ATLANNA

Reg. Owner: STAR MATRIX OFFSHORE LIMITED


BV Reg. Nr: 05003Q
IMO Number: 9320934
Vessel Type: Supply vessel
Gross Tonnage: 2310
Date of build: 24 Oct 2005
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Table of Contents

Ship Particulars
Owner / Manager Information
Cargo & Ballast Capacities
Conditions of Class / Statutory, ISM, ISPS, MLC Status
Planned Inspection Items
1-Year Survey Planner

The latest published Rules of the Bureau Veritas Marine & Offshore and the Terms of use are applicable
La dernière édition des règlements de Bureau Veritas Marine & Offshore ainsi que les Conditions Générales d'utilisation sont applicables

Any person not a party to the contract pursuant to which this document is Toute personne qui n'est pas partie au contrat aux termes duquel ce document
delivered may not assert a claim against Bureau Veritas for any liability arising est délivré ne pourra engager la responsabilité du Bureau Veritas pour les
out of errors or omissions which may be contained in said document, or for inexactitudes ou omissions qui pourrait y être relevées ainsi que les erreurs
errors of judgement, fault or negligence committed by personnel of the Society de jugement, fautes ou négligences commises par le personnel de la Société
or of its Agents in the establishment or issuance of this document, and in ou par ses agents dans l'établissement de ce document et dans l'exécution
connections with any activities for which it may provide. des interventions qu'il comporte.
Extract of Rules Pt A, Ch 2, Sec 2, [3.4] Extrait du Règlement Pt A, Ch 2, Sec 2, [3.4]
3.4.1 - Information given in the Certificate of Classification, associated 3.4.1 - Les informations données dans le Certificat de Classification, les
endorsements, Rules and specific documents enables the Owner to identify endossements associés, le Règlement et les documents spécifiques au navire
the status of surveys and Conditions of Class/recommendations. permettent à l'Armateur d'identifier la situation des visites et des réserves.
3.4.2 - The omission of such information does not absolve the Owner from 3.4.2 - L'omission de ces informations ne décharge pas l'Armateur de s'assurer
ensuring that surveys are held by the limit dates and pending Conditions of que les visites sont effectuées aux dates limites et que les réserves en suspens
Class/recommendations are cleared to avoid any inconvenience which is liable sont levées, afin d'éviter les inconvénients pouvant résulter de la suspension
to result from the suspension or withdrawal of class; see Ch 2, Sec 3. ou du retrait de la classe; voir Ch 2, Sec 3.
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Ship Particulars
Identification
Ship Type: Supply vessel Flag: Vanuatu
System Ship Type: Other cargo ship Port of Registry: PORT VILLA
IMO Number: 9320934 Call Sign: YJXP6

Classification
Class Symbols: I Hull Mach
Service Notations: Tug Supply vessel Fire fighting ship 1 -water spraying
Navigation Not.: Unrestricted navigation
Add. Class Not.: AUT-UMS, DYNAPOS -AM/AT -R
Machinery: MACH
Equipment: 1 Main anchor, chain diameter 40 mm, steel quality Q3 (Very high tensile strength steel)

Hull
Gross Tonnage 69: 2310 Builder: KEPPEL SINGMARINE PTE LTD
Net Tonnage 69: 693 Country of build: SINGAPORE
Overall Length: 67.39 m Date of build: 24 Oct 2005
LPP: 60 m Hull Material: Steel
Breadth: 15.4 m Hull Info: Machinery Aft
Depth: 7m 1 continuous deck(s)
Draught: 5.99 m Survey Type: Normal (Hull)
Freeboard: 1015 mm

Machinery
Propelling type: Diesel Elec. installation: 2 Generators
Total power: 8210 kW (11154 HP) 2000 kVA (1600 kW), 440 V, 60 Hz
Propelling machinery: 2 CATERPILLAR 3612 DITA 2 Generators
4T, 12 cyl, 1000 rpm 500 kVA (400 kW), 440 V, 60 Hz
Builder: CATERPILLAR Inc. 1 Emergency generator
Date of build: 01 Jan 2004 100 kVA (80 kW), 440 V, 60 Hz
Propeller: 2 Controllable pitch Screw Propeller Survey Type: Normal
LB10, 173 rpm
Auxiliary Engine(s): 2 Diesel (800Kw/1088HP)
Emergency Engine(s): 1 Diesel (80Kw/109HP)

Automated Installations
1. General
The automation installation allows operation of the machinery installation when ship underway, during maneouvvring, in port
and at anchorage

