Professional Documents
Culture Documents
Coating Procedure - Sop 03 Air Control
Coating Procedure - Sop 03 Air Control
: Coating
003
1. Ensure the compressed air line is fitted with oil / water trap in working
condition.
2. Ensure the compressor running with more than 7 bar output pressure and fitted
with blasting nozzle.
PROCEDURE 3. Mount a white cloth or absorbent paper on a stiff board.
4. Hold the blasting nozzle at about half a meter distance from the board and
blow the air onto the white cloth or absorbent paper for about 1 minute.
5. Observe for any visible impurities such as Water, Oil, Dirt etc.
6. Any presence of such impurities should call for corrective actions.
7. Corrective actions : Check & Clean the Oil / Water filter.
Install such filters on both – the input & output ends.