DESIGNED BY

OWNER NAME RESIDENCE : ADDRESS


LOGO
19.08 KW DC ROOF MOUNTED PHOTOVOLTAIC SYSTEM
xxx

EQUIPMENT SUMMARY :
ADDRESS
53 NO'S - HELIENE 72M 360W MODULES
53 NO'S - ENPHASE IQ7+ MICRO INVERTERS
SHEET INDEX :
PE SEAL
T-01 COVER SHEET AREA
G-01 GENERAL NOTES
PV-01 ROOF MAP & PROPERTY LAYOUT
PV-02 PV LAYOUT
PV-03 STRING LAYOUT
PV-04 ATTACHMENT DETAILS
PV-06 ELECTRICAL THREE LINE DIAGRAM INSTALLER:
XXX
PV-07 ELECTRICAL CALCULATION XXX
PV-08 SYSTEM LABELING DETAILS
PV-09 EQUIPMENT SPEC SHEET VICINITY MAP

OWNER:
XXX
XXX

ROOF AREA COVERAGE


ROOF AREA IN SQ.FT : 1734
0 M/D/YY INITIAL SBMTL

ARRAY AREA IN SQ.FT : 1113 REV DATE DESCRIPTION

JOB XXX
ARRAY AREA IN % : 64% ID
CHK'D XXX
BY
DRWN XXX
BY
PRJ. XXX
ENGR

OWNER : INSTALLER : PERMIT SET

SHEET TITLE :

XXX XXX TITLE SHEET


XXX XXX SINGLE FAMILY RESIDENCE SHEET NO T-01

PAGE NO 01 of 15
ELECTRICAL CONSTRUCTION GENERAL NOTES: DESIGNED BY

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC (NATIONAL ELECTRIC CODE), NFPA (NATIONAL FIRE PROTECTION 28. PROVIDE SIGNAGE ON ALL ELECTRIC PANELS TO KEEP THE SPACE 36" IN FRONT OF THE PANELS FREE OF OBSTRUCTIONS.
ASSOCIATION), AND ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, LAWS AND REGULATIONS.
LOGO
29. PROVIDE WARNING LABEL ON ALL PANELS "WARNING, ELECTRICAL ARC FLASH HAZARD, PERSONAL PROTECTION, EQUIPMENT REQUIRED, FAILURE TO
2. ALL WORK SHALL CONFORM TO APPLICABLE STATE AND FEDERAL SAFETY CODES INCLUDING OSHA. NO 'HOT' WORK IS AUTHORIZED. ALL 'HOT WORK COMPLY CAN RESULT, IN INJURY OR DEATH, REFER TO NFPA 70E."
SHALL BE APPROVED IN WRITING WITH THE GENERAL CONTRACTOR AND OWNER. xxx

30. UPDATE PANEL BOARD DIRECTORY AS CIRCUITS ARE INSTALLED. PREPARE NEW TYPE WRITTEN PANEL SCHEDULES.
3. WORK UNDER THIS CONTRACT SHALL INCLUDE, BUT NOT BE LIMITED TO, FURNISHING, INSTALLING AND CONNECTION OF ALL ELECTRICAL EQUIPMENT
AND TESTING OF ALL SYSTEMS AND SUB-SYSTEMS WITHIN THE SCOPE OF THIS CONTRACT. ANY ERRORS, OMISSION, OR UNCERTAINTY SHALL BE
31. ALL EXTERIOR EQUIPMENT SHALL BE IN WEATHERPROOF (NEMA 3R) ENCLOSURES. ALL NEW WIRING SHALL BE IN CONDUIT, SUITABLE FOR SUN
BROUGHT TO THE ATTENTION OF THE PRIME CONTRACTOR AND OR OWNER PRIOR TO CONSTRUCTION.
EXPOSURE AND WET LOCATIONS. FIELD APPLIED COATING ARE NOT ACCEPTABLE. ADDRESS
4. COORDINATE ALL WORK WITH ARCHITECTURAL, MECHANICAL AND STRUCTURAL DRAWINGS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING
32. DC SOLAR POWER SHALL BE NEGATIVELY GROUNDED.
ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. SHALL BE IN CONTACT WITH ANY ELECTRICAL EQUIPMENT.

