Download as pdf or txt
Download as pdf or txt
You are on page 1of 51

Slot Format Configuration

Product Version: NR22.2

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P. R. China
Postcode:518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION

Copyright ©2020 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties.
Any reproduction or distribution of this document or any portion of this document, in any
form by any means, without the prior written consent of ZTE CORPORATION is prohibited.
Additionally, the contents of this document are protected by contractual confidentiality
obligations.

All company, brand and product names are trade or service marks, or registered trade or
service marks, of ZTE CORPORATION or of their respective owners.

This document is provided“as is”, and all express, implied, or statutory warranties,
representations or conditions are disclaimed, including without limitation any implied
warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE
CORPORATION and its licensors shall not be liable for damages resulting from the use of or
reliance on the information contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights
or applications covering the subject matter of this document. Except as expressly provided
in any written license between ZTE CORPORATION and its licensee, the user of this
document shall not acquire any license to the subject matter herein.

ZTE CORPORATION reserves the right to upgrade or make technical change to this product
without further notice.

Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire


related information.

The ultimate right to interpret this product resides in ZTE CORPORATION.

Serial Number:2023-03-05
Slot Format Configuration

Slot Format Configuration

1 About This Document

1.1 Personal Data Security Statement

Some of the features listed in this document need users’ personal data during provisioning, including the SUPI, IMSI, IMEI, MSISDN, and UEIP.
These features are used for the purpose of implementing the service procedures or location procedures specified by 3GPP, optimizing service
experience of users, and facilitating system maintenance. When activating these features, you shall comply with local laws and regulations on
personal data protection and privacy protection.For any inquiries on the legality of activating these features, please consult your legal
department.

1.2 Changes

This section describes the changes between different versions of the product, including two types of changes:
Technical changes: technical changes and parameter changes between different versions.
Description changes: description and structure changes between different versions, including content optimization and supplementation.

Change Type Change Date Description Parameter Change

Technical changes 2023-01-30 Compared with the previous NR22.1 version, there is no change. None

Description changes 2023-01-30 Compared with the previous NR22.1 version, there is no change. None

2 Document Description

2.1 Covered Features

The following table lists the features covered in this document.

Table 1 Covered Feature List

No. Feature ID Feature Name Scenario Refer to

1 ZNR03-08-090 Slot Format Configuration SA&NSA 4 Slot Format Configuration

2.2 Correlation with Other Features

Table 2 Correlation with Other Features

Feature ID Feature Name Required Feature Mutually Exclusive Feature Impacted Feature

ZNR03-08-090 Slot Format Configuration None None None

2.3 Terms and Definitions

For the related terms and definitions, refer to the following table.

Table 3 Terms and Definitions

Term Full Name Definition

CP Cyclic Prefix The prefixing of a symbol with a repetition of the end.

GP Guard Period Several symbols for switching from Downlink to Uplink in TDD system.

2.4 Feature Difference Descriptions

3 - 51
Slot Format Configuration

2.4.1 Difference Between FR1 FDD and FR1 TDD

Table 4 Difference Between FR1 FDD and FR1 TDD

Feature Difference Description Refer To

Slot Format FR1 TDD supports the following frame structures: 2.5 ms dual-period, 5 ms single-period, 2.5 ms single- 3 Overview
Configuration period, 3+2 dual-period (type 1), 3+2 dual-period (type 2), DSUUU single-period,and 1 ms single-period. 4 Slot Format
FR1 TDD supports the following frame structures: By modifying the subcarrier spacing configuration, each Configuration
slot has uplink and downlink, and there is no difference between D, S and U timeslots.

2.4.2 Difference Between NSA and SA Networks

Table 5 Difference Between NSA and SA Networks

Feature Difference Description Refer To

Slot Format Configuration Support NSA and SA with no difference. All

2.4.3 Difference Between FR1 and FR2

Here in this document, FR1 refers to 410MHz~7125MHz, FR2 refers to 24250MHz~52600MHz. For detailed definition of FR1 and FR2, refer to 5.1
General in 3GPP TS 38.104 V15.5.0.

Table 6 Difference Between FR1 and FR2

Feature Difference Description Refer To

Slot Format FR1 Supports 2.5 ms dual-period, 5 ms single-period, 2.5 ms single-period, 3+2 dual-period (type 1), 3 Overview
Configuration 3+2 dual-period (type 2) and DSUUU single-period. 4 Slot Format Con
FR2 supports only DDDSU and DSUUU timeslots. figuration

3 Overview
This document describes the 5G NR radio frame structure, and describes the PHY parameter configurations related to the TDD system and FDD
system. For the TDD system, with the specific subcarrier spacing, operators can modify the slot types of radio frames and the proportions of UL,
DL, and GP symbols in flexible slots to adapt to business development requirements. For the FDD system, operators can modify the subcarrier
spacing configuration to meet the requirements in different business scenarios.
As specified in the 3GPP TS 38.211:

1 Each radio frame is 10 ms long, consisting of 10 subframes, and each subframe is 1 ms long. Each subframe of the FR1 contains 2
timeslots, see Figure 1, and each subframe of the FR2 contains 8 timeslots, see Figure 3.

2 Compared with LTE, NR supports more flexible subcarrier spacing configurations, which are determined by the transmission
parameter set μ. The number of slots in each subframe varies with subcarrier spacing. For details, refer to Table 7.

3 For radio frames of the TDD system, the slot types and the number of UL symbols and the number of DL symbols in each slot can be
configured as required. The used 5G NR slot formats fall into three types: UL slots, DL slots, and flexible slots.

■ An uplink slot contains uplink symbols only.

■ A downlink slot contains downlink symbols only.

■ A flexible slot contains uplink symbols, downlink symbols, and Guard Period (GP) symbols.

Table 7 Transmission Parameter Set Supported by 5G NR

μ Subcarrier Spacing(kHz) Number of Slots per Subframe Number of Symbols per Slot

0 15 1 14

4 - 51
Slot Format Configuration

1 30 2 14

2 60 4 14 (Normal CP), 12 (Extended CP)

3 120 8 14

4 240 16 14

The frequency bands above 6 GHz use the configurations of μ = 3 and μ = 4. The frequency bands below 6 GHz use the configurations of μ = 0, μ
= 1, and μ = 2.
This document mainly introduces the TDD system of the frequency band below 6 GHz (FR1 TDD), the TDD system of the frequency band above
6 GHz (FR2 TDD) and the FDD system of the frequency band below 1 GHz (FR1 FDD). For the FR1 TDD system, μ is fixed to 1 by default. For the
FR2 TDD system, μ is fixed to 3. For the FDD system, μ is fixed to 0 by default.

