FIREPROTECTIONGENERALNOTES NUT ACTUATOR

COVER B
STEEL COLUMN

6.5MM THK. X 50MM


PLASTIC WATER PROOF STEEL PIPE SLEEVE W B2 X50MM
COVERSECURITY

A4
HEAT RESISTANT 100 X 6.25 X 75 LONG SCREW
CAULKING COMPOUND STEEL BARS WELDED PIPE 2-15 X 50L BOLT WITH
TO PIPE DOUBLE NUTS AND

A
MOUNTING PLATE LOCK WASHER

A2
3
PIPE 8 )
NUTWLOCKWASHER
1. ALL WORKS HERE IN INCLUDED SHALL BE EXECUTED ACCORDING DIRECTION OF
ROD DIA.

A4
ROLL VANE OPPOSITE

A4
OFF LOW ARROW TO FLOW ARROW
NUT WITH LOCK WASHER

TO THE PROVISION OF THE NATIONAL FIRE PROTECTION INSERT IN PIPE


2-15 X 50L BOLT W
3
)

A2
8

A
DOUBLE NUTS AND ROD DIA.
MOUNTING HOLE
ASSOCIATION (USA) AND LOSS PREVENTION COUNCIL(UK). LOCK WASHER
B2

A4
6.5MM THK. X 50MM
B PIPE
X 50MM

2. THE WORKS SHALL BE EXECUTED INCLOSE COORDINATION SHAPON TYPE


ESCUTCHEON PLATE
OAKUM MASTIC PACKING
STEEL COLUMN
(FOR FINISHED SURFACE) U-BOLT
WITH ALL TRADES. CONCRETE SPOUT

FLO
W
RN TYP.
CONCRETE WALL ER
AT
W
3. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE NOTE:
C WALL PIPE HANGER DETAIL
PIPE SLEEVE SHALL HAVE A MINIMUM FIRE RATING SIMILAR
EXACT LOCATION AND DIMENSIONS OF AL REQUIRED WALL TO PENETRATED WALL.
B WATER FLOW SWITCH MOUNTING ARRANGEMENT
FP-1

AND FLOOR OPENINGS. A PIPE SLEEVE THRU WALLS & BEAMS FP-1

FP-1

4. THE EXACT LOCATION OF ALL SPRINKLER HEADS SHALL BE


COORDINATED WITH THE ARCHITECTURAL CEILING LAYOUT
AND SHALL BE SUBJECTED TO BOTH THE ARCHITECTS AND FLUSH ANCHOR OR
C-CLAMP FOR STEEL

FIRE PROTECTION ENGINEERS APPROVAL. TRUSS


BOTTOM OF SLAB
UPRIGHT
SPRINKLER

A
ROUND BAR HEAD
HANGER

5. LOCATION OF DRAIN PIPES AND OF THE BACK-UP SUPPLY LINES HEXAGONAL NUTS
W WASHERS
MACHINE BOLT
W NUT A- DEFLECTORS OF SPRINKLER SHALL RN TYP.

SHALL BE COORDINATED WITH THE PLUMBING CONTRACTOR. FLUSH ANCHOR OR


C-CLAMP FOR STEEL
FLATBAR
LOWER PIPE
( 1"TO12" ) BELOW COMBUSTIBLE CEILING

NOTE:
TRUSS COUPLING REDUCER
25mm DROP NIPPLE
6. LOCATION AND MOUNTING OF FIRE HOSE CABINETS SHALL BE BOTTOM OF SLAB
ROUND BAR
CROSS MAIN AND BRANCH LINE PIPE
SHOULD BE MAXIMIZE TO THE CEILING LEVEL.
PIPESIZE STEELPLATEBAR ROD.DIA. MACHINEBOLTWNUT

COORDINATED WITH ARCHI'L FINISHES AND BE SUBJECTED HEX. NUTS W


WASHERS
FLATBARS
mm.
50
in.
2
LOWER ( thk.xW )
3.2x25MM
LOWER ( thk.xW )
4.8x25MM
mm.
9.5
in.
3/8
(DIA.xL)mm. PENDENT
SPRINKLER
COUPLING REDUCER

65 2 1/2 3.2x25MM 9.5 3/8 HEAD


TO BOTH THEA RCHITECTS AND FP. ENGR. APPROVAL.
4.8x25MM
80 3 3.2x25MM 4.8x25MM 9.5 3/8
100 4 3.2x25MM 4.8x25MM 9.5 3/8
NOTE: PIPE
150 6 4.8x32MM 6.4x32MM 12.0 1/2 CEILING

7. SIZE OF RISER NIPPLES SHALL CONFORM TO PIPE SCHEDULES F COMBINATION SPRINKLER HEADS DETAIL
FROM EXISTING BRANCH/
FP-1
AS DELINEATED IN NFPA13. CROSS MAIN AND BRANCH LINE PIPE
SHOULD BE MAXIMIZE TO THE CEILING LEVEL. E
FP-1
ADJUSTABLE TYPE CLEVIS HANGER CROSSMAIN / FEEDMAIN
(VERIFY ACTUAL/ BLDG UTY)
PIPESIZE STEELPLATEBAR ROD.DIA.
mm. in. (thick x width) mm.

8. PIPE SUPPORTS ,HANGERS AND BRACING SHALL BE OF THE


in.
25 1 3.2x19MM 9.5 38
32 2.25 3.2x19MM 9.5 38 THIS VALVE CONTROL
40 1.50 3.2x19MM 9.5 38 AUTOMATIC SPRINKLERS
BRANCH LINE
APPROVED TYPE ANDS HALL BE INDEPENDENT FROM CEILING 50 2 3.2x19MM 9.5 38

ELBOW FITTING
SPRINKLER
FIRE-ALARM
MUST ATALL
INTENT ARCHITECTURAL CEILING PLAN
OPEN PRIOR FOR INSTALLATION OF
AND DUCT SUPPORTS. D ADJUSTABLE TYPE FLAT IRON HANGER
WHEN BELL RINGS
CALL
FIRE DEPT. - POLICE
BE TIMES

TO BE HANDLED ONLY BY AUTHORIZED PERSON


OR BY EMPLOYEE CARING FOR SPRINKLER SYSTEM SPRINKLER HEADS.
RISER NIPPLE
FP-1 THREAD-O-LET (SEE PLAN FOR SIZES ) IN CASE OFFIRE

9. LOAD SIDE POWER SUPPLY CONDUIT, ROUGH-INS, & WIRING TO THE


DO NOT SHUT VALVE UNTIL FIRE IS
FITTINGS ENTIRELY OUT
WHEN VALVE IS SHUT FOR EMERGENCY REPAIRS
OR FIRE NOTIFY

FIRE PROTECTION EQUIPMENT SHALL BE BY THE FIRE SPRINKLER FLUSHING CONN. REQUEST DIRECTIONS RESTORE PROTECTION QUICKLY

FIRE PROTECTION LAYOUT


CONTRACTOR.
CROSSMAIN
ON THIS FLOOR IN THIS BUILDING IN THIS SECTION
FIRE SUPPRESSION SYSTEM LAYOUT
(SEE PLAN FOR SIZES)
10.CONTROL WIRING AND TERMINATION FROM FLOWS WITCHESTO 22MM INBOLT
EXPANSION SHIELD
LONG NIPPLE
INSPECTION TEST AUXILIARY DRAIN ALARM LINE
SCALE 1: 75 MTS

SPRINKLER SUPERVISORY ALARM CONTROL PANEL SHALL BE BY THE H FLUSHING CONNECTION DETAIL
FIRE HOSE FOR USE BY OCCUPANTS DRY STAND PIPE FOR FIRE DEPT.
CONCRETE WALL OR BEAM FP-1
FIRE SPRINKLER CONTRACTOR. FOR BUILDING USE ONLY

WELDED

11.SUPPLY,INSTALLATION AND COMMISSIONING OF SUPERVISORY IDENTIFICATION SIGNS


15MM U-BOLT
J
FP-1
F.P. LEGENDS & SYMBOLS
ALARM CONTROL PANEL SHALL BE BY FIRE SPRINKLER CONTRACTOR. 65 x 65 x 7MM
STEEL ANGLE
150MM OR 200MM

