FLIM Specifications

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

From Eye to Insight

No QU-0031719-D
Date 10/18/2019 QUOT
QUOTA
ATION
Valid Until 10/31/2019

Max
Max-Planc
-Planck-Institut
k-Institut für Sales Contact
Kolloid- u. Grenzflächenforschung Dr. Martin Fritsch
Am Mühlenberg 1 Phone: +49 174 1946 153
14476 Golm Fax: +49 6441 294 013
Martin.Fritsch@leica-microsystems.com

Customer Care Contact


Herr Christian Kloes
Phone: 06441-294211
Fax: 06441-294013
Christian.Kloes@Leica-Microsystems.com

Verhandlungsverg
erhandlungsvergabe
abe MPI für K
Kolloid-
olloid- und Grenzfläc
Grenzflächenfor
henforsc
schung:
hung:
FALCON FLIIM Aufrüstung - Update SP8

Die Angebotskonfiguration erfüllt alle tec


technisc
hnischen
hen Spezifik
Spezifikationen
ationen des L
Leistungsverz
eistungsverzeic
eichnisses
hnisses

Leica Upgrade P
Promotion
romotion P
Pac
ackkage F
FALCON
ALCON
MP
Scan head Upgrade for SP8 Flexible
-SScan
can head electronics upgrade
-FFALCON
ALCON FLIM, FLIM-FRET
- Exper
Expertt CUD
CUDA AW Workstation,
orkstation, including OS Win 1
10
0
SN: SP8 81810
0 0 0 01654

Scan Head Upgrades

# Items Quantity

Scan head Upgrade for SP8 Flexible


1
1580
5800960
09601
1

TCS SP8 systems can be upgraded on site with new state of the ar
artt scanning electronics
10 and this opens new possibilities for y
you:
ou:

- Linear scanning features are available with new Electronics and LA


LASX
SX =3.4. linear

www.leica-microsystems.com 1|5
From Eye to Insight QU-0031719-D

# Items Quantity

scanning 1 Hz to 1
180
800Hz,
0Hz, duty cycle max. 85%

- Examples for increased imaging bandwidth:


8kHz: 2496x2496, 3 cch,
h, 8-bit simultaneous 1
12kHz:
2kHz: 1
1664x1
664x1664,
664, 3 cch,
h, 8-bit simultaneous

- more computation power


powerss

Section Net Subtotal EUR 19,40


9,400.04
0.04

Upgrade F
FALCON
ALCON FCS

# Items Quantity

SMD Excitation Multiphoton


1
1580
58005225
05225

FLIM Excitation pac


packk age for MP excitation A pac
packk age needed to generate a
20 sync
synchronization
hronization signal from MP laser
lasers.
s. The sync
synchronization
hronization signal is a prerequisite for
lifetime based measurements. The pac packk age comprises following main constituents:
-TTrigger
rigger diode assembly for generation of the syncsynchronization
hronization signal
- Optical coupling MP excitation
-SSof
oftw
tware
are controlled selection of MP excitation w wavelength
avelength

High speed data link


1
1580
58005444
05444
30
The High Speed Data Link enables the high-speed data transmission between
microscope and PC. It is required for FLIM and FCS.