Figure 1 Schematic Diagram of the NR FR1 TDD Frame Structure

Figure 2 Schematic Diagram of the NR FR1 FDD Frame Structure

Figure 3 Schematic Diagram of the NR FR2 Frame Structure

4 Slot Format Configuration

4.1 Principle

By modifying the slot format parameters, the 5G NR system supports 2.5 ms doubly periodic radio frame , 5 ms periodic radio frame, 2.5 ms
periodic radio frame with configuration as DDDSU, 3+2 ms doubly periodic radio frame, 2.5 ms periodic radio frame with configuration as
DSUUU and 1ms periodic radio frame with configuration as DS.

5 - 51
Slot Format Configuration

■ The 2.5 ms doubly periodic radio frame provides a larger ratio of uplink slots.

■ The 5 ms periodic radio frame provides a larger ratio of downlink slots.

■ The 3+2 ms dual period is divided into two types. The main difference is that the number of D timeslots is different from the number of U

timeslots. The 3+2 ms dual period (the type 1) ratio is DDDSUUDDDD, which is consistent with the ratio of 5 ms single period to
uplink/downlink timeslots) is 3+2 ms dual period (the type 2) ratio is DDDSUUDSUU).
■ The 2.5 ms periodical radio frame with configuration as DDDSU reduces the downlink slot ratio and increases the flexible slot ratio

based on the 5 ms periodical radio frame type.


■ The 2.5 ms periodic radio frame with configuration as DSUUU has more uplink slots which ocuppy 60%.

■ The radio frame structure of 1ms DS in a single period has a larger proportion of uplink timeslots.

In the 5G NR system, you can change the ratio of uplink symbols to downlink symbols and the number of GP symbols in the flexible slot of the
radio frame structure by modifying the following parameters: the number of uplink symbols, the number of downlink symbols, and the number
of GP symbols of the flexible slot.

■ Adjusting the ratio of uplink symbols to downlink symbols in the flexible slot make it possible to adapt to uplink and downlink service

requirements of operators.
■ Different number of GP symbols adapts to different cell radius.

The following sections describe five typical slot configurations.

4.1.1 FR1 TDD Slot Configuration

4.1.1.1 Doubly Periodical Slot Structure (2.5 ms)

FR1 TDD gNodeBs support the 2.5 ms doubly periodic frame structure, see Figure 4.

■ One radio frame consists of 20 slots.

■ Taking 5 ms (10 timeslots) as a period, the uplink slot allocation and downlink slot allocation in the first 2.5 ms and the second 2.5 ms of

the 5 ms are different.

Figure 5 shows the symbol structure of the flexible slot. In the default configuration, one flexible slot consists of 10 downlink symbols, 2 GP
symbols, and 2 uplink symbols.

Figure 4 2.5 ms Doubly Periodic Slot Configuration

notes: D denotes the downlink slot,U denotes the uplink slot,S denotes the flexible slot.

Figure 5 2.5 ms Doubly Periodic Flexible Slot Symbol Configuration

notes: D denotes the downlink symbol,U denotes the uplink symbol,GP denotes the guard symbol.
For a description of the relevant parameters, refer to Table 8.

Table 8 2.5 ms Doubly Periodic Slot Format Parameters

Parameter Name Description

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are
respectively set to 1 (DL slot), 1 (DL slot), 1 (DL slot), 2 (Flexible slot), and 0 (UL slot).

dlULTransmissionPeriodicity1 The time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms5.

6 - 51
Slot Format Configuration

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymb
ols1) is set to 10.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1)
is set to 2.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 2.

frameType2Present For the second period, TddConfig.frameType2Present is set to 1.

frameType2 The slot types corresponding to the frame type in the second period (TddConfig.frameType2) are
respectively set to 1 (DL slot), 1 (DL slot), 2 (Flexible slot), 0 (UL slot), and 0 (UL slot).

dlULTransmissionPeriodicity2 The time length of the second period (TddConfig.dlULTransmissionPeriodicity2) is set to ms2p5.

nrofDownlinkSymbols2 The number of downlink symbols of the flexible slot in the second period (TddConfig.nrofDownlinkSy
mbols2) is set to 10.

nrofUplinkSymbols2 The number of uplink symbols of the flexible slot in the second period (TddConfig.nrofUplinkSymbols
2) is set to 2.

4.1.1.2 Periodic Slot Structure (5 ms)

FR1 TDD gNodeBs support the 5 ms periodic frame structure, see Figure 6.

■ One radio frame consists of 20 slots.

■ 5 ms (10 slots) are taken as a period.

Figure 7 shows the symbol structure of the flexible slot. In the default configuration, one flexible slot consists of 6 downlink symbols, 4 GP
symbols, and 4 uplink symbols.

Figure 6 5 ms Periodic Slot Configuration

notes: D denotes the downlink slot,U denotes the uplink slot,S denotes the flexible slot.

Figure 7 5 ms Periodic Flexible Slot Symbol Configuration

notes: D denotes the downlink symbol,U denotes the uplink symbol,GP denotes the guard symbol.
For the related parameters, refer to the following table.

Table 9 5 ms Periodic Slot Format Parameters

Parameter Name Description

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are
respectively set to 1 (DL slot), 1 (DL slot), 1 (DL slot), 1 (DL slot), 1 (DL slot), 1 (DL slot), 1 (DL slot), 2
(Flexible slot), 0 (UL slot), and 0 (UL slot).

dlULTransmissionPeriodicity1 The time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms5.

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols
1) is set to 6.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is
set to 4.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 4.

frameType2Present For the second period, TddConfig.frameType2Present is set to 0.

7 - 51
Slot Format Configuration

4.1.1.3 Doubly Periodical Slot Structure(3+2 ms)(type 1)

FR1 TDD gNodeBs support the 3+2 ms doubly periodic frame structure(type 1), see Figure 8.

■ One radio frame consists of 20 slots.

■ Taking 5 ms (10 timeslots) as a period, the uplink slot allocation and downlink slot allocation in the first 3 ms and the second 2 ms of the

5 ms are different.
■ The specific time slot ratio is DDDSUUDDDD.

Figure 9 shows the symbol structure of the flexible slot. In the default configuration, one flexible slot consists of 6 downlink symbols, 4 GP
symbols, and 4 uplink symbols.
Note: Currently, only 64T and 32T are supported.

