Professional Documents
Culture Documents
Lit and Data
Lit and Data
15
14
16
11
13 16
07
12 11 06 06
02
10 03
08 05
01
09 04
08
Auditorium space
with top skylight.
01 CAMPUS PLANNING
Literature Case Study
Mihza Fathima
CAT20AR071
MASSING CIRCULATION
Clustered massing , where the clusters are Clear circulation with no confusion , also all
spreaded out aroun the courtyard the areas are interconnected.
Primary
Secondary
AREA
ART GALLERY (80 prsn) THEATRE (500 prsn)
03
04
06 07
05
02
01 1. Thrust theatre
2. Performance lobby
3. Students lobby
4. Stairs
08 5. Elevator
6. Paint shop
7. Scene shop
8. Prop shop
MASSING
Rectangular and closed structures with leveled open spaces.
03 CAMPUS PLANNING
Literature Case Study
Mihza Fathima
CAT20AR071
THRUST THEATRE
Theatergoers gathering in the glass-enclosed lobby for the Fullerton Stage,
a 250-seat thrust theater, are also visible from the street.
AUDITORIUM ENTRANCE
Never a completely closed space , its partially open with one side full of glass Never a completely closed space , its partially open with one side full of glass
which projects outwards. The projected glass portion acts as focal point and which projects outwards. The projected glass portion acts as focal point and
it attracts the viewrs and passers. it attracts the viewrs and passers.
The look when the The school entrance opens into a lobby, lounge and concessions space
space is filled with full shared with the public entrance at the corner
of viewers , it will be
completely occupied
at even in balcony.
04 CAMPUS PLANNING
Literature Case Study
Mihza Fathima
CAT20AR071
KMBR Rules TRAVEL DISTANCE TO EMERGENCY EXIT�
Emergency exits shall be located in such a way that the travel distance on
each floor shall not exceed 30 m for every occupant.
GROUP B - EDUCATIONAL BUILDING Emergency exists may be either horizontal or vertical.
Emergency exits in the case of ground floor may be a doorway, corridor or
These shall include any building or part thereof,exceeding 200 sq. metres of passage to an internal staircase or external staircase, ramps to the street or to
built-up area, used for school, college, day-care purposes, other institutions the roof of a building,which may be horizontal exits leading to the ground or
for education or research,libraries incidental to educational buildings,reli- adjoining building at the same level. In the case of upper or lower floors,
gious educational building such as madrassa, Sunday schools & the like and emergency exits may be a staircase leading to the ground.
appurtenant assembly buildings having capacity not exceeding 200
persons.
PROVISIONS FOR DIFFERENTLY ABLED PEOPLE
EXTERIOR AND INTERIOR OPEN AIR SPACE Access to the main entrance through a ramp.
Lift dimensions for differently abled persons,
Clear internal width =110 cm
YARDS Clear internal depth= 200 cm
m BUP 200 sqm BUP > 500 sqm Entrance door width = 90 cm
Ramp slope = 1: 12
Front 5 6 Non- slippery material
Rear 2 2 Width of ramp =120 cm
Side 2 2 Handrail height= 80 cm
Entrance landing = 120x 150 cm
TOILET
COVERAGE AND FLOOR SPACE INDEX
Minimum 1 special toilet.
Maximum permissible coverage =50% Minimum size of toilet = 1.50 x 1.75 m
Maximum permissible FSI (without fees) =2.5 Minimum claer opening= 90 cm
Door shall swing out , sliding or folding type.
Maximum permissible FSI ( with fees) =3
Handrail clearance = 5 cm
Wter closet seat height = 50 cm
Sink height = 70 cm
PARKING , LOADING AND UNLOADING SPACES
PARKING FACILITIES
Dimension of each off-street parking space provided for parking motor cars
shall not be less than 5.5 metres x 2.7 metres. The area requirements for each 3 % parking near entrance for differntly abled persons.
off-street parking space for parking two-wheelers shall be 3 sq.metres and Maximum travel distance = 30 m
1.5 sq. metres respectively. Width of parking = 3.6 m
Every building above 50 sq.m of build up area shall be provided with atleast
one water closet. FIRE ESCAPE STAIRCASES�
Non residential occupancies exceeding two storeys above ground level.
CALCULATION
Width not< 1m
OCCUPANCY BUILT UP AREA / PERSON Thread not <25 cm
Riser not >19 cm
B 5.9
No.of risers not > 16 per flight
Height of handrail not< 100 cm and not > 120 cm
It may be assumed that 2/3 of the member are males and Spacing between balusters <15 cm
1/3 are females. No spiral staircase < 150 cm diameter.
Fire escape staircase shall have straight flight for building exceeding 10 m
height.
05 CAMPUS PLANNING
Data Collection
Mihza Fathima
CAT20AR071
Neuferts Standards
LECTURE HALLS
Rectangular theatre with 200 seats Trapezoidaltheatre with 400 seats Lecture theatre with 800 seats
Desk ventilation / air flow Layout of projectors, sections, showing distribution of angle
of inclined view to places above and below projectors.
Projection wall width dependent on length of lecture theatre Projection wall width dependent on length of lecture theatre
06 CAMPUS PLANNING
Data Collection
Mihza Fathima
CAT20AR071
SEMINAR AND SERVICE ROOMS
VEHICLE TURNING
07 CAMPUS PLANNING
Data Collection
Mihza Fathima
CAT20AR071
PARKING SPACES
08 CAMPUS PLANNING
Data Collection
Mihza Fathima
CAT20AR071
VERTICAL CIRCULATION
09 CAMPUS PLANNING
Data Collection
Mihza Fathima
CAT20AR071
DIFFERENTLY ABLED PERSON
10 CAMPUS PLANNING
Data Collection
Mihza Fathima
CAT20AR071
DATA
BOOK