TABLA 1 DISEÑO DE LOSA NIVEL N°1
my my mx mx Muy(-) Muy(+) Mux(-) Mux(+)
Losa Losa tipo Lx Ly Lx/Ly
(-) (+) (-) (+) kg-m/m kg-m/m kg-m/m kg-m/m
1-2-A-B 6 5,5 6 0,92 956,5 508,833333 854 412,166667 4073,9248 2167,22293 3637,3568 1755,50027
1-2-B-C 6 4 5,5 0,73 1207,27273 681,363636 833,8181818 380,636364 2719,744 1534,976 1878,4256 857,4976
2-3-A-B 3 4 6 0,67 892,666667 467 542,6666667 179 2010,999467 1052,0576 1222,51947 403,2512
2-3-B-C 3 4 4 1,00 718 354 597 269 1617,5104 797,4912 1344,9216 606,0032
3-4-A-B 3 3 6 0,50 888 464 548 185 1125,2736 587,9808 694,4256 234,432
3-4-B-C 6 3 4 0,75 1240 704 827 310 1571,328 892,1088 1047,9744 392,832
4-5-A-B 7 4 6 0,67 1367,33333 790,666667 0 263,333333 3080,328533 1781,21387 0 593,237333

TABLA 2 CALCULO DE ACERO DE REFUERZO N°1


f´c Fy As
LOSA M (kg-m/m) b (cm) d (cm) As (cm2/m) Verificacion
(kg/cm2) (kg/cm2) requerido
1-2-A-B Muy(-) 4073,9248 20 22 280 4200 Asy(-) 4,90372163 ok 4,90372163
Muy(+) 2167,22293 100 22 210 4200 Asy(+) 2,60645148 ok 2,60645148
Mux(-) 3637,3568 20 22 210 4200 Asx(-) 4,37905323 ok 4,37905323
Mux(+) 1755,50027 100 22 210 4200 As(+) 2,11122954 ok 2,11122954
1-2-B-C Muy(-) 2719,744 20 22 210 4200 Asy(-) 3,27336037 ok 3,27336037
Muy(+) 1534,976 100 22 210 4200 Asy(+) 1,84599272 ok 1,84599272
Mux(-) 1878,4256 20 22 210 4200 Asx(-) 2,26017492 ok 2,26017492
Mux(+) 857,4976 100 22 210 4200 As(+) 1,03119876 Asmin 1,452
2-3-A-B Muy(-) 2010,99947 20 22 210 4200 Asy(-) 2,41979489 ok 2,41979489
Muy(+) 1052,0576 100 22 210 4200 Asy(+) 1,26518613 Asmin 1,452
Mux(-) 1222,51947 20 22 210 4200 Asx(-) 1,47065943 ok 1,47065943
Mux(+) 403,2512 100 22 210 4200 As(+) 0,48492263 Asmin 1,452
2-3-B-C Muy(-) 1617,5104 20 22 210 4200 Asy(-) 1,94607082 ok 1,94607082
Muy(+) 797,4912 100 22 210 4200 Asy(+) 0,95903331 Asmin 1,452
Mux(-) 1344,9216 20 22 210 4200 Asx(-) 1,61796979 ok 1,61796979
Mux(+) 606,0032 100 22 210 4200 As(+) 0,72874798 Asmin 1,452
3-4-A-B Muy(-) 1125,2736 20 22 210 4200 Asy(-) 1,35363278 Asmin 1,452
Muy(+) 587,9808 100 22 210 4200 Asy(+) 0,70707435 Asmin 1,452
Mux(-) 694,4256 20 22 210 4200 Asx(-) 0,83523415 Asmin 1,452
Mux(+) 234,432 100 22 210 4200 As(+) 0,28190901 Asmin 1,452
3-4-B-C Muy(-) 1571,328 20 22 210 4200 Asy(-) 1,8904794 ok 1,8904794
Muy(+) 892,1088 100 22 210 4200 Asy(+) 1,07282345 Asmin 1,452
Mux(-) 1047,9744 20 22 210 4200 Asx(-) 1,26061538 Asmin 1,452
Mux(+) 392,832 100 22 210 4200 As(+) 0,47239289 Asmin 1,452
4-5-A-B Muy(-) 3080,32853 20 22 210 4200 Asy(-) 3,70777459 ok 3,70777459
Muy(+) 1781,21387 100 22 210 4200 Asy(+) 2,14215721 ok 2,14215721
Mux(-) 0 20 22 210 4200 Asx(-) 0 Asmin 0
Mux(+) 593,237333 100 22 210 4200 As(+) 0,71339582 Asmin 1,452

