Professional Documents
Culture Documents
TR 20 - 09 Software Update For Small - Mid Size Filling Machines 3. Gen. - 32 - 35
TR 20 - 09 Software Update For Small - Mid Size Filling Machines 3. Gen. - 32 - 35
Nr.: 20 / 09
CBEU
Version 20.55
A condition for the software update to Version 20.55 is the conversion of the TR 22 / 07
(Mustpoint)
That means,
• Versionupdate V20.05 (V20.11)
• PLC with type 414-2XG05, 414-2XK05 or 412-2XJ05
• Operating panel / PC from Messrs. Beckhoff
Machinentyp
Identifier
CFA … Valid for machine Ordernumber
-32/-35
PLC STEU + 8605.51 045 + 8605.51 048
510
PLC TEMP 8601.98 780
810 8608.51 002 - 8608.51 008
+ 1 Servoaxis US
8693.51 001 - 8693.51 013
312 PLC STEU + 8603.51 054 + 8603.51 062 + 8603.51 065
512 PLC TEMP 8695.51 001 - 8695.51 008 8601.98 781
812 + 5 Servoaxis 8605.51 054 + 8605.51 055
8698.51 001 - 8698.51 002
112 PLC STEU + 8701.51 001 8701.51 132
8601.98 782
712 PLC TEMP 8707.51 001 8707.51 125
112 > 8701.51 133
only PLC STEU 8601.98 783
712 > 8707.51 126
8603.51 016 - 8603.51 076
Except maschine:
310 8603.51 054, 8603.51 062, 8603.51 065
510 PLC STEU + 8605.51 029 - 8605.51 053 8601.98 784
612 PLC TEMP Except maschine:
810 8605.51 045 + 8605.51 048
8606.51 006 - 8606.51 017
8608.51 001
312 > 8693.51 014
only PLC STEU
512 > 8695.51 009 8601.98 785
+ 5 Servoaxis
812 > 8698.51 003
Mustpoints: none
Releasepoints:
• Controlling of H2O2-heaters
without internal temperature sensors ..................................(Releasepoint 472)
It is possible to operate the H2O2 evaporators without internal temperature sensors.
Requirement is a build-in conversion kit: Æ 8601.98 443
08 H2O2-Heater
without winding se
31 Failure of air
conditioning unit b
26 Stop
production.doc
30
Handshake.doc
34
CIP-Flashlamp.doc
21 Hour meter
and meter box as
19 PC222
Branson Profibus.d
32 Lubrication
failure locked the
35 Servo valves
control is interrupt
20 Ejector curve
format change.doc
42 Start-hand
wheel.doc
14 Update of the
project SIG_CBTE_
• Elimination of errormessage:
"Servos: r.p.e. servos not synchronous to r.p.e. main……..(Releasepoint 458)
This error was installed for testing and is eliminated now.
TB 2708
Multiple-Disc Clutc
09
Diagnosecounter.d
08 H2O2-Heater
without winding se
Machinentyp
CFA … Identifier Valid for machine Ordernumber
-32/-35
PLC STEU + 860551045 + 860551048 Direction
510
PLC TEMP drive-side
810 860851002 - 860851008
+ 1 Servaxis US 8605.35 050
869351001 - 869351013
869851001 - 869851002
112 PLC STEU + 870151001 870151132
Not available
712 PLC TEMP 870751001 870751125
Direction
> 870151133
drive-side
112 8701.35.404
Only PLC STEU
712 Direction
> 870751126
operator's-side
8701.35 405
860351016 - 860351076
Except maschine:
310 860351054, 860351062, 860351065
860551029 - 860551053 Direction
510 PLC STEU +
drive-side
612 PLC TEMP Except maschine
8605.35 050
810 860551045 + 860551048
860651006 - 860651017
860851001
> 869351014 Direction
drive-side
312 > 869551009
only PLC STEU 8601.35.401
512
+ 5 Servoaxis Direction
812
> 869851003 operator's-side
8601.35 402
General points:
• New HMI service switches on HMI "checklist constant"
On HMI page “Constant” new service switches for ultrasonic and signal exchange
CIP / UHT were placed.
25 Service Switch
2 UHT and handsh
• CombiSwift / -Fit
The selection of fitments was standardized in small and mid sized machines.
28 CF.doc
24 Service switch
Fit.doc
• Error "emergency shutdown" H2O2 heating with detailed specification of the reason
After an emergency shutdown of the H2O2 heaters the reason is displayed on the
HMI.
40 Emergency
shutdown caused
17 Adjust mode
with checklist to co
• Zyklon-hoover
Some customers have an external suction system for dedusting. It is secured by a
motor protection switch. In case of a failure of the motor protection switch an error
message appears on the HMI.
23 Brief
description of the
Bugfixing:
• Input values pusher cycle calculation
If both HMI-input values for the calculated pusher are zero the PLC stopped.
02 Sterile Water
Flush.doc
03 Extended Fill
Management.doc
04 Startup
Procedure & Outp
Delivery:
DVD with data for the PLC, HMI and LNG-language files and printed electrical circuit
diagram and description of the software changes.