Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 14

STRUCTURAL ANALYSIS

DESIGN REPORT

Footing Name F1
Column Type Isolated

Design Paramters

Pu = 2237.8522 KN Factored Column Load


f'c = 249.977 Mpa Strength of Concrete
fy = 414 Mpa Strength of Steel
Embedment = 1500 mm Height of Soil above footing
Density, g = 18 KN/m3 Density of Soil
Concrete Density, g = 24 KN/m3 Density of Concrete
Qall (Soil Bearing Capacity)= 400 Kpa Allowable SBC
Trial "t" = 475 mm Assume Thickness of Footing
Increment "t" = 25 mm Rounding off Interval
Minimum "L" = 1000 mm Factored Column Load Concentric Footing
bar Ø= 20 mm bending reinforcement
Col-x = 600 mm size of column along x dir
Col-z = 600 mm size of column along z dir

REQUIRED DIMENSIONS
Ps = 1598.46586 KN Service Column Load
Footing Areareq = 4.31842728 mm2 Required Footing Area
B = 2100 mm Dimension of Footing along Z Dir

L = 2100 mm Dimension of Footing along X Dir Wide Beam Shear


Final Area = 4410000 mm2 Actual Area of Footing
Qumax= 507.45 Kpa Ultimate Soil Pressure

WIDE BEAM SHEAR øVc > Vu


øVc = ø(f'c)1/2Bd/6 Wide Beam Shear Formula
Effective, d1 = 153.23 mm Wide Beam Shear Effective Depth
t= 250 mm Wide Beam Shear Formula
Used t = 475 mm Wide Beam Shear Formula

Punching Shear
PUNCHING SHEAR CHECK

Used d = 390 mm
bo = 3960 mm
β= 1
as = 40
Punching Area = 3429900 mm2
VuPunching = 1740.50276 KN
ff'c1/2bod/3 = 6104.4962 KN Safe
Critical Area for Moment

FLEXURAL REINFORCEMENT REQUIREMENTS

d= 390 mm
Mu = 299.71 kN-m steel ratio, r = 0.0095
Rn = 1.04259122 required As = 7819.40
rrqrd = 0.00252 number of bars = 24.89
rmin = 0.0095 say = 25.00 pcs - 20 mmf Both Ways
STRUCTURAL ANALYSIS
DESIGN REPORT

USE t = 475 mm
STRUCTURAL ANALYSIS
DESIGN REPORT

Footing Name CF1


Column Type Combine Footing

Design Paramters Design Paramters

Pu1 = 362 KN Factored Axial Load Column 1


Pu2 = 443 KN Factored Axial Load Column 2
X1 = 200 mm From Edge of Column 1 to Column 1
X2 = 5200 mm From Edge of Column 1 to Column 2
f'c = 20 Mpa Strength of Concrete
fy = 275 Mpa Strength of Deformed Bars
Embedment = 1200 mm Height of Soil above footing
Density, g = 18 KN/m3 Density of Soil
Concrete Density, g = 24 KN/m3 Density of Concrete
Qall (Soil Bearing Capacity)= 173 Kpa Allowable SBC
Trial "t" = 500 mm Assume Thickness of Footing
Increment "t" = 25 mm Rounding off Interval
Minimum "L" = 1000 mm Minimum Width of the Footing
bar Ø= 16 mm bending reinforcement
Col1 = 400 mm size of column along x dir
Col2 = 400 mm size of column along z dir

FOOTING DIMENSIONS
Qp = 139.4000 Kpa Permissible Soil Pressure
Ps1 = 258.5714285714 KN Service Axial Load Column 1

Ps2 = 316.4285714286 KN Service Axial Load Column 2

X = 2951.552795031 mm
L = 5903.105590062 mm
Use L = 6000 Total Length of Combined Footing
B = 698.7543415987
Use B = 1000 mm Width of Footing or Dimension of Footing along Z Dir