Figure 8 3+2 ms Doubly Periodic Slot(type 1) Configuration

notes: D denotes the downlink slot,U denotes the uplink slot,S denotes the flexible slot.

Figure 9 3+2 ms Doubly Periodic(type 1) Flexible Slot Symbol Configuration

notes: D denotes the downlink symbol,U denotes the uplink symbol,GP denotes the guard symbol.
For a description of the relevant parameters, refer to Table 10.

Table 10 3+2 ms Doubly Periodic Slot(type 1) Format Parameters

Parameter Name Description

dlULTransmissionPeriodicity1 The time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms3.

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are respectively
set to 1 (DL slot), 1 (DL slot), 1 (DL slot), 2 (Flexible slot), 0 (UL slot), and 0 (UL slot).

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols1) is
set to 6.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is set to
4.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 4.

frameType2Present For the second period, TddConfig.frameType2Present is set to 1.

frameType2 The slot types corresponding to the frame type in the second period (TddConfig.frameType2) are
respectively set to 1 (DL slot), 1 (DL slot), 1 (DL slot), and 1 (DL slot).

dlULTransmissionPeriodicity2 The time length of the second period (TddConfig.dlULTransmissionPeriodicity2) is set to ms2.

nrofDownlinkSymbols2 The number of downlink symbols of the flexible slot in the second period
(TddConfig.nrofDownlinkSymbols2) is set to 0.

nrofUplinkSymbols2 The number of uplink symbols of the flexible slot in the second period (TddConfig.nrofUplinkSymbols2) is set
to 0.

4.1.1.4 Doubly Periodical Slot Structure(3+2 ms)(type 2)

FR1 TDD gNodeBs support the 3+2 ms doubly periodic frame structure(type 2), see Figure 10.

■ One radio frame consists of 20 slots.

8 - 51
Slot Format Configuration

■ Taking 5 ms (10 timeslots) as a period, the uplink slot allocation and downlink slot allocation in the first 3 ms and the second 2 ms of the

5 ms are different.
■ The specific time slot ratio is DDDSUUDSUU.

Figure 11 shows the symbol structure of the flexible slot. In the default configuration, one flexible slot consists of 6 downlink symbols, 4 GP
symbols, and 4 uplink symbols.
Note: Currently, only 64T and 32T are supported.

Figure 10 3+2 ms Doubly Periodic Slot(type 2) Configuration

notes: D denotes the downlink slot,U denotes the uplink slot,S denotes the flexible slot.

Figure 11 3+2 ms Doubly Periodic(type 2) Flexible Slot Symbol Configuration

notes: D denotes the downlink symbol,U denotes the uplink symbol,GP denotes the guard symbol.
For a description of the relevant parameters, refer to Table 11.

Table 11 3+2 ms Doubly Periodic Slot(type 2) Format Parameters

Parameter Name Description

dlULTransmissionPeriodicity1 The time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms3.

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are respectively
set to 1 (DL slot), 1 (DL slot), 1 (DL slot), 2 (Flexible slot), 0 (UL slot), and 0 (UL slot).

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols1) is
set to 6.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is set to
4.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 4.

frameType2Present For the second period, TddConfig.frameType2Present is set to 1.

frameType2 The slot types corresponding to the frame type in the second period (TddConfig.frameType2) are
respectively set to 1 (DL slot), 2 (Flexible slot), 0 (UL slot), and 0 (UL slot).

dlULTransmissionPeriodicity2 The time length of the second period (TddConfig.dlULTransmissionPeriodicity2) is set to ms2.

nrofDownlinkSymbols2 The number of downlink symbols of the flexible slot in the second period
(TddConfig.nrofDownlinkSymbols2) is set to 6.

nrofUplinkSymbols2 The number of uplink symbols of the flexible slot in the second period (TddConfig.nrofUplinkSymbols2) is set
to 4.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 4.

4.1.1.5 Periodic Slot Structure (2.5 ms DSUUU)

The TDD gNodeBs support the DSUUU single-period frame structure. FR1 TDD gNodeBs support the 2.5 ms periodic frame structure with
DSUUU, see Figure 12.

Figure 12 FR1 TDD 2.5 ms Periodic Slot Configuration in DSUUU

9 - 51
Slot Format Configuration

notes: D denotes the downlink symbol,U denotes the uplink symbol,S denotes the flexible slot.
Figure 5 shows the symbol structure of the flexible slot. In the default configuration, both of FR1 TDD and FR2 TDD, one flexible slot consists of
10 downlink symbols, 2 GP symbols, and 2 uplink symbols.
For the related parameters, refer to the following table.

Table 12 2.5 ms Periodic Slot Format in DSUUU Parameters

Parameter Name Description

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are respectively
set to 1 (DL slot), 2 (Flexible slot), 0 (UL slot), 0 (UL slot), 0 (UL slot), and 0 (UL slot).

dlULTransmissionPeriodicity1 The time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms2p5.

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols1) is
set to 10.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is set to
2.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 2.

frameType2Present For the second period, TddConfig.frameType2Present is set to 0.

4.1.1.6 Periodic Slot Structure

FR1 TDD gNodeBs support the 2.5 ms periodic frame structure, see Figure 13.

■ One radio frame of FR1 TDD consists of 20 slots.

■ FR1 TDD takes 2.5 ms (5 timeslots) as a period.

Figure 5 shows the symbol structure of the flexible slot. In the default configuration, both of FR1 TDD and FR2 TDD, one flexible slot consists of
10 downlink symbols, 2 GP symbols, and 2 uplink symbols.

Figure 13 FR1 TDD DDDSU 2.5 ms Periodic Slot Configuration

notes: D denotes the downlink symbol,U denotes the uplink symbol,S denotes the flexible slot.
For the related parameters, refer to the following table.

Table 13 Slot Format Parameters

Parameter Name Description

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are respectively
set to 1 (DL slot), 1 (DL slot), 1 (DL slot), 2 (Flexible slot), and 0 (UL slot).

dlULTransmissionPeriodicity1 For FR1 TDD, the time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms2p5.

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols1) is
set to 10.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is set to
2.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 2.

10 - 51
Slot Format Configuration

frameType2Present For the second period, TddConfig.frameType2Present is set to 0.

4.1.1.7 Periodic Slot Structure (1 ms DS)

The TDD gNodeBs support the DS single-period frame structure. FR1 TDD gNodeBs support the 1 ms periodic frame structure with DS, see
Figure 14.

■ One radio frame of FR1 TDD consists of 20 slots.

■ FR1 TDD takes 1 ms (2 timeslots) as a period.