33. ALL MARKING SHALL BE PER CODE REQUIREMENTS.


5. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY AND SECURITY OF THE WORKSITE. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS. 34. INVERTERS MUST COMPLY WITH UL 1741 TO PREVENT ISLANDING ON POWER FAILURE. THE INVERTER SHALL PUT NOT POWER ON TO THE GRID IF THE
GRID IS OFF-LINE.
6. DO NOT SCALE DRAWINGS. LARGER SCALE DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. SPECIFICATIONS HAVE PRECEDENCE
OVER DRAWINGS. NOTIFY THE PRIME CONTRACTOR IMMEDIATELY AFTER DISCOVERY OF ANY DISCREPANCY BETWEEN DRAWINGS, SPECIFICATIONS OR 35. NOTHING IN THESE PLANS SHALL BE CONSTRUED TO CONTRADICT NEC, UL OR LOCAL CODES.
FIELD CONDITIONS. PE SEAL
36. ALL SYSTEM COMPONENTS (MODULES AND INVERTERS ETC) SHALL BE UL LISTED. AREA
7. NOTIFY THE PRIME CONTRACTOR OR OWNER IMMEDIATELY AFTER DISCOVERING ANY HAZARDOUS MATERIAL.
37. MOUNT TO ROOF USING UL APPROVED MOUNTING HARDWARE. FOLLOWING MANUFACTURERS DIRECTIONS. MOUNTING HARDWARE EVERY 4' ON
8. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. VERIFY THE EXACT LOCATIONS AND CENTER UNLESS OTHERWISE NOTED.
CONDITIONS OF ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS PRIOR TO ANY WORK. LOCATIONS FOR EQUIPMENT SHALL BE TAKEN FROM THE
OTHER SHEETS WHERE THEY OCCUR. EXTEND WIRING FROM ALL JUNCTION BOXES, CONTROL PANELS, PUMPS, RECEPTACLES, SWITCHES, ETC. AND MAKE
38. MARK ALL DC CONDUIT "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED". MARK ALL DISCONNECTS INCLUDING DISCONNECTS INCLUDED IN
ALL FINAL CONNECTIONS TO EQUIPMENT AS REQUIRED.
INVERTERS WITH "CAUTION: SOLAR CIRCUIT DISCONNECT". MARK THE MAIN SERVICE WITH "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED". USE
DURABLE MARKING WITH 3/8" WHITE LETTERS ON RED BACKGROUND.
9. THE INTENT OF THESE DRAWINGS IS FOR A COMPLETE ELECTRICAL SYSTEM. ANY ERRORS OR UNCERTAINTY SHALL BE BROUGHT TO THE ATTENTION
OF THE PRIME CONTRACTOR AND ENGINEER AS SOON AS FOUND.
39. MARK THE NEC REQUIRED CLEAR SPACE ON THE FLOOR IN FRONT OF ALL DEVICES BEING INSTALLED.

10. THE COMPLETE ELECTRICAL INSTALLATION SHALL BE TESTED AS A COMPLETE WORKING SYSTEM.
40. SUPPORT ALL ROOF MOUNTED CONDUIT WITH FOAM 'SLEEPERS' IN UL APPROVED SYSTEM. INSTALLER:
11. RESTORE ALL DAMAGES RESULTING FROM WORK AND LEAVE PREMISES IN CLEAN CONDITION WHEN FINISHED WITH WORK.
41.OBTAIN THE BEST INFORMATION ON UNDERGROUND UTILITIES IN AREAS BEING TRENCHED. USE 'DIG ALERT' OR OTHER LOCATING SERVICE BEFORE XXX
DIGGING.
12. ALL TYPES OF SWITCHES, RECEPTACLES, WALL PLATES AND LIGHTING FIXTURES SHALL BE AS APPROVED BY PRIME CONTRACTOR OR OWNER. VERIFY XXX
MATERIALS AND COLOR AND LOCATIONS, SUBMIT CATALOG CUTS OR SHOP DRAWINGS FOR ALL MATERIALS AND EQUIPMENT.
42.SOLAR PANELS SHALL NOT BE INSTALLED OVER ANY PLUMBING OR MECHANICAL VENTS, EXHAUSTS OR CHIMNEYS.

13. ALL ITEMS ARE NEW UNLESS NOTED AS EXISTING (E).


43.REMOVAL OF INVERTER, METER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE
CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR.
14. REMOVE ALL INDICATED ITEMS. REMOVE ALL EXPOSED CONDUITS. REMOVE WIRES TO NEAREST CONCEALED JUNCTION BOX OR PANEL. ABANDON IN
PLACE EXISTING UNUSED CONCEALED CONDUITS NOT EXPOSED BY CONSTRUCTION.
44.All PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE, AND ACCESS BY UNQUALIFIED PERSONS.

