Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Order online

Radiation Oncology ON
Brachytherapy/Ultrasound
QC Phantom
It’s the only brachytherapy/ Model 84-345
ultrasound phantom that
performs: Introduction
• Quality control on ultrasound The Brachytherapy/Ultrasound
sidefire transrectal probes and QC Phantom is designed for
calibration of prostate transrectal ultrasound QC and
calibration of brachytherapy
brachytherapy systems systems. It contains targets to
• External grid assessment assess volume measurements,
internal and external grid
• Internal grid assessment accuracy, and probe retraction
• Probe retraction step assessment accuracy. When scanning toward
the top of the phantom, a partial
• Volume verification grid of wires appears. These wires
should line up with the grid that
appears on your screen, thus
ensuring correct vertical and
horizontal distance
measurements.
A needle may be inserted through
the external grid and into the phantom, guaranteeing proper correlation between external
and internal grids. Five cross-wires are embedded within the phantom to help determine
if the probe is being retracted the specified distance.
Applications
To use the phantom, simply turn the probe 60° to the right or left to visualize and
measure the volume of three different calibrated spherical-shaped objects.
The phantom is constructed from a proprietary urethane. At normal room temperature, the
urethane material will accurately simulate the ultrasound characteristics found in human
liver tissue.

Specifications
Material Urethane Targets (cont)
Attenuation coefficient 0.50 dB/cm/MHz For volumes
± 0.05 dB/cm/MHz Material Urethane
Speed of sound 1430 m/s ± 6 m/s Approximate sizes: 4, 9 and 23 cm3
Targets (Exact volumes provided on certification
For internal grid assessment sheet)
Material Nylon monofilament Needle visualization
Diameter 0.5 mm 18-gauge needle permanently embedded
Number of targets 13 Position E2
Position B1 to B5, C4, D3, F1 to F5 Dimensions 4.45 (w) x 6.10 (d) x 5.24 in (h)
(11.3 x 15.5 x 13.3 cm)
For external grid assessment
Weight 5.25 lb (2.39 kg)
Three removable needle plugs
Available model(s)
Position A2, D5, and G2
84-345 Brachytherapy/Ultrasound QC
For probe retraction assessment Phantom
Material Nylon monofilament
Diameter 0.5 mm
For more information, receive our full product catalog, or
Number of targets 5 order online, contact Radiation Management Services
Spacing 1 cm, 1 cm, 1.5 cm, 0.5 cm business of Fluke Biomedical: 440.248.9300 or
www.flukebiomedical.com/rms.
Position Along row 4 Specifications are subject to change without notice.
©2005 Fluke Biomedical. All rights reserved. Printed in USA.
84-345-ds rev 2 03 mar 05
Order online

Afterloading Accessories ON Radiation Oncology


Models 67-905, 67-908 and 67-730
Round-Handled Fletcher-Suit and
Components:
Delclos Afterloading Applicator Set
• Right and left colpostats, with
The stainless steel ovoids are 2.0 cm in carriers and bucket assemblies for
diameter and 3.0 cm high, with an angle
of 15º. Tungsten shielding provides rectal
sources
and bladder protection.
Weight of set: 0.12 lb (0.42 kg). • Four stainless steel tandems of
Optional accessories varying curvatures
Two-Piece Nylon Jacket for Stainless
Steel Ovoid, 2.5 cm (Model 67-905-2500)
• Two regular and two flagged cervical
Two-Piece Nylon Jacket for Stainless
Steel Ovoid, 3.0 cm (Model 67-905-3000)
stops
Sterilization/Storage Case for
Afterloading Applicators (Model • One cervical stop-wrench
67-730-1000)
Available model(s)
• Four plastic tandem/pusher source
67-905 Round-Handled Fletcher-Suit
and Delclos Afterloading Applicator Set carriers