Qactual = 95.83333333333 Kpa SOIL IS ADEQUATE


Final Area = 6000000 mm2 Actual Area of Footing
Qmax = 134.1666666667 Kpa

Geometric Coordinates of Strap Beam Footin


D1-2 0.4 m Distance from point 1-2
D2-3 4.6 m Distance from point 2-3
D3-4 0.4 m Distance from point 3-4
D4-5 0.6 m Distance from point 4-5

PLAN VIEW
1000

400

400.000

400 400.000

L = 2X = 6

PA - Factored = 362 ELEVATION VIEW PB - Factored = 443


PA - Service = 258.5714286 PB - Service = 316
XA-B
5.00

1 2 3 4 5
Distances (m) 0.40 4.60 0.40 0.60

7.80 -7.80
STRUCTURAL ANALYSIS
DESIGN REPORT

Net Soil Pressure


Qu = (PA+PB)/(Afooting) 134.17 kPa soil pressure
Qu = (PA+PB)/(Afooting)*B 134.17 kn/m soil pressure per meter

@ Point 1 Shear = 0 0.00 kN 0


@ Point A Shear = 0.2 26.83 kN 0
@ Point A Shear = 0.2 -327.37 kN 0
@ Point 2 Shear = 0.4 -300.53 kN 0
@ Point 3 Shear = 5.00 316.63 kN 0
@ Point B Shear = 5.2 343.47 kN 0
@ Point B Shear 5.2 -107.33 kN 0
@ Point 4 Shear = 5.4 -80.50 kN 0
@ Point 5 Shear = 6.00 0.00 kN 0

SHEAR DIAGRAM
343.47
316.63

0.00 26.83 0.00


-80.50
-107.33

-300.53
-327.37

Z1 = ? Z2= ?

Location of Max moment 2.44 From Column A

@ Point 1 Moment = 0 0.00 kN-m 0 0


@ Point A Moment = 0.2 2.68 kN-m 0.2 0
@ Max Moment = 2.44 -396.70 kN-m 2.64 0
@ Point Moment = 2.56 42.93 kN-m 5.20 0
@ Point 5 Moment = 0.8 0.00 kN-m 6.00 0
0

5.4

MOMENT DIAGRAM
42.93
0.00 2.68 0.00

-396.70

WIDE BEAM øVc > Vu


øVc = ø(f'c)1/2Bd/6 Wide Beam Shear Formula
Effective, d1 = 58.07 mm Wide Beam Shear Effective Depth
t= 150 mm Wide Beam Shear Formula
Used t = 500 mm Wide Beam Shear Formula

Z1 = 2440.00 mm
Z2 = 2560.00 mm

Vu @ distance d from Column 2


Vu2 = 308.842275
øVc = 43.2828224845 Safe

Used d = 417

øVc = 310.813448872 Safe

PUNCHING SHEAR CHECK 1

Vu @ distance d/2 from Column 2 (Interior)


STRUCTURAL ANALYSIS
DESIGN REPORT

Vu2a = 290.679781421 (Demand Punching Shear Force Based on Shear Diaghram)


Vu2b = 353.445225833 (Demand Punching Shear Force Based on Area Method)

Used d = 417 mm
bo = 3268 mm
VuPunching = 353.445225833333 KN
ff'c1/2bod/3 = 1523.60752637285 KN Safe

PUNCHING SHEAR CHECK 2

Vu @ distance d/2 from Column 1 (Edge)


Vu1a = 272.559583333 (Demand Punching Shear Force Based on Shear Diaghram)
Vu1b = 295.299779583 (Demand Punching Shear Force Based on Area Method)

Used d = 417 mm
bo = 2451 mm
VuPunching = 295.299779583333 KN
ff'c1/2bod/3 = 466.220173308706 KN Safe