15. ALL EQUIPMENT SHALL BE SECURED IN ACCORDANCE WITH GOVERNING SEISMIC REGULATIONS. PROVIDE EXPANSION AND DEFLECTION FITTINGS IN
OWNER:
45.NO PLASTIC ZIP TIES
CONDUITS REQUIRED BY NEC. XXX
16. FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED SURFACES. SEE DETAIL D/E5. XXX
STORM WATER PREVENTION NOTES:
17. PROVIDE GROUND ROD, GROUNDING ELECTRODE AND BONDING FOR ALL SERVICE ENTRANCE EQUIPMENT, BUILDING STRUCTURAL STEEL, COLD
STORM WATER POLLUTION PREVENTION DEVICES AND PRACTICES SHALL BE INSTALLED AND/OR INSTITUTED AS NECESSARY TO ENSURE COMPLIANCE
WATER PIPE AND TRANSFORMER PER NEC 6' MIN. APART.
WITH THE CITY WATER QUALITY STANDARDS CONTAINED IN LOCAL REGULATIONS, FEDERAL REGULATIONS AND ANY EROSION CONTROL PLAN ASSOCIATED
18. ALL NEW CIRCUIT BREAKER SHALL BE RATED 10,000 AIC OR HIGHER UNO. WITH THIS PROJECT. ALL SUCH DEVICES AND PRACTICES SHALL BE MAINTAINED, INSPECTED AND/OR MONITORED TO ENSURE ADEQUACY AND PROPER
FUNCTION THROUGHOUT THE DURATION OF THE CONSTRUCTION PROJECT.
19. ALL CONDUITS SHALL BE EMT, INTERMEDIATE METAL CONDUIT, OR RIGID STEEL. MINIMUM SIZE SHALL BE 1/2". ALL CONDUIT, BOXES AND ELECTRICAL
FITTINGS SHALL BE STEEL.
COMPLIANCE WITH THE WATER QUALITY STANDARDS AND ANY EROSION CONTROL PLAN ASSOCIATED WITH THIS PROJECT INCLUDES, BUT IS NOT LIMITED
20. DO NOT USE THE WORKING SPACE WITHIN ANY EXIT SIGN OR ASSOCIATED JUNCTION BOX FOR ANY OTHER CIRCUIT. TO THE FOLLOWING:

21. PROVIDE EXPANSION AND DEFLECTION FITTINGS IN CONDUITS CROSSING BUILDING EXPANSION AND SEISMIC JOINTS. SEE DETAIL E/E5. 0 M/D/YY INITIAL SBMTL
1. ALL POLLUTANTS SHALL BE RETAINED ON SITE UNTIL PROPERLY DISPOSED OF, AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW,
REV DATE DESCRIPTION
22. PROVIDE JUNCTION AND/OR PULL BOXES WHEN NECESSARY OR REQUIRED BY NEC. SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES OR WIND.
JOB XXX
ID
CHK'D XXX
23. ALL CONDUCTORS SHALL BE COPPER, THHN, #12 AWG MINIMUM. UNLESS IN A WET LOCATION IN WHICH CASE THWN SHALL BE USED. 2. STOCKPILES OF CONSTRUCTION-RELATED MATERIALS SHALL BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY FORCES OF WIND OR BY
DRWN XXX
WATER FLOW. BY
24. INSTALL GREEN INSULATED GROUND WIRE IN ALL CIRCUITS. SIZE PER NEC REQUIREMENTS OR THE SAME AS PHASE CONDUCTORS WHICH EVER IS PRJ.
LARGER. UNLESS INDICATED OTHERWISE. XXX
ENGR
3. TRASH AND CONSTRUCTION SOLID WASTES SHALL BE DEPOSITED INTO COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND
25. ALL NEW WIRING, CONDUIT, AND JUNCTION BOXES SHALL BE CONCEALED WITHIN NEW WALLS, CEILINGS OR FLOOR SPACES. SURFACE MOUNT
DISPERSAL BY WIND. PERMIT SET
CONDUIT ON OLD WALLS AND CEILINGS. RUN ALL SURFACE RACEWAY TIGHT TO STRUCTURE, PARALLEL TO BUILDING LINES.