TABLA 3 ARMADURA REQUERIDA EN LOSAS NIVEL N°1


Asy(-) Asx(-)
Asy(-) Asy(+) Asx(-) Asx(+) Asy(+) Asx(+)
Losa cm2/nervi cm2/nervi
cm2/m cm2/m cm2/m cm2/m cm2/nervio cm2/nervio
o o
1-2-A-B 4,90372163 2,60645148 4,37905323 2,11122954 2,45186081 1,303225738 2,18952661 1,05561477
1 Ø 18 1 Ø 14 1 Ø 18 1 Ø 12
1-2-B-C 3,27336037 1,84599272 2,26017492 1,452 1,63668019 0,922996358 1,13008746 0,726
1 Ø 18 1 Ø 12 1 Ø 16 1 Ø 12
2-3-A-B 2,41979489 1,452 1,47065943 1,452 1,20989745 0,726 0,73532971 0,726
1 Ø 14 1 Ø 14 1 Ø 12 1 Ø 12
2-3-B-C 1,94607082 1,452 1,61796979 1,452 0,97303541 0,726 0,8089849 0,726
1 Ø 14 1 Ø 12 1 Ø 12 1 Ø 12
3-4-A-B 1,452 1,452 1,452 1,452 0,726 0,726 0,726 0,726
1 Ø 12 1 Ø 12 1 Ø 12 1 Ø 12
3-4-B-C 1,8904794 1,452 1,452 1,452 0,9452397 0,726 0,726 0,726
1 Ø 14 1 Ø 12 1 Ø 12 1 Ø 12
4-5-A-B 3,70777459 2,14215721 0 1,452 1,8538873 1,071078604 0 0,726
1 Ø 18 1 Ø 16 1 Ø 12
TABLA 4 DISEÑO DE LOSA NIVEL N°2
my my mx mx Muy(-) Muy(+) Mux(-) Mux(+)
Losa Losa tipo Lx Ly Lx/Ly
(-) (+) (-) (+) kg-m/m kg-m/m kg-m/m kg-m/m
1-2-A-B 6 5,5 6 0,92 956,5 508,833333 854 412,166667 3286,9166 1748,55487 2934,6856 1416,36953
1-2-B-C 6 4 5,5 0,73 1207,27273 681,363636 833,8181818 380,636364 2194,338909 1238,44655 1515,54793 691,844655
2-3-A-B 2 4 6 0,67 892,666667 467 542,6666667 179 1622,510933 848,8192 986,350933 325,3504
2-3-B-C 2 4 4 1,00 718 354 597 269 1305,0368 643,4304 1085,1072 488,9344
3-4-A-B 2 3 6 0,50 888 464 548 185 907,8912 474,3936 560,2752 189,144
3-4-B-C 6 3 4 0,75 1240 704 827 310 1267,776 719,7696 845,5248 316,944
4-5-A-B 7 4 6 0,67 1367,33333 790,666667 0 263,333333 2485,265067 1437,11573 0 478,634667