FLEXURAL REINFORCEMENT REQUIREMENTS TOP BARS ALONG L

d= 417 mm
Mu = 396.70 kN-m steel ratio, r = 0.0100
Rn = 2.53484822054427 required As = 4183.16
rrqrd = 0.01003 number of bars = 20.81
rmin = 0.0051 say = 21.00 pcs - 16 mmf Both Ways
USE t = 500 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG L

d= 417 mm
Mu = 42.93 kN-m steel ratio, r = 0.0051
Rn = 0.27433422300262 required As = 2122.91
rrqrd = 0.00101 number of bars = 10.56
rmin = 0.0051 say = 11.00 pcs - 16 mmf Both Ways
USE t = 500 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG B

d= 417 mm
Mu = 36.23 kN-m steel ratio, r = 0.0051
Rn = 0.03857825010974 required As = 12737.45
rrqrd = 0.00014 number of bars = 63.35
rmin = 0.0051 say = 64.00 pcs - 16 mmf Both Ways
USE t = 500 mm
STRUCTURAL ANALYSIS
DESIGN REPORT

Footing Name CF2


Column Type Combine Footing

Design Paramters Design Paramters

Pu1 = 1238 KN Factored Axial Load Column 1


Pu2 = 1703 KN Factored Axial Load Column 2
X1 = 262.5 mm From Edge of Column 1 to Column 1
X2 = 3416.5 mm From Edge of Column 1 to Column 2
f'c = 20.7 Mpa Strength of Concrete
fy = 414 Mpa Strength of Deformed Bars
Embedment = 2500 mm Height of Soil above footing
Density, g = 18 KN/m3 Density of Soil
Concrete Density, g = 24 KN/m3 Density of Concrete
Qall (Soil Bearing Capacity)= 201 Kpa Allowable SBC
Trial "t" = 500 mm Assume Thickness of Footing
Increment "t" = 25 mm Rounding off Interval
Minimum "L" = 1000 mm Minimum Width of the Footing
bar Ø= 25 mm bending reinforcement
Col1 = 525 mm size of column along x dir
Col2 = 525 mm size of column along z dir

FOOTING DIMENSIONS
Qp = 144.0000 Kpa Permissible Soil Pressure
Ps1 = 884.2857142857 KN Service Axial Load Column 1

Ps2 = 1216.428571429 KN Service Axial Load Column 2

X = 2088.83866032 mm
L = 4177.677320639 mm
Use L = 4250 Total Length of Combined Footing
B = 3491.962765703
Use B = 3750 mm Width of Footing or Dimension of Footing along Z Dir

Qactual = 131.8095238095 Kpa SOIL IS ADEQUATE


Final Area = 15937500 mm2 Actual Area of Footing
Qmax = 184.5333333333 Kpa

Geometric Coordinates of Strap Beam Footin


D1-2 0.525 m Distance from point 1-2
D2-3 2.629 m Distance from point 2-3
D3-4 0.525 m Distance from point 3-4
D4-5 0.571 m Distance from point 4-5

PLAN VIEW
3750

525

525.000

525 525.000

L = 2X = 4.25

PA - Factored = 1238 ELEVATION VIEW PB - Factored = 1703


PA - Service = 884.2857143 PB - Service = 1216
XA-B
3.15

1 2 3 4 5
Distances (m) 0.53 2.63 0.53 0.57

33.72 -33.72
STRUCTURAL ANALYSIS
DESIGN REPORT

Net Soil Pressure


Qu = (PA+PB)/(Afooting) 184.53 kPa soil pressure
Qu = (PA+PB)/(Afooting)*B 692.00 kn/m soil pressure per meter

@ Point 1 Shear = 0 0.00 kN 0


@ Point A Shear = 0.2625 181.65 kN 0
@ Point A Shear = 0.2625 -1022.63 kN 0
@ Point 2 Shear = 0.525 -840.98 kN 0
@ Point 3 Shear = 3.15 978.29 kN 0
@ Point B Shear = 3.4165 1159.94 kN 0
@ Point B Shear 3.4165 -576.78 kN 0
@ Point 4 Shear = 3.679 -395.13 kN 0
@ Point 5 Shear = 4.25 0.00 kN 0

SHEAR DIAGRAM
1159.94
978.29

181.65
0.00 0.00
-395.13
-576.78
-840.98
-1022.63

Z1 = ? Z2= ?