26. PAINT ALL EXPOSED ELECTRICAL CONDUITS AND BOXES, PATCH AND PAINT ALL SCUFF MARKS AND/OR DAMAGE RESULTING FROM CONSTRUCTION.
SELECT NEW PAINT COLOR TO MATCH EXISTING PAINT COLOR. VISIBILITY FROM ADJACENT PROPERTY: SHEET TITLE :

GENERAL NOTES
27. NO FOREIGN EQUIPMENT SHALL BE LOCATED WITHIN THE SPACE ABOVE OR BELOW ELECTRIC PANELS 1. THE SOLAR PANELS MAY BE VISIBLE FROM ADJACENT PROPERTIES. PAINT ALL STRUCTURAL ELEMENTS TO MATCH THE EXISTING ROOFING.

SHEET NO G-01
PAGE NO 02 of 15
DESIGNED BY

LOGO

xxx

ER
TY
LIN
ADDRESS
OP
PR

PE SEAL
AREA

DR
IV
E
W
AY
23 NO'S ICR
08 H M

WI

AZ 360 INV
T

IM W
UT M ERT
N

H, OD ER
TIO

O
JB
ER

TIL UL
NC NT
JU X CE

T2 E
D T L
BO OA NC NE Y


L ON PA WA
SC E LK
DI V IC
R WA
AC SE
R
TE
MA
IN
TY
ME
INSTALLER:

LC
ILI

AC
U T

D
MS
XXX

P
ME
T
XXX

23 NO'S ICR
13 TH M

WI

AZ 360 INV
IM W
UT MO ERT
Y DR
WA

H,
O

O
LK CC

TIL DUL R
WA O
SIR

DR
T2 E

IV

E
E

W
AY
14 NO'S ICR
32 TH M

WI

AZ 360 INV
IM W

OWNER:
UT M ERT
H, OD ER
O

TIL UL

XXX
T2 E

XXX

DR
AY CO
KW OC
WA
L SIR

Y
WA
LK
WA
0 M/D/YY INITIAL SBMTL

REV DATE DESCRIPTION


DR
CO JOB XXX
OC ID
SIR
CHK'D XXX
Y
WA BY
LK DRWN
WA XXX
BY
PRJ. XXX
ENGR

N
PERMIT SET

SHEET TITLE :

PROPERTY
LAYOUT

SHEET NO PV-01
PROPERTY LAYOUT
PAGE NO 03 of 15
DESIGNED BY

LOGO

xxx

ADDRESS

PE SEAL
AREA
23 NO' ICR
08 TH M
9° S 3 O
WI

AZ 60 INV
IM W

INSTALLER:
UT MO ERT
H,

XXX
TIL DUL R

XXX
T2 E

N
JB IO ER

T
NC T
E

U
J X C EN
D T L
BO OA NC NE
L O N A
P
SC E
DI V IC
AC R R OWNER:
SE E TE
IN M XXX
MA TY

LC
I L I XXX

AC
UT

D
MS
P
ME
T
14 NO' ICR

23 NO' ICR
32 TH M

13 TH M

WI

9° S 3 O
WI
AZ 360 INV

AZ 60 INV
IM W
S

IM W
UT M ERT

UT MO ERT
H, OD ER

H,
O

TIL UL

TIL DUL R
T2 E

T2 E

0 M/D/YY INITIAL SBMTL


E
REV DATE DESCRIPTION

JOB XXX
ID
CHK'D XXX
BY
DRWN XXX
BY
PRJ. XXX
ENGR

N PERMIT SET

SHEET TITLE :

PV LAYOUT

SHEET NO PV-02
PV LAYOUT
PAGE NO 04 of 15
DESIGNED BY

LOGO

xxx

ADDRESS

E1

E2

E3

PE SEAL
AREA
E4

E5

C2

C3
E6

C4
23 NO' ICR
08 TH M
9° S 3 O
WI

E7

C1
AZ 60 INV
IM W
UT MO ERT

C5
INSTALLER:
H,

E8

XXX
TIL DUL R

C6
XXX
T2

C9 N
JB IO R

T TE
NC
E

0
E

C1 N
D1
U
J X CE T
BO D L
C7 A NC NE
D4 C8
LO O N
P A
SC CE
D5 1 A1
DI I
C1
AC RV R OWNER:
D8 D2 SE E TE
A2 I N M XXX
MA ITY

