Product Specifications

E15S09P54
Tower Mounted Amplifier, Dual 2600 MHz with AISG
l Industry leading PIM performance

l TMA is operating in AISG & CWA mode, Alarm Current consumption CWA mode 190
mA

General Specifications
Product Type 1-BTS:1-ANT (Uniplex)
Modularity 2-Twin
Includes Mounting hardware

Electrical Specifications
Sub-module 1|2
Branch 1
Port Designation ANT
License Band IMT 2600, LNA

Electrical Specifications Rx (Uplink)


Frequency Range 2500–2570 MHz
Bandwidth 70.00 MHz
Gain, nominal 12.0 dB
Gain Tolerance ±1
Noise Figure, maximum 1.6 dB
Noise Figure, typical 1.5 dB
Group Delay Variation, maximum 20 ns
Group Delay Variation Bandwidth 5.00 MHz
Output IP3, minimum 25 dBm
Return Loss, minimum 18 dB
Insertion Loss - Bypass Mode, typical 2.5 dB
Return Loss - Bypass Mode, typical 16 dB
TX Band Rejection, minimum 45 dB

Electrical Specifications Tx (Downlink)


Frequency Range 2620–2690 MHz
Bandwidth 70.00 MHz
Insertion Loss, maximum 0.50 dB
Insertion Loss, typical 0.30 dB
Insertion Loss Ripple, maximum 0.10 dB
Group Delay Variation, maximum 10 ns

©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. page 1 of 4
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 25, 2017 August 1, 2017
Product Specifications
E15S09P54

Group Delay Variation Bandwidth 5.00 MHz


Return Loss, minimum 18 dB
Input Power, RMS, maximum 160 W
Input Power, PEP, maximum 2500 W
3rd Order PIM, typical -160 dBc
3rd Order PIM Test Method Two +43 dBm carriers

Product Classification
Product Type Tower mounted amplifier

AISG Electrical Specifications


Voltage, AISG Mode 10–30 Vdc
Protocol AISG 2.0
AISG Connector 8-pin DIN Female
AISG Connector Standard IEC 60130-9

dc Power/Alarm Electrical Specifications


Voltage 7–30 Vdc
dc Switching/Redundancy Yes
Operating Current at Voltage 100 mA @ 12 V
Operating Current Tolerance ±15 mA
Alarm Current, CWA Mode 185 mA ±10 mA
Lightning Surge Current 10 kA
Lightning Surge Current Waveform 8/20 waveform

©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. page 2 of 4
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 25, 2017 August 1, 2017
Product Specifications
E15S09P54

Block Diagram

Mechanical Specifications
RF Connector Interface 7-16 DIN Female
RF Connector Interface Body Style Long neck
Ground Screw Diameter 8.00 mm
Color Gray
Finish Painted
Mount Type Pole | Wall
Mounting Pipe Diameter 40–160 mm
Mounting Pipe Hardware Band clamps (2)
Wind Speed, maximum 55 m/s

Dimensions
Height 175.0 mm | 6.9 in
Width 231.0 mm | 9.1 in
Depth 58.5 mm | 2.3 in
Volume 2.3 L
Weight 4.0 kg | 8.8 lb

Environmental Specifications
Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Ingress Protection Test Method IEC 60529:2001, IP67

©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. page 3 of 4
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 25, 2017 August 1, 2017
Product Specifications
E15S09P54

Outline Drawing

©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. page 4 of 4
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 25, 2017 August 1, 2017