Location of Max moment 1.4778 From Column A

@ Point 1 Moment = 0 0.00 kN-m 0 0


@ Point A Moment = 0.2625 23.84 kN-m 0.2625 0
@ Max Moment = 1.4778 -731.78 kN-m 1.74029 0
@ Point Moment = 1.68 240.37 kN-m 3.42 0
@ Point 5 Moment = 0.8335 0.00 kN-m 4.25 0
0

3.679

MOMENT DIAGRAM
240.37

0.00 23.84 0.00

-731.78

WIDE BEAM øVc > Vu


øVc = ø(f'c)1/2Bd/6 Wide Beam Shear Formula
Effective, d1 = 395.04 mm Wide Beam Shear Effective Depth
t= 500 mm Wide Beam Shear Formula
Used t = 500 mm Wide Beam Shear Formula

Z1 = 1477.79 mm
Z2 = 1676.21 mm

Vu @ distance d from Column 2


Vu2 = 704.919565403
øVc = 1123.32716828 Safe

Used d = 412.5

øVc = 1172.97604525 Safe

PUNCHING SHEAR CHECK 1

Vu @ distance d/2 from Column 2 (Interior)


STRUCTURAL ANALYSIS
DESIGN REPORT

Vu2a = 804.513987236 (Demand Punching Shear Force Based on Shear Diaghram)


Vu2b = 1540.8125 (Demand Punching Shear Force Based on Area Method)

Used d = 412.5 mm
bo = 3750 mm
VuPunching = 1540.8125 KN
ff'c1/2bod/3 = 1759.46406787759 KN Safe

PUNCHING SHEAR CHECK 2

Vu @ distance d/2 from Column 1 (Edge)


Vu1a = 698.255754597 (Demand Punching Shear Force Based on Shear Diaghram)
Vu1b = 1111.49375 (Demand Punching Shear Force Based on Area Method)

Used d = 412.5 mm
bo = 2812.5 mm
VuPunching = 1111.49375 KN
ff'c1/2bod/3 = 1759.46406787759 KN Safe

FLEXURAL REINFORCEMENT REQUIREMENTS TOP BARS ALONG L

d= 412.5 mm
Mu = 731.78 kN-m steel ratio, r = 0.0034
Rn = 1.27425407253462 required As = 5230.98
rrqrd = 0.00320 number of bars = 10.66
rmin = 0.0034 say = 11.00 pcs - 25 mmf Both Ways
USE t = 500 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG L

d= 412.5 mm
Mu = 240.37 kN-m steel ratio, r = 0.0034
Rn = 0.41856761565827 required As = 5230.98
rrqrd = 0.00102 number of bars = 10.66
rmin = 0.0034 say = 11.00 pcs - 25 mmf Both Ways
USE t = 500 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG B

d= 412.5 mm
Mu = 1019.61 kN-m steel ratio, r = 0.0040
Rn = 1.566584634221 required As = 6958.83
rrqrd = 0.00397 number of bars = 14.18
rmin = 0.0034 say = 15.00 pcs - 25 mmf Both Ways
USE t = 500 mm
STRUCTURAL ANALYSIS
DESIGN REPORT

Footing Name CF3


Column Type Combine Footing

Design Paramters Design Paramters

Pu1 = 1638 KN Factored Axial Load Column 1


Pu2 = 1069 KN Factored Axial Load Column 2
X1 = 380 mm From Edge of Column 1 to Column 1
X2 = 4505 mm From Edge of Column 1 to Column 2
f'c = 20.7 Mpa Strength of Concrete
fy = 414 Mpa Strength of Deformed Bars
Embedment = 2500 mm Height of Soil above footing
Density, g = 18 KN/m3 Density of Soil
Concrete Density, g = 24 KN/m3 Density of Concrete
Qall (Soil Bearing Capacity)= 202.2 Kpa Allowable SBC
Trial "t" = 550 mm Assume Thickness of Footing
Increment "t" = 25 mm Rounding off Interval
Minimum "L" = 1000 mm Minimum Width of the Footing
bar Ø= 25 mm bending reinforcement
Col1 = 525 mm size of column along x dir
Col2 = 525 mm size of column along z dir