Figure 14 FR1 TDD 1 ms Periodic Slot Configuration in DS

notes: D denotes the downlink symbol,U denotes the uplink symbol,S denotes the flexible slot.

Figure 15 1 ms Periodic Flexible Slot Symbol Configuration

Figure 15 shows the symbol structure of the flexible slot. In the default configuration, one flexible slot consists of 0 downlink symbols, 12 GP
symbols, and 12 uplink symbols.
For the related parameters, refer to the following table.

Table 14 1 ms Periodic Slot Format in DS Parameters

Parameter Name Description

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are respectively
set to 1 (DL slot), 2 (Flexible slot).

dlULTransmissionPeriodicity1 The time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms1.

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols1) is
set to 0.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is set to
12.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 2.

frameType2Present For the second period, TddConfig.frameType2Present is set to 0.

4.1.2 FR2 Slot Format Configuration

4.1.2.1 Periodic Slot Structure (0.625 ms DSUUU)

The TDD gNodeBs support the DSUUU single-period frame structure. FR2 TDD gNodeBs support the 0.625 ms periodic frame structure with
DSUUU, see Figure 16.

Figure 16 FR2 TDD 0.625 ms Periodic Slot Configuration in DSUUU

notes: D denotes the downlink symbol,U denotes the uplink symbol,S denotes the flexible slot.

11 - 51
Slot Format Configuration

Figure 5 shows the symbol structure of the flexible slot. In the default configuration, both of FR1 TDD and FR2 TDD, one flexible slot consists of
10 downlink symbols, 2 GP symbols, and 2 uplink symbols.
For the related parameters, refer to the following table.

Table 15 2.5 ms Periodic Slot Format in DSUUU Parameters

Parameter Name Description

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are respectively
set to 1 (DL slot), 2 (Flexible slot), 0 (UL slot), 0 (UL slot), 0 (UL slot), and 0 (UL slot).

dlULTransmissionPeriodicity1 The time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms2p5.

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols1) is
set to 10.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is set to
2.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 2.

frameType2Present For the second period, TddConfig.frameType2Present is set to 0.

4.1.2.2 Periodic Slot Structure (0.625 ms DDDSU)

FR2 TDD gNodeBs support the 0.625 ms periodic frame structure, see Figure 17.

■ One radio frame of FR2 TDD consists of 80 slots.

■ FR2 TDD takes 0.625 ms (5 timeslots) as a period.

Figure 5 shows the symbol structure of the flexible slot. In the default configuration, both of FR1 TDD and FR2 TDD, one flexible slot consists of
10 downlink symbols, 2 GP symbols, and 2 uplink symbols.

Figure 17 FR2 TDD DDDSU 0.625 ms Periodic Slot Configuration

notes: D denotes the downlink symbol,U denotes the uplink symbol,S denotes the flexible slot.
For the related parameters, refer to the following table.

Table 16 Slot Format Parameters

Parameter Name Description

frameType1 The slot types corresponding to the frame type in the first period (TddConfig.frameType1) are respectively
set to 1 (DL slot), 1 (DL slot), 1 (DL slot), 2 (Flexible slot), and 0 (UL slot).

dlULTransmissionPeriodicity1 For FR2 TDD, the time length of the first period (TddConfig.dlULTransmissionPeriodicity1) is set to ms0p625.

nrofDownlinkSymbols1 The number of downlink symbols of the flexible slot in the first period (TddConfig.nrofDownlinkSymbols1) is
set to 10.

nrofUplinkSymbols1 The number of uplink symbols of the flexible slot in the first period (TddConfig.nrofUplinkSymbols1) is set to
2.

gpNum The number of GP symbols of the flexible slot (TddConfig.gpNum) is set to 2.

frameType2Present For the second period, TddConfig.frameType2Present is set to 0.

4.1.3 Network Analysis

12 - 51
Slot Format Configuration

The feature activation effect depends on the network environment. Therefore, this document only guides the feature provisioning. For network
gains pertinent contents, refer to ZTE for support.

4.1.4 Benefit Analysis

None.

4.1.5 Impact Analysis

■ To meet the requirements of different carriers, different frame structures are required.

■ After GP symbols are added, the number of PDSCH symbols or the number of PUSCH symbols in the flexible slot may decrease, causing

the cell DL peak traffic or cell UL peak traffic to decrease.


■ The cell will automatically reset and the corresponding services will be interrupted after the following parameters are modified: the

radio frame type, or the number of UL symbols, the number of DL symbols, or the number of GP symbols of the flexible slot.

4.2 Application Scenarios

NSA scenarios and SA scenarios are not distinguished.

4.3 Provisioning Guidance

4.3.1 Prerequisites

Table 17 Hardware Requirement

Device Description Remark

5GC/EPC No special requirements None

BBU No special requirements None

AAU/RRU/Qcell No special requirements None

UE No special requirements None

Table 18 Other Requirement

Other Requirement Description

CN None

Carrier frequency bands, frequencies, and bandwidths None

UE None

Transmission bandwidth None

FTP server None

4.3.2 Restrictions

None.

4.3.3 Feature Activation

4.3.3.1 FR1 TDD Feature Activation Process

Table 19 Soft Format Configuration Related Parameters

No. Step Related Parameter Verification

13 - 51
Slot Format Configuration

1 Add PLMN in DU PlmnIdList.pLMNId None

2 Invoke added PLMN and two original ones in DU PlmnGroupList.refPlmnIdList None

3 Add a record in network slice configuration in DU NetworkSliceSubnet.nssiId None


NetworkSliceSubnet.operationalState

The frame structure configuration can be set to :


(1) the 2.5 ms doubly periodic radio frame ,
(2) the 5 ms periodic radio frame
(3) the 2.5 ms periodic radio frame DDDSU.
(4) the 3+2 ms doubly periodic radio frame
(5) the 2.5 ms periodic radio frame DSUUU
(5) the 1 ms periodic radio frame DS
In accordance with the business requirements and coverage requirements for different application scenarios, the slot format parameters can
be modified in accordance with the following table.
Path:
Planned Area > Smart Configuration > MO Editor > Selected NE > ManagedElement > NRRadioInfrastructure > NRPhysicalCellDU > TddConfig

Table 20 2.5 ms Doubly Periodic Frame Structure Feature Activation

No. Parameter Parameter Name Configuration Parameter Path Configuration


ID Example Principle

1 TddConfig Duration of the first ms2p5[ms2p5] Managed This


.dlULTrans period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
missionPe structure structure configuration should be
riodicity1
configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

2 TddConfig Frame type of the first 1;1;1;2;0 Managed Set this


.frameTyp period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
e1 structure structure configuration accordance
with the frame
structure
actually used
by the
operator. After
this parameter
is configured,
it is
recommended
not to modify
the
configuration.

