The specified design pressure exceeds 2.5 psi. API-650 limits the maximum design pressure to 2.5 psi.
ERROR #152 (General Tank Data)
Since insulation thickness has been specified, the corresponding insulation density must be greater than 0.0.
WARNING #169 (General Tank Data)
API-650 Paragraph 5.5.3 warns that for tanks in excess of 75 ft in height, an elastic analysis must be used to determine the annular plate thickness.
WARNING #179 (Roof Data)
The net area at the roof shell junction has been reset to the minimum required by 5.1.5.9 for Metric units.
FATAL ERROR #83 (Roof Data)
The allowable stress for the roof plates must be a value greater than zero.
FATAL ERROR #84 (Roof Data)
The allowable stress for the structural members must be a value greater than zero.
FATAL ERROR #98 (Roof Data)
The yield strength of the structural members or the roof plates has not been specified. This occurs when updating earlier data files or not selecting the material from the database. On the roof data spreadsheet, reselect the material for the structural members from the data base. This will correctly acquire/save the yield strength.
FATAL ERROR #173 (Roof Data)
The tensile strength of the structural members or the roof plates has not been specified. This occurs when updating earlier data files or not selecting the material from the database. On the roof data spreadsheet, reselect the material for the structural members from the data base. This will correctly acquire/save the tensile strength.
FATAL ERROR #98 (Roof Data)
The yield strength of the structural members or the roof plates has not been specified. This occurs when updating earlier data files or TANKTM 2017 TANK 2017 SP1, API-650/653/620/579 Analysis Page 3 of 3 Licensee: SPLM Licensee Job: Untitled2 Date: Dec 27,2023 Time: 3:45pm
not selecting the material from the database. On the
roof data spreadsheet, reselect the material for the structural members from the data base. This will correctly acquire/save the yield strength.
FATAL ERROR #173 (Roof Data)
The tensile strength of the structural members or the roof plates has not been specified. This occurs when updating earlier data files or not selecting the material from the database. On the roof data spreadsheet, reselect the material for the structural members from the data base. This will correctly acquire/save the tensile strength.
WARNING #91 (Roof Data)
The specified value for the LIVE load on the roof is not sufficient to satisfy the requirements of API-650 5.2.1.f. This section requires a load of at least 20 lb/sq ft (0.13888 psi).
Error Check Summary Report
Fatal Errors 8
Warning Messages 3
Notes 0
Error Checking Completed
ERRORS ENCOUNTERED - ANALYSIS PROHIBITED
TANK(R) Intergraph CADWorx & Analysis Solutions, Inc. 2017