FOOTING DIMENSIONS
Qp = 144.0000 Kpa Permissible Soil Pressure
Ps1 = 1170 KN Service Axial Load Column 1

Ps2 = 763.5714285714 KN Service Axial Load Column 2

X = 2008.971185815 mm
L = 4017.942371629 mm
Use L = 6000 Total Length of Combined Footing
B = 3341.904418513
Use B = 3000 mm Width of Footing or Dimension of Footing along Z Dir

Qactual = 107.4206349206 Kpa SOIL IS ADEQUATE


Final Area = 18000000 mm2 Actual Area of Footing
Qmax = 150.3888888889 Kpa

Geometric Coordinates of Strap Beam Footin


D1-2 0.525 m Distance from point 1-2
D2-3 3.6 m Distance from point 2-3
D3-4 0.525 m Distance from point 3-4
D4-5 1.35 m Distance from point 4-5

PLAN VIEW
3000

525

525.000

525 525.000

L = 2X = 6

PA - Factored = 1638 ELEVATION VIEW PB - Factored = 1069


PA - Service = 1170 PB - Service = 764
XA-B
4.13

1 2 3 4 5
Distances (m) 0.53 3.60 0.53 1.35

727.46 -727.46
STRUCTURAL ANALYSIS
DESIGN REPORT

Net Soil Pressure


Qu = (PA+PB)/(Afooting) 150.39 kPa soil pressure
Qu = (PA+PB)/(Afooting)*B 451.17 kn/m soil pressure per meter

@ Point 1 Shear = 0 0.00 kN 0


@ Point A Shear = 0.2625 118.43 kN 0
@ Point A Shear = 0.2625 -792.11 kN 0
@ Point 2 Shear = 0.525 -673.67 kN 0
@ Point 3 Shear = 4.13 950.53 kN 0
@ Point B Shear = 4.3875 1068.96 kN 0
@ Point B Shear 4.3875 -727.51 kN 0
@ Point 4 Shear = 4.65 -609.08 kN 0
@ Point 5 Shear = 6.00 0.00 kN 0

SHEAR DIAGRAM

1068.96
950.53

118.43
0.00 0.00

-673.67 -609.08
-792.11 -727.51

Z1 = ? Z2= ?

Location of Max moment 1.7557 From Column A

@ Point 1 Moment = 0 0.00 kN-m 0 0


@ Point A Moment = 0.2625 15.54 kN-m 0.2625 0
@ Max Moment = 1.7557 -679.80 kN-m2.018182 0
@ Point Moment = 2.37 586.55 kN-m 4.39 0
@ Point 5 Moment = 1.6125 0.00 kN-m 6.00 0
0

4.65

MOMENT DIAGRAM
586.55

0.00 15.54 0.00

-679.80

WIDE BEAM øVc > Vu


øVc = ø(f'c)1/2Bd/6 Wide Beam Shear Formula
Effective, d1 = 258.8 mm Wide Beam Shear Effective Depth
t= 350 mm Wide Beam Shear Formula
Used t = 550 mm Wide Beam Shear Formula

Z1 = 1755.68 mm
Z2 = 2369.32 mm

Vu @ distance d from Column 2


Vu2 = 833.76420303
øVc = 588.734449476 Safe

Used d = 462.5

øVc = 1052.12396786 Safe

PUNCHING SHEAR CHECK 1

Vu @ distance d/2 from Column 2 (Interior)


STRUCTURAL ANALYSIS
DESIGN REPORT

Vu2a = 808.408636364 (Demand Punching Shear Force Based on Shear Diaghram)


Vu2b = 922.347335069 (Demand Punching Shear Force Based on Area Method)

Used d = 462.5 mm
bo = 3950 mm
VuPunching = 922.347335069444 KN
ff'c1/2bod/3 = 2077.94483652775 KN Safe