LC
D9 D3
B3 I L XXX

AC
UT
0
D1

D
D6 A3
B2

MS
0
E1

P
D7

ME
B4
A4

T
E9 1 B1
B1
14 NO' ICR
32 TH M

WI

23 NO' ICR
0
B1

13 TH M
B5
AZ 360 INV

A5

9° S 3 O
1

WI
A1
IM W

B9
S

AZ 60 INV
UT M ERT

IM W
B8 B6 0 A6
H, OD ER

A1

UT MO ERT
O

TIL UL

H,
T2 E

TIL DUL R
A9 A7
B7

T2 E
0 M/D/YY INITIAL SBMTL


REV DATE DESCRIPTION
A8

E
JOB XXX
ID
CHK'D XXX
BY
DRWN XXX
BY
PRJ. XXX
ENGR

N PERMIT SET

SHEET TITLE :

STRING
LAYOUT

STRING LAYOUT SHEET NO PV-03


PAGE NO 05 of 15
DESIGNED BY
Roof Cover Type : Shingle Roof
LOGO
Rafter Size with O.C : 2" X 4" @ 24"
Attachment Spacing : 6'
xxx
No. of Attachment Points : 86

ADDRESS

PE SEAL
AREA
23 NO' ICR
08 TH M
9° S 3 O
WI

AZ 60 INV
IM W
UT MO ERT
H,
TIL DUL R

INSTALLER:
T2 E

N
2'

JB IO

T
NC XXX
E

JU X
BO XXX

OWNER:
XXX
14 NO' ICR

23 NO' ICR
32 TH M

13 TH M

WI

XXX
9° S 3 O
WI
AZ 360 INV

AZ 60 INV
IM W
S

IM W
PV MODULE
UT M ERT

UT MO ERT
H, OD ER

H, END CLAMP
O

TIL UL

TIL DUL R
T2 E

T2 E

SNAP N RACK

E

ULTRA RAIL UR-40


ROOF PENETRATION POINTS

RAILS ROOF SNAPNRACK ULTRA


FOOT ASSEMBLY
0 M/D/YY INITIAL SBMTL

REV DATE DESCRIPTION


HANGER BOLT
JOB XXX
5
16"x Min Embedment 3"
ID
CHK'D XXX
BY
Reference Weights DRWN XXX
BY
Module SF 20.83 SF PRJ. XXX
Module Weight 46.30 LBS ENGR

Module Loading 2.52 LBS/SF


Mounting Weight 1 LBS approx. PERMIT SET
Total Weight 3.52 LBS/SF N
Code Limit 4LBS/SF SHEET TITLE :

Site Data Module LBS ATTACHMENT


Home 53 2453.90 LAYOUT

ATTACHMENT DETAILS SHEET NO PV-04


ATTACHMENT LAYOUT
PAGE NO 06 of 15
DESIGNED BY

LOGO

xxx

UTILITY SERVICE

ADDRESS

M UTILITY METER
PV ARRAY (N)
53 NO'S OF HELIENE 360W MODULES CONNECTED TO INDIVIDUAL
ENPHASE IQ7PLUS MICRO INVERTER AND OUTPUT COMBINED THROUGH TRUNK CABLE POINT OF
BRANCH CIRCUIT CONTAINING 11 MODULES AND 11 MICRO-INVERTERS INTERCONNECTION
AC BRANCH END CABLE Supply side connection
1st 10th 11th BLACK - L1
(360W) Module 02 to 09 Modules (360W) Module (360W) Module as per 705.12(A) PE SEAL
RED - L2
O/P combined AC DISCONNECT (N) AREA
through trunk cable
100A Rated, (2) 90A Fuses
Fused Metallic

ENPHASE IQ7+

Branch End Cap JB (N)


Installed on the 1-53 INVERTER
Open AC Connector 200A
20A
4 4
20A INSTALLER:
BRANCH CIRCUIT CONTAINING 11 XXX
MODULES AND 11 MICRO-INVERTERS 20A XXX

20A
3

BRANCH CIRCUIT CONTAINING 11 20A


MODULES AND 11 MICRO-INVERTERS
OWNER:
MAIN SERVICE PANEL (E)
240V, 200A Rated XXX
XXX
BRANCH CIRCUIT CONTAINING 10
MODULES AND 10 MICRO-INVERTERS
LOAD CENTER (N)
240V, 125A Rated

BRANCH CIRCUIT CONTAINING 10


MODULES AND 10 MICRO-INVERTERS

0 M/D/YY INITIAL SBMTL

REV DATE DESCRIPTION


(1)#8 AWG Ground (EGC)
2 JOB XXX
ID
CHK'D XXX
BY
DRWN XXX
BY
PRJ. XXX
THREE LINE DIAGRAM ENGR

PERMIT SET

SHEET TITLE :

THREE LINE
DIAGRAM

SHEET NO PV-06

PAGE NO 08 of 15
WIRING AND CONDUIT SCHEDULE DESIGNED BY
DC SCHEDULE

Adjusted Multiple Max ONE Wire Derated NO. OF LOGO


Vmpp (V) Impp (A) Max Circuit Nominal Minimum OCPD Temperature TOTAL NO OF CURRENT
ITEM DESCRIPTION ID QTY Voc (V) ISC (A) STC Ampacity conductor WAY WIRE SIZE Ampacity Ampacity GROUND WIRE TYPE R/1000FT V LOSS % TEMP MAX CONDUIT
STC STC current (A) Power Ampacity (A) rating (A) Derate CONDUCTORS CARRYING
(A) Derate LENGTH (ft) (A) (A)
CONDUCTORS
53 48.19 39.713 9.13 9.81 12.26 360 15.3 16.3 20 1.00 0.76 3.2 30 22.8 1.98 0.29% xxx
1 MODULE HELIENE A #12 AWG #6 Bare PV 52 C 2 2 N/A
Total Nominal Power 19080 DC Drop 0.29%
AC SCHEDULE
NO. OF
QTY VOLTAGE (V) Max Circuit Current (A)
Minimum
Adjusted
Ampacity
OCPD Multiple
Temperature
Max ONE
WAY
Wire
Ampacity
Derated
Ampacity TOTAL NO OF CURRENT ADDRESS
ITEM DESCRIPTION ID Power conductor WIRE SIZE GROUND WIRE TYPE R/1000FT V LOSS % TEMP MAX CONDUIT
Ampacity (A) rating (A) Derate CONDUCTORS CARRYING
(A) Derate LENGTH (ft) (A) (A)
CONDUCTOR
MICRO INVERTER OUTPUT CONNECTED
2 B 53 240 1.21 290 1.5 1.6 NA 1.00 0.96 2 #10 AWG 40 38.4 #8 AWG THWN-2 1.24 0.00% 52 C 3 2 N/A
TO INPUT OF TRUNK CABLE
TRUNK CABLE OUTPUT TO JUNCTION BOX
(MICRO INVERTERS AC OUTPUT
3 ARRAY C 1 240 13.31 3190 16.6 35.4 20 0.50 0.96 15 #10 AWG 40 19.2 #8 AWG THWN-2 1.24 0.10% 52 C 11 10 1"PVC Min
CONNECTED PARALLEL BY USING TRUNK
CABLE) TO LOAD CENTER
LOAD CENTER TO AC DISCONNECT TO
4 D 1 240 64.13 15370 80.2 85.3 80 1.00 0.96 25 #4 AWG 95 91.2 #6 AWG THWN-2 0.308 0.21% 52 C 4 2 1 1/4"PVC Min
MAIN SERVICE PANEL
Total Nominal Power 15370 AC Drop 0.31% PE SEAL
AREA
BILL OF MATERIAL
REF. DES. QTY. MANUFACTURER MODEL NUMBER DESCRIPTION
SOLAR MODULES 53 HELIENE 72M-360 SOLAR PANEL 360 W 1000 V (UL)
NOTES: 1. TYPE-1 UL 1703 class C
INVERTER 53 ENPHASE IQ7PLUS-72-2-US INVERTER 0.29 Kw NEMA Type 6 240 V AC
NOTES: 1. UL1741, UL 1998, UL 1699B, IEE1547
2. DC INPUT WIRE RANGE (2) #12 to #2; AC OUTPUT WIRE RANGE (3) #12
MSP 1 TBD TBD MAIN SERVICE PANEL, NEMA 3R ENCLOSURE 200 A 1 Ph 240 V AC
AC DISCONNECT 1 TBD TBD AC DISCONNECT 100 A
NOTES: 1. USED AS PV UTILITY/SERVICE DISCONNECT INSTALLER:
2. LOCKABLE HEAVY DUTY SWITCH WITH VISIBLE CONTACTS, UL LISTED
ARRAY JUNCTION BOX 1 TBD TBD ARRAY JUNCTION BOX 600 V
XXX
LOAD CENTER 1 TBD TBD LOAD CENTER, NEMA 3R ENCLOSURE 125 A 1 Ph 240 V AC XXX