Sterilization/ Delclos Mini-


Storage Case Ovoid
for Afterloading
Afterloading Applicator Set
Applicators This set is designed for the
patient with a narrow vault.
The medical area of the ovoid
is flattened to accommodate a
Consists of a stainless steel case with a soft plastic-coated stainless
very small anatomy. The
steel liner that holds all components for gas (ethylene oxide) or cold
stainless steel unshielded
solution (Adex, Xephiren) cleaning and sterilization.
ovoids are 1.2 cm across the
Weight of set: 4 lb (2 kg).
flat surface and 2.9 cm high, with a 15º angle.
Available model(s) Weight of set: 0.75 lb (0.35 kg).
67-730-1000 Sterilization/Storage Case for Afterloading Applicators Optional accessories
Plastic Tandems (Model 67-908-5000)
Sterilization/Storage Case for Afterloading Applicators
Cervix Marker Kit (Model 67-730-1000)
Available model(s)
67-908 Delclos Mini-Ovoid Afterloading Applicator Set
Model 67-665 Order online

Implanter length 25 cm long For more information, receive our full product
Metallic marker dimensions catalog, or order online, contact Radiation
0.8 mm Ø x 5 mm long Management Services business of Fluke
Biomedical: 440.248.9300 or
Weight < 1 lb www.flukebiomedical.com/rms.
• One implanter (designed to limit Optional accessories Specifications are subject to change without notice.
implantation to 1 cm) Cervix Markers, Vial of 50 ©2005 Fluke Biomedical. All rights reserved. Printed in USA.
(Model 67-666) 67-905-ds rev 2 03 mar 05
• 50 metallic markers Implanter (Model 67-665-1000)
Available model(s)
67-665 Cervix Marker Kit, includes
50 markers

440.248.9300 www.flukebiomedical.com/rms
Order online

Radiation Oncology ON
Carriers, Cores, and Carts
Models 67-706 to 67-725
• For rapid transport of radioactive sources to bedside or operating room
• Ideal for temporary storage of approximately 100 mg Ra-eq 137Cs or 100 mg Ra

Introduction Specifications
These units are designed for safety and Carrier All-welded stainless steel shielded
convenience when transporting with 1 inch of lead
radioactive material between a Weight (approx.) 4 lb (2 kg)
permanent storage safe and the patient’s Cores Stainless steel, designed for easy lift-
bedside. The carrier and lift-out cores out. Maximum radiation level (at 1 meter
are made of corrosion-free stainless from center of shield). 5 mR/hr when 100 mg
steel, and the carrier is shielded with ra-eq 137Cs is stored; 20 mR/hr for 100 mg
1 inch of lead. It fits on a rugged, radium
Heyman Carrier Heyman Core enameled-steel cart equipped with two Weight of Fletcher-Suit Core 0.82 lb (0.37 kg)
wheels, a caster, and a long handle. Weight of Heyman Core 2 lb (0.92 kg)
Two types of lift-out cores are Cart Enameled steel; has two 8 inch wheels,
available for the Heyman Carrier: one 3 inch caster, and a 40 inch handle
Fletcher-Suit and Heyman. The Weight 14 lb (6.4 kg)
Fletcher-Suit Core holds one loaded Available model(s)
uterine source carrier and two 67-706 Cart for Heyman Carrier
loaded colpostat source carriers.
67-715 Fletcher-Suit Core
The Heyman Core holds up to 12
MICRAD or Heyman sources. 67-724 Heyman Carrier
67-725 Heyman Core

Cart for Heyman Carrier Fletcher-


Suit Core

Radioisotope Storage Safe


Model 67-745 Order online

• Provides maximum radiation Specifications


protection
Storage area in each drawer 1.75 (w) x
• Fireproof 6 (d) x 1.88 in (h) (4.45 x 15.24 x 4.76 cm)
Safe dimensions 12.75 (w) x 14.50 (d) x
• Key-locking 2.75 in (h) (32.4 x 36.83 x 32.4 cm)
Four-drawer radioisotope (Model 67-745)
• Custom-designed storage drawers Weight 950 lb (432 kg)
available Available model(s)
For more information, receive our full product catalog, or
This rugged safe ensures optimum 67-745 Radioisotope Storage Safe, four- order online, contact Radiation Management Services
business of Fluke Biomedical: 440.248.9300 or
drawers
shielding against exposure to radiation www.flukebiomedical.com/rms.
from tube sources. Made of steel with Specifications are subject to change without notice.

4 inches of lead. ©2005 Fluke Biomedical. All rights reserved. Printed in USA.
67-706-ds rev 2 03 mar 05