWh/m²
140.1
138.6
164.6
157.9
EArray
kWh
612.6
592.7
695.5
667.7
E_User
kWh
79.15
71.49
72.64
70.30
E_Solar
kWh
79.15
71.49
72.64
70.30
E_Grid
kWh
482.8
478.6
576.3
553.0
EFrGrid
kWh
0.000
0.000
0.000
0.000
May 159.5 95.79 29.26 148.6 144.0 612.6 72.64 72.64 494.6 0.000
June 133.9 94.12 28.30 122.5 118.5 513.8 60.25 60.25 410.5 0.000
July 124.5 88.11 28.25 115.3 111.6 483.4 62.25 62.25 376.7 0.000
August 138.4 82.94 28.49 133.0 129.2 550.5 62.25 62.25 443.8 0.000
September 133.4 76.24 28.29 137.5 133.8 567.9 70.30 70.30 453.6 0.000
October 126.4 70.05 28.26 141.4 137.9 584.6 72.64 72.64 466.6 0.000
November 123.7 53.19 25.47 155.2 151.7 646.9 70.30 70.30 531.4 0.000
PVsyst TRIAL
December 110.1 54.52 22.46 140.7 137.4 599.4 79.15 79.15 474.7 0.000
Year 1605.9 901.22 26.61 1710.2 1665.1 7127.6 843.35 843.35 5742.6 0.000
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb Ambient Temperature E_Solar Energy from the sun
GlobInc Global incident in coll. plane E_Grid Energy injected into grid
GlobEff Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid
PVsyst TRIAL
05/05/24 PVsyst Evaluation mode Page 6/9
Project: Grid Connected ET201052_Abid
Variant: New simulation variant
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
Loss diagram
1606 kWh/m² Global horizontal irradiation
+6.5% Global incident in coll. plane
PVsyst TRIAL
-0.57% PV loss due to irradiance level
PVsyst TRIAL
0 843
to user to user
from gridfrom solar
5743
to grid
kWh
-3.43% Battery OUT, inverter loss
PVsyst TRIAL
05/05/24 PVsyst Evaluation mode Page 7/9
Project: Grid Connected ET201052_Abid
Variant: New simulation variant
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
Predef. graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
05/05/24 PVsyst Evaluation mode Page 8/9
PVsyst V7.4.6
VC0, Simulation date:
05/05/24 00:10
PVsyst TRIAL
with V7.4.6
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL