Breakdown voltage tester TOR-80

Fully automated measurement of breakdown voltage up


to 80 kilovolts with the highest possible accuracy.

 Instantaneous (4 μs) disconnection of the test voltage


when a breakdown occurs.

 A variety of standard and custom measurement


procedures can be programmed.

 Simple and convenient user interface.

 Possibility of automatic saving of measurement results on a


computer.

 Availability and flexibility of settings of technical and


metrological parameters using special software.
Comparison of the main characteristics of
TOR by GlobeCore with the best world
brands.
Parameter TОR-80 Other Brands

Maximum output voltage 80 kV. 80 kV.


U out.
Error U out. ± 1% ± 1%
Slew rate U out. 0,1 – 5 kV/s 0,1 – 5 ; 0,5 – 10 kV/s
Display Resolution U out. 0,1 kV 0,1 kV
Disconnection time U out. 4 µs 5 µs
After breakdown
Temperature measuring 0 – 100 ᴼС 0 – 100 ᴼС
range
Temperature resolution 1 ᴼС 1 ᴼС
TOR-80 design

Components: 1-Front panel, 2-Side panels, 3-Printer,


4-keyboard, 5-Display, 6-Top cover, 7-Measure cell, installed under
top cover, 8-USB port, 9-Handles for carrying the installation.
TOR-80 consists of:

1. Display and keyboard module


1. High voltage cell electrodes
2. Printer 2. The body of the electrode with current-carrying parts
3. Electronics Modules 3. The cup of the cell
4. High voltage transformer 4. High voltage supply contacts
5. Conductive parts of supports
5. Measuring cell 6. Adjusting nuts
TIAR - Tan delta and dielectric strength of
liquid dielectrics measurement device
For a tan delta measurement, the main technical
characteristics are: measurement range ;
resolution when measuring the tan delta value
and dielectric conductivity.

In terms of regulation range and accuracy of setting


the amplitude and frequency of the testing
voltage, purity of the harmonic composition of
the signal, TIAR is unmatched with the world
analogues.

This is achieved by digitally setting the sine wave


and using an original high-quality high-voltage
amplifier to supply voltage to the measured
object.

TIAR provides complete automation of the


measurement process.
TIAR working parameters comparison
with other brands
Parameter TIAR Other Brands
Tan delta measurement 4 … 1x 4 … 1x
Resolution 1x 1x
Measurement of relative 1 … 30 1 … 30
dielectric conductivity
Resolution 0,01 0,01
Testing voltage 500 … 2000 V RMS 500 … 2000 V RMS
Testing voltage frequency 45 … 65 Гц 50, 60 Гц
Temperature measurement 10 … 110 ᴼС 10 … 110 ᴼС
range
Temperature measurement 0,1ᴼС 0,1ᴼС
resolution
Weight Up to 6 kg 28 kg
TIAR design

1 - Upper part of the unit body, 2 - Mounting plate, 3 - the cover of the measuring cell, 4 - Cell communication cable, 5 -
Connector for connecting the cell cable, 6 - Measuring cell, 7 - the Fastening clamp, 8 - Niche of the oil drain pan, 9 -
Installation bottom (bottom cover), 10 - Cell drain hole, 11 - Legs, 12 - Electronic modules, 13 - Power cable connection
module, 14 - Handles for lifting the unit, 15 - Electronic control module, 16 - Electronic module of power supply of the
installation, 17 - The lower part of the measuring cell with a drain hole of the oil drain valve, 18 - Electronic module of
measurement, 19 - Reference capacitor, 20 - Electronic module of the high-voltage amplifier.
TOET-1 Transformer Oil Express Test Kit
• Express test kits detect the amount of moisture in
dielectric insulation oils
• The high precision and excellent long-term stability
make this testing device an ideal solution for
continuous monitoring of moisture in transformer oils.
• The test kit is compact, reliable, simple to operate and
multifunctional; it is the best choice for moisture
measurement.
• The device also measures such parameters as water
activity (aw), temperature (t), and calculates absolute
water content in ppm.
• The device combines everything necessary for simple
and comfortable operation: two digital displays to
indicate sample temperature moisture content in ppm, a
detachable sample container and two buttons: power
and measurement.
The test kit combines a wide range of capabilities and
economy. Changing a sample has never been easier:
simply change the detachable sample container and
press the measurement button to start!
TOET-1 Specification
Range 0...1 aw (water activity (aw))
Precision at 20 °C ±0.02 aw (0...0.9 aw) ±0.03 aw (0.9...1 aw)
Temperature measurement Yes
Extra functionality High precision
Sample temperature, °С -40...80
Ambient temperature, °С -40...60

The content of water in oil can be described as absolute (ppm) or relative (aw).
- ppm is the ratio of moisture weight to oil weight;
-aw is the actual content of water expressed as a share of completely water-saturated oil.

An aw value of 0 corresponds to completely dehydrated oil, whereas aw=1 corresponds to


completely saturated oil.
TOET-2 Hydrogen/Moisture Express
Tester
The dissolved hydrogen and moisture
monitor provides critical and timely
information necessary to keep the
entire transformer fleet operating
reliably and safely. The TOET-2
transformer oil express tester
performs a high-precision test of
the hydrogen and moisture content
both in mineral oils and in various
ester-based oils.
Parameter Value
Range, ppm 25-5000
Precision 20% of indication or 25 ppm
Repeatability 10% of indication or 15 ppm
Response time <60 minutes (90% of step change)
Less than 2% cross-sensitivity to other gases (CO,
Cross-sensitivity
CO2, hydrocarbons)
Sample temperature, °С 0...55
Required power, W 60
Single phase 50Hz AC power supply voltage, V 220
Dimensions, mm
- length 235
- width 265
- height 350
Weight, kg 10
1 – housing;

TOET-2 DESIGN: 2 – back panel;


3 – oil intake container;
4, 5 – ball valves;
6 – oil inlet/outlet fitting for oil
humidity sample container;
7 – LCD panels;
8 – relief valve;
9 – tester on/off button;
10 – vacuum pump on/off
button;
11 – vacuum pump;
12 – hydrogen sensor;
13 – moisture sensor;
14 – printer;
15 – oil pan;
16 – 220 V power cable;
17 – oil sump
TOSC-Transformer Oil Stream Controller
TOSC purpose
1) Constant monitoring of:
moisture level , oil
temperature, dissolved
hydrogen level.
2) Evaluation of the parameters
of Transformer Oil quality and
its conditions
3) Online oil treatment
4) Visualization of oil
parameters and transformer
conditions through the web-
interface
TOSC-Transformer Oil Stream Controller consists of:

Monitoring and data collection section for monitoring the oil


condition and informing about the need for its processing.

Oil treatment section for removing moisture from transformer


oil.

TSS (Transformer Security System) unit for connecting to the


transformer oil tank and protecting the transformer: removing
air from pipelines and monitoring the oil level in the
transformer during processing while transformer is energized.
TOSC - Continuous transformer oil
monitoring system:
TOSC interface:

You might also like