2. Control Stations
Monitoring and control station in the wheelhouse
Without watchkeeper for machinery monitoring

3. Bridge Propulsion Control


Speed control and emergency stopping of main engines
Clutching and disclutching
Controllable pitch propeller - pitch control

4. Automatic Control & Monitoring of Servitude Auxiliaries


Lubricating oil standby pumps
Jacket fresh water cooling standby pumps
Sea water cooling standby pumps

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 1 / 2
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Automated Installations
After cooler fresh water standby pumps

5. Automatic Control & Monitoring of Complementary Auxiliaries


Fuel oil centrifugal purifier
Lub oil centriugal purifier
Starting air compressors

6. Electrical Power Plant


Two diesel engine driven generators with automatic starting, synchoronizing, loading sharing and sheeding
Two main engine drive shaft generators

Dynamic positioning installation


1. Power System comprising of :
- Main Engines (Port &Stbd) and Shaft Alternators (Port & Stbd)
- Auxiliary Engines & Generators 1 and 2 (as standby)
- Main Switchboard, Emergency Switchboard & 230V Switchboard
- 24V Distribution Boards
- Other associated machinery system for Main Engines and Auxiliary Engines

2. Thruster System comprising of :


- Port & Stbd Controlled Pitch Propellers, Port & Stbd Rudders
- Bow Thrusters 1 & 2 and Stern Thruster 1

3. DP Control System (SD-11 & SJS-01) comprising of :


- Computer Consoles - Simrad Dynamic Position System
- Instrumentation Boxes - Dedicated UPS
- DGPS & Fanbeam Position Verification System - Position Reference Systems

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 2 / 2
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Owner / Manager Information


Registered Owner
Name: STAR MATRIX OFFSHORE LIMITED
Company Number: 20/F CHAMPION BUILDING, 287 - 291,
Address: DES VOUEX ROAD, CENTRAL SHEUNG WAN
HONG KONG

XXX

Manager
Name: HERMES MARITIME SERVICES PVT.LTD.
Company Number: 5447301
IMO Number: 10th Floor, Great Eastern Summit - B Wing,
Address: 1001/1002, Sector 15, CBD Belapur,
NAVI MUMBAI 400614
INDIA

Manager ISM
Name: HERMES MARITIME SERVICES PVT.LTD.
Company Number: 5447301
IMO Number: 10th Floor, Great Eastern Summit - B Wing,
Address: 1001/1002, Sector 15, CBD Belapur,
NAVI MUMBAI 400614
INDIA

Manager ISPS
Name: HERMES MARITIME SERVICES PVT.LTD.
Company Number: 5447301
IMO Number: 10th Floor, Great Eastern Summit - B Wing,
Address: 1001/1002, Sector 15, CBD Belapur,
NAVI MUMBAI 400614
INDIA

Manager MLC
Name: HERMES MARITIME SERVICES PVT.LTD.
Company Number: 5447301
IMO Number: 10th Floor, Great Eastern Summit - B Wing,
Address: 1001/1002, Sector 15, CBD Belapur,
NAVI MUMBAI 400614
INDIA

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 1 / 1
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Cargo & Ballast Capacities


Ballast Tanks
Tank/Hold Identification Initial Final Position Last survey Job Number Protection Coating Annual
Frame Frame Cond. Exam.
Fore Peak DW & WB Tank (C) 93 100 Centre 02 Mar 2024 ABJ0/2023/J5122 Hard coated & Good No
Anodes
Aft WB Tank (C) -8 -2 Centre 02 Mar 2024 ABJ0/2023/J5122 Hard coated & Good No
Anodes
Aft Peak DW & WB Tank (S) -8 3 Starboard wing 02 Mar 2024 ABJ0/2023/J5122 Hard coated & Good No
Anodes
Aft Peak DW & WB Tank (P) -8 3 Portside wing 02 Mar 2024 ABJ0/2023/J5122 Hard coated & Good No
Anodes

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 1 / 1
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Conditions of Class /
Statutory, ISM, ISPS, MLC Status
The Conditions of Class / Statutory, ISM, ISPS, MLC Status below shows the information available in VeriSTAR Info database
at the time the report is printed. This may not indicate certificates issued, surveys carried out or conditions of class /
recommendations issued but not yet reported to BV Head Office.

