R EBAR T IPS
by Greg Casorso
tool. The tool is readily available at hold rebar off the ground or away from
most concrete supply stores, also for the forms, we use concrete spacer
about $350. blocks called “dobies” (Figure 3).
Bending. We bend #3 and #4 bar on Dobies come in many sizes: 1 inch,
site with the bending tool, but the 2 inch, 3 inch, and larger. Three-inch
larger sizes are practically impossible to dobies are the most common, because
work on site. I always order the larger 3-inch concrete coverage is the
sizes bent by the supplier and delivered industry standard.
to the site ready for installation. Never Tying. Rebar should be tied together
bend rebar by heating it with a torch with tie wire at every intersection
— this makes the steel brittle and easy (Figure 4, next page). The wire is
to break, defeating its structural wrapped around the bars and twisted just
purpose of resisting flex. like the tie wrap on a loaf of bread. The
Placing. Rebar has to be buried at rebar should be held in place firmly and
least 3 inches deep in the concrete securely by the tie wire — on larger walls
unless otherwise specified. Good we tie the rebar so securely that we can Figure 3. Concrete “dobies" are used to
concrete cover is essential — otherwise actually climb up the bars. hold rebar off the ground or away from
water will get to the rebar, rust the Tie wire comes in rolls, or in forms, ensuring adequate concrete coverage
steel, and eventually cause failure. To bundles of precut lengths. We like to and preventing rust.
JLC • JULY 1994
Contents Home Search Results
Figure 4. The author ties the rebar at every intersection. Precut wire can be bought in bundles
and twisted with a special swiveling tool (top right), but the author’s crew prefers to use a pair
of spring-loaded linesman’s pliers and a roll of wire on a spool (right).
use the roll-type that comes on a release agents on the forms before and allows a better concrete-to-rebar
special spool that can be worn on a placing the rebar, but don’t get any bond. But don’t rest the vibrator head
work belt. The spool conveniently release agent on the rebar, or the on the rebar. That causes the rebar to
dispenses the tie wire as needed concrete won’t bond to the steel as well. pulsate and reduces the bond between
without tangles. We tie the wire with Use a mechanical vibrator to work the concrete and the rebar.
special spring-loaded linesman’s pliers the concrete in and around the rebar. Safety. Exposed rebar ends are very
that gently open by themselves, Pay special attention to corners, dangerous. There is a very real risk of
making it easy to grasp, wrap, twist, where there is often lots of rebar. The falling on the sharp steel. A man was
and cut. vibrator works air out of the concrete killed recently in my area when he
Installers who work with precut tripped and fell from a grade beam
bundles of looped wire use a special form. He didn’t fall from a height —
tool that twists the wire up with a few he just tripped and fell down, and a
snaps of the wrist. I’ve found that this piece of rebar punctured his heart.
is an efficient method if you have acres OSHA now requires that all rebar
of slab to tie, where there are a lot of ends be covered with high-visibility
intersections that are easy to get at. plastic safety caps (Figure 5). This is
But the reel-and-pliers method is more one rule that I strongly support. It is
versatile for smaller jobs because it’s worth making the effort to train
good for working in tight spaces. people to put those caps on, and to be
Splicing. Be sure to splice the rebar aware of the risk. We take the caps
as specified by the engineer. For off when the concrete gets poured,
example, if you are using #4 bar and and caps come off by accident, too.
the engineer calls for splices of 28 bar At any given time, there are probably
diameters, then you know that you some exposed ends around. I just try
need at least a 14-inch overlap when to stay continuously vigilant, and
two bars are spliced together. The make sure my workers remember to
overlap should be tied with wire in at put the caps on and keep them on. ■
least two places.
The pour. When you place the Figure 5. The exposed ends of rebar can Greg Casorso is the owner of Casorso
concrete, make sure that it fills in cause fatal accidents. OSHA regulations call Construction, in Lafayette, Calif.,
completely around the rebar and bonds for rebar ends to be covered with high- specializing in foundation construction,
to the steel tightly. You should spray visibility protective caps. repair, and drainage.
JLC • JULY 1994