OWNER:
XXX
XXX

0 M/D/YY INITIAL SBMTL

REV DATE DESCRIPTION

JOB XXX
ID
CHK'D XXX
BY
DRWN XXX
BY
PRJ. XXX
ENGR

PERMIT SET

SHEET TITLE :

ELECTRICAL
CALCULATION

SHEET NO PV-07

PAGE NO 09 of 15
DESIGNED BY

DC DISCONNECT WARNING AC DISCONNECT WARNING LOGO

PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM


DC DISCONNECT AC DISCONNECT CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
WARNING xxx

INVERTER OUTPUT CONNECTION


OPERATING VOLTAGE 240 VAC FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN:

OPERATING CURRENT 64.13 Amps SOURCES : UTILITY GRID AND


PV SOLAR ELECTRIC SYSTEM
ADDRESS
WARNING "Dual Power Supply"
label NEC 690.64,705.12(4)
point of connection
ELECTRIC SHOCK HAZARD
WARNING
ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS WARNING
TERMINALS ON BOTH THE LINE AND ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
LOAD SIDES MAY BE ENERGIZED DO NOT TOUCH TERMINALS PE SEAL
TERMINALS ON BOTH THE LINE AND TERMINALS ON BOTH THE LINE AND AREA

MA A LO
IN THE OPEN POSITION
LOAD SIDES MAY BE ENERGIZED

IN C D AD
LOAD SIDES MAY BE ENERGIZED

SE IS C
PER NEC 680.14(C)(2), 680.17(4),680.54 R IC X
LA TA BO IN THE OPEN POSITION

RV CO EN
SO VOL N
IN THE OPEN POSITION TIO

IC
Per NEC 690.54 T O C
HO

E P NECER
operating voltage,operating current P JUN

N
"Don Not Touch terminals"

AN T
PER NEC 680.14(C)(2), 680.17(4),680.54 PLACE ON: Inverter Breaker Panel labels NEC 690.17(4)

EL
UT

T
if sum of breaker exceeds panel rating Switch or Circuit Breaker

ILI
TY
Per NEC 690.53
operating voltage,operating current ,max system voltage

ME
THIS ELECTRIC SYSTEM
short circuit current and maximum output current of WARNING

TE
the charge controller if one is installed IS ALSO SERVED BY A

R
INVERTER OUTPUT CONNECTION
PLACE ON : Main Solar Disconnect PHOTOVOLTAIC SYSTEM INSTALLER:
DO NOT RELOCATE
PHOTOVOLTAIC SYSTEM XXX
DISCONNECT
THIS OVER CURRENT DEVICE CAUTION: SOLAR ELECTRIC
XXX
"PV System Disconnect "
Inverter output connection *label
NEC 705.12(7)
SYSTEM CONNECTED
label NEC 690.14(C)(2) Point Of Conection N
Required Disconnect Markings MAIN SERVICE PANEL (SSC)
PHOTOVOLTAIC POWER SOURCE A GENERATION SOURCE IS CONNECTED TO THE SUPPLY (UTLITY)
SIDE OF THE SERVICE DISCONNECTING MEANS. FOLLOW PROPER
DC LABELS OPERATING AC VOLTAGE : 240 V LOCK-OUT/TAG-OUT PROCEDURES TO ENSURE THE
MAXIMUM OPERATING AC PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AC DISCONNECT PER NEC 690.17
OPERATING VOLTAGE = 240V MAX CURRENT = 64.13 A
PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH IS OPENED
PLACE ON 1.DC Junction Boxes PRIOR TO PERFORMING WORK ON THIS DEVICE
OUTPUT CURRENT : 64.13 A Must show drawing of the property and
2.DC Combiner Boxes
equipment layout .per NEC 690.56 OWNER:
WARNING XXX
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
WARNING XXX
PHOTOVOLTAIC SYSTEM ARE THIS LOAD CENTER IS DEDICATED TO PHOTOVOLTAIC
UNGROUNDED AND SYSTEM ADD NO ADDITIONAL LOADS
MAY BE ENERGIZED
"Electric Shock Hazard"
label NEC 690.35(F)
ungrounded PV system
per NEC 690.31(E)(3)
PLACE ON 1.DC Junction Boxes
2.DC Combiner Boxes

