SANITATION, PLUMBING DESIGN & INSTALLATION – SET 3

1. VERTICAL – By code definition, a stack 13. FALSE – The discharge from clinical
is always ____. sinks and conveyed to the building drain is
defined as a waste pipe.
2. BATHROOM – A room equipped with a
shower or bathtub is a ____. 14. THERMOSTATIC (TEMPERATURE
CONTROL) VALVE – A mixing valve that
3. COMBINATION WASTE AND VENT senses outlet temperature and
SYSTEM – A horizontal drain that is sized compensates for fluctuations in incoming
to provide free movement of air above the hot or cold water temperature is a ____.
flow line of the drain.
15. CROSS-LINKED POLYETHYLENE –
4. DEVELOPED LENGTH – The length PEX is defined as _____.
along the centerline of the pipe and
fittings is the ____. 16. BUILDING DRAIN – That part of the
lowest piping of a drainage system that
5. FLUSHOMETER TANK – A device receives the discharge from soil, waste
integrated within an air accumulator and other drainage pipes inside the walls
vessel that is designed to discharge a of the building and conveys it to a point 2
predetermined quantity of water of feet outside the building wall is a _____.
fixtures for flushing purposes.
17. CONTINUOUS VENT – A vertical vent
6. 1 - 45 degree and 1 - 45 degree – that is a continuation of the drain to which
The combination of fittings that may be it connects.
used to make an offset and is considered
a vertical pipe. 18. BUILDING SEWER THAT CONVEYS
BOTH SEWAGE AND STORM WATER –
7. POTABLE WATER – Water that is A combination building sewer is a:
satisfactory for drinking, culinary and
domestic purposes and that meets the 19. INVERT – The lowest portion of the
requirements of the Authority Having inside of a horizontal pipe is called the __.
Jurisdiction is referred to by this code as
20. CODE – A standard that is an
8. ACCESSIBLE – Fixture connections extensive compilation of provisions
that require the removal of an access covering broad subject matter.
panel for servicing are considered ____.
21. TRUE – Static pressure is pressure
9. THE CROWN WEIR TO THE TOP OF existing without any flow.
THE DIP OF THE TRAP – When
residential water meters become worn, 22. TRAP PRIMER – A device and system
they have the tendency to of piping that maintains a water seal in a
remote trap.
10. WET VENT – A vent that also serves
as a drain. 23. MAIN VENT – The principal artery of
the venting system to which branches
11. VERTICAL – A pipe that makes an may be connected.
angle not more than 45 degrees with the
vertical. 24. AUTHORITY HAVING
JURISDICTION – The organization,
12. TRUE – The restroom facilities in a office, or individual responsible for
private day care center are classified as enforcing the requirements of a code or
public use. standard.
SANITATION, PLUMBING DESIGN & INSTALLATION – SET 3

25. BUILDING SUBDRAIN – That 37. ATMOSPHERIC PRESSURE – Any


portion of a drainage system that does not pressure equal to that exerted by
drain by gravity into the building sewer. atmosphere.

26. CONDUCTOR – A pipe inside a 38. 325 F – The T rating limits the
building that conveys storm water from maximum temperature rise of ____ above
the roof to a storm drain, combined its initial temperature through the
building sewer, or other approved point of penetration on the no fire side.
disposal.
39. The definition of gray water is:
27. BOILER BLOWOFF – An outlet on a - Untreated wastewater that has not come
boiler to permit emptying or discharging into contact with kitchen sink or dishwater
of sediment. waste
- Untreated wastewater that has not come
28. WATER HAMMER ARRESTOR – A into contact with toilet waste
device designed to provide protection - Wastewater from bathtubs, showers,
against hydraulic shock in the building lavatories, clothes washers and laundry
water supply system. tubs
- ALL OF THE ABOVE
29. BACKWATER VALVE – A device
installed in a drainage system to prevent 40. TERTIARY TREATED NON-POTABLE
reverse flow. WATER – Reclaimed water systems are
defined as:
30. NEGATIVE PRESSURE / VACUUM –
Any pressure less than that exerted by 41. VENT CONNECTOR – That portion of
atmosphere. a venting system that connects a water
heater to a vent.
31. POSITIVE PRESSURE – Any
pressure greater than that exerted by 42. FLUSH VALVE – A device located at
atmosphere. the bottom of the tank for the purpose of
flushing water closets and similar fixtures.
32. HORIZONTAL PIPING EXTENDING
FROM A RISER TO A STATION OUTLET 43. HOUSE OR INLET SIDE OF THE
OR INLET – The service valve serves ___. FIXTURE TRAP – The overflow pipe from
a fixture shall be connected on the ____.
33. STANDARD – A document, wherein
the main text of which contains only 44. AIRBREAK - A physical separation,
mandatory provisions using the word which may be low inlet into the indirect
“shall” to indicate requirements, is best waste receptor from the fixture, appliance
described as a ____. or device indirectly connected.

