Third Angle Projection: Equipment Ordering Specification For Masoneilan Valve, Anti-Surge Model 52-49449-Size 4"

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

SIZE DWG NO SH REV

A 427A7740 1 -
THIRD ANGLE PROJECTION REVISIONS
REV DESCRIPTION DATE APPROVED
- INITIAL RELEASE ECM 500000xxxxxx 2016-06-29 Mohamed Gamil

THIS DOCUMENT SHALL BE REVISED IN


ITS ENTIRETY. ALL SHEETS OF THIS
DOCUMENT ARE THE SAME REVISION
LEVEL AS INDICATED.

THIS DRAWING TO BE REVISED IN


MICROSOFT WORD ONLY. THE SOURCE
FILE IS STORED IN THE MCS DMS

ITEM DESCRIPTION DWG. NO.


LIST OF COMPLEMENTARY DOCUMENTS

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
UNLESS OTHERWISE SPECIFIED SIGNATURES DATE GENERAL ELECTRIC COMPANY
DIMENSIONS ARE IN INCHES DRAWN CONTROL SOLUTIONS
2016-06-20
TOLERANCES ON: Mohamed Gamil
2 PL DECIMALS + CHECKED
M 2016-07-04 GE MEASUREMENT & CONTROL
Equipment Ordering Specification for
3 PL DECIMALS + ENGINEER
Mohamed Gamil 2016-06-20

ANGLES + ISSUED
Masoneilan Valve, Anti-Surge
201y-mm-dd
Model 52-49449- Size 4”.
FRACTIONS + FIRST MADE FOR: 1LO-150099999

APPLIED PRACTICES SIZE CAGE CODE DWG NO

A 427A7740
NONE

ET: 94 SIMILAR TO: NONE SCALE: NONE SHEET 1 of 12


SIZE DWG NO SH REV
A 427A7740 2 -

Equipment Ordering Specification

1.0 Purpose
This document was made to provide a written design specification for Masoneilan Valve , model 52-
49449-4.
2.0 Description

The 52-49449-4 Masoneilan Valve should be supplied with a will a restrictor plate. The two, the valve
and plate will be used as an anti-surge valve, that will recycle the compressed gas from the
compressor discharge line back to the suction line to avoid compressor damage. The valve should be
designed with a repose time of < 2.0 sec to fully open, on a command of 4-20mA.
Refer to Table 1 and Table 2 for more details
3.0 Ordering Information & Instructions
DRESSER PRODUITS INDUSTRIELS S.A.S.
3 rue Saint Pierre - BP 87
14110 Condé-sur-Noireau
France
T +33 (0)2 31 59 59 59
F +33 (0)2 31 59 59 60

4.0 Regulatory Requirements


Supplier shall maintain a TCF (Technical Construction File) supporting all regulations required and
shall provide it to GE upon request.
Supplier shall maintain a TCF (Technical Construction File) supporting all regulations required and
shall provide it to GE upon request. The following standards, in their latest revision in effect on the date
of invitation for bids, form a part of this ordering drawing to the extent specified herein
4.1 Applicable Standards
4.1.1 EN 60079-0:2012+A11:2013 Explosive Atmospheres – Part 0: Equipment General
Requirements,
4.1.2 EN 60079-1:2007 – Explosive Atmospheres – Part 1: Equipment Protection by Flameproof
Enclosures “D”
4.1.3 EN 61000-6-2:2005 – Generic Immunity Standards for Industrial Applications. Evaluation
has been determined that this design in inherently immune to electrostatic discharge and
surge voltages
4.1.4 IEC 61326-1 ED32.0 Electrical equipment for measuring, control and laboratory use – EMC
requirement – Pat1: General Requirement
4.1.5 93 /68/EC Marking CE Directive
4.1.6 2006 /95/EC Low Voltage Directive (LVD)
 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 2 of 12
SIZE DWG NO SH REV
A 427A7740 3 -
4.1.7 EN 60529 Mechanical protection ( IP) codes for electrical devices
4.1.8 ASME B31.3 Process Piping, 2012
4.1.9 ANSI/API 574 Inspection Practices for Piping System Components
4.1.10 NACE MR0175-2003 – Sulfide Stress Cracking Resistant Metallic Materials for Oilfield
Equipment
4.1.11 ANSI / FCI 70.2 and IEC 534-4 Class IV for Standard Seat Leakage
4.1.12 ASME B31.3 Process Piping, 2012
4.1.13 IEC 61326-1 ED32.0 Electrical equipment for measuring, control and laboratory use – EMC
requirement – Pat1: General Requirement

4.2 Deliverables (Documents)


Electronic Submittals should be e-mailed to the buyer listed on the purchase order
Hard copy should be sent and packaged with the ordered material
Electronic should be e-mailed to the buyer listed on the purchase order. Hard copy should be sent
and packaged with the ordered material
4.2.1.1 Functional Test Certificate
4.2.1.2 Part List and Instruction Manual
4.2.1.3 Dimensional Drawings
4.2.1.4 CE DOCF (Declaration of Conformity)
4.2.1.5 ATEX Certificate
4.2.1.6 NACE Compliance Certificate
4.2.1.7 Complete Data sheets filled will all design and data for valve and accessories
4.2.1.8 Wiring Diagram
4.2.1.9 Hookup Drawings

5.0 Applicable Documents


5.1 Request for copies
Requests for copies of GE Company Specifications and Standards should be addressed to the
Buyer, at the Sourcing Department address shown on the purchase order or letter of inquiry.
Other documents should be obtained directly from the issuing body.