PUNCHING SHEAR CHECK 2

Vu @ distance d/2 from Column 1 (Edge)


Vu1a = 569.34157197 (Demand Punching Shear Force Based on Shear Diaghram)
Vu1b = 1525.69004774 (Demand Punching Shear Force Based on Area Method)

Used d = 462.5 mm
bo = 2962.5 mm
VuPunching = 1525.69004774306 KN
ff'c1/2bod/3 = 1578.18595179323 KN Safe

FLEXURAL REINFORCEMENT REQUIREMENTS TOP BARS ALONG L

d= 462.5 mm
Mu = 679.80 kN-m steel ratio, r = 0.0034
Rn = 1.17704415158961 required As = 4692.03
rrqrd = 0.00295 number of bars = 9.56
rmin = 0.0034 say = 10.00 pcs - 25 mmf Both Ways
USE t = 550 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG L

d= 462.5 mm
Mu = 586.55 kN-m steel ratio, r = 0.0034
Rn = 1.01559187565944 required As = 4692.03
rrqrd = 0.00253 number of bars = 9.56
rmin = 0.0034 say = 10.00 pcs - 25 mmf Both Ways
USE t = 550 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG B

d= 462.5 mm
Mu = 690.92 kN-m steel ratio, r = 0.0034
Rn = 0.59815010956903 required As = 9384.06
rrqrd = 0.00147 number of bars = 19.12
rmin = 0.0034 say = 20.00 pcs - 25 mmf Both Ways
USE t = 550 mm
STRUCTURAL ANALYSIS
DESIGN REPORT

Footing Name CF4


Column Type Combine Footing

Design Paramters Design Paramters

Pu1 = 1430 KN Factored Axial Load Column 1


Pu2 = 864 KN Factored Axial Load Column 2
X1 = 380 mm From Edge of Column 1 to Column 1
X2 = 4505 mm From Edge of Column 1 to Column 2
f'c = 20.7 Mpa Strength of Concrete
fy = 414 Mpa Strength of Deformed Bars
Embedment = 2500 mm Height of Soil above footing
Density, g = 18 KN/m3 Density of Soil
Concrete Density, g = 24 KN/m3 Density of Concrete
Qall (Soil Bearing Capacity)= 204 Kpa Allowable SBC
Trial "t" = 625 mm Assume Thickness of Footing
Increment "t" = 25 mm Rounding off Interval
Minimum "L" = 1000 mm Minimum Width of the Footing
bar Ø= 25 mm bending reinforcement
Col1 = 760 mm size of column along x dir
Col2 = 760 mm size of column along z dir

FOOTING DIMENSIONS
Qp = 144.0000 Kpa Permissible Soil Pressure
Ps1 = 1021.428571429 KN Service Axial Load Column 1

Ps2 = 617.1428571429 KN Service Axial Load Column 2

X = 1933.618134263 mm
L = 3867.236268527 mm
Use L = 6000 Total Length of Combined Footing
B = 2942.403169565
Use B = 1900 mm Width of Footing or Dimension of Footing along Z Dir

Qactual = 143.7343358396 Kpa SOIL IS ADEQUATE


Final Area = 11400000 mm2 Actual Area of Footing
Qmax = 201.2280701754 Kpa

Geometric Coordinates of Strap Beam Footin


D1-2 0.76 m Distance from point 1-2
D2-3 3.365 m Distance from point 2-3
D3-4 0.76 m Distance from point 3-4
D4-5 1.115 m Distance from point 4-5

PLAN VIEW
1900

760

760.000

760 760.000

L = 2X = 6

PA - Factored = 1430 ELEVATION VIEW PB - Factored = 864


PA - Service = 1021.428571 PB - Service = 617
XA-B
4.13

1 2 3 4 5
Distances (m) 0.76 3.37 0.76 1.12

593.04 -593.04
STRUCTURAL ANALYSIS
DESIGN REPORT

Net Soil Pressure


Qu = (PA+PB)/(Afooting) 201.23 kPa soil pressure
Qu = (PA+PB)/(Afooting)*B 382.33 kn/m soil pressure per meter