34. TRUE – Unsanitary and insanitary 45. VERTICAL – A pipe that makes an
share the same meaning. angle of 45 degrees from the vertical.

35. BOTTOM – When a backflow 46. WATER PIPING – The definition for
prevention device does not bear a critical the work “Stack” does not include ____.
level marking, the part of the device that
shall constitute the critical level is the __. 47. TRUE – A permanently installed
mechanical device, other than an ejector,
36. BUILDING SUPPLY – The pipe from for removing sewage or liquid waste from
the source of supply to a building or a sump is called a sewage pump.
structure is the _____.
SANITATION, PLUMBING DESIGN & INSTALLATION – SET 3

48. COPPER ALLOY – Screws or bolts for 62. PUBLIC TOILET ROOMS – Drinking
securing floor-mounted fixtures shall be _. fountains shall not be installed in ______.

49. A UTILITY SPACE OR ACCESS 63. 30” – Water closets set side by side
PANEL – Fixtures having concealed slip shall be no closer than __ center to center.
joint connections shall be provided with __
64. AUTOMATIC IN OPERATION –
50. TOILETS – Gray water is untreated Tanks flushing more than one urinal shall
wastewater that has not come into contact be _____.
with waste from which of the following?
65. FLUSH TANKS – Automatically
51. 1-1/2 inches – The diameter of a controlled flushometer valves may be
waste outlet and fixture tailpiece for a substituted for ____.
bathtub shall not be less than ____.
(Inner diameter) 66. MADE WATERTIGHT – The joint of a
wall-hung lavatory, where is in contact
52. TRUE – The connection of a with the wall, shall be ____.
dishwasher drain directly to the
continuous waste is a code violation. 67. FLOOR DRAINS & SHOWER DRAINS
– In the construction of “on-site built-up
53. 15” – The minimum distance from a shower receptors”, watertight shower pan
side wall to the center of a water closet is linings shall be installed, over a smooth
and solid sub-base, with a pitch to the
54. 24” – The distance between the “weep holes” of ________ inch per foot.
center of two urinals cannot be less than
68. METAL SUPPORTING MEMBERS –
55. 1 – Manually controlled flushometer Wall-hung lavatories shall be supported by
valves shall be used to flush not more ____.
than ___ urinal(s).
69. 1 ¼ inches – The tailpiece diameter
56. VACUUM BREAKER – A water supply for lavatories shall not be less than ____.
to a urinal shall be protected by an
approved _____. 70. 2% - Gutters in public shower rooms
shall be sloped not less than ___.
57. PROHIBITED - Trough urinals shall
be ____. 71. ¼ - Strainers having waterway areas
at least equivalent to the area of their
58. 30” – With two noted exceptions, all tailpiece are required for ___.
shower compartments and receptors shall
be capable of encompassing a ____ 72. PRESSURE BALANCE TYPE &
diameter circle. THERMOSTATIC MIXING VALVE TYPE
– Showers and tub-shower combinations
59. TO COMPLY WITH ACCESSIBILITY shall not be provided with individual
STANDARDS – The curb or threshold of a control valves of the _______.
shower compartment may be eliminated.
73. 24” – The clear span in front of any
60. 2, 9 – A dam or threshold be less than water closet or bidet shall not be less than
__ inches or exceeding __ inches in depth ___.
were measured from the top of the dam
or threshold to the top of the drain. 74. 110 – Maximum hot water
temperature discharging from a bidet shall
61. SOLDERED or BRAZED - Joints in be limited to ___ ◦F.
copper shower pan liner shall be ____.
SANITATION, PLUMBING DESIGN & INSTALLATION – SET 3

75. TOP OF THE CLOSET RING – Closet


bends or stubs shall be cut off so as to
present a smooth surface, even with the
____.

76. A CARRIER FITTINGS – Wall-


mounted water closets shall be securely
bolted to ____.

77. FLANGES – Fixture connections


between drainage pipes and water closets
shall be made with approved ____.

78. A domestic dish-washing machine


shall discharge indirectly through an air
cap fitting into a ____.
a. wye branch fitting on the tailpiece of a
kitchen sink
b. waste receptor
c. dishwasher connection of a food waste
disposer
d. ALL OF THE ABOVE

79. AIR GAP – The water supply to a


bathtub and whirlpool bathtub filler valve
shall be protected by an ____.

80. CLEARLY IDENTIFIED – The path of


travel to an emergency eyewash shall be _