TABLA 5 CALCULO DE ACERO DE REFUERZO N°2


f´c Fy As
LOSA M (kg-m/m) b (cm) d (cm) As (cm2/m) Verificacion
(kg/cm2) (kg/cm2) requerido
1-2-A-B Muy(-) 3286,9166 20 22 210 4200 Asy(-) 3,95670713 ok 3,95670713
0 Muy(+) 1748,55487 100 22 210 4200 Asy(+) 2,10287581 ok 2,10287581
0 Mux(-) 2934,6856 20 22 210 4200 Asx(-) 3,5322991 ok 3,5322991
0 Mux(+) 1416,36953 100 22 210 4200 As(+) 1,70334122 ok 1,70334122
1-2-B-C Muy(-) 2194,33891 20 22 210 4200 Asy(-) 2,6405595 ok 2,6405595
0 Muy(+) 1238,44655 100 22 210 4200 Asy(+) 1,48935208 ok 1,48935208
0 Mux(-) 1515,54793 20 22 210 4200 Asx(-) 1,82333712 ok 1,82333712
0 Mux(+) 691,844655 100 22 210 4200 As(+) 0,83198104 Asmin 1,452
2-3-A-B Muy(-) 1622,51093 20 22 210 4200 Asy(-) 1,95209024 ok 1,95209024
0 Muy(+) 848,8192 100 22 210 4200 Asy(+) 1,02076183 Asmin 1,452
0 Mux(-) 986,350933 20 22 210 4200 Asx(-) 1,18646457 Asmin 1,452
0 Mux(+) 325,3504 100 22 210 4200 As(+) 0,39124243 Asmin 1,452
2-3-B-C Muy(-) 1305,0368 20 22 210 4200 Asy(-) 1,56996736 ok 1,56996736
0 Muy(+) 643,4304 100 22 210 4200 Asy(+) 0,77375785 Asmin 1,452
0 Mux(-) 1085,1072 20 22 210 4200 Asx(-) 1,30529828 Asmin 1,452
0 Mux(+) 488,9344 100 22 210 4200 As(+) 0,58796269 Asmin 1,452
3-4-A-B Muy(-) 907,8912 20 22 210 4200 Asy(-) 1,09205913 Asmin 1,452
0 Muy(+) 474,3936 100 22 210 4200 Asy(+) 0,57047628 Asmin 1,452
0 Mux(-) 560,2752 20 22 210 4200 Asx(-) 0,67385301 Asmin 1,452
0 Mux(+) 189,144 100 22 210 4200 As(+) 0,22744865 Asmin 1,452
3-4-B-C Muy(-) 1267,776 20 22 210 4200 Asy(-) 1,52512409 ok 1,52512409
0 Muy(+) 719,7696 100 22 210 4200 Asy(+) 0,86556387 Asmin 1,452
0 Mux(-) 845,5248 20 22 210 4200 Asx(-) 1,01702115 Asmin 1,452
0 Mux(+) 316,944 100 22 210 4200 As(+) 0,38113331 Asmin 1,452
4-5-A-B Muy(-) 2485,26507 20 22 210 4200 Asy(-) 2,99092611 ok 2,99092611
0 Muy(+) 1437,11573 100 22 210 4200 Asy(+) 1,72829313 ok 1,72829313
0 Mux(-) 0 20 22 210 4200 Asx(-) 0 Asmin 0
0 Mux(+) 478,634667 100 22 210 4200 As(+) 0,57557648 Asmin 1,452

TABLA 6 ARMADURA REQUERIDA EN LOSAS NIVEL N°2


Asy(-) Asx(-)
Asy(-) Asy(-) Asx(-) Asx(-) Asy(-) Asx(-)
Losa cm2/nervi cm2/nervi
cm2/m cm2/m cm2/m cm2/m cm2/nervio cm2/nervio
o o
1-2-A-B 3,95670713 2,10287581 3,5322991 1,70334122 1,97835357 1,051437903 1,76614955 0,85167061
0 1 Ø 16 1 Ø 12 1 Ø 16 1 Ø 12
1-2-B-C 2,6405595 1,48935208 1,82333712 1,452 1,32027975 0,744676039 0,91166856 0,726
0 1 Ø 16 1 Ø 12 1 Ø 12 1 Ø 12
2-3-A-B 1,95209024 1,452 1,452 1,452 0,97604512 0,726 0,726 0,726
0 1 Ø 12 1 Ø 12 1 Ø 12 1 Ø 12
2-3-B-C 1,56996736 1,452 1,452 1,452 0,78498368 0,726 0,726 0,726
0 1 Ø 12 1 Ø 12 1 Ø 12 1 Ø 12
3-4-A-B 1,452 1,452 1,452 1,452 0,726 0,726 0,726 0,726
0 1 Ø 12 1 Ø 12 1 Ø 12 1 Ø 12
3-4-B-C 1,52512409 1,452 1,452 1,452 0,76256205 0,726 0,726 0,726
0 1 Ø 12 1 Ø 12 1 Ø 12 1 Ø 12
4-5-A-B 2,99092611 1,72829313 0 1,452 1,49546306 0,864146565 0 0,726
0 1 Ø 18 1 Ø 14 1 Ø 12