Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

8 7 6 5 4 3 2 1

14792
750 33 80 1441 1441 80 350 80 1163 577 10 577 1163 80 350 80 1163 812 10 342 1163 80 350 80 1587 1587 80 32 458
5245 10 4225 10 5302
2 6 F 10 6
918 B/B

℄OF TOWER ℄OF TOWER

A A
1 5 F' 9 6
750 4250 10 5900 10 4622 458

4000 4000 4000 4000


16000

TOP VIEW
B B
14792
750 360 1308 1408 350 100 725 10 415 1150 1250 350 1250 1485 345 10 1150 100 350 1554 1454 359 458
4250 10 5900 10 4622
DETAIL-C

83 50 50 50 5040 85 1 2 5 6 9 10 78 40 50 50 50 50 83

25 50 50 50 50 26
25 50 50 50 50 26

20 20 20
C 15 15 C
1000B/B

17 19 17 19 19 19 19 19 19 19 19 19 19 18 19 18
℄OF TOWER 21 21 21 ℄OF TOWER

22
20 20 20
16 DETAIL -A
16

3 4 7 8 11 12
DETAIL-B
750 5245 10 4225 10 5302 458
D 4000 4000 4000 4000 D
16000

FRONT & REAR VIEW

14792
E 750 33 80 1441 1441 80 350 80 745 10 408 1163 1163 80 350 80 1163 1492 33810 1163 80 350 80 1587 1587 80 32 458 E
4250 10 5900 10 4622
DETAIL-E
4 8 F 203
12 6

24 26 24 24 26 24 24 26 24
22 22 25 25 25 25 25 25 23 23
918B/B

℄OF TOWER 21 21 21 ℄OF TOWER

22 22 25 25 25 25 25 25 23 23
26 26 26
F F
3 7 11 6
F'
750 DETAIL-D
5245 10 4225 10 5302 458

4000 4000 4000 4000


16000

BOTTOM VIEW
G G
CLIENT :
L&T Construction
GENERAL NOTES: Solar Projects
M/S POWERTECH Constructions PVT LTD

918B/B 1. ALL DIMENSIONS ARE IN MILLIMETERS, UNLESS CUSTOMER :


M/S. CSE DEVELOPMENT INDIA PVT LTD
83 50 50 50 50 40 85 1 2 1 2 24 OTHERWISE SPECIFIED.
4 2. ALL STRUCTURE STEEL SHALL CONFIRM TO IS:2062-1992. ELECTRICAL CONTRACTOR:-
25 50 50 50 50 26

4 CLASS 5.6 AS PER IS:1367 PART-3.


15
17 20 17
22 24 26 24
19 27 27 3. ALL BOLTS SHALL BE 5.6 GRADE. POWERTECH Constructions Pvt Ltd
H 22 25 4. ALL HOLES SHALL BE 17.5Ø FOR 16Ø BOLTS UNLESS H
13 PLATE
19 19
25 50 50
310
25 10 25 50 50 25
310x65x10 THK.
21 28 OTHERWISE SPECIFIED.
ISA 21 1/40-K, PCM COLONY,
75x75x8 THK.
1000B/B

5. ALL MEMBER SHALL BE HOT DIP GALVANISED AS PER


75

ISA ST.THOMAS MOUNT, CHENNAI-600 016


Ø18mm HOLE
60x60x6 THK.
20 29 2629-1985.
PROJECT :-
PLATE
14 16 25 6. ITEM MARK SHALL BE PREFIX WITH RB1 TO READ AS RB4-1, 50 MW SOLAR POWER PLANT
42

310x65x10 THK.
17 22 26
22 RB4-2...ETC.
34

DETAIL-A DRAWING TITLE:-


25 50 50 60 50 50 25
27 27 19 7. ALL GUSSETS ARE 6MM THICK UNLESS OTHERWISE
3 STRUCTURE DETAILS FOR 230KV BEAM B1
3 4 3 4 3 SPECIFIED. DRAWING NO:-
DETAIL-B DETAIL-C DETAIL-D DETAIL-E
24 PCPL-L&T-230KV-B1 BEAM-DWG-018-R0
DETAIL F-F' R0 05-10-19 PRELIMNARY ISSUED MS AMM DLK RELEASED FOR INFORMATION DATE : 05.10.19 REV NO:-

QUANTITY-4NOS REV NO DATE DESCRIPTION DRWN CHKD APPD


PRELIMINARY TENDER SCALE
SHEET SIZE
: 1:30
: A1
R0
APPROVAL CONSTRUCTION
ALL DIMENSIONS ARE IN MM UNLESS SPECIFIED
8 7 6 5 4 3 2 1