SMGX DATA COMMUNICATION

Vahle Systems
SMGX Data Communication
OVERVIEW – Facts & Figures

✓ SMGX – Slotted Microwave System Xtreme for outdoor use (SMGM only indoor)

✓ Frequency band 5GHz

✓ Ethernet Interface

✓ Profinet / Profisafe (PROFIsafe SIL 3) cycle time 3 - 8 ms

✓ up to 300MBit/s (net 264 MBit/s downlink per SMGX rail)

✓ Simultaneously video and data transmission with one transceiver

✓ coexistent with other radio systems

✓ easy assembly (similar to SMGT system)

✓ up to 400m (max. 3 mobile devices)

✓ Koppler driving in/out of the rail without influence to the remaining devices
SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 2
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
Video and control data transmission

Safety PLC
+ I/Os

Stationary
Fibre optical
switch Substatio
manageable n

SMG cabinet
Remote Control
SMG

Safety PLC
+ I/Os

Mobile
SMG cabinet

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 3
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
PLC Video Data Transmission
stationary control room

PLC

FO SM
VOIP

RTG-1

SMGX

RTG 1
switch

PLC K1

FO MM
VOIP K2

M K3

K4

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 4
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
Slots – 1 Client

base station
max bandwidth : 300Mbps Transmission Ratio from 50%/50% to 12% / 88% or 88% / 12%
Ethernet with 0.5% stepwidth

Download
In this examble below: Download 50% from 260 = 130 mbps

Upload
Uplload 50% from 260 = 130 mbps
260 Mbit/s

Ethernet
130 Mbit/s

130 Mbit/s
Download

mobile unit
Upload

max bandwidth : 260Mbps


260 Mbit/s
SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 5
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
Slots – 2 Clients

Ethernet

Download

Upload
300 Mbit/s

Ethernet Ethernet

132 Mbit/s
132 Mbits

18 Mbit/s
18 Mbit/s

Download
Download

Upload

Upload
150 Mbit/s 150 Mbit/s
SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 6
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
Slots – 3 Clients

Ethernet

Download

Upload
300 Mbit/s

Ethernet Ethernet Ethernet

88 Mbit/s

88 Mbit/s
88 Mbit/s

12 Mbit/s
12 Mbit/s
Download
12 Mbit/s

Upload
Download

Download
Upload

Upload
100 Mbit/s 100 Mbit/s 100 Mbit/s
SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 7
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
OVERVIEW – Latency time

Data communication path from camera to monitor

IP-camera SMGX-System Video-PC+monitor

IP-camera latency SMGX-System latency Video-PC+monitor latency

Latency IP-camera + SMGX-system + Video PC + Monitor = 265 ms

Latency IP-camera e.g. Axis + Video-PC + Monitor = 260ms

Latency SMGX-system = 5ms

✓ SMGX Latency for video data = 5ms


✓ Average Latency for video camera = 260ms e.g. Axis
✓ Average Latency for SMGX + Camera = 265ms
✓ PLC data Latency = 3-8 ms (Cycle time SMGX Transceiver)

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 8
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
OVERVIEW – mechanical components

Termination
Stationary coupler

Entry funnel Profile connector and


potential equalization

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 9
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
Components

Hanger
Profile
Entry / exit funnel Connector
Mobile coupler

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 10
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
bandwidth management

base station mobile unit


max bandwidth : 300Mbps max bandwidth : 260Mbps

✓ All RTG’s which are using the same SMG-rail are sharing the total bandwidth of 300 Mbps .

✓ The bandwidth of the mobile units are not statically and will optimize automatically depending on
the amount of RTG’s and the required data communication.

✓ The min. required bandwidth of each mobile unit gets allocated/reserved. This value must get set in
advance, depending on the total amount of RTG’s.

✓ The ratio of transmission between upload and download is adjustable from 12%/88% to 88%/12%.

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 11
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
What is new ?

system comparison for EMC

WIFI RCOAX SMGX


interference liability (in very high high no
combination with other
RF signals)
availability very low low very high
permited for EMC no decreasing yes
(by end customer) acceptability
costs TCO* high; frequency TCO* high; frequency TCO* low; frequency
management necessary management necessary management not
necessary

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 12
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
Black Channel Communication

Standard Standard
PROFINET PROFINET
protocol protocol

• ProfiSafe is working independently from the host protocol (Ethernet, ProfiNet)


• The data package will have some internal checksums and safety features to ensure safe
operation in automated applications
SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 13
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
Drive-In

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE.
Page 14
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
SMGX Data Communication
New 80MHz Transceiver

New Vahle SMGX Transceiver

SI Segment Interface DI Device Interface

• net data 300 MBit/s per SMGX rail

• Low latency average 6ms

• Times slot data transmission for real-time application

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE. Seite 15
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
Bandwidth benchmark 2018
Test setup

SMGX Data Communication rail


➢ Engineered for 800 Mhz frequency usuage
➢ Center feeding point

SMGX new transcievers


➢ Frequencie upgrade from 40Mhz to 80Mhz
extension

➢ Expectation: Doubling of frequency usuage will


enhance the reliable bandwidth

➢ Result per SMGX rail: Downstream 264 Mbps


Upstream 36 Mbps

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE. Seite 16
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
Bandwidth enhancement 2018
Conclusion

The new data communication features will support:

- Remote Operated RTG cranes ( 3 RTG Cranes per block with 100 Mbit net rate per crane feasible)

- Automated Stacking cranes with integrated Video Monitoring System

- In combination with unipole conductor rail automation of trolley movement on STS cranes

Main features:

- 300 Mbps net rate (264 Up and 36 down)


- Ethernet based protocolls (Profinet / Profinet Safe)
- Low cycle time
- Plug and Play installation
- Easy setup and mainteanance

SMGX – Data Communication The content of this slides is proprietary and confidential information of VAHLE. Seite 17
Vahle Systems and Project Business It is not intended to be distributed to any third party without the written consent of VAHLE.
Future features

Possibilities to increase the bandwidth:

- Use two different frequency in one smgx system to double the bandwidth to 600Mbps
(this will be tested)
- Second smgx to use MIMO with one transceiver to double the bandwidth to 600Mbps