TCS SP8 FFALCON


ALCON
1
1580
58005406
05406

TCS SP8 F FALCON


ALCON (F (FAst
Ast Lifetime CONtrast) consists of two main par parts.
ts. 11.. Electronics and
interface for sync
synchronization
hronization of FLIM excitation sources with the detection logic. 2. LA LASS
X FLIM solution for ultrafast acquisition, processing and analysis of FLIM images. The
acquisition sof
softw
tware,
are, fully integrated with LA LASS X, enables FLIM with an anyy imaging
workflow (time lapse, 3D, lambda scan, combination with mosaic imaging (LA (LAS SX
Navig
Navigator)
ator) possible). It is possible to combine multiple detector
detectorss to increase the
acquisition speed. The sof softw
tware
are displays the fastFLIM (mean ar arri
rival
val time) image and the
photon/pulse histogram in real time. It deri derives
ves the IRF (instrument response function)
40 and includes n- Exponential R Recon
econv volution and n-Exponential T Tail
ail fit
fitting
ting with up to 5
components, dead-time cor correction
rection and incomplete decay fit fitting
ting algorithm. The analysis
can be done on ROIs as well as on series of images (time lapse, z-stac z-stack,k, mosaic) whic
whichh
can analyz
analyzed
ed as a complete dataset or separated into images. Binning for pixels or for
the lifetime scale is enabled as well as time-gtime-gating.
ating. T
Too allow for highest lifetime
precision, Photon Filter
Filterss can be applied. In single pixels the sof softw
tware
are fits and displays
lifetimes and it can separate components according to lifetime, leading to multiple
channel display
display.. The sof
softw
tware
are has the display option "free", where an any y fit
fitted
ted parameter
parameterss
of cchoice
hoice (e.g. lifetime-amplitudes) can be displayed on a rainbow scale. LA LASS X FLIM
includes the FLIM-FRET analyz analyzer
er.. The analysis sof
softw
tware
are pro
provides
vides the FLIM-FRET
efficiency map, the apparent FRET efficiency image and a binding map. All fit fitting
ting options

www.leica-microsystems.com 2|5
From Eye to Insight QU-0031719-D

# Items Quantity

(Overall Decay
Decay,, ROIs, single pixel fit, separation into cchannels)
hannels) are also available with the
pat
pattern-matc
tern-matching
hing algorithm, selecting a pat
pattern
tern by cchoosing
hoosing a ROI in the image or in the
Decay DiDiver
versity
sity Map. In combination with TCS SP8 FCS TCS SP8 F FALCON
ALCON enables FLCS
(Fluorescence Lifetime CorCorrelation
relation Spectroscopy) experiments.

Section Net Subtotal EUR 44,759.60

Service and CUD


CUDAAW
Workstation
orkstation

# Items Quantity

Service installation
50 3
9I_D
9I_DAAY_INS
Y_INST_UPGR
T_UPGR

High Brilliance Monitor flat


1
1580
580031
03151
51

- Display siz
size
e (diagonal): 80 cm (31,5 inc inch)
h)
- R
Resolution
esolution (nati
(native):
ve): 4K UHD (3840 x 21 2160
60 @ 60 Hz)
- Contrast ratio: 1 130
300:1
0:1 static, 50
5000 0 0 0 0:1 dynamic
- Display: IPS with LED-Bac
LED-Backlight
klight
- Angle: 1 178°
78° horiz
horizontal,
ontal, 1
178°
78° ver
vertical
tical
60 - P
Propor
roportion:
tion: 116:9
6:9
- Display range (metric): 69,73 x 39,22 cm
- Brightness: 350 cd/m²
- T
Type
ype of display input: 1 DisplayP
DisplayPor ort,
t, 1 mini DisplayP
DisplayPor
ort,
t, 1 HDMI, 1 USB T
Type-C
ype-C
- P
Point
oint spacing: 0,1
0,181
81 mm
- R
Reaction
eaction time: 1 144 ms grey to grey

Mandatory for all F


FALCON
ALCON systems

Exper
Expertt CUD
CUDAAW
Workstation
orkstation
1
1580
580031
03152
52

High P Power
ower HPZ6G4 W Workstation
orkstation with Windows 110
0PProfessional
rofessional (64 bit) operating
system. A high-performance professional graphics card with advanced P Pascal
ascal GPU
arc
architecture
hitecture addresses the highest demands in 3D visualization and computing
acceleration. The PPascal
ascal GPU is a parallel processor that serves as a computing
accelerator for scientific researc
research.
h.

70 - IN
INTEL
TEL 61
6134
34 XEON3.2 8C
- 1
192
92 GByte RAM
- NVIDIA Quadro GP1
GP1000 1
16GB
6GB R
Reference
eference GPU (3584 K
Kerne)
erne)
- 256 GB SSAATA SSD
- 6TB SSA
ATA Enterprise
- 2TB M.2 SSD
- 1
10
0 GBit IN
INTEL
TEL X71
X710
0 Network Adapter
- Thunderbolt 3
- 9.5mm Slim Blu-ray WWriter
riter 1st ODD
- K
Keyboard
eyboard and mouse

www.leica-microsystems.com 3|5
From Eye to Insight QU-0031719-D

# Items Quantity

- Windows1
Windows10 0 loT Enterprise 20
201
16 L
LTSB
TSB ePKEA The specification for the PC may cchange
hange
due to tec
technical
hnical inno
innovations.
vations.