PHOTOVOLTAIC POWER
SYSTEM LABELING DETAIL:
SOURCE
WARNING
PHOTOVOLTAIC POWER SOURCE ALL PLAQUES AND SIGNAGE REQUIRED BY THE 2014 EDITION OF NEC WILL BE INSTALLED AS REQUIRED.
"PV Power Source " PLACARDS CONSIST OF WHITE LETTERING ON RED BACKGROUND WITH TEXT WRITTEN IN CAPITOL LETTERING A
Label. NEC 690.31(E)(3)
DC-PV Source Conductor MINIMUM OF 3/8” IN HEIGHT ON PLASTIC ENGRAVED PLACARDS.
0 M/D/YY INITIAL SBMTL
ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED
REV DATE DESCRIPTION
LETTERS IN A CONTRASTING COLOR TO THE PLAQUE, INCLUDE THE LOCATION OF METER, DISCONNECTS,
OTHERS INVERTER, THE ARRAY AND A FOOTPRINT OF THE ENTIRE BUILDING AND SITE. THIS PLAQUE WILL BE ATTACHED JOB XXX
ID
PLACE ON : Next GFI Reset BY POP RIVETS, SCREWS OR OTHER APPROVED FASTENERS. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV CHK'D XXX
PLACE ON:All DC Source Markings and System PLACE ON : Next to inverter interconnection "PV System Disconnect "label NEC RESISTANT. BY
Output Conductor Raceways Breaker,Load center, & Service Panel 690.14(C)(2) Required Disconnect Markings WARNING DRWN
BY
XXX
ELECTRIC SHOCK HAZARD PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND
PV SOLAR BREAKER PRJ. XXX
CAUTION SOLAR CIRCUIT PHOTOVOLTAIC SYSTEM IF GROUND FAULT IS INDICATED
ALL NORMALLY GROUNDED
SHALL BE IDENTIFIED EVERY 5 FEET -- AND WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND
BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS LABELED
ENGR

DO NOT RELOCATE EQUIPPED WITH CONDUCTORS MAY BE


"Caution Solar Circuit "Label NEC 690.4(F),690.31(E)(4) THIS OVER CURRENT
RAPID SHUTDOWN UNGROUNDED AND ENERGIZED “CAUTION SOLAR CIRCUIT” OR EQUIVALENT EXAMPLES OF ALL REQUIRED WARNING LABELS PER NEC BELOW: PERMIT SET
place on conduit every 10 feet IFC 605.11.1.1 & IFC 605 .11.2 DEVICE
*MUST BE REFLECTIVE IF INDOORS OR IN ATTIC "Ground Fault Indicated"
label Nec 690.5(C) Ground Fault Protection

MARKING PV CIRCUIT (INSTALL APPLICABLE LABELS ONLY) SIGNAGE REQUIREMENT : SHEET TITLE :

Marking is required on all interior and exterior PV conduit, raceways, enclosures, cable assemblies, and junction boxes to alert the fire service to avoid cutting them. -Red Background -Minimum 3/8” Letter Height EQUIPMENT
Marking shall be placed every 10', within 1' of turns or bends, above and/or below penetrations, and at all PV combiner and junction boxes.Reflective weather -White Lettering -All capital letters SIGNAGE
resistant material suitable for the environment
RED BACKGROUND .WHITE LETTERING. ("WARNING"-3/8"
-Arial or similar font, Non bold
(durable adhesive materials must meet this requirement) Marking Content and Format: LETTERS).ALL CAPITAL LETTERS.ARIAL OR SIMILAR FONT . WEATHER
SHEET NO PV-08
-RESISTANT MATERIAL,UL 969.
PAGE NO 10 of 15
DESIGNED BY

LOGO

xxx

ADDRESS

PE SEAL
AREA

SPEC SHEET WILL


CHANGE BASED ON THE
PROJECT REQUIREMENT
INSTALLER:
XXX
XXX

OWNER:
XXX
XXX

0 M/D/YY INITIAL SBMTL

REV DATE DESCRIPTION

JOB XXX
ID
CHK'D XXX
BY
DRWN XXX
BY
PRJ. XXX
ENGR

PERMIT SET

SHEET TITLE :

EQUIPMENT
SPEC SHEET

SHEET NO PV-09

PAGE NO 11 of 15