CONDITION FOUND: The System tested as per Manual Instruction, found working satisfactory.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
4- Window Wipers:
CONDITION FOUND: The Equipment checked for function and proper working condition found satisfactory.
Cables and wires checked visually all in order. Manufacturer instructions complied.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
5- Magnetic Compass:
CONDITION FOUND: The Compass checked for any Deficiencies and air bubble not found- Nil, Error verified
when weather permit and deviation obtained found matching with deviation card, the Compass in good working
condition. Spare Magnetic Compass also checked.
REPAIRS DONE: NIL.
SPARES USED: NIL.
SURVEY REPORT (if applicable): N/A
6- RADAR 1 & RADAR 2:
CONDITION FOUND: The Equipment checked and tested as per Manual Instruction, Performance checked every
watch, the RADAR found in good and satisfactory working order.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
7- Log Speed:
CONDITION FOUND: The Equipment checked and tested as per Manual Instruction on all mode (AUTO-WT-
BT-GPS) found satisfactory.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
8- Echo Sounder:
CONDITION FOUND: The Equipment checked for recording quality with different Gain and Tested for
recording function at Different ranges, Charted depths compared with sounding
reading found matching and satisfactory. Self-test carried out, unit system checked all in order Manufacturer
instructions complied with.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
9- Course Recorder:
CONDITION FOUND: The Equipment checked for recording quality, the recorder performance checked
every noon and recording compared with the Steering gyro found following the same reading and adjusted when
needed so the equipment in satisfactory operational condition, Buffer Cleared.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
10- NAVTEX:
CONDITION FOUND: The Equipment checked and self testing carried out as the Manual Instruction; all
found satisfactory, NAVTEX printer checked and tested for its function found in
good working order.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
- Check Function/Performance:
CONDITION FOUND: The System checked and function/ alarm tested as per Manual Instruction, all found
satisfactory.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
CONDITION FOUND: The Equipment checked and self testing carried out as the Manual Instruction; all
found satisfactory and in good working order.
good working order.
REPAIRS DONE: None.
SPARES USED: None.
SURVEY REPORT (if applicable): None.
16-ANEMOMETER:
CONDITION FOUND: The equipment checked for free movement of body and Propeller, cables checked for
damage and tighten all connections, clean body and propeller. Checked for corrosion and bearing noise.
Compared with indication on wheelhouse
Gauge all satisfactory.
REPAIRS DONE: NONE.
SPARES USED: NONE.
SURVEY REPORT (if applicable): NONE.
17- DRAFT GUAGES:
CONDITION FOUND: THE SYSTEM CHECKED AND CALIBRATE INSTRUMENTS INCLUDING
MEASURING DEVICES AND
gauges. compare against standard gauges and physical measurements carried out.
all units found satisfactory operation at set parameters.
REPAIRS DONE: NONE.
SPARES USED: NONE.
SURVEY REPORT (if applicable): NONE.
20- ECDIS:
CONDITION FOUND: System and function checked. operation verified satisfactory all ecdis alarm tested found
satisfactory
REPAIRS DONE: NONE
SPARES USED: NONE
SURVEY REPORT (if applicable): NONE
22- BNWAS:
CONDITION FOUND:CARRIED OUT A RISK ASSESSMENT BWMS INSPECTED TESTED FOR PROPER
FUNCTION-OK
REPAIRS DONE:NIL
SPARES USED:NIL
SURVEY REPORT (if applicable):N/A
25- LRAHS:
Condition found: Carried out a risk assessment. Refer to drawings/procedures from makers manual. Tested
functioning lrahs as per makers recommended procedure, port & stbd side can't be moved from and pan fail error
is appearing for the stbd, fault report sent to office we will receive portable acoustic unit.
Repairs done:nil
Spares used:nil
Survey report (if applicable):N/A
Please Note: To fill REPAIRS DONE, SPARES USED & SURVEY REPORT (if applicable).
22- CCTV
CONDITION FOUND: Cameras checked Visually all cables and wires in good condition, General up keep done,
water refilled in the system, and all cameras operational. Manual for the system consulted.
REPAIRS DONE: None
SPARES USED: None
SURVEY REPORT (if applicable): N/A
23 Steering gear
Check all found in Good working Order
FLEET BROADBRAND-INMARSAT
CONDITION FOUND: The system and equipment checked for proper functioning, operation. alarms tested and
all associated controls and indications checked and tested for functioning as per manuals instructions all found
satisfactory.
REPAIRS DONE: NONE.
SPARES USED: NONE
SURVEY REPORT (if applicable): NONE.