General Inputs

Span 4.87 m
Total Length 37.18 m
Rise 1m
Height to Eaves (h) 8.53 m
StrClass GENERAL
RoofType Unit: kN,m
Wall Type
Thickness(mm)
Roofing Type
Roof Access
Purlin Spacing m
Girt Spacing m

Wind Load Input


Wind Speed Zone 4 47 m/s
Permeability (%) 0.04
Terrain Type
Height Above Ground (z) 8.53 m
k3 1 Flat Land
k4 1 Non Cyclonic
Kd 0.9
Ka 1
Kc 0.9
Outputs (in kN/m2)
Dead Load Roofing 0.131 kN/m2
Wall kN/m2
Fixings 0 kN/m2
Services 0 kN/m2
Live Load Live Load 0.75 kN/m2
Note: +ve mean towrds the member and -ve means away from the member
Note: Internal Coefficient Pressure needs to be added +,- in Load Comb
Wall A B C D Internal
0 0.752 -0.268 -0.644 -0.644 0.215
Wall

90 -0.537 -0.537 0.752 -0.107 0.215


180 -0.268 0.752 -0.644 -0.644 0.215
270 -0.537 -0.537 -0.107 0.752 0.215
Roof E F G H Internal
Pitched Roof

0
90
180
270
Roof H L Internal
0 -1.074 -0.537 0.215 Wly-
MonoSlope

90 -1.074 -1.074 0.215 wlx- wlx+


90 -0.537 -0.537 0.215

180 -0.537 -1.074 0.215 wly+


270 -1.074 -1.074 0.215
270 -0.537 -0.537 0.215
WLY+ 0.752 -0.268 -0.644 -0.644 0.215
WlX+ -0.537 -0.537 0.752 -0.107 0.215
wlY- -0.268 0.752 -0.644 -0.644 0.215
wlX- -0.537 -0.537 -0.107 0.752 0.215

WLY+ -1.288 -1.288 -0.429 -0.429 0.215


WlX+ -0.859 -0.644 -0.859 -0.644 0.215
wlY- -0.429 -0.429 -1.288 -1.288 0.215
wlX- -0.859 -0.644 -0.859 -0.644 0.215

-1 -0.5 0.2

-1 -1 0.2
-0.5 -0.5 0.2

-0.5 -1 0.2
-1 -1 0.2
-0.5 -0.5 0.2

14.6395
10.979625

wind Direction a b c d x
Wx+ 0 -0.9 -0.6 -0.4 -0.3 -0.3
Wx- 180 -0.3 -0.3 -0.3 -0.4 -0.6
WY+ 90 -0.8 -0.8 -0.8 -0.8 -0.8
WY- 270 -0.8 -0.8 -0.8 -0.8 -0.8

wind Direction a b c d x
Wx+ 0 -0.966217 -0.644144 -0.42943 -0.322072 -0.322072
Wx- 180 -0.322072 -0.322072 -0.322072 -0.42943 -0.644144
WY+ 90 -0.858859 -0.858859 -0.858859 -0.858859 -0.858859
WY- 270 -0.858859 -0.858859 -0.858859 -0.858859 -0.858859
A B C D
0.7 -0.25 -0.6 -0.6 0.2
-0.5 -0.5 0.7 -0.1 0.2
-0.25 0.7 -0.6 -0.6 0.2
-0.5 -0.5 -0.1 0.7 0.2
E F G H
-1.2 -1.2 -0.4 -0.4 0.2
-0.8 -0.6 -0.8 -0.6 0.2
-0.4 -0.4 -1.2 -1.2 0.2
-0.8 -0.6 -0.8 -0.6 0.2

z internal
-0.3 -0.2
-0.9 -0.2
-0.8 -0.2
-0.8 -0.2

z internal
-0.322072 -0.214715
-0.966217 -0.214715
-0.858859 -0.214715
-0.858859 -0.214715
Span of Truss = 4.87 m
Length of Structure = 37.18 m
Height of Structure = 1.52 m
Height to Eaves = 8.53 m
Class of Structure = GENERAL [Table-1 Sec. 6.3.1]
Basic Wind Speed (Vb) = 47 m/s
Permeability of Structure = 0.04
Height Above Ground = 8.53 m

Design Wind Speed (Vz)


Vz = Vb k1 k2 k3 k4 [Sec. 6.3]

where ;
Vz = design wind speed at height z, in m/s
Vb = basic wind speed, m/s [Sec. 6.2]
k1 = probability factor (risk coefficient) [Sec. 6.3.1]
k2 = terrain roughness and height factor [Sec. 6.3.2]
k3 = topography factor [Sec. 6.3.3]
k4 = importance factor for the cyclonic region [Sec. 6.3.4]

Vb = 47 m/s
k1 = 1
k2 = 1 Terrain Type : 0 category 2
k3 = 1 Flat Land
k4 = 1 Non Cyclonic

Vz = Vb k1 k2 k3 k4
= 47 m/s

Wind Pressure

pz = 0.6 Vz2 [Sec. 7.2]

where ;
pz = wind pressure at height z, in N/m2
Vz = design wind speed at height z, in m/s

pz = 0.6 Vz2
= 1325.40 N/m2
= 1.33 kN/m2

Design Wind Pressure

pd = Kd Ka Kc pz [Sec. 7.2]

where ;
pd = design wind pressure
Kd = wind directionality factor
Ka = area averaging factor
Kc = combination factor
Kd = 0.9
Ka = 1
Kc = 0.9

pd = Kd Ka Kc pz
= 1.07 kN/m2 1.07