Classification
Status: Active

Certificates
Certificate name Issued Expiry Extended Type Status
Classification
Class Certificate 02 Mar 2024 01 Mar 2029 Definitive
Load line
Load Line Certificate 02 Mar 2024 01 Mar 2029 Definitive
SOLAS
Safety Construction Certificate 02 Mar 2024 01 Mar 2029 Definitive
Safety Equipment Certificate 02 Mar 2024 01 Mar 2029 Definitive
Safety Radio Certificate 02 Mar 2024 01 Mar 2029 Definitive
Dangerous goods DoC 02 Mar 2024 01 Mar 2029 Definitive
MARPOL
Oil Pollution Prevention Certif 02 Mar 2024 01 Mar 2029 Definitive
Sewage Pollution Prevention Certif 02 Mar 2024 01 Mar 2029 Definitive
Air Pollution Prevention Certif 02 Mar 2024 01 Jun 2024 Conditional
IEE Certificate 02 Mar 2024 Definitive
BWM convention
Ballast Water Management Certif. 02 Mar 2024 01 Aug 2024 Interim
ILO 152
ILO 152 Cargo Gear 02 Mar 2024 Definitive
AFS convention
Anti-Fouling System Certificate 02 Mar 2024 Definitive
ISM Code
Safety Management Certificate 02 Mar 2024 02 Sep 2024 Interim
ISPS Code
Ship Security Certificate 02 Mar 2024 02 Sep 2024 Interim
MLC Code
MLC Certificate 02 Mar 2024 02 Sep 2024 Interim

Legend:
Expired Expires in less than 1 month Expires in less than 3 months

Surveys / Audits / Inspections


Classification Surveys
Survey name Last Due Date Range (from, to) Postponed Status

Hull - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2027 - 01 Mar 2029
Hull - Annual for Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Hull - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025

Legend:
Overdue Overdue in less than 1 month Within the range

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 1 / 3
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Surveys / Audits / Inspections


Classification Surveys
Survey name Last Due Date Range (from, to) Postponed Status
Annual survey of structure 01 Mar 2025 01 Dec 2024 - 01 Jun 2025
Hull - Intermediate 01 Sep 2026 01 Dec 2025 - 01 Jun 2027
Bottom Survey in Dry Dock or 02 Mar 2024 02 Mar 2027 02 Mar 2027
afloat

Machinery - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2027 - 01 Mar 2029
Machinery - Annual for Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Machinery - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025
PS Tailshaft - Complete 02 Mar 2024 02 Mar 2034 02 Mar 2034
PS Tailshaft - Modified 02 Mar 2029 02 Sep 2028 - 02 Sep 2029
SB Tailshaft - Complete 02 Mar 2024 02 Mar 2034 02 Mar 2034
SB Tailshaft - Modified 02 Mar 2029 02 Sep 2028 - 02 Sep 2029

Automation - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2027 - 01 Mar 2029
Automation - Annual for Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Automation - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025

DYNAPOS Renewal Survey 02 Mar 2024 01 Mar 2029 01 Dec 2027 - 01 Mar 2029
DYNAPOS Annual Survey 01 Mar 2025 01 Dec 2024 - 01 Jun 2025
DYNAPOS Annual Survey Fro 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Renewal

Statutory Surveys
Survey name Last Due Date Range (from, to) Postponed Status

Load Line - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Load Line - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025

Saf. Construction - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2027 - 01 Mar 2029
Harmonized Safety Construction 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Annual Survey For R
Saf. Construction - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025
Saf. Construction - intermediate 01 Mar 2027 01 Dec 2025 - 01 Jun 2027

Saf. Equipment - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Saf. Equipment - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025
Saf. Equipment - Periodical 01 Mar 2026 01 Dec 2025 - 01 Jun 2026

Saf. Radio - Renewal 01 Mar 2029 01 Dec 2028 - 01 Mar 2029


Saf. Radio - Periodical 01 Mar 2025 01 Dec 2024 - 01 Jun 2025

Dangerous Goods - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Dangerous Goods - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025

Oil Pollution - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029
Oil Pollution - Annual 01 Mar 2025 01 Dec 2024 - 01 Jun 2025
Oil Pollution - Intermediate 01 Mar 2026 01 Dec 2025 - 01 Jun 2026

Sewage Pol - Renewal 02 Mar 2024 01 Mar 2029 01 Dec 2028 - 01 Mar 2029

Air Pollution - Renewal 02 Mar 2024 20 Nov 2025 20 Aug 2025 - 20 Nov 2025

Ballast Water Mngt - Renewal 02 Mar 2024 02 Mar 2029 02 Dec 2028 - 02 Mar 2029
Ballast Water Mngt - Annual 02 Mar 2025 02 Dec 2024 - 02 Jun 2025
Ballast Water Mngt - Intermediate 02 Mar 2026 02 Dec 2025 - 02 Jun 2026

ILO 152 Cargo Gear - Periodical 02 Mar 2024 02 Mar 2029 02 Mar 2029
ILO 152 Cargo Gear - Annual 02 Mar 2024 02 Mar 2025 02 Mar 2025

