Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NORTHING

SURROUND FINISHES AND


SLOPES DESIGNED BY
ARCHITECT A0 ORIGINAL
SHEET SIZE

TILED GRATING MASTERPLAN


FRAME TBC

TILED GRATING
FRAME TBC

POOL COPING FINGER


GRIP TILE TBC

CHROME PLATED BRASS

250
40 TBA VACUUM POITN WITH
REMOVABLE PLUG
POOL TILES - THICKNESS TO BE
uPVC PIPE
CONFIRMED BY ARCHITECT
POOL FINISHES BUILD-UP uPVC ASTRAL CONDUIT KEY PLAN

40
SEE DETAIL 10 SHEET 520002 TILES ADHESIVE - THICKNESS - TO BE AGREED
uPVC PUDDLE FLANGE
225 RESISITANT MEMBRANE - 2mm - 3mm 2" BSP to 50od ADAPTER

37 mm TBC

m
m
75
CONCRETE THICKENESS POOL RENDER - TWO COATS OF

ø
AND PROFILE DESIGN BY 10mm THICK
STRUCUTRAL CONTRACTOR uPVC PIPE

BONDING AGENT FOR WATERPROOF


CONCRETE- 2mm THICK N
STRUCTURE DESIGN BY
STRUCTURAL ENGINEER 50od uPVC PIPE
WATERPROOF CONCRETE - FRONT FACE A
QIBL
TO BE SCABBLED - THICKENESS TO BE
CONFIRMED BY POOL CONTRACTOR NOTES - GENERAL

DEMARCATION OF POOL 410 1. THIS DRAWING IS THE COPYRIGHT OF BREWER SMITH BREWER GROUP
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE ABOVE
CONRACTOR FRONT ELEVATION SECTION CONSULTANT'S CONSENT.
2. DIMENSIONS ARE NOT TO BE SCALED FROM THIS DRAWING.
3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN METERS UNLESS
50m Pool Details - Pool Edge Detail 50m Pool Details - Pool Surface Drawoff Detail 50m Pool Details - Floor Profile 50m Pool Details - Vacuum Point NOTED OTHERWISE.
5 6 3 2
1 : 10 1 : 10 1:5 1:5 4. ANY DISCREPANCIES, EITHER BETWEEN WRITTEN DIMENSIONS AND SITE
DIMENSIONS OR WITHIN THESE DRAWINGS SHOULD BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT BEFORE EXECUTING THE
WORKS.
5. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL OTHER
DOCUMENTATION FORMING THE CONSTRUCTION CONTRACT.
6. ALL EXISTING DIMENSIONS/ LEVELS ETC. INDICATED ON DRAWINGS ARE
TO BE VERIFIED ON SITE.
7. CONTRACTOR TO SUBMIT COORDINATED SHOP DRAWINGS FOR
ENGINEER'S APPROVAL AS REQUIRED PRIOR TO COMMENCEMENT OF
WORKS AT SITE.
8. HEIGHT DATUM (COTE +0.000) IS SET ON WATER LEVEL WHICH IS +0.000m
RIYADH CONTROL POINT .
STAINLESS STEEL ASTRAL 9. ANNOTATIONS AS FOLLOWS:
ADJUSTABLE FLOOR INLET DESCRIPTION ASSOCIATED DESCRIPTIVE TEXT
UNICLASS CLAUSE SPECIFICATION SPECIFIC CLAUSE

uPVC ASTRAL CONDUIT

2" BSP to 50od ADAPTER

50od uPVC PIPE


m
m
3
12
ø

170 842

250
FRONT

95

SECTION

95
500
50m Pool Details - Wall Inlet
4
1:5
125

250
PLAN

125 STAINLESS STEEL FLOOR


ANCHOR
425

20
45 80

PLAN

842
425

SECTION

50m Pool Details - Anchor Point A STAGE 5 - 100% ISSUED FOR CONSTRUCTION 28/10/2021 SPL
8 REVISION DESCRIPTION DATE BY
1 : 10 ‫ﻣﺎﻟﻙ‬
CLIENT

750
43

PLAN
HANDRAIL ANCHOR
RESIN FIXINGS

PROGRAMME MANAGEMENT OFFICE ‫ﻣﻛﺗﺏ ﺍﺩﺍﺭﺓ ﺍﻟﺑﺭﺍﻣﺞ‬

80
95
225

MASTIC JOINT BETWEEN GRILLE FRAME AND


165 362
TILES
37

PROJECT MANAGER ‫ﻣﺩﻳﺭ ﺍﻟﻣﺷﺭﻭﻉ‬

95
260

348 88

WATERPROOF CONCRETE THICKENESS TBC


125 ‫ﺍﻻﺳﺗﺷﺎﺭﻱ ﺍﻟﻌﺎﻡ‬
170 2.5m SEPARATION LEAD CONSULTANT
X
262
420

OF LANES

PIPE CUT BACK (X/2) + 25mm


PLAN
490

AFTER TESTING

40
STAINLESS STEEL LANE
262

LOCAL ARCHITECT OF RECORD ‫ﺍﻻﺳﺗﺷﺎﺭﻱ ﺍﻟﻣﺣﻠﻲ ﻟﻠﺗﺳﺟﻳﻝ ﻭﺍﻻﻋﺗﻣﺎﺩﺍﺕ‬


1/2" REMOVABLE POST WITH HOOK
PLUG FOR TESTING
125 STAINLESS STEEL FLOOR
ANCHOR
POOL TILES - THICKNESS TO BE
PIPE BLANKED CONFIRMED BY ARCHITECT SUB CONSULTANT ‫ﺍﺳﺗﺷﺎﺭﻱ ﺛﺎﻧﻭﻱ‬
RENDER FALLS TILES ADHESIVE - THICKNESS TBA

BIM 360://4665 - MISK SCHOOLS/MC-PH01-P04-06A09-SPL-MOD-POO-927101_ SH POOL.rvt


TO PIPE

20
uPVC PIPE WATERPROOF MEMBRANE - 2mm
45 80
THICK
400sq PUDDLE FLANGE BONDED TO uPVC PIPE PROJECT ‫ﻣﺷﺭﻭﻉ‬
POOL RENDER - TWO COATS OF 9mm
HYRDOPHILIC SEAL THICK

BONDING AGENT FOR WATERPROOF


MISK SCHOOL
CONCRETE- 2mm THICK RIYADH
KINGDOM OF SAUDI ARABIA

WATERPROOF CONCRETE - FRONT FACE


SECTION SECTION DRAWING TITLE ‫ﻭﺻﻑ ﺍﻟﻣﺧﻁﻁ‬
TO BE SCABBLED - THICKENESS TO BE
SECTION CONFIRMED BY POOL CONTRACTOR
06A09 - SPORTS HALL
1
50m Pool Details - Floor Sump Detail
7
50m Pool Details - Step Ladder Detail
9
50m Pool Detail - Lane Rope Anchor
10
50m Pool Details - Wall Profile 50m POOL DETAILS
1:5 1 : 10 1 : 10 1:5 SHEET 1 OF 1
DRAWN TRL CHECKED SJ APPROVED PJR

SCALE As indicated DATE 28/10/2021 PROJ. No. 4665

ACONEX DRAWING No. REVISION

MUNICIPALITY DRAWING No. A