ITT SAUDI COMPANY

Vendor Document No.: GD00A907‐1‐4‐PUMP‐D‐0312


REV DATE CHECKED
JOB: 032239
BI-10-00640-0001 A 13-Jan-22 RMM
B 12-May-22 RMM
CONTRACTOR PO No. 1368870
DWG/SPEC. N° A98-MB-D-1336030
Vendor Order Number 804994

{QRCODE} SAUDI ARABIAN OIL COMPANY


COMPANY
PURCHASE ORDER NUMBER
CRIK 030 002 B
A98 31 E099-DA

PREFIX PLANT CLASS INCREMENT SEQUENCE SHT NO. REV. NO.

BERRI DEVELOPMENT PKG 01


CENTRIFUGAL PUMPS (API 610)

GENERAL ARRANGEMENT DRAWING FOR 2ND STAGE


DESALTER RECYCLE WASH WATER PUMPS A98-G-0104
A/B & A98-G-0204 A/B
NMR: "7902-601.1, 7902-602.1"
032239 – Berri Increment Program - PKG-01
Expand Abu Ali Crude & KGP Gas Facilities
Expansion
DOCUMENT STATUS SIGNED DATE
A- Reviewed with no comments
B- Reviewed with comments as noted.
C- Rejected. Do not proceed with fabrication
IO- Received for information only
SCF- Supplier Certified Final
CONTRACTOR’s review of Vendor Deliverables shall not relieve
VENDOR from its responsibility or liabilities under the Purchase
Order and Material Requisition

B ISSUED FOR APPROVAL RMM CMC RMC 12-May-22

A ISSUED FOR REVIEW RMM CMC RMC 13-Jan-22

Rev. Description Prepared Checked Approved Date

This document has been prepared by Saipem Spa for Aramco Overseas Company/Saudi Aramco.
It contains information that is Confidential and such information is intended to be for the exclusive use of the individual or entity named above.
It shall be neither shown to third parties nor used for purposes other than those for which it has been disclosed. Page 1 of 1
X (mm) Y (mm) Z (mm)
CONNECTION TABLE
CENTER OF GRAVITY
COORDINATE
1098 908 225 NO SIZE TYPE QTY. PURPOSE MATERIAL STATUS FOR USE BY
SN 6" ASME CLASS 300# RF B16.5 1 SUCTION NOZZLE ASTM A995 Gr.5A COVERED PURCHASER
DN 3" ASME CLASS 300# RF B16.5 1 DISCHARGE NOZZLE ASTM A995 Gr.5A COVERED PURCHASER
CD 3/4" ASME CLASS 300# RF B16.5 1 PUMP CASING DRAIN UNS N06625 COVERED PURCHASER
BD 2" ASME CLASS 150# RF B16.5 1 BASEPLATE DRAIN ASTM A105 OPEN PURCHASER WEIGHTS ARE APPROXIMATE
ITEM LBS KG
N1 RBE 08.7253 QUICK COUPLING (STAEUBLI RBE08) 1 FILLING CONNECTION ASTM A182 F316L QUICK COUPLING PURCHASER
PUMP 655 298
N2 3/4" ASME CLASS 600# RF B16.5 1 VENT FOR COOLER (PLAN 53B) ASTM A182 F316L COVERED PURCHASER
COUPLING 13.88 6.3
N3 3/4" ASME CLASS 600# RF B16.5 1 DRAIN FOR COOLER (PLAN 53B) ASTM A182 F316L COVERED PURCHASER
DRIVER 1144.2 519
N4 1/4" BSP-MALE 1 ACCUMULATOR N2 PRE-CHARGE ASTM A182 F316L COVERED PURCHASER PLAN 53B 1323 600
2200 N5 1/2" NPT-FEMALE 1 ACCUMULATOR DRAIN (PLAN 53B) ASTM A182 F316 COVERED PURCHASER BASEPLATE 107619 48815
N6 3/4" ASME CLASS 600# RF N16.5 1 FILLING CONNECTION (FOR ATU) ASTM A182 F316L COVERED PURCHASER TOTAL 110755 50238.5
152.4 947.6 947.6 152.4
N7 3/4" ASME CLASS 600# RF N16.5 1 INTERCONNECTING PIPING LOW POINT DRAIN ASTM A182 F316L COVERED PURCHASER ALLOWABLE NOZZLE LOADS

76.2 TYP. DIM ?? DIM ??


38 Z
Disch
TYP. ALLOWABLE NOZZLE SHALL BE 2* API610
as PER 001-GA-E-0166001 - SPECIFICATION FOR PIPING STRESS ANALYSIS
INTERCONNECTING PIPING & DRAIN X Y Shaft
328.5 FOR PLAN 53B (BUTT WELDED) Z CL
DIM ?? MATERIAL:
ASTM A312 TP 316L (PIPE)

DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.


ASTM A182 F316L (FITTINGS)
N6 X Y
+1 Suct
1589.5
0
SUCTION DISCHARGE
N3 FORCE
lbf (N) lbf (N)

BASEPLATE Fx 699 3110 240 1070


(2300 ) Fy 560 2490 200 890
Fz 461 2050 299 1330
DIM ?? 477 PIPE SUPPORT Fr 1007 4480 434 1930
SUCTION DISCHARGE
PUMP & MOTOR BEVELLED WASHER MOMENTS
1295 FOR ANCHOR BOLT
ft-lbf (N-M) ft-lbf (N-M)
193 Mx 517 2300 213 950
LIFTING LUG My 265 1180 106 470
(673 ) +1
635.5 _4x
0 Mz 396 1760 162 720

SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS


TRICO OILER DN Mr 704 3130 288 1280
BD
SN COUPLING SPECIFICATIONS
3/4" LEVELLING
MFR : JOHN CRANE (METASTREAM) SIZE: TSKS-0055
SCREWS _8x BD CASING DRAIN
⌀28 (SOCKET WELDED)
Y 38 CD TYPE: FLEXIBLE SPACER
COUPLING GUARD N7 96 X
O
TYP. EARTHING LUG MATERIAL: GUARD PROVIDED: YES X NO
ANCHOR BOLT (NON-SPARKING
ORIGIN OF DIAGONALLY PIPE-UNS N06625
-6x w/ HINGED DOOR MATERIAL: ALUMINUM w/ HINGED DOOR (NON-SPARKING)
CoG CONNECTED_2x FITTINGS-UNS N06625
848.6 MECHANICAL SEAL SPECIFICATIONS
MFR : EAGLEBURGMANN
TYPE : DUAL - PRESSURIZED
API PLAN : PLAN 53B
DRIVER SPECIFICATIONS
MFR. : TECO
N2
POWER: 100hp(74.6KW) FRAME: 405TS
PHASE: 3 RPM : 3600
874 173 HERTZ: 60 VOLTS: 460
N4 DIM ??
ENCLOSURE : SAFE AREA
ROTATION
MODEL: 3700 GROUP: MX
SIZE : 3X6 -11L
189
915 LUBRICATION: FLOOD OIL
BEARING ARRANGEMENT: OH2

DN 193 N1 BASEPLATE : FABRICATED STEEL EXTENDED HEAVY DUTY


2546 ITT SAUDI SO No. : 804994
206.7

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF
2362 END USER
CUSTOMER
:
:
SAUDI ARAMCO
SNAMPROGETTI E &C CO. LTD
CUSTOMER P.O. No. : 1368870
INTERCO SERIAL No. : GI03A725-1-4
ITT SAUDI SERIAL No.: GD00A907-1-4

SN N6 PUMP ITEM No. : A98-G-0104 A/B, A98-G-0204 A/B

324 1758 PUMP SERVICE : 2nd STAGE DESALTER RECYCLE WASH WATER PUMPS

DRAWING SCALE: DIMENSIONS IN MILLIMETERS

DRAWN CHECKED APPROVED COPYRIGHT


N5 DLK RMM 2021
CD 73 496 REVISION VALIDATION
842.4
N3
THIS REVISION NO 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

169 10-00640-0001-094
700
TOG 100.380MM
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)

279 346 ENGG./DATE


DLK
CERTIFIED BY/DATE CONST. AGENCY/DATE
RMM
OPERATIONS/DATE BY/DATE

(150 ) 110 11/10/2021 11/10/2021


REV.NO. DATE REVISION DESCRIPTION

REFERENCE DOCUMENT A 11/10/2021 ISSUED FOR REVIEW

JOB ORDER/EWO NO.


Z THIS REVISION IS NOT TO BE USED FOR
(2225 ) 1368870
DIM ??
X
O
MOTOR OUTLINE DRAWING : A98-MB-D-1336026 Z
CONSTRUCTION UNTIL CERTIFIED AND DATED

DETAIL-A BASEPLATE SAMPLING PUMP DATASHEET : A98-MB-E-1336027 O


Y SAUDI ARABIAN OIL COMPANY
ORIGIN OF PUMP CROSS-SECTION : A98-MB-D-1336028 (2463 )
DRIP-PAN BOTTLE
DRAWING TYPE

CoG SEAL DRAWING : A98-MB-D-1336029


GENERAL ARRANGEMENT DRAWING GAD
SLOPE 1:120 (MIN.) PIPING DRAWING : A98-MB-D-1336031 ORIGIN OF EARTHING LUG DETAILS TYPICAL ANCHOR BOLT INSTALLATION NOTES A98-G-0104 A/B, A98-G-0204 A/B
2nd STAGE DESALTER RECYCLE WASH WATER PUMPS
S

CoG EL
6.35

MOTOR DATASHEET : A98-MB-E-1336032


N THICK

BERRI GOSP-6
76.2

AN 1 FLANGES CONFORM TO ANSI STANDARDS. BOLT


GROUTING

CEMENTITIOUS
44.45
CH
15.875 CLEARANCE
25 MM NON SHRINK
TYP CEMTENTITOUS GROUT

SE HOLES STRADDLE q .(B16.5 STEEL)


COUPLING DRAWING : A98-MB-D-1336034 BA LIFTING LUG

122
2 ROTATION CCW VIEWED FROM COUPLING END.
ABU ALI SAUDI ARABIA
CAVITY FILLING
3/4"JACK BOLTS

460
AB-2-M20-460-(2)
152.4

(BY PURCHASER)

INSTALLATION & OPERATION MANUAL : A98-MB-E-1336037


FOUNDATION
3 DIMENSIONAL TOLERANCE TO PIPED CONNECTIONS
114.3

414
BOLT HOLES
28mm DIA.

ROUNDED
76 IS # 0.50 (13) EXCEPT FOR PUMP SUCTION AND DISCHARGE. PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
CORNERS 150x150
50mm RAD. 150 SQUARE AREA FOR
4 ROUTING OF PIPELINES IS APPROXIMATE AND MAY
A A98-MB-E-1336036
ANCHOR BOLT GROUTING

A98 001 A
SQUARE
AREA (BY PURCHASER)

VARY AFTER ASSEMBLY.


Detail "A" EARTHING LUG
(ALL DIMESIONS ARE IN "mm"
ANCHOR BOLT BY OTHERS
(ARAMCO STANDARD DWG. NO.:AA-036322)

- Saudi Aramco 5994 ENG. (09/03)

JOB 1368870 CONFIDENTIAL SMART CADD-05