Legend:
Overdue Overdue in less than 1 month Within the range

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 2 / 3
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Surveys / Audits / Inspections


Statutory Surveys
Survey name Last Due Date Range (from, to) Postponed Status

Anti-Fouling System - Renewal 02 Mar 2024

Statutory Audits / Inspections


Audit / Inspection name Last Due Date Range (from, to) Postponed Status

ISM - Initial 02 Sep 2024 02 Sep 2024 Limit Date in less than 6 m.
ISM - Interim 02 Mar 2024

ISPS - Initial 02 Sep 2024 02 Sep 2024 Limit Date in less than 6 m.
ISPS - Interim 02 Mar 2024
SSP approved or amended satisfactorily on 29 Jul 2021

MLC Initial inspection 02 Sep 2024 02 Sep 2024 Limit Date in less than 6 m.
MLC Interim 02 Mar 2024
DMLC reviewed satisfactorily on 16 Oct 2020

Legend:
Overdue Overdue in less than 1 month Within the range

Tests done by Service Suppliers


Test name Last recorded
LSA annual test 10/12/2020
LSA renewal test 16/10/2010

Conditions of Class / Statutory Recommendations


None

ISM Code Non-Conformities


None

ISPS Code Non-Conformities


None

MLC Convention Deficiencies


None

Class Memoranda
Issued Description of Memoranda
09 Dec 2005 Ballast tank subject to annual inspection : none
18 Apr 2012 WEAR MARKS ON INNER PORT SIDE TAILSHAFT BUSHING.
23 Apr 2020 DYNAPOS AM AT R notation suspended pending the repair of port side main engine.
02 Mar 2024 Fire fighting ship 1 notation suspended pending the repair of Fi-Fi.

Statutory Memoranda
None

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 3 / 3
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

Planned Inspection Items


Statutory Items
MARPOL Annex VI Prevention Air Pollution Certific.
Item Nr Date Type VS* Inspection Item Due Date Action Date
ABJ0/2023/J5122-AP1O 02 Mar 2024 Obs 1 EIAPP for both main engines and generators to be 01 Jun 2024
provide and placed on board
ABJ0/2023/J5122-AP2O 02 Mar 2024 Obs 1 Fuel oil sample point to be fixed 01 Jun 2024

* Verification Scheme:
1 Inspection/test/report by authorized person and confirmation of action taken through www.veristar.com by the indicated due
date. Documentary evidence to be kept on board. Verification/confirmation by BV Surveyor during next attendance onboard
2 Inspection by BV Surveyor by due date

Legend:
Recommendation overdue Observation overdue
Recommendation overdue in less than 1 month Observation overdue in less than 1 month
Recommendation with limit date in less than 3 months Observation with limit date in less than 3 months
Recommendation with action taken – To be confirmed Observation with action taken – To be confirmed
Conditions of Class overdue
Conditions of Class overdue in less than 1 month
Conditions of Class with limit date in less than 3 months
Conditions of Class with action taken – To be confirmed

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 1 / 1
VeriSTAR Info Survey Status Report
Ship name: ATLANNA BV Nr: 05003Q

1-Year Survey Planner


Class Surveys
Survey name Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar

Hull - Annual
Annual survey of structure
Machinery - Annual
Automation - Annual
DYNAPOS Annual Survey

Statutory Surveys
Survey name Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar

Load Line - Annual


Saf. Construction - Annual
Saf. Equipment - Annual
Saf. Radio - Periodical
Dangerous Goods - Annual
Oil Pollution - Annual
Ballast Water Mngt - Annual
ILO 152 Cargo Gear - Annual

Statutory Audits / Inspections


Audit / Inspection name Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar

ISM - Initial
ISPS - Initial
MLC Initial inspection

Observations
Item desc. Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar

Statutory Observations - MARPOL Annex VI


Prevention Air Pollution Certific.
ABJ0/2023/J5122-AP1O - EIAPP for
both main engines and generators to be
provide and placed on board
ABJ0/2023/J5122-AP2O - Fuel oil
sample point to be fixed

Bureau Veritas Marine & Offshore


Generated on 13 Mar 2024 Page 1 / 1
Bureau Veritas Marine & Offshore
Tour Alto, 4 Place des Saisons, 92400 Courbevoie, France
Tel.: 33 (0) 1 55 24 70 00 / 33 (0) 1 55 24 72 66 - Fax: 33 (0) 1 55 24 70 51
Corporate website: http://www.bureauveritas.com
Marine website: http://www.veristar.com
Email: veristarinfo@bureauveritas.com

You might also like