Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Project:

Client: Contractor: TWO BRAND NEW SOLAR GAS TURBO COMPRESSOR


S.O.C. UNA E&C PACKAGE EPC CONTRACT
Document Title:
COMPRESSOR SKID FOUNDATION - CALCULATION

Document Number: Revision:


2986-ESP-LRU-CI-CAL-0001 0

TABLE OF CONTENTS
1.0 INTRODUCTION ............................................................................................................. 4
2.0 REFERENCE DOCUMENTS .......................................................................................... 4
2.1 INDUSTRY CODES AND STANDARDS ............................................................. 4
2.2 PROJECT SPECIFICATIONS AND STANDARDS ............................................. 4
3.0 MATERIALS ................................................................................................................... 5
4.0 DESIGN PHILOSOPHY .................................................................................................. 5

APPENDIX 1 – COMPRESSOR FOUNDATION DESIGN -CALCULATION.........................1-18


APPENDIX 2 – FOUNDATION DRAWINGS – FORMWORK & REINFORCEMENT ..............1-3
APPENDIX 3– EQUIPMENT LAYOUT ...................................................................................1-2
APPENDIX 4 – LOADS FROM VENDOR DRAWING.............................................................1-2
APPENDIX 5 – ANCHOR BOLT CATALOGUE FROM VENDOR ..........................................1-3

2986-ESP-LRU-CI-CAL-0001 Page 3 of 5
Project:
Client: Contractor: TWO BRAND NEW SOLAR GAS TURBO COMPRESSOR
S.O.C. UNA E&C PACKAGE EPC CONTRACT
Document Title:
COMPRESSOR SKID FOUNDATION - CALCULATION

Document Number: Revision:


2986-ESP-LRU-CI-CAL-0001 0

1.0 INTRODUCTION
This document covers the design calculation for Solar Gas Turbo Compressor in Train A & B in
Solar Turbo Compressor Package project located in North Rumaila field-Iraq. The Scope of this
design calculation is to highlight the design philosophy, machine loads and adequacy of proposed
foundation system along with the size and reinforcement requirement of the foundation for the
compressor.

The compressor is centrifugal type supported on block type foundation. Compressor loading data,
foundation pad location, anchor bolt location etc. is provided by vendor “Solar Turbines” in Drg
No: 2986-STI-EGT-ME-DRG-0001 (Rev-B).

2.0 REFERENCE DOCUMENTS


The following reference documents shall be applied for the design.

2.1 INDUSTRY CODES AND STANDARDS


ACI 351.3R-04 : Foundations for Dynamic Equipment

ACI 318-05 : Building Code Requirement for Structural


Concrete
ASCE 7-05 : Minimum Design Loads for Buildings and Other
Structures

2.2 PROJECT SPECIFICATIONS AND STANDARDS


2986-ESP-LRU-CI-SPC-00001 Rev-1 : Civil and Structural Design Basis

2986-ESP-LRU-CI-SPC-00008 Rev-0 : Reinforced Concrete Specification

2986-STI-EGT-ME-DRG-0001 Rev-B : Mechanical Interface Drawing (GA)

PIL 181 Rev-3 : Package Tie-Down Options

2986-ESP-LRU-CI-CAL-0001 Page 4 of 5
Project:
Client: Contractor: TWO BRAND NEW SOLAR GAS TURBO COMPRESSOR
S.O.C. UNA E&C PACKAGE EPC CONTRACT
Document Title:
COMPRESSOR SKID FOUNDATION - CALCULATION

Document Number: Revision:


2986-ESP-LRU-CI-CAL-0001 0

3.0 MATERIALS
Material specifications shall be as follows:

a) Concrete:

Reinforced Concrete : f'c = 30/37 Mpa

Lean concrete : f'c = 12/15 Mpa

Reinforcement : Deformed bar conforming to ASTM 615M Grade 60

b) Anchor Bolt : 1 ½” Deco brand heavy-duty adjustable anchors (by

Vendor)

4.0 DESIGN PHILOSOPHY


Design of compressor foundation shall be carried out as per following criteria:

1) Weight of foundation is kept more than 3 times the total weight of machine.

2) The combined center of gravity of the machine foundation system shall, as far as possible,
pass through the center of area of the block foundation.

3) The soil stress below foundations shall not exceed 50% of the net allowable soil bearing
capacity.

4) The stability checks for foundation shall be carried out based on the allowable stress design
load combinations.

5) The anchor bolt shall be designed based on the Strength design (LRFD) load combinations.

6) The Static weight of the equipment is considered as the Empty Weight (De) in design.

7) For Operating Weight (Do) the summation of static weight and dynamic weight is considered.

2986-ESP-LRU-CI-CAL-0001 Page 5 of 5

You might also like