Untitled2 Out

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

TANKTM 2017

TANKTM 2017

Table of Contents

Job Title Page 1


Error Checker .LOG File 2
TANKTM 2017
TANK 2017 SP1, API-650/653/620/579 Analysis Page 1 of 3
Licensee: SPLM Licensee
Job: Untitled2 Date: Dec 27,2023 Time: 3:45pm
TANKTM 2017
TANK 2017 SP1, API-650/653/620/579 Analysis Page 2 of 3
Licensee: SPLM Licensee
Job: Untitled2 Date: Dec 27,2023 Time: 3:45pm

C:\Users\RIAL.ADAM\Documents\Untitled2.tkdb 12/27/23 15:45:44

FATAL ERROR #15 (General Tank Data)


The specified design pressure exceeds 2.5 psi.
API-650 limits the maximum design pressure to
2.5 psi.

ERROR #152 (General Tank Data)


Since insulation thickness has been specified, the corresponding
insulation density must be greater than 0.0.

WARNING #169 (General Tank Data)


API-650 Paragraph 5.5.3 warns that for tanks
in excess of 75 ft in height, an elastic analysis
must be used to determine the annular plate thickness.

WARNING #179 (Roof Data)


The net area at the roof shell junction has been reset to the
minimum required by 5.1.5.9 for Metric units.

FATAL ERROR #83 (Roof Data)


The allowable stress for the roof plates must be a
value greater than zero.

FATAL ERROR #84 (Roof Data)


The allowable stress for the structural members must be a
value greater than zero.

FATAL ERROR #98 (Roof Data)


The yield strength of the structural members
or the roof plates has not been specified.
This occurs when updating earlier data files or
not selecting the material from the database. On the
roof data spreadsheet, reselect the material for the
structural members from the data base.
This will correctly acquire/save the yield strength.

FATAL ERROR #173 (Roof Data)


The tensile strength of the structural members
or the roof plates has not been specified.
This occurs when updating earlier data files or
not selecting the material from the database. On the
roof data spreadsheet, reselect the material for the
structural members from the data base.
This will correctly acquire/save the tensile strength.

FATAL ERROR #98 (Roof Data)


The yield strength of the structural members
or the roof plates has not been specified.
This occurs when updating earlier data files or
TANKTM 2017
TANK 2017 SP1, API-650/653/620/579 Analysis Page 3 of 3
Licensee: SPLM Licensee
Job: Untitled2 Date: Dec 27,2023 Time: 3:45pm

not selecting the material from the database. On the


roof data spreadsheet, reselect the material for the
structural members from the data base.
This will correctly acquire/save the yield strength.

FATAL ERROR #173 (Roof Data)


The tensile strength of the structural members
or the roof plates has not been specified.
This occurs when updating earlier data files or
not selecting the material from the database. On the
roof data spreadsheet, reselect the material for the
structural members from the data base.
This will correctly acquire/save the tensile strength.

WARNING #91 (Roof Data)


The specified value for the LIVE load on the roof
is not sufficient to satisfy the requirements of
API-650 5.2.1.f. This section requires a load of at
least 20 lb/sq ft (0.13888 psi).

Error Check Summary Report

Fatal Errors 8

Warning Messages 3

Notes 0

Error Checking Completed

ERRORS ENCOUNTERED - ANALYSIS PROHIBITED


TANK(R) Intergraph CADWorx & Analysis Solutions, Inc. 2017