Section Net Subtotal EUR 26,1


26,196.1
96.155

Application T
Training
raining

# Items Quantity

2 Days CLSM Application T


Training
raining
80 1
9I_CLSM_APPLIC2

Section Net Subtotal EUR 2,0


2,003.85
03.85

Quotation T
Totals
otals
Product Net T
Total
otal EUR 92,359.64

Grand T
Total
otal Excluding T
Taxes
axes EUR 92,359.64

VAT (1
(19.0
9.00%)
0%) 1
177,548.33

Grand T
Total
otal Including T
Taxes
axes EUR 109,907
09,907.97
.97

www.leica-microsystems.com 4|5
From Eye to Insight QU-0031719-D

Sales Contact
Terms and Conditions
Dr
Dr.. Mar
Martin
tin F
Fritsc
ritsch
h
Cur
Currency
rency:: EUR Phone: +49 1 17
74 11946
946 1
153
53
Payment T Terms
erms:: 114
4TTage
age 2% 30 TTage
age net
netto
to Fax: +49 6441 294 0 01
13
Shipping T Terms
erms:: CPT - frei V
Verwendungsstelle
erwendungsstelle Mar
Martin.F
tin.Fritsc
ritsch@leica-microsystems.com
h@leica-microsystems.com
Lead TTime
ime:: 23 lbl.workingdays
Valid Until
Until:: 1
10/31/20
0/31/20119 Customer Care Contact
Her
Herrr Christian Kloes
Phone: 06441
06441-29421
-294211
1
Fax: 06441
06441-2940
-29401
13
Christian.Kloes@L
Christian.Kloes@Leica-Microsystems.com
eica-Microsystems.com

Es gelten unsere allgemeinen V Verk


erkaufs-
aufs- und Lieferbedingungen (A
(AGB’
GB’s)
s) sowie unser
Enduser
Enduser-Liz
-Lizenzver
enzvertrag
trag (EULA), die Sie auc
auch
h unter:
www
www.leica-microsystems.com/compan
.leica-microsystems.com/company/sales-service-terms-and-conditions
y/sales-service-terms-and-conditions finden können.
Preise: Alle Einzelpreise verstehen sich exklusiv MwSt.

Es gilt der zum Zeitpunkt der Lieferung gültige Mehrwertsteuersatz.


Die Zahlungen sind ohne jeden Abzug zu leisten und zwar: 100 % des Warenwertes sowie die
anteilige Mehrwertsteuer nach Lieferung.

Aufstellung: Installationskosten von Zusatzeinrichtungen, die nicht zusammen mit einem


Grundgerät bestellt wurden, werden nach Aufwand in Rechnung gestellt.

Kundendienst: Es steht Ihnen ein gut organisierter, dezentraler Kundendienst zur Verfügung.

Gew
Gewährleistung:
ährleistung: Die Gewährleistung beträgt ein Jahr ab Installationsdatum.

Leica Mikrosysteme V Ver


ertrieb
trieb GmbH · Ernst-L
Ernst-Leitz-Straße
eitz-Straße 1
17–37
7–37 · D-35578 W
Wetzlar
etzlar
T +49 (0)64 41 29-40 0
000 · F +49 (0)64 41 29-41 55
GmbH mit Sitz in WWetzlar
etzlar · Amtsgeric
Amtsgerichtht W
Wetzlar
etzlar HRB 5464
UID-Nr
UID-Nr.. DE 81
811
1140297 · St.Nr
St.Nr.. 0202251
02022516606
6606 Finanzamt Giessen

Gesc
Geschäf
häftsführer:
tsführer: Markus Lusser | Melanie Hammer
Hammersc
schmidt-Broman
hmidt-Broman | Markus Limberger

Deutsc
Deutsche
he Bank A
AG,
G, F
Frankfur
rankfurtt · BLZ 50
500
0770
00 1
10
0 · Kto. 04051
040510
00 0
000
IBAN DE43 50
5007
07 000
010 00040
040 51
510 00 0
000

Ver
ertraulic
traulich:
h: Nur zur kundeninternen V
Verwendung
erwendung

www.leica-microsystems.com 5|5

You might also like