15 Checking of Thermal Relay Setting

4.15 Checking of Thermal Relay Setting


4.15.1 PSU-007
In the FAR-2137S and 2837S, power is supplied to the antenna AC motor of the gearbox via
PSU-007. The threshold current of the thermal relay of PSU-007 is set according to the type
of the scanner unit.

SCANNER UNIT

RPU-013 J604 TB1 PSU-007


+12V

Relay
RU-xxxx See page 1-14.
Motor ON

K2 Thermar
relay
K1 3 OUT

3 IN
Ship’s Main Fig. 4.15.1 AC Motor Power System Diagram

Thermal relay: Current adjustment position

Back of PSU-007:
Check-marked on relevant unit

Fig. 4.15.2 PSU-007

Table 4.15.1 Setting of Thermal Relay of PSU-007

Crurent
Applicable Type of thermal
Model name of PSU-007 AC motor power set
gearbox relay
value
PSU-007-70-23-S RSB-098 200 (50 Hz)/220 V (60 Hz) 3 2.3 TR-ONH/3 1.7 A
PSU-007-80-10-S RSB-099 380 (50 Hz)/440 V (60 Hz) 3 1.0 TR-ONH/3 0.8 A
PSU-007-72-28-50/60-S RSB-100 220 V (50 Hz) 3 2.8 TR-ONH/3 2.2 A
PSU-007-72-28-50/60-S RSB-101 220 V (60 Hz) 3 2.8 TR-ONH/3 2.2 A
PSU-007-82-12-60-S RSB-102 440 V (60 Hz) 3 1.2 TR-ONH/3 0.8 A

Note: Figures at the end of the model name of the thermal realy represent the minimum
current.