A330 - TSM - 21-31-00-810-879-A - Outflow Valves Do Not Close in The Ditching Configuration
A330 - TSM - 21-31-00-810-879-A - Outflow Valves Do Not Close in The Ditching Configuration
e Ditching Configuration
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM 21-31-00-710-803 Operational Test of the Outflow Valve Closing in Ditching Co
nfiguration
Ref. ASM 21-31-01
3. Fault Confirmation
SUBTASK 21-31-00-710-128-A
Do the operational test of the outflow valve-closing in ditching configuration Ref. AMM 21-31
A. -00-710-803.
4. Fault Isolation
SUBTASK 21-31-00-810-128-A
A. If the outflow valves do not close:
- replace the SWITCH/PB DITCH (13HL) on the AIR panel 225VU.
(1) If the fault continues:
- do a check and repair the aircraft wiring from the DITCHING switch (13HL) A/B
1 to the CPC 1 (311HL) AB/4B and the CPC 2 (312HL) AB/4B,
- do a check and repair the aircraft wiring from the DITCHING switch (13HL) A/B
3 to the ground Ref. ASM 21-31-01.
SUBTASK 21-31-00-740-129-A
B. Do the test given in Para. 3.