Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

WIRING FOR ARCUBE ELEVATOR

CONTROL SYSTEM
System Overview
Landing Operation Panel

CBI5.5

- 4 Core wires
- 2*0.22 sq.mm- Green, White
- 2*0.50 sq.mm-White, Black
- Length: 5.5 Mtr
- Both side female connector (4 pin)
- One to one connection

CANbus
Terminator
KBL-DCN-3

- 4 Core wire
- 4*1. Sq.mm
- Yellow, Brown, Black, Grey
- Length: 10 Mtr

One Side Lugging One Side Connector


(Male)
KBL-DCN-2

- 5 Core wire
- 5*1. Sq.mm
- Black, Black, Yellow, Brown, Brown
- Length: 3 Mtr
One side male connector and
Other side open 6 wires

KBL-DCN-T

Door contacts line terminator


KBL-DCN-1

- 5 Core wire
- 5*1. Sq.mm
- Yellow, Yellow, Black, Grey, Brown
- Length: 3.3 Mtr
KBL-DCN-1 internal connection
1
Travelling Cable
- 118
- 119A
- 119B
- 120
- 135
- 140

- ML1
- ML2
- 100
- 1000
- CANL
- CANH

- PE
- K220
-N
-1
- NF
* Please maintain
4 grouping sequence in
travelling cable
- YH1
- YH2
- YH3
- YH4
- YH5
- YH6
- YH7
Pit Cable

- 110 (Emergency pit stop)


- 110A (Emergency pit
stop)
- 117 (Bottom limit switch)
- 118 (Bottom limit switch
- AL (Alarm)
- 100 (Alarm)
- SPARE-1
- SPARE-2
- SPARE-3
- SPARE-4

*Spare cables for Intercom, Fire


switch. Etc
Car Operation Panel (COP) Installation

(* COP cable for CPC & Genemek COP will be


different)
Car Operational Panel Connection (Inside)

BCD-2X

Button Cable (KBL-BT4)

- Length: 150cm
- Two end with female
KBL-BT4
connector
Button Cables

CPC
Genemek Serial COP Installation

(* COP cable for CPC & Genemek COP will be different)

You might also like