12.ACCESS FOR CONTROL VALVES SHOULD BE LOCATED NOTE:


100MM
SPRINKLER PIPE
RISERNIPPLE(RN)
AT COMMON AREAS. CROSS MAIN AND BRANCH LINE PIPE
SHOULD BE MAXIMIZE TO THE CEILING LEVEL.
FILLET WELD ALL AROUND
BOLT HOLE
GASKET

13.SHOP DRAWINGS SHALL BE PREPARED BY THE CONTRACTOR FOR G PIPE RISER BRACKET DETAIL FILLET WELD ALL AROUND
FP-1 NUT FEEDMAIN(FM)
FIRE PUMP LAYOUT,PIPE HANGER AN DO THER INSTALLATION AS MULTI PURPOSE DRY CHEMICAL
20LBS15LBS. AUTOMATIC WALL
TYPE HALOGENIC AGENT TYPE
PORTABLE FIRE EXTINGUISHER
EXTINGUISHER (ABC) 15lbs. or
HYDROCHLOROFLUOROCARBON
REQUIRED AND INDICATED IN THE SPECIFICATION. CO2 EXTINGUISHER 10lbs. (HCFC)TYPE TRACKBOLT CROSSMAIN(CM)
I FIRE EXTINGUISHER
14.ALL PIPES PASSING THRU WALLS AND FLOORS, PROVIDE PIPE SLEEVES. FP-01
BRANCHLINE(BL)
PIPE SLEEVE SHOULD HAVE PLASTIC WATERPROOF HEAT RESISTANT CONCRETESLABBEAM
HOUSING

PIPE

CAULKING COMPOUND WITH OAKUM MASTIC PACKING. 2-L 50 X 50 X 7 X 0-75 BOLTS & NUTS
GASKET
INSTALLATION OF FLUSHINGCONNECTION
N FLEXIBLE COUPLING
15.PROVIDE PIPE HANGER @ EVERY 2METERS, SWAY BRACE AND EXPN. SHIELD L 50 X 7 X 0-150MM
FP-01

CLEVIS SUPPORT @ EVERY 12METERS. REGULAR UPRIGHT


TYPE SPRINKLER HEAD
REGULAR RECESSED
PENDENT
TYPE SPRINKLER HEAD
L65 X 65 X7
WELDED
WALLCONNECTION IN EXPN. SHIELD PIPE
PIPEHANGER
13MM NPT CHROME FINISH 13MMNPTCHROMEFINISH CONNECTION
CONC. WALL

16.PROVIDE FLANGE CONNECTION EVERY 12METERS, AND ONE SIDE OR BEAM

PENDENTSPRINKLERHEAD
OF EVERY FITTING CONNECTION. ORDINARY
SIDEWALL
TYPE SPRINKLER HEAD
EXTENDED COVERAGE
SIDEWALL
TYPE SPRINKLER HEAD
L40 X 5MM

13MM NPT CHROME FINISH 20MM NPT CHROME FINISH PIPE BOLTS&NUTS GASKET

17.ALL PIPES SHOULD BI PIPE SCHEDULE 40. VERIFY LOCATION AND STD. PIPE
10LBS.CARBONDIOXIDE
ENGINEERPRIORFORSITEINSTALLATION. LATERAL CLAMP LONGITUDINAL
PFECO2 PORTABLEFIRE
L TYPE OF SPRINKLER HEAD M TWO-WAY SWAY BRACE
FP-1 FP-01
(EVERYTWOLENGTHOFPIPE) EXTINGUISHER
O FLANGE CONNECTION DETAIL
FP-01

NOTE: ANY DISCREPANCY MUST BE VERIFIED


WITH THE ARCHITECT AND THE ENGINEER.

ENGINEER : DEVELOPER / OWNER : REVISION : DESIGN BY: SHEET CONTENTS: SHEET NO.

CAD BY : CGC
FP
PAVAROTTI TEATRO RISTORANTE ITALIANO CHECKED BY : CGC
AS-SHOWN
01 01
Mr. Marco Ascione
OWNER
LOCATION: Sapphire Bloc at Sapphire, Garnet and Onyx Rd, Ortigas Center, Pasig Metro Manila DATE : APR. 2024