14 - 51
Slot Format Configuration

3 TddConfig Number of DL 10 Managed This


.nrofDown symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
linkSymbo slot in the first period structure configuration configured
ls1
of the frame structure and
determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

4 TddConfig Number of UL 2 Managed This


.nrofUplin symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
kSymbols slot in the first period structure configuration configured
1
of the frame structure and
determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

5 TddConfig Number of GP 2 Managed This


.gpNum symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
slot of the frame structure configuration should be
structure configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

15 - 51
Slot Format Configuration

6 TddConfig Whether to configure 1 Managed This


.frameTyp the second-period Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
e2Present frame type of the structure configuration should be
frame structure configured in
accordance
with the actual
frame
structure used
by the
operator. If the
operator uses
the dual
periodicity
frame
structure, set
this parameter
to 1.

7 TddConfig Duration of the ms2p5[ms2p5] Managed This


.dlULTrans second period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
missionPe frame structure structure configuration should be
riodicity2
configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

8 TddConfig Frame type of the 1;1;2;0;0 Managed Set this


.frameTyp second period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
e2 frame structure structure configuration accordance
with the frame
structure
actually used
by the
operator. After
this parameter
is configured,
it is
recommended
not to modify
the
configuration.

16 - 51
Slot Format Configuration

9 TddConfig Number of UL 2 Managed This


.nrofUplin symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
kSymbols slot in the second structure configuration should be
2
period of the frame configured in
structure accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

10 TddConfig Number of DL 10 Managed This


.nrofDown symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
linkSymbo slot in the second structure configuration should be
ls2
period of the frame configured in
structure accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

Figure 18 Parameters for 2.5 ms Doubly Periodic Frame Structure Feature Activation

17 - 51
Slot Format Configuration

Path: Planned Area > Smart Configuration > MO Editor > Selected NE > ManagedElement > NRRadioInfrastructure > NRPhysicalCellDU >
TddConfig

Table 21 5 ms Periodic Frame Structure Feature Activation

No. Parameter Parameter Name Configuration Ex Parameter Path Configuration


ID ample Principle

1 TddConfig Duration of the first ms5[ms5] Managed This


.dlULTran period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
smissionP structure structure configuration should be
eriodicity1
configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

2 TddConfig Frame type of the 1;1;1;1;1;1;1;2;0;0 Managed Set this


.frameTyp first period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
e1 frame structure structure configuration accordance
with the frame
structure
actually used
by the
operator. After
this parameter
is configured,
it is
recommended
not to modify
the
configuration.

3 TddConfig Number of DL 6 Managed This


.nrofDown symbols on a Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
linkSymbo special slot in the structure configuration configured
ls1
first period of the and
frame structure determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

18 - 51
Slot Format Configuration

4 TddConfig Number of UL 4 Managed This


.nrofUplin symbols on a Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
kSymbols special slot in the structure configuration configured
1
first period of the and
frame structure determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

5 TddConfig Number of GP 4 Managed This


.gpNum symbols on a Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
special slot of the structure configuration should be
frame structure configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

6 TddConfig Whether to 0 Managed This


.frameTyp configure the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
e2Present second-period structure configuration should be
frame type of the configured in
frame structure accordance
with the actual
frame
structure used
by the
operator. If the
operator uses
the dual
periodicity
frame
structure, set
this parameter
to 1.

Figure 19 Parameters for 5 ms Periodic Frame Structure Feature Activation

19 - 51
Slot Format Configuration

Path: Planned Area > Smart Configuration > MO Editor > Selected NE > ManagedElement > NRRadioInfrastructure > NRPhysicalCellDU >
TddConfig

Table 22 2.5 ms Periodic Frame DDDSU Structure Feature Activation

No. Parameter Parameter Name Configuration Parameter Path Configuration


ID Example Principle

1 TddConfig Duration of the first ms2p5[ms2p5] Managed This


.dlULTrans period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
missionPe structure structure configuration should be
riodicity1
configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

20 - 51
Slot Format Configuration

2 TddConfig Frame type of the first 1;1;1;2;0 Managed Set this


.frameTyp period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
e1 structure structure configuration accordance
with the frame
structure
actually used
by the
operator. After
this parameter
is configured,
it is
recommended
not to modify
the
configuration.

3 TddConfig Number of DL 10 Managed This


.nrofDown symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
linkSymbo slot in the first period structure configuration configured
ls1
of the frame structure and
determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

4 TddConfig Number of UL 2 Managed This


.nrofUplin symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
kSymbols slot in the first period structure configuration configured
1
of the frame structure and
determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

21 - 51
Slot Format Configuration

5 TddConfig Number of GP 2 Managed This


.gpNum symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
slot of the frame structure configuration should be
structure configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

6 TddConfig Whether to configure 0 Managed This


.frameTyp the second-period Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
e2Present frame type of the structure configuration should be
frame structure configured in
accordance
with the actual
frame
structure used
by the
operator. If the
operator uses
the dual
periodicity
frame
structure, set
this parameter
to 1.

Figure 20 Parameters for 2.5 ms Periodic Frame DDDSU Structure Feature Activation

22 - 51
Slot Format Configuration

Path: Planned Area > Smart Configuration > MO Editor > Selected NE > ManagedElement > NRRadioInfrastructure > NRPhysicalCellDU >
TddConfig

Table 23 3+2 ms Doubly Periodic Frame Structure (type 1) Feature Activation

No. Parameter Parameter Name Configurat Parameter Path Configuration Pri


ID ion Examp nciple
le

1 TddConfig. Duration of the first ms3[ms3] Managed This parameter


dlULTrans period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
missionPe structure structure configuration configured in
riodicity1
accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

2 TddConfig. Frame type of the first 1;1;1;2;0;0 Managed Set this


frameType period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
1 structure structure configuration accordance with
the frame
structure actually
used by the
operator. After
this parameter is
configured, it is
recommended
not to modify the
configuration.

