Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Problems from subcontractor during

Mechanical fixation and installation marble


1
At the beginning there were bad
workmanship at Alignment during
installation C channel

Subcontractor must adjust alignment for


fixation of C channel before marble
installation
2
Using Z bracket 5 cm instead of
3 cm

That lead to duplicate L bracket


because cavity have been more than
16 cm
3

Brocken of Anchor bolts during Torque

Consultant need Chemical and Mechanical test


for Anchor bolts
Installation at
Site
4
Using double arm flat heat bolt not
compatible with calculation design
approved
S.D & Calculation

Need RFP show double arm Safe


5
Subcontractor using Arm flat head
bolt to fixation small tiles and that
not compatible with S.D

Need any tiles fixation with 4 points


according to S.D and calculation
Installation at S.D
Site
6

Fixation of 1st course not approved


from consultant

Need to make detail that have been


approved from ECG

Installation at Site ECG Proposal


7

Fixation bens without plastic cover that lead to


demolish the tile when need to change it

Need to install with Plastic Cover