Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 13

OBSERVATION-

1 to 7 OT Located in the first floor and GYNAE OT , DERMA OT , CTVS OT is located in


the 2nd floor.

No. of Operation theater-

1. 1 NEURO OT
2. 1 ENT OT
3. 1 LAPROSCOPY OT
4. 1 PEDIATRIC OT
5. 1 EYE OT
6. 1 ORTHO OT
7. 1 UROLOGY OT
8. 2 GYNAE OT
9. 1 DERMA OT
10. 1 CTVS OT

DATA -Number of cases-

Ortho OT – 01

G/Surgery- 03

Neuro – 01

ENT – 03

EYE- 06

Emergency cases- 1

Total – 15 cases

Filled IPD Patient Feedback Form .


STAFFING – 1 HOD (Anaesthesiologist)
1 OT Incharge

1 Register maintenance Incharge

20 OT Technicians

1 ward boy

1 ward aaya

2 house keeping

OT Registers-
1. General Surgery
2. Paediatric Surgery
3. ENT Surgery
4. Ortho Surgery
5. Day Care OT Registers
6. Fumigation Registers
7. Instrument Maintenance Registers
8. Anaesthesia Registers
9. Case Entry Registers
10. House Keeping Registers
11. Implant-Register

DATA -Number of cases-

Ortho OT – 01

G/Surgery- 05

Neuro – 01

ENT – 05

EYE- 08

Emergency cases- 03

ECT (Electro current tharaphy) - 03

Total – 26 cases

Major Equipment and Appliances


1. Heart lung machine
2. Cell save
3. ECMO ( extracorporeal membrane oxygenation)
4. Central monitors
5. IABP( intra-aortic balloon pump)
6. Channel monitor
7. Anaesthesia machines
8. Defibrillator
9. Flash steriliser
10. Deep freezer (for frozen section)
11. Instrument trolleys
12. C–arm fluoroscopy machine
13. Operating tables
14. Suction apparatus
15. Shadow less ceiling lamp
16. Shadow less pedestal lamps
17. Close-circuit TV camera
18. Operating microscope
19. Pulse oxy meter
20. Ventilator

 HEPA Filter is Available (high efficiency particulate air)


 OT table Sheet name – THERMO SHEET

( This sheet is maintaining the patient body temperature)

 HUMADITY Less than 50%C


 TEMPRATURE- 15%C

STAFFIING –
6 to 7 Staff

HOD- 1

OT in charge - 1

Anaesthesia Technicians – 2

Scrub Nurse- 2

Ward boy-1

Ward Aaya – 1

Housekeeping staff -2
DATA -Number of cases-

Ortho OT – 01

G/Surgery- 03

Neuro – 0

ENT – 07

EYE- 06

SPINE- 01

Emergency cases- 0

Total – 18 cases

Document used in OT-


 Histopathology, Report
 Progress Note
 Operation List
 Medicine Requirement
 Anaesthesia chart
 Consent form

DATA -Number of cases-

Ortho OT – 04

G/Surgery- 05

Neuro – 0

ENT – 06

EYE- 06

UROLOGY- 01

ECT- 03

GYN-01

Emergency cases- 04

Total – 1 cases
Service lines:-
 Oxygen
 Nitrous oxide
 Compressed air
 Suction/vacuum

Colour Codes-
Oxygen- White

Nitrous oxide - Blue

Compressed air - Black

Suction/vacuum - Yellow

OPREATION THEATER LIGHT-


Shadowless Light

1000 lx
ZONING
ZONE 1 – PROTECTIVE - reception, waiting, trolley bay, pre anaesthesia room, change
room.

ZONE 2 – CLEAN AREA – pre operative, recovery, plaster room, staff lounges, anaesthesia
room store room, stores

ZONE 3 – STERILE AREA – operating room, scrub room, anaesthesia room, setup room

ZONE 4 – DISPOSAL AREA – dirty utility, disposal corridor

Types of Surgeries
1. Emergency Surgeries
2. Elective Surgeries
3. Major Surgeries
4. Minor Surgeries
5. Day-care Surgeries

Service; Pipeline Testing


 Blowdown
 Initial Pressure Test
 Standing Pressure Test
 Piping Purge
 Cross – Connection Test

DATA -Number of cases-


Ortho OT – 01

G/Surgery- 06

Neuro – 0

ENT – 05

EYE- 08

PAEDIA- 01

GYN.-01

SPINE- 01

Emergency cases- 1

Total – 24 cases
OT CLEANING-
MOP with 1% Sodium Hypo chloride Solution

Bacilocid Spray

Fumigation Solution

Formalin – 40% (500ml Clean Water)

BIOMEDICAL WASTE IN OPERATION THEATRE

DATA -Number of cases-


Ortho OT – 02

G/Surgery- 01

Neuro – 0

ENT – 03

EYE- 05

Emergency cases- 1

Total – cases 12
Pre-Operative And Post-Operative Ward
Pre – Operative –

6- beds

Staffing- Nurse- 1
Ward Aaya- 1

Housekeeping- 1

Post- Operative-

10- Beds

Staffing- Nurse- 3

Ward Aaya – 1

Housekeeping- 1

DATA -Number of cases-


Ortho OT – 01

Paideia- 01

Spine- 01

G/Surgery- 06

ENT – 05

EYE- 08

Gynae- 01

Emergency cases- 01

Total – cases 24
Operation Theatre facilities -
 Duty doctors rest area
 Separate changing rooms with lockers for male and female doctors
 Nurses changing room
 OT office
 Anaesthetics Store Room
 Washing Area
 Washrooms

DATA -Number of cases-

Ortho OT – 04
Urology- 07
ENT – 04
EYE- 08
G/Surgery- 05
ECT- 03

Total – cases -31

GYNAE OPRATION THEATER-

It is located in 2nd Floor

Facilities
• Duty doctors rest area

• Separate changing rooms with lockers for male and female doctors

• Nurses changing room

• OT office

• Anaesthetics Store Room

• Washing Area

• Washrooms
Staffing –
Operation theatre technician – 3

Ward Aaya – 1

Housekeeping – 1

 Equipment and appliances as it is all 1st floor Operation theatres

DATA -Number of cases

Ortho OT – 03

Urology- 04

ENT – 04

G/Surgery- 06

ECT- 03

Emergency- 01

Total cases- 21

DATA – ( GYNAE OPERATION THEATER)

DATE- 26-09-2022

Number of cases is – 01

DATE- 27-09-2022

Number of cases is – 01

DATE- 28-09-2022

Number of cases- 0

DATE- 29-09-2022

Number of cases is – 04

DATE- 30-09-2022

Number of cases is- 04

DATE- 01-10-2022
Number of cases is- 03

DATE- 03-10-2022

Number of cases- 01

DATE- 04-10-2022

Number of cases is – 01

DATE- 06-10-2022

Number of cases is - 01

 RECOMMENDATION

 HEPA FILTER should be used in Operation theatre.


 Majority of the Equipment are damage and must be replaced.
 Replacement of LED APRON as all are damage.
 OT Table Light are damage must be replaced.
 Some Gawn damage is worth replacing.

You might also like