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 3 of 12
SIZE DWG NO SH REV
A 427A7740 4 -
6.0 Requirements
6.1 Design
6.1.1 See Table 1, Table 2 and Table 3.
6.2 System Requirements
6.2.1 See Table 1, Table 2 and Table 3.
6.3 Performance
6.3.1 See Table 1, Table 2 and Table 3.
6.4 Physical Requirements
6.4.1 Dimensions
The Supplier shall provide the an outline drawing showing the dimensions and the
connection locations
6.4.2 Weight
The Supplier shall provide the assembly weight for each part
6.4.3 Applied Finish
All parts’ surfaces should be free of rust and corrosion. Masoneilan Standard Painting
6.4.4 Cleanliness and workmanship
All parts, components and assemblies shall be thoroughly cleaned prior to and after
assembly and test, including removal of all loose, spattered, or excess soldering or
welding materials, rosin or weld flash, metal chips or other foreign matter, burrs and
sharp edges. All fuel handling components shall be flushed with preserving oil to
prevent rusting during shipment and storage. All openings are to be securely covered
against entry of foreign material after cleaning.
6.4.5 Nameplates and Products marking
Identification markings must be legible after service. Permanent markings shall not be
applied to any critical surface. Nameplates shall be stainless steel or aluminum and
must be securely affixed to survive handling during shipping and installation, as well as
vibration due to valve service.
The Supplier marking shall include at a minimum the following above the legal
requirements:
 GE Part Number
 GE Device Tag Name per Table 4
 Product Name and Nomenclature
 Serial Number
 Supplier Name or Supplier Code

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 4 of 12
SIZE DWG NO SH REV
A 427A7740 5 -

6.5 Accessories
6.5.1 Air filter regulator, MASONEILAN model 78-40G
6.5.2 E/P Smart Positioner 4-20 ma (Hart), MASONEILAN model SVI2AP-31123121
6.5.3 Booster 1/2". Made MASONEILAN, model BR400
6.5.4 Quick Exhaust Valve, ACS/MIDLAND, model 8QEVSN122 – Connection 1”NPT
6.5.5 Needle valve, Made SAMI, Model 9082- Connection ½”NPT
6.5.6 Position transmitter + Limit switch II2G EExdIICT6 (4-20mA output + 2 micro switch SPDT
Type) - ISO M20 1.
Make MASONEILAN, model 496.857/2 (Honeywell BZRA2)
Hazardous Area : ATEX Zone 1 II B T3 – EEXd flame proof protection

7.0 Quality Assurance Provisions


7.1 Test methods and procedures
7.1.1 Refer to Table 1. Inspection and Test Plan.
The supplier shall perform the tests described in this paragraph for each
manufactured unit prior to shipment. Satisfactory completion of these tests is a
requirement before shipment is made for each manufactured unit. The supplier shall
be required to submit in writing production inspection and test data, as specified by
this specification, the purchase order, ordering sheet or quotation request.
To support requirements stated in Section 3, including criteria for success (Tollgate
process defined):
7.2 Production Valve Leakage Tests
The following valve leakage testing is required to be performed by the Supplier for the
acceptance on each manufactured unit prior to shipment:
 Valve Seat Leakage Performance and Testing
 External Valve Leakage and Testing
7.3 Production Valve Hydrostatic Test
All valve designs shall be tested to conform to the ANSI/PED hydrostatic testing standard
7.4 Production Actuator Tests
The following valve actuator tests and requirements shall be demonstrated by the Supplier for
the acceptance of each manufactured unit prior to shipment:
Trip Time on 4-20mA = < 2.0 Sec

8.0 Preparation for Delivery


Reference P23E-AL-0255

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 5 of 12
SIZE DWG NO SH REV
A 427A7740 6 -

Table 1: Inspection and Test Plan

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 6 of 12
SIZE DWG NO SH REV
A 427A7740 7 -

Table2A. Valve Specification Sheet

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 7 of 12
SIZE DWG NO SH REV
A 427A7740 8 -

Table2B. Accessory Sheet

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 8 of 12
SIZE DWG NO SH REV
A 427A7740 9 -

Table2C. Restrictor Sheet

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 9 of 12
SIZE DWG NO SH REV
A 427A7740 10 -

Table 3. Valve Calculation Sheet

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 10 of 12
SIZE DWG NO SH REV
A 427A7740 11 -

Figure 1. Valve Out Line Drawing

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 11 of 12
SIZE DWG NO SH REV
A 427A7740 12 -

Table 4. Ordering Inforamtion

Part Number Tag Name


427A7740P0001 61-FV-01
427A7740P0002 61-FV-02
427A7740P0003 61-FV-03
427A7740P0004 61-FV-04

 COPYRIGHT 2016 GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE MEASUREMENT & CONTROL (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE
EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO
MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE
MEASUREMENT & CONTROL (USA), LLC AND/OR ITS AFFILIATES. PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GE MEASUREMENT & CONTROL (USA), LLC AND/OR ITS
AFFILIATES AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH WRITTEN PERMISSION OF GE MEASUREMENT & CONTROL, CONTROL SOLUTIONS
GE CLASS II ( INTERNAL NON CRITICAL )
GENERAL ELECTRIC COMPANY SIZE CAGE DWG NO
CODE
GE MEASUREMENT & CONTROL CONTROL SOLUTIONS
A NONE 427A7740
DRAWN
ISSUED 201y-mm-dd SCALE: NONE SHEET 12 of 12

You might also like