Professional Documents
Culture Documents
A 1622 3G and WIFI Router - Ang - Ver 1.0 - 20 752 818
A 1622 3G and WIFI Router - Ang - Ver 1.0 - 20 752 818
A 1622 3G and WIFI Router - Ang - Ver 1.0 - 20 752 818
A 1622
Instruction manual
Version 1.0, Code No. 20 752 818
Distributor:
METREL d.d.
Ljubljanskacesta 77
1354 Horjul
Slovenia
Manufacturer:
HQ JSC Teltonika
Saltoniskiust. 10c
LT-08105, Vilnius,
Lithuania
Mark on your equipment certifies that this equipment meets the requirements of the EU
(European Union) concerning safety and interference causing equipment regulations
© 2018 METREL
No part of this publication may be reproduced or utilized in any form or by any means
without permission in writing from METREL.
2
A 1622 - 3G and Wi-Fi Router Table of contents
1 Introduction............................................................................................................. 4
2 Remote Communication over 3G / GPRS network .............................................. 4
2.1 Router connection .............................................................................................4
2.2 Router Setup .....................................................................................................6
2.3 Connection status............................................................................................11
2.4 Connection check and further steps ................................................................13
3 Remote Communication over Wi-Fi network ..................................................... 13
3.1 Router connection ...........................................................................................13
3.2 Router Setup ...................................................................................................14
3.3 Connection status............................................................................................20
3.4 Connection check and further steps ................................................................20
4 Technical Specifications ...................................................................................... 21
4.1 General specification .......................................................................................21
4.2 LAN and Wi-Fi .................................................................................................21
4.3 UMTS/HSPA+ .................................................................................................22
4.4 GSM/GPRS/EDGE ..........................................................................................22
3
A 1622 - 3G and Wi-Fi Router Introduction
1 Introduction
Metrel instruments (MI 2892 Power Master, MI 2885 Master Q4, etc.) can be remotely
accessed through Ethernet communication port.
However, on measurement locations where 3G/2G mobile or Wi-Fi communication is
available, this router can be used to establish Communication Bridge to the instrument.
3G and Wi-Fi Router A 1622, is a high-speed Wi-Fi and 3G gateway, for remote access
to the measurement certified and tested by Metrel. In this manual MI 2892 Power
Master is used as example, however other Metrel instruments with Ethernet port are
used in similar way. Two configurations are supported and described:
• Instrument remote communication over 3G / GPRS network
• Instrument remote communication over Wi-Fi network
For other means of connections and configuration please check RUT 230 instruction
manual, provided by OEM manufacturer Teltonika www.teltonika.lt.
1. 2.
On following figures description of router front and back plates can be found.
5
A 1622 - 3G and Wi-Fi Router Remote Communication over 3G / GPRS network
- Through Wi-Fi, look up for Access Point RUT230_001E42***** (unique for each
device) on your computer, and connect to it (no password is required).
6
A 1622 - 3G and Wi-Fi Router Remote Communication over 3G / GPRS network
- Through LAN (Ethernet) network, plug Ethernet cable into computer and LAN
Ethernet port on Router, marked as “LAN”.
2. Launch your browser and enter the router IP into the address field:
Enter the default password admin01 into the Password field and then click on
Login button.
4. A wizard will start in order to setup router. Change default password (1) with your
own, Time Zone Settings (2) and Synchronize time (3) with the browser
7
A 1622 - 3G and Wi-Fi Router Remote Communication over 3G / GPRS network
1.
3.
2.
7. Set up wireless network if you would like to use router as access point. Don’t
forget to protect it with password and encryption.
8. Press Save button. Router will now apply new settings and restart.
9. Select Mobile interface as gateway to the system.
9
A 1622 - 3G and Wi-Fi Router Remote Communication over 3G / GPRS network
10
A 1622 - 3G and Wi-Fi Router Remote Communication over 3G / GPRS network
11. Connect instrument and modem with Ethernet cable. Use Ethernet port marked
as “LAN” on the Router.
11
A 1622 - 3G and Wi-Fi Router Remote Communication over 3G / GPRS network
12
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
13
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
2.
1.
14
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
- through LAN (Ethernet) network, plug Ethernet cable into computer and LAN
Ethernet port marked as “LAN” on the router
2. Launch your browser and enter the routers IP into the address field:
Enter the default password admin01 into the Password field and then click on
Login button.
4. A wizard will start in order to setup router. Change default password (1) with your
own, Time Zone Settings (2) and Synchronize time (3) with the browser
1.
3.
2.
15
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
16
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
12. Press Save button. Router will now apply new settings and restart.
13. In Network WAN menu select Wifi option (gateway to the system). Press Save
Button, and wait that router reconfigure operation mode.
17
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
16. If necessary, provide network password in provided text field. Press Save button
afterwards.
18
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
17. Before new settings are applied, please double check that all settings are correct
– WiFi interface used as gateway to the system.
18. Connect instrument and modem with Ethernet cable. Use Ethernet port marked
as “LAN” on the Router.
19
A 1622 - 3G and Wi-Fi Router Remote Communication over Wi-Fi network
4 Technical Specifications
In this section basic router specification is given. For complete technical specification
please check RUT 230 user manual, provided by Teltonika.
21
A 1622 - 3G and Wi-Fi Router Technical Specifications
4.3 UMTS/HSPA+
- 900/2100 MHz
- HSDPA mode: 14.5 Mbps (Cat 10) downlink speed
- HSUPA mode: 5.76 Mbps (Cat 6) uplink speed
- UMTS mode: 384 kbps DL, 384 kbps UL
- Power Class 3 (24dBm +1/-3dB) for UMTS bands
4.4 GSM/GPRS/EDGE
- 850/900/1800/1900 Mhz
- GPRS/EDGE Multi-slot Class 12
- Power Class E2 (27dBm ±3dB) for EDGE 850/900
- Power Class E2 (26dBm ±3/-4dB) for EDGE 1800/1900
- Power Class 4 (33dBm ±2dB) for GSM 850/900
- Power Class 1 (30dBm ±2dB) for GSM 1800/1900