23 - 51
Slot Format Configuration

3 TddConfig. Number of DL symbols 6 Managed This parameter is


nrofDownl on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame configured and
inkSymbol first period of the structure configuration determined in
s1
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

4 TddConfig. Number of UL symbols 4 Managed This parameter is


nrofUplink on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame configured and
Symbols1 first period of the structure configuration determined in
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

5 TddConfig. Number of GP symbols 4 Managed This parameter


gpNum on a special slot of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
frame structure structure configuration configured in
accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

6 TddConfig. Whether to configure 1 Managed This parameter


frameType the second-period Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
2Present frame type of the structure configuration configured in
frame structure accordance with
the actual frame
structure used by
the operator. If
the operator uses
the dual
periodicity frame
structure, set this
parameter to 1.

24 - 51
Slot Format Configuration

7 TddConfig. Duration of the second ms2[ms2] Managed This parameter


dlULTrans period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
missionPe structure structure configuration configured in
riodicity2
accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

8 TddConfig. Frame type of the 1;1;1;1;null Managed Set this


frameType second period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
2 frame structure structure configuration accordance with
the frame
structure actually
used by the
operator. After
this parameter is
configured, it is
recommended
not to modify the
configuration.

9 TddConfig. Number of UL symbols 0 Managed This parameter


nrofUplink on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
Symbols2 second period of the structure configuration configured in
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

10 TddConfig. Number of DL symbols 0 Managed This parameter


nrofDownl on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
inkSymbol second period of the structure configuration configured in
s2
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

Figure 21 3+2ms Doubly Periodic Frame Structure (type 1) Feature Activation

25 - 51
Slot Format Configuration

Path: Planned Area > Smart Configuration > MO Editor > Selected NE > ManagedElement > NRRadioInfrastructure > NRPhysicalCellDU >
TddConfig

Table 24 3+2 ms Doubly Periodic Frame Structure (type 2) Feature Activation

No. Parameter Parameter Name Configurat Parameter Path Configuration Pri


ID ion Examp nciple
le

1 TddConfig. Duration of the first ms3[ms3] Managed This parameter


dlULTrans period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
missionPe structure structure configuration configured in
riodicity1
accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

2 TddConfig. Frame type of the first 1;1;1;2;0;0 Managed Set this


frameType period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
1 structure structure configuration accordance with
the frame
structure actually
used by the
operator. After
this parameter is
configured, it is
recommended
not to modify the
configuration.

26 - 51
Slot Format Configuration

3 TddConfig. Number of DL symbols 6 Managed This parameter is


nrofDownl on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame configured and
inkSymbol first period of the structure configuration determined in
s1
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

4 TddConfig. Number of UL symbols 4 Managed This parameter is


nrofUplink on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame configured and
Symbols1 first period of the structure configuration determined in
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

5 TddConfig. Number of GP symbols 4 Managed This parameter


gpNum on a special slot of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
frame structure structure configuration configured in
accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

6 TddConfig. Whether to configure 1 Managed This parameter


frameType the second-period Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
2Present frame type of the structure configuration configured in
frame structure accordance with
the actual frame
structure used by
the operator. If
the operator uses
the dual
periodicity frame
structure, set this
parameter to 1.

27 - 51
Slot Format Configuration

7 TddConfig. Duration of the second ms2[ms2] Managed This parameter


dlULTrans period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
missionPe structure structure configuration configured in
riodicity2
accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

8 TddConfig. Frame type of the 1;2;0;0;null Managed Set this


frameType second period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
2 frame structure structure configuration accordance with
the frame
structure actually
used by the
operator. After
this parameter is
configured, it is
recommended
not to modify the
configuration.

9 TddConfig. Number of UL symbols 0 Managed This parameter


nrofUplink on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
Symbols2 second period of the structure configuration configured in
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

10 TddConfig. Number of DL symbols 0 Managed This parameter


nrofDownl on a special slot in the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame should be
inkSymbol second period of the structure configuration configured in
s2
frame structure accordance with
the actual frame
structure used by
the operator. It is
not
recommended to
modify the
parameter value
after it is
determined.

Figure 22 3+2ms Doubly Periodic Frame Structure (type 2) Feature Activation

28 - 51
Slot Format Configuration

Path: Planned Area > Smart Configuration > MO Editor > Selected NE > ManagedElement > NRRadioInfrastructure > NRPhysicalCellDU >
TddConfig

Table 25 2.5ms Periodic Frame DSUUU Structure Feature Activation

No. Parameter Parameter Name Configuration Parameter Path Configuration


ID Example Principle

1 TddConfig Duration of the first ms2p5[ms2p5] Managed This


.dlULTrans period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
missionPe structure structure configuration should be
riodicity1
configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

29 - 51
Slot Format Configuration

2 TddConfig Frame type of the first 1;2;0;0;0 Managed Set this


.frameTyp period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
e1 structure structure configuration accordance
with the frame
structure
actually used
by the
operator. After
this parameter
is configured,
it is
recommended
not to modify
the
configuration.

3 TddConfig Number of DL 10 Managed This


.nrofDown symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
linkSymbo slot in the first period structure configuration configured
ls1
of the frame structure and
determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

4 TddConfig Number of UL 2 Managed This


.nrofUplin symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
kSymbols slot in the first period structure configuration configured
1
of the frame structure and
determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

30 - 51
Slot Format Configuration

5 TddConfig Number of GP 2 Managed This


.gpNum symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
slot of the frame structure configuration should be
structure configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

6 TddConfig Whether to configure 0 Managed This


.frameTyp the second-period Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
e2Present frame type of the structure configuration should be
frame structure configured in
accordance
with the actual
frame
structure used
by the
operator. If the
operator uses
the dual
periodicity
frame
structure, set
this parameter
to 1.

Figure 23 2.5ms Periodic Frame DSUUU Structure Feature Activation

31 - 51
Slot Format Configuration

Path: Planned Area > Smart Configuration > MO Editor > Selected NE > ManagedElement > NRRadioInfrastructure > NRPhysicalCellDU >
TddConfig

Table 26 1ms Periodic Frame DS Structure Feature Activation

No. Parameter Parameter Name Configuration E Parameter Path Configuration


ID xample Principle

1 TddConfig Duration of the first ms1[ms1] Managed This


.dlULTran period of the frame Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
smissionP structure structure configuration should be
eriodicity1
configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

32 - 51
Slot Format Configuration

2 TddConfig Frame type of the 1;2;null;null;null Managed Set this


.frameTyp first period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
e1 frame structure structure configuration accordance
with the frame
structure
actually used
by the
operator. After
this parameter
is configured,
it is
recommended
not to modify
the
configuration.