@ Point 1 Shear = 0 0.00 kN 0


@ Point A Shear = 0.38 145.29 kN 0
@ Point A Shear = 0.38 -691.68 kN 0
@ Point 2 Shear = 0.76 -546.39 kN 0
@ Point 3 Shear = 4.13 740.16 kN 0
@ Point B Shear = 4.505 885.45 kN 0
@ Point B Shear 4.505 -571.59 kN 0
@ Point 4 Shear = 4.885 -426.30 kN 0
@ Point 5 Shear = 6.00 0.00 kN 0

SHEAR DIAGRAM
885.45
740.16

145.29
0.00 0.00

-426.30
-546.39 -571.59
-691.68

Z1 = ? Z2= ?

Location of Max moment 1.8091 From Column A

@ Point 1 Moment = 0 0.00 kN-m 0 0


@ Point A Moment = 0.38 27.60 kN-m 0.38 0
@ Max Moment = 1.8091 -598.05 kN-m2.189091 0
@ Point Moment = 2.32 427.26 kN-m 4.51 0
@ Point 5 Moment = 1.495 0.00 kN-m 6.00 0
0

4.885

MOMENT DIAGRAM
427.26

0.00 27.60 0.00

-598.05

WIDE BEAM øVc > Vu


øVc = ø(f'c)1/2Bd/6 Wide Beam Shear Formula
Effective, d1 = 148.97 mm Wide Beam Shear Effective Depth
t= 250 mm Wide Beam Shear Formula
Used t = 625 mm Wide Beam Shear Formula

Z1 = 1809.09 mm
Z2 = 2315.91 mm

Vu @ distance d from Column 2


Vu2 = 683.206379091
øVc = 214.627981431 Safe

Used d = 537.5

øVc = 774.401154724 Safe

PUNCHING SHEAR CHECK 1

Vu @ distance d/2 from Column 2 (Interior)


STRUCTURAL ANALYSIS
DESIGN REPORT

Vu2a = 584.691240749 (Demand Punching Shear Force Based on Shear Diaghram)


Vu2b = 525.231286184 (Demand Punching Shear Force Based on Area Method)

Used d = 537.5 mm
bo = 5190 mm
VuPunching = 584.691240749201 KN
ff'c1/2bod/3 = 3173.00683659185 KN Safe

PUNCHING SHEAR CHECK 2

Vu @ distance d/2 from Column 1 (Edge)


Vu1a = 443.637007576 (Demand Punching Shear Force Based on Shear Diaghram)
Vu1b = 1161.40014309 (Demand Punching Shear Force Based on Area Method)

Used d = 537.5 mm
bo = 3892.5 mm
VuPunching = 1161.40014309211 KN
ff'c1/2bod/3 = 1161.60173208565 KN Safe

FLEXURAL REINFORCEMENT REQUIREMENTS TOP BARS ALONG L

d= 537.5 mm
Mu = 598.05 kN-m steel ratio, r = 0.0034
Rn = 1.21055011672303 required As = 3453.50
rrqrd = 0.00303 number of bars = 7.04
rmin = 0.0034 say = 8.00 pcs - 25 mmf Both Ways
USE t = 625 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG L

d= 537.5 mm
Mu = 427.26 kN-m steel ratio, r = 0.0034
Rn = 0.86485142487852 required As = 3453.50
rrqrd = 0.00214 number of bars = 7.04
rmin = 0.0034 say = 8.00 pcs - 25 mmf Both Ways
USE t = 625 mm

FLEXURAL REINFORCEMENT REQUIREMENTS BOTTOM BARS ALONG B

d= 537.5 mm
Mu = 196.14 kN-m steel ratio, r = 0.0034
Rn = 0.12572129078781 required As = 10905.80
rrqrd = 0.00030 number of bars = 22.22
rmin = 0.0034 say = 23.00 pcs - 25 mmf Both Ways
USE t = 625 mm