3 TddConfig Number of DL 0 Managed This


.nrofDown symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
linkSymbo slot in the first period structure configuration configured
ls1
of the frame and
structure determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

4 TddConfig Number of UL 12 Managed This


.nrofUplin symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
kSymbols slot in the first period structure configuration configured
1
of the frame and
structure determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

33 - 51
Slot Format Configuration

5 TddConfig Number of GP 2 Managed This


.gpNum symbols on a special Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
slot of the frame structure configuration should be
structure configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

6 TddConfig Whether to configure 0 Managed This


.frameTyp the second-period Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
e2Present frame type of the structure configuration should be
frame structure configured in
accordance
with the actual
frame
structure used
by the
operator. If the
operator uses
the dual
periodicity
frame
structure, set
this parameter
to 1.

Figure 24 1ms Periodic Frame DS Structure Feature Activation

34 - 51
Slot Format Configuration

4.3.3.2 FR2 TDD Feature Activation Process

4.3.3.2.1 FR2 DDDSU Slot Format Configuration

Table 27 FR2 DDDSU Slot Format Configuration Feature Activation

No. Paramete Parameter Name Configuration Exa Parameter Path Configuration


r ID mple Principle

1 TddConfig Duration of the ms0p625[ms0p625] Managed This


.dlULTran first period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
smissionP frame structure structure configuration should be
eriodicity1
configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

35 - 51
Slot Format Configuration

2 TddConfig Frame type of the 1;1;1;2;0 Managed Set this


.frameTyp first period of the Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter in
e1 frame structure structure configuration accordance
with the frame
structure
actually used
by the
operator. After
this parameter
is configured,
it is
recommended
not to modify
the
configuration.

3 TddConfig Number of DL 10 Managed This


.nrofDow symbols on a Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
nlinkSym special slot in the structure configuration configured
bols1
first period of the and
frame structure determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

4 TddConfig Number of UL 2 Managed This


.nrofUplin symbols on a Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter is
kSymbols special slot in the structure configuration configured
1
first period of the and
frame structure determined in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

36 - 51
Slot Format Configuration

5 TddConfig Number of GP 2 Managed This


.gpNum symbols on a Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame parameter
special slot of the structure configuration should be
frame structure configured in
accordance
with the actual
frame
structure used
by the
operator. It is
not
recommended
to modify the
parameter
value after it is
determined.

The following figure shows the timeslot format configuration parameters for FR2. Currently, only the 0.625 ms-period frame format is available
for high-frequency timeslots.

Figure 25 Timeslot Format Parameter for FR2

4.3.3.2.2 FR2 DSUUU Dynamic TimeSlot Format Configuration

Table 28 FR2 DSUUU Dynamic Timeslot Format Configuration Function Activation

No. Paramete Parameter N Configuration Example Parameter Path


r ID ame

1 Replacea Board VBPd: 5G FR2 TDD ECPRI Managed Element/Equipment/Replaceable unit


bleUnit.f function 8NR(100M)[32834]
unctionM mode
ode

37 - 51
Slot Format Configuration

2 Replacea Board 5G Managed Element/Equipment/Replaceable unit


bleUnit.f function TNR(100M_DynamicFrame_3U)
unctionM mode [2181169153]
ode

3 TddConfi Number of 0 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame structure configuration


g.nrofDo DL symbols
wnlinkSy on a special
mbols1
slot in the
first period of
the frame
structure

4 TddConfi Number of 0 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame structure configuration


g.nrofUpl UL symbols
inkSymb on a special
ols1
slot in the
first period of
the frame
structure

5 TddConfi Number of 2 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame structure configuration


g.gpNum GP symbols
on a special
slot of the
frame
structure

38 - 51
Slot Format Configuration

6 TddConfi Frame type 1;2;0;0;0 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/Frame structure configuration


g.frameT of the first
ype1 period of the
frame
structure

7 SSBlock.l long bitmap. 00110000001100000011 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/CellDefiningSSB/SSB configu


ongBitma 000000110000001100000
p 01100000011000000110000

8 SSBlock.s SSBlock Area Coverage[11] Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/CellDefiningSSB/SSB configu


sblockBe beam
amCover coverage
Type
type

9 RachConf PRACH time- 178 Managed


igGeneric domain Element/NRRadioInfrastructure/NRPhysicalCellDU/PhyResourceConfigforBWPUL/Rach/rac
.prachCo resource
nfigIndex
configuration
index

10 SearchSp Start symbol 11100000000000 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/PhyResourceConfigforBWPDL


ace.moni for blind configuration/SearchSpace; Managed
toringSy detection in Element/NRRadioInfrastructure/NRPhysicalCellDU/PhyResourceConfigforBWPDL/The com
mbolsWit
a slot pdcch/SearchSpace
hinSlot

39 - 51
Slot Format Configuration

11 Tracking Number of 55;65;80;95;0;0;0;0;0;0;0;0;0;0;0;0 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/PhyResourceConfigforBWPDL


RsCfg.slo offset slots of Status Information Reference Signal/Single tracking RS resource configuration
tOffset CSI-RS
symbols
within a
configuration
period

12 Tracking CSI-RS beam 8;8;8;8;0;0;0;0;0;0;0;0;0;0;0;0 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/PhyResourceConfigforBWPDL


RsCfg.csi bitmap Status Information Reference Signal/Single tracking RS resource configuration
RsBeamB
itMap

40 - 51
Slot Format Configuration

13 PUCCHC Feedback 3;4;5;6 Managed Element/NRRadioInfrastructure/NRPhysicalCellDU/PhyResourceConfigforBWPUL


onfig.dlD delay configuration
ataToULA
CK

The DSUUU dynamic frame structure involves a lot of parameter changes. It is not recommended to manually configure the frame structure. It
is recommended that the DSUUU dynamic frame structure be generated by modifying the parameter set.
Detailed parameter configuration steps (Note: Unless otherwise specified, the path is: RAN Configuration Management> General Configuration
>MO Content >……)
The configuration steps are as follows:
Step 1: Configure the AAU function mode:
The parameter FunctionMode is configured as 5G TNR (100M_DynamicFrame_3U) [2181169153]
Path: ManagedElement>Equipment>ReplaceableUnit>FunctionMode

Figure 26 Timeslot Format Parameter for FR2

41 - 51
Slot Format Configuration

Step 2: Configure the VBP function mode:


The parameter FunctionMode is configured as VBPd: 5G FR2 TDD ECPRI mode 8NR (100 M) [32834]
Path: ManagedElement>Equipment>ReplaceableUnit>FunctionMode

Figure 27 Timeslot Format Parameter for FR2

Step 3: Modify the parameter suite on the UME:


The parameter BWPConfig_paramSuite is configured as mmWave_dsssu_100M[201]
path: RAN Configuration Management>Cell Management>ITRAN Multi BWP Config>BWPConfig_paramSuite

Figure 28 Timeslot Format Parameter for FR2

42 - 51
Slot Format Configuration

Step 4: Configure the long bitmap and the SSBlock beam coverage type on the UME:
The parameter longbitmap is configured as 0011000000110000001100000011000000110000001100000011000000110000.
Parameter ssblockBeamCoverType is configured as area coverage [11]
path: ManagedElement>NRRadioInfrastructure>NRPhysicalCellDU>CellDefiningSSB>SSBlock

Figure 29 Timeslot Format Parameter for FR2

Step 5: Modify the prach configuration on the UME:


The parameter prachConfigIndex is configured as 178
Path: ManagedElement>NRRadioInfrastructure>NRPhysicalCellDU>
PhyResourceConfigforBWPUL>RA>RachConfigGeneric>prachConfigIndex

Figure 30 Timeslot Format Parameter for FR2

43 - 51
Slot Format Configuration

Step 6: Modify the pdcch configuration on the UME:


Delete the BFR resources of the primary cell of the parameter searchSpaceId=2(Note: Delete the whole SearchSpaceId=2 content. In
principle, the BFR resources of searchSpaceId=2 will be automatically deleted after step 03).
Modify monitoringSymbolsWithinSlot of the primary cells of the parameter SearchSpaceId=2 =3 and 4 as 11100000000000
Path: ManagedElement >NRRadioInfrastructure>NRPhysicalCellDU>PhyResourceConfigforBWPDL>PDCCHconfig>SearchSpace

Figure 31 Timeslot Format Parameter for FR2

Figure 32 Timeslot Format Parameter for FR2

44 - 51
Slot Format Configuration

Step 7: Modify the pdcch configuration on the UME:


Modify the parameters of the secondary cell of the parameter SearchSpaceId =1.
monitoringSymbolsWithinSlot is 11100000000000
Path: ManagedElement>NRRadioInfrastructure>NRPhysicalCellDU>PhyResourceConfigforBWPDL>PDCCHconfig>SearchSpace

Figure 33 Timeslot Format Parameter for FR2

Step 8: Modify the TRS configuration on the UME:


The parameter slotOffset is configured as 55;65;80;95;0;0;0;0;0;0;0;0;0;0;0;0.
The parameter csiRsBeamBitMap is configured as 8;8;8;8;0;0;0;0;0;0;0;0;0;0;0;0.
Path: ManagedElement>NRRadioInfrastructure>NRPhysicalCellDU>PhyResourceConfigforBWPDL>CSIRS>TrackingRsCfg

Figure 34 Timeslot Format Parameter for FR2

45 - 51
Slot Format Configuration

Step 9: Modify the pucch configuration on the UME:


The parameter dlDataToULACK is configured as 3;4;5;6.
Path: ManagedElement >NRRadioInfrastructure>NRPhysicalCellDU>PhyResourceConfigforBWPUL>PUCCHConfig>dlDataToULACK

Figure 35 Timeslot Format Parameter for FR2

4.3.4 Feature Deactivation

If one of Periodic Radio Frame aboved is configured, the other Periodic Radio Frame will be automatically deactivated, and vice versa.

4.3.5 Test Method

Table 29 Test Method

Test Item Slot Format Configuration Slot Format Configuration(FR2 TDD)

Sub-Item Configure Section [](4.1.1 FR1 TDD Slot Format Configuration) Configure Section 4.1.2 FR2 Slot Format Configuration

Prerequisite Set Basic Parameters in accordance with Section 4.3.3.1 FR1 TDD F Set Basic Parameters in accordance with Section 4.3.3.2 F
eature Activation Process. R2 TDD Feature Activation Process.

46 - 51
Slot Format Configuration

Test Perform the following steps to do a test in accordance with the Perform the following steps to do a test in accordance
Procedure actual slot format: with the actual slot format:
1. Set relevant parameters in accordance with Section 4.3.3.1 FR1 T 1. Set relevant parameters in accordance with Section 4.3.
DD Feature Activation Process 3.2 FR2 TDD Feature Activation Process
2. Make sure that the tested cell is operating properly and the UE 2. Make sure that the tested cell is operating properly and
accesses the tested cell properly. the UE accesses the tested cell properly.
3. Record the signaling, and verify the parameters in SIB1 3. Record the signaling, and verify the parameters in SIB1
messages. messages.
4. Set relevant parameters in accordance with Section 4.3.3.1 FR1 T
DD Feature Activation Process (5 ms periodic).
5. Repeat step 3.

Expected Refer to Section 4.3.6 Provisioning Observation Refer to Section 4.3.6 Provisioning Observation
Result

4.3.6 Provisioning Observation

Expected result:
1. The cell is operating properly and the Qualcomm terminal accesses the network successfully.
2. The frame structure configuration is sent to the Qualcomm terminal through an RRCConnectionReconfiguration message.
(1)You can observe the configuration in the following path under the environment of NSA: QXDM > Filtered View >
RRCConnectionReconfiguration.
Key word: tdd_UL_DL_ConfigurationCommon
(2)You can observe the configuration in the following path under the environment of SA: QXDM > Filtered View >
SystemInformationBlockType1.
Key word: tdd_UL_DL_ConfigurationCommon

Figure 36 2.5 ms Doubly Periodic Frame Structure

Figure 37 5 ms Periodic Frame Structure

47 - 51
Slot Format Configuration

Figure 38 2.5 ms Periodic Frame Structure DDDSU

Figure 39 3+2ms Douby Periodic Frame Structure

48 - 51
Slot Format Configuration

Figure 40 2.5ms Periodic Frame Structure DSUUU

Figure 41 1ms Periodic Frame Structure DS

Figure 42 Commissioning and Observation of FR2 Slot Format Configuration

49 - 51
Slot Format Configuration

Figure 43 FR2 DSUUU Dynamic Timeslot Format Configuration

Figure 44 FR2 DSUUU dynamic timeslot format configuration provisioning observation

50 - 51
Slot Format Configuration

5 Related Counters, KPIs, and Alarms

5.1 Related Counters

This feature has no related counter.

5.2 Related KPIs

This feature has no related KPI.

5.3 Related Alarms

This feature has no related alarm.

6 Abbreviations
For the acronyms, refer to the abbreviations.

7 References
1.3GPP TS38.211,“Physical channels and modulation”
2. 3GPP TS38.213,“Physical layer procedures for control”

51 - 51

You might also like